TNT X-Ray Test Tools

Similar documents
Technical data ESA614 Electrical Safety Analyzer

QA-ES III Electrosurgical Analyzer

QA-ES III Electrosurgical Analyzer

TRIAD TnT X-Ray Field Service/Calibration/QA Kit Model 10500AMT

RaySafe Xi. Specifications

Cylindrical Ion Chambers Victoreen Model 550 Series

Cylindrical Ion Chambers

TNT DoseMate Dosimeter Detector

RaySafe X2. Effortless measurements of X-ray

Diagnostic Imaging. Product Catalog 2007/2008. Fluke Biomedical. The accuracy you need from a company you can trust.

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Less effort. More insight.

Ansur TNT Users Manual. Plug-In

5790A Automated AC Measurement Standard

Fluke 712B and 714B Temperature Calibrators

Model 530 Precision Electrometer/Dosemeter

RaySafe Xi. User Manual

Inovision Model 451P Pressurized µr Ion Chamber Survey Meter

ELECTRONIC CONTROL CONCEPTS 160 Partition Street Saugerties, NY or local phone

Victoreen 4000M+ X-Ray Test Device

Nuclear Associates &

Fluke 370 FC Series True-rms Wireless AC/DC Clamp Meters

Voltage Sensors URV5-Z

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 3540 FC Three-Phase Power Monitor

Fully Automatic X-ray meter kvp, dose, rate, HVL and time Extremely easy to use. Unfors ThinX RAD for Radiographic Quality Control

Nuclear Associates

How to measure mas using the current clamp with TNT 12000

Fluke199XRAY. Users Manual. Medical ScopeMeter

Nuclear Associates

Complimentary Reference Material

Nuclear Associates

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection

High Speed Milliohm Resistance Meter

1587/1577 Insulation Multimeters

Additel 875 Series Dry Well Calibrators

GE AMX 4+ Portable X-Ray

Nuclear Associates

Unfors EDD-30 Radiation Protection in Fluoroscopy

High-precision process calibrator Model CED7000

Piranha & QABrowser. Reference Manual - English - Version 4.3A. RTI article number:

Impulse 6000D/7000DP Defibrillator/External Pacer Analyzer

Agilent 970-Series Handheld Multimeters Data Sheet

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

Technical Datasheet GT-8550B Series USB Power Sensor 10 MHz to 26.5 GHz

MA24104A. Inline High Power Sensor. True-RMS, 600 MHz to 4 GHz

For the National Voluntary Laboratory Accreditation Program

N432A Thermistor Power Meter DATA SHEET

Additel 875 Series Dry Well Calibrators

OEM s #1 Choice for X-Ray Sources and Generators. Focus on Performance, Reliability, Form Factor, and Versatility.

Spectrum Analyzer R&S FS300

Portable Multi-Channel Recorder Model DAS240-BAT

History of digital imaging

BM25 Automated 5-kV Insulation Tester

Fluke 5820A Oscilloscope Calibrator Specifications

Fluke and

Fluke Advanced Test Equipment Rentals ATEC (2832) Three-Phase Power Recorder

Battery Simulator Battery/Charger Simulators

9190A Ultra-Cool Field Metrology Well. Ultra-cool dry-block calibrator with best-in-class stability

R&S ZVT Vector Network Analyzer Specifications

SERVICE & QUALITY CONTROL KITS

5080A Multi-Product Calibrator

JD723A/JD724B/JD726A Cable and Antenna Analyzers

Hand-held temperature calibrator Model CEP3000

GC723A / GC724B Cable and Antenna Analyzer

Oscilloscope Calibration Options for Fluke 5500A/5520A Multi-Product Calibrators Extended Specifications

Vector Network Analyzers ZVB

CT Analyzer. Test Set for Analysis of Metering Current Transformers According to IEEE C57.13 Standard

New spectral benefi ts, proven low dose

FRAX Series Sweep Frequency Response Analyzers

35080M kvp Divider. Operators Manual

Ultra-cool dry-block calibrator with best-in-class stability Technical Data. Improved process control

