SPEED SENSORS SIGNAL CONDITIONERS. Standard & Custom Sensors, Signal Conditioners and Interface Electronics

Similar documents
INSTALATION, OPERATION & MAINTENANCE MANUAL. PA-1001A Series SIGNAL CONDITIONER & CONVERTORS

Sensor Options. Rev

REPLACING ACC7B WITH CAT2

F-SERIES FOR. Indicators Totalizers Transmitters Flow computers Batch controllers Monitors. Flow Level Pressure Temperature

SC-FI Series Frequency to Current Signal Conditioner

LST-100 Digital Tachometer

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

TRONIC Digest. TRONIC Digest Pressure and Temperature Transmitters

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Isolators A3/1. Vibration Transducer Supply Unit Series

Power supply. Calibration. Surface finishing. Seal. Process connection

Differential-Hall-Effect based Sensors Ex ia for Detection of Speed and Direction of Rotation in Hazardous Areas Zone 0 or 1 Series A5S1DD3 / A5S1DS3

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Programmable Universal Frequency Transducer

IP26 Series Current to Pneumatic Converter

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Differential-Hall-Effect based Sensors for Detection of Speed and Direction of Rotation with two phase-shifted speed signals Series A5S0DD4 / A5S0DS4

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

4-20 ma Vibration Transmitter, Top connector

Two-Wire Programmable Transmitter for:

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

Kotron Model 82 CE RF Level Transmitter

Fisher 4200 Series Electronic Position Transmitters

Digital flow transmitter for continuous flow measurement

MTL4000 SERIES. isolating IS interface units. For close integration of IS circuits into processconnected

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Two Wire Temperature Transmitter LTX-3000-H-2 LTX-3000-H LTX-3000-W LTX-3000-D

ECET 211 Electric Machines & Controls Lecture 4-2 Motor Control Devices: Lecture 4 Motor Control Devices

Condition Monitoring Custom Products

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

DST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

F2A3X Frequency to Analog Converter Module

Model 2400 Explosion-Proof M/P Converters -- LOCK IN LAST POSITION --

Single-Channel Safety Barriers Series 9001

9/28/2010. Chapter , The McGraw-Hill Companies, Inc.

Table of Contents. Tachometers. ...Introduction Tachpak 10 & Tachtrol 10 & Tachtrol plus Accessories...

Inductive sensor slot-type SI2-K08-AP7

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

Vibration Transmitter

IOM. Model 1050 Strain Gage Transmitter Installation & Operation Manual. (Cage Code #1MU21)

Series GLET Accessory for dataloggers series GL in modular enclosure

TETRA COMPACT LOW VOLTAGE BRUSHLESS SERVOMOTORS

Aero Support Ltd, 70 Weydon Hill Road, Farnham, Surrey, GU9 8NY, U.K.

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

Mass Flow and Density Transmitter

Two-channel safety barriers Series 9002

1443 Series Accelerometers Specifications

Wireless Temperature Transmitters Series XYR 5000, Model WT5xx/WT5xxR/WT5xxT Specifications - Americas

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Section 11 Electronic Position Controls & Encoders

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

WORLD S SMALLEST BARGRAPH METER LOOP OR AC/DC POWERED > 30 INPUT SIGNAL CONDITIONERS

Inductive Proximity Detectors Technical Guide

Wireless Dual Discrete Input Transmitter Series XYR 5000, Model WW59x Specifications - Americas

Target disk flowmeter for liquids and gases

Rotary Measurement Technology Incremental Encoders

Dynalco LP 2018, effective June 15, 2018 Part Number Description Description 2

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Level gauges Series LT Level indicator, switch and transmitter for liquids

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

SFC Smart Field Communicator Model STS103. Specification 34-ST /24/06. Description. Function. Page 1 of 5

CERTIFICATE OF COMPLIANCE

Fisher 646 Electro-Pneumatic Transducers

Mid-West. Instrument. Model 142 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Kotron Sentinel Model 804 RF Level Transmitter

Certified according to DIN EN ISO Technical Datasheet EWS. Intrinsically Safe Supply and Separation Amplifier

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

The outputs can also be programmed as 0-5 Vdc, 0-10 Vdc, 0-20 ma, 4-20 ma, Frequency, RPM, PWM or digital on/off signals.