HMC-T2220B. Portable & Battery Operated! Portable Synthesized Signal Generator, 10 MHz to 20 GHz. Instrumentation Product Support at

734A and 7001 DC Reference Standards

MIT510/2, MIT520/2 and MIT1020/2

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

Agilent EPM Series Power Meters

U1604A Handheld Oscilloscopes, 40 MHz

OtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06

Fluke 1750 Three-Phase Power Recorder

Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation

Half value layer and AEC receptor dose compliance survey in Estonia

2302 Battery Simulator 2306, 2306-PJ Battery/Charger Simulators

Fluke 1587 FC/1577 Insulation Multimeters

CALYS 75. Field documenting multifunction calibrator

Oscilloscope Probes and Accessories

6135A/PMUCAL Phasor Measurement Unit Calibration System

Nuclear Associates , , CT Head and Body Dose Phantom

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA

For easy-to-use loggers, look no further! WIRELESS MINI LOGGER LR8512, LR8513, LR8514, LR8515

MIT510, MIT520 and MIT1020

DC Electronic Loads 8500 Series

vscan Data Sheet V1.0

Oscilloscope Calibration Options for 55XX Series Multi-Product Calibrators

Model 1140A Thermocouple Simulator-Calibrator

5-kV and 10-kV Insulation Resistance Testers. n CAT IV 600 V safety rating. n Line supply or battery operated

LI-1500 Light Sensor Logger

5320A Multifunction Electrical Tester Calibrator. Verify and calibrate electrical test tools with a single instrument

Fluke Three-Phase Power Recorder. Never miss capturing a disturbance - with the exclusive threshold-free measurement system, it s automatic.

Transcription:

TNT 12000 X-Ray Test Tools Technical Data The TNT 12000 X-Ray Test Tools system is the newest and most comprehensive family of instruments available for assuring quality and safety of diagnostic x-ray imaging systems. With selection of all-in-one-exposure solid-state detector, dosimeter, ion chambers, optional ma/mas invasive shunt or non-invasive clamp device, and choice of handheld display or laptop interface (both completely wireless), the TNT 12000 X-Ray Test Tools provide state-of-the-art solutions for any x-ray test protocol. A long battery life ensures uninterrupted operation all day. The TNT 12000WD solid-state detector sets up in seconds and measures kvp, dose, dose rate, time, and half value layer (HVL) in a single exposure. The companion TNT 12000 DoseMate dosimeter and ion chambers provide precision dose and dose-rate measurement of radiographic, dental, fluoroscopic, and CT imaging systems. The wireless ZigBee interface allows for quick testing and reporting, and at less than 1 mw power is preferred over Bluetooth in medical settings where interference with delicate patient monitoring and treatment equipment may be a concern. Key features Choice of all-in-one detector, dosimeter, integral ma/mas, handheld display or user s own laptop interface ZigBee wireless operation Compact handheld design Sets up in seconds Displays all values in one shot (TNT 12000WD) Simple user interface Unbeatable ruggedness for long-term reliability 40 khz kv sampling rate to ensure accuracy with the most difficult applications (TNT 12000WD) Global support network delivering prompt service and peace of mind to Fluke Biomedical customers worldwide

System components TNT 12000 DoseMate dosimeter Featuring all-in-one-exposure measurements and ZigBee wireless communication combined with the rugged, reliable, and accurate design that is a Fluke trademark, the TNT 12000WD is a new breed of non-invasive x-ray test tool. Its compact design enhances portability and wireless operation ensures setup in seconds. Because the TNT 12000WD measures all parameters with every exposure, there is no need for complicated menu selection, further enhancing user productivity. TNT 12000WD always defaults to the last use when powered on, so when used often for repetitive procedures it is truly a one-button (power on) solution. TNT 12000WD has the expanded functionality needed for modern applications and can be managed with minimum keystrokes. Users can identify and select custom measurement protocols and save them for future use. Full test automation and documentation software is available for TNT 12000WD, creating the advantage of accurate, repeatable testing processes. The TNT 12000 DoseMate with ion chambers provides the precision dose measurements needed for absolute dose measurement integrity. Offering customizable measurement protocols, the DoseMate dosimeter provides comprehensive, repeatable testing for radiographic, dental, fluoroscopic, and CT imaging systems in just a few keystrokes. The TNT 12000 DoseMate is compatible with existing TRIAD and NERO external ion chambers, offering the newest dosimeter technology with minimum investment. ma/mas measurement Integrated ma/mas measurement capability is available with both the TNT 12000WD and the TNT 12000 DoseMate. A ma/mas-standard invasive shunt or optional non-invasive clamp device are available to meet the challenges of mas measurement with all types of x-ray systems. ZigBee wireless interface delivers measured results to the user s choice of handheld display or laptop, integrating all QA measurements on a single readout. 2 Fluke Biomedical TNT 12000 X-Ray Test Tools

TNT 12000D Wireless Display Ansur Test Automation Software The TNT 12000D Wireless Display has been specifically designed with user productivity in mind and displays all measured results, as well as identification information, battery level, calibration date and more. ZigBee wireless interface from the test device offers targeted communication to the mating display for speedy results reading up to 100 feet from the test device. Wireless communication and intelligent device interface allows the user to perform multiple exposures without leaving the radiation-shielded area, thus allowing complete test protocols to be performed with minimum travel between operator and test device. Low power requirements for ZigBee interface allow for extensive battery life as compared to Bluetooth test devices, which require frequent recharging from inefficient power drain. Test automation software allows preventative maintenance routines to be tightly controlled and consistently reported while directing users through prescribed test protocols with simple and efficient instruction. Test standardization minimizes human error and alleviates training requirements with step-by-step instruction. Photos, drawings, and instructional visual aids included in test protocols negate the need to carry bulky service manuals for complicated PM procedures. Professional electronic reporting and database/cmms interface allows for total PM and service data management. TNT 12000 X-Ray Test Tools Fluke Biomedical 3

We asked a real TNT 12000 user What is the #1 benefit of the TNT 12000 in your personal experience? The TNT 12000 makes my testing regime very simple and very simple to explain. How would you rate the ease of use of the TNT 12000 compared to devices you ve used in the past? The TNT 12000 has very high ease of use. On a scale of 1-10, I d call it a 9. How would you rate the durability/reliability of the TNT 12000 compared to devices you ve used in the past? You can tell by looking at the TNT 12000 that it s durable it looks overbuilt. I carry it around in a suitcase, throw it in the car, and subject it to lots of different temperatures. The solid-state technology makes it more durable. It seems far more resistant to extreme cold or heat than other devices I ve used in the past. Would you recommend the TNT 12000 as a good investment to other industry professionals, and if so why? Yes, and not only to other physicists but also to state agencies who need to go in and test equipment. This is something they can hang their hat on and call it the industry standard for test accuracy. Frederic Mis PhD, CHP 4 Fluke Biomedical TNT 12000 X-Ray Test Tools

Tecnical specifications TNT 12000 X-Ray Test Tools Physical specifications Display 320 x 240 Color LCD Size (WxDxH) TNT 12000D Display 15.5 cm x 11.4 cm x 4.1 cm (6.1 in x 4.5 in x 1.6 in) 17 cm x 11.4 cm x 4.4 cm TNT 12000 DoseMate Dosimeter (6.7 in x 4.5 in x 1.75 in) Weight TNT 12000D Display 0.422 kg (0.93 lb) 0.7 kg (1.5 lb) TNT 12000 DoseMate Dosimeter 0.5 kg (1.1 lb) Electrical specifications Battery Type Lithium-ion 3.7 V 4000 mah Charge time Approximately 5 hr Operating duration Approximately 8 hr minimum AC adapter Input voltage 100 V ac to 240 V ac Input frequency 50/60 Hz Input current 0.5 A (rms) Output voltage 6 V dc Environmental specifications Operating temperature 0 ºC to 35 ºC (32 ºF to 122 ºF) Storage temperature -35 ºC to 50 ºC (-31 ºF to 122 ºF) Operating humidity 20 % to 80 % RH (non-condensing) kvp measurements Units kvp Average (average of peaks during a specified interval) kvp Max (highest peak during a specified interval) PPV (peak practical voltage) Ranges Radio/Fluoro modes 40 kv to 150 kv Mo/Mo: 22 kv to 35 kv (standard calibration) Rh/Rh 25 kv to 49 kv (optional calibration) Mo/Rh 22 kv to 40 kv (optional calibration) Mo/Al 22 kv to 49 kv (optional calibration) Rh/Al 22 kv to 49 kv (optional calibration) W/Rh (optional calibration) W/Ag (optional calibration) Resolution 0.1 kv Accuracy Radio/Fluoro modes ± 2 % or ± 1 kv, whichever is greater ± 2 % or ± 0.7 kv, whichever is greater Reproducibility ± 1 % (std of 5 readings) Filtration correction range Radio/Fluoro modes 1 mm Al to 10 mm Al or equivalent 0 mm Al to 0.4 mm Al added filtration TNT 12000 X-Ray Test Tools Fluke Biomedical 5