Binary Output Series 9175

Proximity Transmitters and Seismic Vibration Transmitters

Installation Instructions for the 50FY Series Hall Effect Door Interrupt System, EN954 Category III

Kotron Sentinel Model 804 RF Level Transmitter

FC Series Signal Conditioners

Loop Powered Indicator

Potential Applications

Coriolis Massflowmeter

Optional end of travel limit switches for user setting of minimum and maximum pressure values.

Optional end of travel limit switches for user setting of minimum and maximum pressure values.

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Order/Technical Support Tel: (800) / FAX: (800) /

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

RCM DIRECT READING FLOWMETER

Wireless Acoustic Transmitters Series XYR 5000, Model WN571 Specifications - Americas

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

GTS High Frequency Pulser. Technical Bulletin

Coriolis Massflowmeter

CERTIFICATE OF COMPLIANCE

GEMINI PRESETTABLE DUAL RATE INDICATOR WITH RATIO (A/B)

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

INLINE flowmeter for continuous flow measurement

Transcription:

for INNOVATIVE SENSOR SOLUTIONS Standard & Custom Sensors, Signal Conditioners and Interface Electronics SPEED SENSORS Magnetic Speed Sensors (Active & Passive) Hall Effect Speed Sensors, GBR (Zero Speed) RF Pickups (Near Zero Speed) Intrinsically Safe Speed Sensors and other PICKUPS for: SPEED POSITION PROXIMITY ACCELERATION TACHOMETERY SYNCHRONIZATION FLOW METERS DIRECTION Standard Temperature Range -150 to 330 F High Temperature Speed Sensors to 1000 F Cryogenic Sensors to -450 F SIGNAL CONDITIONERS Magnetic & RF Sensor Preamps Frequency to Voltage Converters 4-20mA Converters Speed/Flow Switches Directional Indicators DC Power Supplies & Enclosures THUNDERBIRD INTERNATIONAL CORPORATION PO Box 360 Emigrant, MT 59027 406-333-4967 FAX: 406-333-4259 www.spectecsensors.com An ISO 9001:2000 Certified Company DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 1 of 21

PASSIVE MAGNETIC SPEED SENSORS Variable Reluctance Sensors - Inductive Sensors Output Voltage (Vpp): Air Gap: Temp. Ranges: 3/16 Coil Type 1: Temp Ranges: Contact Spectec for magnetic pickup s coil resistance/inductance/output voltage specs. M VR Sensor:.25 max depending on target mass and velocity. MI Inductive Sensor: 1 max. depending on magnetic field strength and velocity. 2T: -100 to 250 F (-73 to 120 C) 3T: -150 to 330 F (-101 to 165 C) 5HT: -450 to 450 F (-270 to 232 C) 8HT: -450 to 850 F (-270 to 454 C) NOTE: Can be used with PA-20 signal conditioners for digital output. 10-32 0.5 to 2.5 (13 to 64 mm) R: 100 Ohm; L: 5mH; 8Vpp 2T or 5HT 1/4 M6 Coil Type 1: Coil Type 2: Temp Ranges: 1/4-40, 1/4-28, M6x1 0.6 to 3 (15 to 75 mm) 125 Ohm; 10 mh; 5 Vpp 250 Ohm; 10 mh; 10 Vpp 2T or 5HT 3/8 M10 Coil Type 1: Coil Type 2: Coil Type 3: Coil Type4: Temp Ranges: 3/8-24, M10x1.25 0.6 to 5 (15 to 130 mm) 100 Ohm; 16 mh; 25 Vpp 250 Ohm; 10 mh; 10 Vpp 650 Ohm; 160 mh; 85 Vpp 1100 Ohm; 450 mh; 110 Vpp 2T, 3T or 5HT 1/2 M12 Coil Type 1: Coil Type 3: Temp Ranges: 1/2-20, M12x1 0.8 to 5 (20 to 130 mm) R: 140 Ohm; L: 20mH; 30Vpp R: 650 Ohm; L: 160mH; 85Vpp 2T or 5HT DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 2 of 21