continued Dose/exposure measurements Units Roentgens, Grays Range 0.5 mr to 999 R 5 µgy to 999 Gy Resolution 1 µr 0.01 µgy Accuracy ± 5 % Reproducibility ± 0.5 % (std of 5 readings) Filtration correction range Radio/Fluoro modes 1 mm Al to 10 mm Al or equivalent 0 mm Al to 0.4 mm Al added filtration kv correction range Radio/Fluoro modes 40 kv to 150 kv Mo/Mo: 22 kv to 35 kv Dose/exposure rate measurements Units Roentgens or Grays per hour, minute second, pulse Range 8 mr/s to 10 R/s 70 µgy to 100 mgy/s 130 µr/pulse to 160 mr/pulse (@ 60 pps) 1.2 µgy/pulse to 1.4 mgy/pulse (@ 60 pps) Accuracy ± 5 % Filtration correction range Radio/Fluoro modes 1 mm Al to 10 mm Al or equivalent 0 mm Al to 0.4 mm Al added filtration kv correction range Radio/Fluoro modes 40 kv to 150 kv Mo/Mo: 22 kv to 35 kv Exposure time: radiographic modes Units Milliseconds, pulses Range (@ stated accuracy) Milliseconds 10 ms to 9999 ms Pulses 1 pulse to 999 pulses Resolution Milliseconds 0.1 ms Pulses 1 pulse Accuracy Milliseconds 1 % or 0.5 ms Pulses ± 1 pulse Reproducibility Milliseconds 1 % or 0.5 ms Pulses ± 1 pulse Elapsed time: fluoro modes Range 10 sec to 9999 sec Resolution 0.1 sec Accuracy 1 % or 0.5 sec Average pulse rate: pulsed fluoro Range 1 pps to 999 pps Resolution 1 pps Accuracy 1 pps Average pulse width: pulsed fluoro Range 10 ms to 999 ms Resolution 0.1 ms Accuracy 1 % or 0.5 ms 6 Fluke Biomedical TNT 12000 X-Ray Test Tools

Half Value Layer (HVL) Range Radio/Fluoro modes 1.2 mm Al to 10 mm Al (equivalent) 0.2 mm Al to 0.6 Al (equivalent) Resolution Radio/Fluoro modes 0.1 mm Al (equivalent) 0.01 mm Al (equivalent) Accuracy Radio/Fluoro modes ± 10 % or 0.2 mm Al (equivalent) ± 5 % or 0.05 mm Al (equivalent) TNT 12000 DoseMate Dosimeter Accuracy Exposure and exposure rate accuracy Measurement modes Dose Rate ± 1 % of reading ± 2 range resolution steps over range of 18 C to 28 C and ± 2 % of reading ± 2 range resolution steps over the full operating temperature range of 0 C to 50 C 3 % NIST-traceable calibration is provided with each system and includes effects of 96035B, and 96020C Autoranging across five decades of sensitive ranges Automatic drift and offset compensation Automatic post-exposure display hold Measurement range covers a span from low-level image intensifier measurements to unattenuated, direct beams Automatic offset compensation and nonlinear filtering Autoranging provides five decades of sensitivity ranges Display updates once per second Low rate mode This mode is only for making very low dose rate measurements. Nonlinear digital filtering and autoranging provide five decades of sensitivity ranges. Display updates once per second. In this mode, automatic current offset and drift compensation are disabled. As a result, the system can display very low dose rates Power requirements Bias voltage supply Fixed electronic bias (~300 V) Bias voltage removed from triaxial input connector at instrument turnoff Connections Ion chamber input Power General information Display Weight Dimensions (maximum) (WxDxH) Triax, BNC Collector and guard positive-biased relative to ion chamber body and service dosimeter chassis Same as TNT 12000WD Wireless ZigBee or optional USB interface to TNT 12000 display indicates all ion chamber identification information, numerical measurement results, battery level, calibration date, and other information 0.68 kg (1.5 lb) 15.2 cm x 11.4 cm x 4.45 cm (6 in x 4.5 in x 1.75 in) TNT 12000 X-Ray Test Tools Fluke Biomedical 7

96020C and 96035B Diagnostic Ion Chambers 96020C 96035B Energy range 30 kvp to 150 kvp 30 kvp to 150 kvp for diagnostic measurements 20 kvp to 50 kvp for mammographic measurements Nominal volume 150 cm 3 ; 11.30 cm diameter by 1.5 cm thick active volume 15 cm 3 ; 3.96 cm diameter by 1.22 cm thick active volume Nominal sensitivity H60: 2.08 R/C x 10 7 R/C at 22 C and 760 mmhg (optimized for lowlevel image intensifier and cine measurements) L100: 2.0 R/C x 10 8 R/C at 22 C and 760 mmhg MV30 (PTB mammo point) 2.21 R/C x 10 8 R/C at 22 C and 760 mmhg (flat energy response suitable for conventional diagnostic radiography and mammography) Leakage current < 10 fa under normal bias conditions (300 V) Collection efficiency 95 % at 2,000 R/min 95 % at 5,000 R/min Wall material Composite graphite-filled thermoplastic Graphite-coated acrylic (methylmethacrylate) Window material 0.76 mm thick, graphite-coated polycarbonate Both entrance windows are made of 0.25 mm graphite-coated polycarbonate Window density 91 mg/cm 2 32 mg/cm 2 Active window area Collector plate Connector Calibration 100 cm 2, centered within the chamber body 0.8 mm thick graphite-coated acrylic plate, 10.80 cm in diameter; 2.16 cm x 2.85 cm guard region electrically isolated from collector area Each side of the chamber has a circular active window region centered 7.1 mm further from the BNC connector than the center of the chamber body; active window regions have an area of 12.32 cm 2 0.25 mm thick, centrally mounted, graphitecoated, polycarbonate plate, 3.18 cm, ± 0.01 cm in diameter; 1.27 cm x 0.89 cm guard region is electrically isolated from the collector area Side-mounted, triaxial, two-lug BNC connector Standard calibration performed Standard calibration performed at one diagnostic and one mammographic beam quality at H60 (NIST defined as 60 kvp, first HVL of 6 mm Al, homogeneity Calibration factors normalized to 22 C and coefficient of 94) 760 mmhg diagnostic unattenuated beam Calibration on diagnostic side of chamber is performed at M80 (NIST defined as 80 kvp, first HVL of 2.97 mm Al, homogeneity coefficient of 57) mammographic beam Calibration on mammographic side performed at Mo/Mo28 (NIST defined as 28 kvp, first HVL of 0.332 mm Al, homogeneity coefficient of 74.3) or MV30 (PTB defined as 30 kvp, first HVL of 0.337 mm Al) 8 Fluke Biomedical TNT 12000 X-Ray Test Tools