PASSIVE MAGNETIC SPEED SENSORS Variable Reluctance Sensors - Inductive Sensors Temp Ranges: -18 UNF, x1.5 0.8 to 10 (20 to 250 mm) 2T, 3T or 5HT Coil Type 1: Coil Type 2: Coil Type 4: Coil Type 5: Coil Type 6: Coil Type 7: 100 Ohm; 30 mh; 45 Vpp 230 Ohm; 90 mh; 75 Vpp 100 Ohm; 700 mh; 210 Vpp (Standard) 1500 Ohm; 800 mh; 240 Vpp 3000 Ohm; 1500 mh; 290 Vpp 5000 Ohm; 2500 mh; 330 Vpp (High Output) 11/16 Coil Types: Temp Ranges: 11/16-24 0.8 to 3.5 (20 to 90 mm) 4 through 7 2T, 3T or 5HT Coil Types: Temp Ranges: -16, -20, x1.5 0.8 to 10 (20 to 250 mm) 1 through 7 2T, 3T or 5HT 11/16 Coil Type 1: Temp Range: -18, 11/16-24, -16, -20, x1.5 3 to 10 (76 to 250 mm) 120 Ohm 8HT: -450 to 850 F (-270 to 454 C) High Temperature Magnetic Sensor Dual Output Magnetic Speed Sensors Available in the same housing configurations as single output models. 0021: Connector Version 0022: Lead Wire Version DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 3 of 21

DIGISPEC ACTIVE MAGNETIC SPEED SENSORS With Integral Amplifier Supply Voltage (Vs): Air Gap: Temp. Ranges: 3.5-30 Vdc @ 15 ma, MICROPOWER Model: 2 to 6 Vdc @ 0.06mA 0 - Vs, 0-5V (TTL), 0-10 V, Open Collector (NPN or PNP) 0 to 40 khz (Std), 100 khz (Special order), MICROPOWER Model: 1 Hz to 30 khz 0.03 Typ., 0.50 Max. depending on target mass and velocity. 2TE: -40 to 220 F (-40 to 120 C) 3TE: -40 to 290 F (-40 to 145 C) DIGISPEC Magnetic pickups produce a digital frequency output directly proportional to speed. The internal amplifier provides for constant pulse shaping, signal amplitude, logic-level output, robust signal-to-noise ratio, usable at lower RPMs and greater air gap between the sensor and the actuator. MICROPOWER versions are available for ultra low current draw, ideal for battery applications. A sanitary version to NEMA 6, IP65 & IP67 is also offered. All models are also available with an internal temperature probe (RTD100 Ohm, NTC10 k Ohm). -18 UNF, x1.5 2.5 to 10 (64 to 250 mm) 11/16 11/16-24 2.5 to 3.5 (64 to 90 mm) -16, -20, x1.5 2.5 to 10 (64 to 250 mm) DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 4 of 21

Supply Voltage (Vs): Input Current: Input Sensitivity: Temp. Ranges: SHORT FORM CATALOG DIGISPEC PREAMPS & CONVERTERS PA-20 For Standard Magnetic Speed Sensors 5-30 Vdc Std Micropower: 2-6 Vdc (for ultra low current draw, ideal for battery applications) 15 ma Std. 0.06 ma 1-10 Vpp Std. 30 mv, 12 mv, 5 mv 12-40 mv Standard: -40 to 160 F (-40 to 80 C), In Line & Ultra Compact: -40 to 240 F (-40 to 120 C) To 10 khz, up to 40 khz varies with signal level, target size, air gap & sensor. Micro 1 Hz-30 khz 4021 Pulse Amplifier Multi Output, Noise Canceling Standard and/or Opto-isolated Fits GUAL-16 type Explosion-proof enclosure 4022 Pulse Amplifier With Optional Output Select Fits Elby Explosion-proof enclosure 4024 in-line Pulse Amplifier With MS Connector 4024M 4023 Pulse Amplifier Fits Y1 Explosion-proof enclosure 4024H Ultra Compact 4026 FTC - FTV Converter FTC Converter: 4-20mA, 10-50mA FTV Converter: 0-5 Vpp, 0-10 Vpp Fits Y3 Explosion-proof enclosure 4027 Freq to Current Converter 4-20 ma Converter fits Elby Explosion-proof enclosure 4028 Freq to Voltage Converter 0-5 V or 0-10 V FTV Converter fits Elby Explosion-proof enclosure 4029 Digital Opto-Isolated Current Loop Fits Elby Explosion-proof enclosures 4033 Directional Mag Preamp Provides directional data from two magnetic speed pickups Fits Y3 Explosion-proof enclosure 4051 Speed Flow Switch, SS1 For Magnetic Speed sensors, Open collector output Fits Elby Explosion-proof enclosure DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 5 of 21

RF PICKUPS - FLOWMETER SPEED SENSORS No Magnetic Drag Inductance/Resistance Options: Air Gap: Temperature Ranges: NOTE: Must be used with PA-10 RF4: 4.00 Ohm, 0.36 mh RF10: 12.00 Ohm, 1.00 mh Open Face:.160, Closed Face:.130 5 Hz to 6000 Hz 3T: -150 to 330 F (-101 to 165 C) 4HT: -350 to 400 F (-157 to 204 C) 5HT: -450 to 450 F (-270 to 232 C) 3/8 M10 3/8-24, M10x1.25 0.5 to 5 (13 to 130 mm) 1/2 1/2-20 0.5 to 5 (13 to 130 mm) -18 UNF, x1.5 0.5 to 10 (13 to 250 mm) 11/16 11/16-24 0.5 to 3.5 (13 to 90 mm) -16, -20, x1.5 0.5 to 10 (13 to 250 mm) DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 6 of 21

DIGISPEC RF PICKUP SPEED SENSORS With Integral Amplifier - Near Zero Speed - No Magnetic Drag Supply Voltage (Vs): Air Gap: Temp. Ranges: 7-30 Vdc @ 15 ma 0 - Vs, 0-5V (TTL), 0-10 V, Open Collector (NPN or PNP) 0.5 Hz to 5 khz 0.16 (4mm) Max., depending on target mass and velocity. 2TE: -40 to 220 F (-40 to 120 C) 3TE: -40 to 290 F (-40 to 145 C) SPECTEC's RF pickups are active sensors driven by an external RF ("carrier") signal conditioner. Together they complete an oscillating circuit. The output of this circuit is amplitude modulated when a ferrous object passes by the pickup coil. This change in modulation of the carrier frequency is converted into a square wave pulse by the signal conditioner for computing and/or further processing. DIGISPEC RF pickups have good EMI protection and reverse polarity protection. DIGISPEC RF flow meter sensors are available in open face design for greater sensitivity or closed face design for greater environmental sealing. Custom digital RF pickup sensors or OEM replacement speed sensors available. An internal temperature probe (NTC10, RTD100 or others) is available which is positioned near the face of the sensor. -18 UNF, x1.5 2.5 to 10 (64 to 250 mm) 11/16 11/16-24 2.1 to 3.5 (54 to 90 mm) -16, -20, x1.5 2.1 to 10 (54 to 250 mm) DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 7 of 21

DIGISPEC PREAMPS & CONVERTERS For Standard RF Speed Sensors PA-10 Supply Voltage (Vs): Input Current: Temp. Ranges: 5-30 Vdc Std 10 ma 0-10 Vpp Std. or 0-5 Vpp (Micropower) Near 0 to 5 khz depending on target mass and air gap. 2TE: -40 to 220 F (-40 to 120 C), 3TE: -40 to 290 F (-40 to 145 C) 4013 Pulse Amplifier Fits Y1 Explosion-proof enclosure 4014 in-line Pulse Amplifier With MS Connector 4016 FTC - FTV Converter FTC Converter: 4-20mA, 10-50mA FTV Converter: 0-5 Vpp, 0-10 Vpp Fits Y3 Explosion-proof enclosure 4014M 4014H 4032 Two Wire Temperature Transmitter For use with RTDs or thermocouples Fits Y3 Explosion-proof enclosure 4100 Universal Power Supply For Magnetic speed sensor & RF pickup signal conditioners In NEMA 4 enclosure Supply voltage (Vs): Voltage Out (Vo): Connections: 120 Vac 10%, 25 ma 5Vdc, 12Vdc or 24Vdc AC primary, DC output DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 8 of 21

DIGISPEC HALL EFFECT MAGNETIC SENSORS Magnetic Actuated - Zero Speed Sensors Supply Voltage (Vs): Air Gap: Temp. Ranges: 4.5-30 Vdc @ 13 ma 0 - Vs, 0-5V (TTL), Open Collector (NPN or PNP) 0 to 25 khz (Std), 100 khz (Special order) 0.50 (12mm) Max. 2TE: -40 to 220 F (-40 to 120 C) 3TE: -40 to 290 F (-40 to 145 C) 1/4 M6 1/4-28, 1/4-40, M6x1 0.8 to 3 (20 to 75 mm) 0155A 0155M (M6) 0155K 0155 0155S 3/8 M10 3/8-24, M10x1.25 0.8 to 5 (20 to 130 mm) 1/2 0158S 1/2-20 0.8 to 5 (20 to 130 mm) 0158A 0158M (M12) 0158 0158MC (M12) -18 UNF, x1.5 0.8 to 10 (20 to 250 mm) Available in Dual Output 0161 0161 () 0160C 0160MC () 0160Y -16, -20, x1.5 2.1 to 10 (54 to 250 mm) 0172 0172 () 0162C 0162MC () 0172Y DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 9 of 21

DIGISPEC HALL EFFECT GEAR TOOTH SENSORS Gear Position Sensor - Zero Speed Sensors Supply Voltage (Vs): Air Gap: Temp. Ranges: 4.5-30 Vdc @ 13 ma 0 - Vs, 0-5V (TTL), Open Collector (NPN or PNP) 0 to 25 khz (Std), 100 khz (Special order) 0.16 (4mm) Max. 2TE: -40 to 220 F (-40 to 120 C) 3TE: -40 to 290 F (-40 to 145 C) 1/4 M6 1/4-28, 1/4-40, M6x1 0.8 to 3 (20 to 75 mm) 0165A 0165M (M6) 0165K 0165 0165S 3/8 M10 3/8-24, M10x1.25 0.8 to 5 (20 to 130 mm) 0167A 0167M (M6) 0167 0166 0167S 1/2 0168S 1/2-20 0.8 to 5 (20 to 130 mm) 0168A 0168M (M12) 0168A 0168MC (M12) -18 UNF, x1.5 0.8 to 10 (20 to 250 mm) Available with Dual Output 0169 0169 () 0170A 0170MC () 0180Y -16, -20, x1.5 2.1 to 10 (54 to 250 mm) 0172 0171 0172Y Available with Dual Output and an Additional Directional Output DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 10 of 21

DIGISPEC HALL EFFECT DUAL OUTPUT SENSORS Gear Tooth Sensors - Direction Detection - Zero Speed Sensors Supply Voltage (Vs): Air Gap: Temp. Ranges: 3.5-30 Vdc @ 13 ma 0 - Vs, 0-5V (TTL), Open Collector (NPN or PNP) 0 to 25 khz (Std), depending on target size and distance 5DP (M5): 0.16 (4mm) Max. 24DP (M1): 0.08 (2mm) Max. 2TE: -40 to 220 F (-40 to 120 C) 3TE: -49 to 300 F (-45 to 150 C) DIGISPEC Hall Effect Dual Output Sensors provide two digital output signals detecting speed (down to true zero speed) and direction of rotation of gear teeth and ferrous targets. Sensors are also available with LED indicators. -18 UNF, -16, -20, x1.5 0.8 to 5 (20 to 130 mm) 0174 Series - Connector 0175 Series - Lead Wires DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 11 of 21

DIGISPEC HALL EFFECT QUADRATURE SENSORS Gear Tooth Sensors - Direction Detection - Zero Speed Sensors Supply Voltage (Vs): Air Gap: Temp. Ranges: 8.5-30 Vdc @ 13 ma 0-5V (TTL), Open Collector (NPN or PNP) 0 to 25 khz (Std), depending on target size and distance 0.16 (4mm) Max. depending on target mass 2TE: -40 to 220 F (-40 to 120 C) 3TE: -45 to 300 F (-40 to 150 C) DIGISPEC Hall Effect Quadrature Sensors provide two digital output signals, 90º out of phase to each other, detecting speed (down to true zero speed) and direction of rotation of gear teeth and ferrous targets. 11/16-18 UNF, 11/16-24, -20, x1.5 2.1 to 5 (54 to 130 mm) 0190 Series - Connector 0191 Series - Lead Wires -16, -20 3.15 (79.5 mm) 0193Y DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 12 of 21

DIGISPEC LINEAR / ANGULAR POSITION SENSORS Magnetic Sensors - Direction Detection - Zero Speed Sensors DIGISPEC linear position sensors are designed to detect continuous variations in the magnetic field and convert field strength to a proportional voltage. The output voltage produced for zero field is nominally 2.5v, with a standard transfer function of +/- 10 mv/gauss. Magnetic sensitivity is along one axis only. Several units can be combined to measure (X, Y, Z) magnetic field vectors. Custom ranges, output configurations, sensitivity and packaging are available on request. Intrinsically Safe linear position sensors are also available. Voltage Supply (Vs): -18 UNF, -16, -20, x1.5, x1.5 2.5 to 10 (64 to 250 mm) 8-30 Vdc @ 5 ma 0.06-4.5 V typical 0220 Series - Connector 0221 Series - Lead Wires DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 13 of 21

IS MAGNETIC SPEED SENSORS Intrinsically Safe VR Sensors - Inductive Sensors COMPLIANCE: CE: EN550011, EN50022-2 IS Class I, Zone 0, AEx [ia] IIC CLASS I, II, III, Div 1 Group ABCDEFG INSTALLATION: Installations must meet the requirements of intrinsically safe systems for hazardous (classified) locations and must follow details specified in FM Global control drawing 85047. -18 UNF, x1.5 2 to 10 (45 to 250 mm) 11/16 11/16-24 1.8 to 3.5 (45 to 90 mm) -16, -20, x1.5 1.8 to 10 (45 to 250 mm) DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 14 of 21

IS DIGISPEC MAGNETIC SENSORS Intrinsically Safe Flowmeter Sensors COMPLIANCE: CE: EN550011, EN50022-2 IS Class I, Zone 0, AEx [ia] IIC CLASS I, II, III, Div 1 Group ABCDEFG INSTALLATION: Installations must meet the requirements of intrinsically safe systems for hazardous (classified) locations and must follow details specified in FM Global control drawing 85047. Supply Voltage (Vs): Temperature Range: 8-30 Vdc 0 - Vs, 0-5V (TTL), 0-10 V, Open Collector (NPN or PNP) ~5 Hz to- 10 khz depending on target size, distance and pickup sensitivity T5: -40 to 149 F (-40 to 65 C) T6: -40 to 185 F (-40 to 85 C) -18 UNF, x1.5 2.5 to 10 (64 to 250 mm) 11/16 11/16-24 2.5 to 3.5 (64 to 90 mm) -16, -20, x1.5 1.8 to 10 (45 to 250 mm) DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 15 of 21

IS RF PICKUP SENSORS Intrinsically Safe Magnet Actuated - Zero Speed Sensor COMPLIANCE: CE: EN550011, EN50022-2 IS Class I, Zone 0, AEx [ia] IIC CLASS I, II, III, Div 1 Group ABCDEFG INSTALLATION: Installations must meet the requirements of intrinsically safe systems for hazardous (classified) locations and must follow details specified in FM Global control drawing 85047. NOTE: RF pickups must be used with Intrinsically Safe PA-10 Inductance/Resistance Options: Air Gap: Temperature Ranges: IS70: IS71: IS72: IS73: RF4: 4.00 Ohm, 0.36 mh RF10: 12.00 Ohm, 1.00 mh Open Face:.160, Closed Face:.130 5 Hz to 6000 Hz T5: -40 to 149 F (-40 to 65 C) T6: -40 to 185 F (-40 to 85 C) Connector Lead Wire Connector with temperature probe Lead Wire with temperature probe 11/16-18 UNF, x1.5, 11/16-20 1.8 to 10 (45 to 250 mm) -16, -20, x1.5 1.8 to 10 (45 to 250 mm) DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 16 of 21

IS DIGISPEC RF SENSORS Intrinsically Safe RF Pickups With Integral Amplifiers COMPLIANCE: CE: EN550011, EN50022-2 IS Class I, Zone 0, AEx [ia] IIC CLASS I, II, III, Div 1 Group ABCDEFG INSTALLATION: Installations must meet the requirements of intrinsically safe systems for hazardous (classified) locations and must follow details specified in FM Global control drawing 85047. Supply Voltage (Vs): 8-30 Vdc, Reverse polarity protected; 4.5-8 Vdc optional 0 - Vs Open Collector - NPN, 0-5V (TTL), 0-10 V 0.5 Hz to 5 khz depending on target size, distance and pickup sensitivity Temperature Range: T5: -40 to 149 F (-40 to 65 C) T6: -40 to 185 F (-40 to 85 C) -18 UNF, x1.5 3 to 10 (76 to 250 mm) 11/16 11/16-24 2.8 to 3.5 (71 to 90 mm) -16, -20, x1.5 2.8 to 10 (71 to 250 mm) Detailed specification sheets are available for each sensor listed; please contact Spectec for more information. DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 17 of 21

IS HALL EFFECT MAGNETIC SENSORS Intrinsically Safe Magnet Actuated - Zero Speed Sensor COMPLIANCE: CE: EN550011, EN50022-2 IS Class I, Zone 0, AEx [ia] IIC CLASS I, II, III, Div 1 Group ABCDEFG INSTALLATION: Installations must meet the requirements of intrinsically safe systems for hazardous (classified) locations and must follow details specified in FM Global control drawing 85047. 11/16 Supply Voltage (Vs): Target: Temperature Range: IS159: IS160: IS161: IS180: IS181: 5-30 Vdc 0 - Vs, 0-5V (TTL), 0-10 V, Open Collector (NPN or PNP) 0 to 25 khz depending on target size, distance and pickup sensitivity Standard: Bi-polar (N & S pole) activation; Optional: Uni-polar (N or S pole) also available T5: -40 to 149 F (-40 to 65 C) T6: -40 to 185 F (-40 to 85 C)) Single Output, Lead Wire, Single Output, Lead Wire Single Output, Connector Dual Output, Connector Dual Output, Lead Wire -18 UNF, x1.5, 11/16-20 1.8 to 10 (45 to 250 mm) LED indicator -16, -20, x1.5 1.8 to 10 (45 to 250 mm) Detailed specification sheets are available for each sensor listed; please contact Spectec for more information. DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 18 of 21

IS HALL EFFECT GEAR TOOTH SENSORS Intrinsically Safe Gear Sensor, Zero Speed Sensor COMPLIANCE: CE: EN550011, EN50022-2 IS Class I, Zone 0, AEx [ia] IIC CLASS I, II, III, Div 1 Group ABCDEFG INSTALLATION: Installations must meet the requirements of intrinsically safe systems for hazardous (classified) locations and must follow details specified in FM Global control drawing 85047. 11/16 Supply Voltage (Vs): Air Gap: Temperature Range: IS170: IS171: IS174: IS175: IS190: IS191: Standard: 5-30 Vdc; LED Option: 12-30 Vdc 0 - Vs, 0-5V (TTL), 0-10 V, Open Collector (NPN or PNP) 0 to 25 khz depending on target size, distance and pickup sensitivity 5DP (M5): 0.16 (4mm) Max. 24DP (M1): 0.08 (2mm) Max. T5: -40 to 149 F (-40 to 65 C) T6: -40 to 185 F (-40 to 85 C) Single Output, Connector Single Output, Lead Wire Dual Output, Connector Dual Output, Lead Wire Quadrature Output, Connector Quadrature Output, Lead Wire -18 UNF, x1.5, 11/16-20 1.8 to 10 (45 to 250 mm) -16, -20, x1.5 1.8 to 10 (45 to 250 mm) Detailed specification sheets are available for each sensor listed; please contact Spectec for more information. DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 19 of 21

IS LINEAR/ANGULAR POSITION SENSORS Intrinsically Safe Position Sensor COMPLIANCE: CE: EN550011, EN50022-2 IS Class I, Zone 0, AEx [ia] IIC CLASS I, II, III, Div 1 Group ABCDEFG INSTALLATION: Installations must meet the requirements of intrinsically safe systems for hazardous (classified) locations and must follow details specified in FM Global control drawing 85047. Supply Voltage (Vs): 8-30 Vdc 0.06-4.5 V typical Air Gap: To > 1 @ 3000 Gauss typical Temperature Range: T5: -40 to 220 F (-40 to 120 C) T6: -45 to 300 F (-40 to 150 C) -18 UNF, x1.5 2 to 10 (78 to 250 mm) -20, x1.5 2 to 10 (78 to 250 mm) DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 20 of 21

IS DIGISPEC PREAMPS & CONVERTERS For Intrinsically Safe Magnetic Speed Sensors COMPLIANCE: CE: EN5500 11, EN50022-2 IS Class I, Zone 0, AEx [ia] IIC CLASS I, II, III, Div 1 Group ABCDEFG INSTALLATION: Installations must meet the requirements of intrinsically safe systems for hazardous (classified) locations and must follow details specified in FM Global control drawing 85047. 0-5 V, 0-10 V Temperature Range: T5: -40 to 220 F (-40 to 120 C) T6: -45 to 300 F (-40 to 150 C) IS4022 Pulse Amplifier IS4027 Freq to Current Converter For IS magnetic sensors with 4-20 ma Converter fits Optional output selection Elby Explosion-proof enclosure Supply Voltage (Vs): 7.5-30 Vdc Supply Voltage (Vs): 9-30 Vdc Freq Range: ~5 Hz to 10kHz; ~5Hz to 40 khz at increased signal level IS4028 Freq to Voltage Converter 0-5 V or 0-10 V FTV Converter fits Elby Explosion-proof enclosure Supply Voltage (Vs): 12-30 Vdc DATE 12-09-2009 Rev 2 SHORT FORM CATALOG Page 21 of 21