Ion chamber Units Effective range*** Resolution step size 15 cc R 100 µ to 20 µ 1 µ R/s 100 µ to 20 µ 1 µ R/m 5 m to 1200 m 50 µ R/h 100 m to 72 k 1 m R/f** 2 µ to 333 m 0.02 µ Gy 1 µ to 175 m 0.01 µ Gy/s 1 µ to 174 m 0.01 µ Gy/m 50 µ to 10.5 µ 0.5 µ Gy/h 1 m to 630 m 0.01 µ Gy/f** 0.02 µ to 2.9 m 0.2 µ 150 cc R 10 µ to 2 µ 0.1 µ R/s 10 µ to 2 µ 0.1 µ R/m 0.5 m to 120 m 5 µ R/h 10 m to 7.2 k 0.1 m R/f** 0.2 µ to 33 m 0.002 µ Gy 0.1 µ to 17.5 m 0.001 µ Gy/s 0.1 µ to 17.5 m 0.001 µ Gy/m 5 µ to 1050 m.05 µ Gy/h 0.1 m to 63 m 0.001 m Gy/f** 0.002 µ to 290 µ 0.02 n 150 cc low rate mode R/s 2 µ to 2* 0.1 µ R/m 0.1 m to 120* 5 µ R/h 2 m to 72 k* 0.1 m R/f** 0.04 µ to 33 m* 0.002 µ Gy/s 0.02 µ to 17.5 m* 0.001 µ Gy/m 1 µ to 1050 m* 0.05 µ Gy/h 0.02 m to 63 m* 0.001 m Gy/f** 0.4 n to 290 µ 0.02 n Electrical units C 1 p to 100 n 0.01 p A 1 p to 100 n 0.01 p Values for ion chambers are calculated using nominal sensitivities: 15 cc: 2.4 x 10 8 R/C, 150 cc: 2.4 x 10 7 R/C. *Very Low Dose Rate effective range at 5 % resolution steps. **At 60 f/s (1 to 120 frames/selectable). ***IEC 61674 effective range at 1 % resolution steps. ma/mas Specifications Measurement range Min Max Invasive mas (with shunt) ma/mas ranges* 0.00 99.99 100.0 999.9 1000 1999 Non-invasive mas (with clamp) ma/mas ranges 0.0 999.9 1000 3999 *mas measurements are fully auto-ranging, so values are display ranges only Accuracy Invasive mas (with shunt) ± 1 % TNT 12000 X-Ray Test Tools Fluke Biomedical 9

Configurations chart Mainframes TNT 12000WD Wireless Detector with mas TNT 12000WD Wireless Detector TNT 12000 DoseMate Dosimeter with mas TNT 12000 DoseMate Dosimeter Item # 3586807 3586829 3586787 3586779 3586841 3335763 3586754 3586570 3345931 3586543 3561890 TNT 12000D Wireless Display 3345954 Standard accessories AC Power Adapter 3548014 (2) AC Adapters/Chargers 3346048 Cable, Type A to Mini B USB 3346027 Cable, Mini A to Mini B USB 3346030 Test Stand 3586537 Plug, Connector, Triax 3551210 Triax Cable, Male to Male, BNC, 6 ft 3586644 ZigBee USB Dongle 3341333 HVL Filter Set 3264115 Multi-Prong Adapter 3549414 Adapter Stem 3264091 Test Lead Kit, 1 Set of Test Leads ma Cable Assembly, BNC (male to female) 3555490 1918780 ma Shunt Assembly 3586555 Connector, BNC (female) to Binding Posts Connector, BNC (female) Double Banana Plug with mas + TNT 12000 DoseMate + TNT 12000D Display + TNT 12000 DoseMate with mas + TNT 12000D Display 1938315 1633042 Customized Carrying Case 3586528 Customized Carrying Case 3586865 Customized Carrying Case 3346011 CD, DoseMate/TNT/mAs 3586667 Quick-Start Reference Guide 3557133 *Customized configurations also available. For more information, contact Fluke Biomedical. with mas + TNT 12000D Display TNT 12000 DoseMate with mas + TNT 12000D Display + TNT 12000 DoseMate + TNT 12000D Display + TNT 12000D Display TNT 12000 DoseMate + TNT 12000D Display 10 Fluke Biomedical TNT 12000 X-Ray Test Tools

Ordering information Item numbers/descriptions 3586807 with mas + TNT 12000 DoseMate + TNT 12000D Display 3586829 + TNT 12000 DoseMate with mas + TNT 12000D Display 3586787 with mas + TNT 12000D Display 3586779 TNT 12000 DoseMate with mas + TNT 12000D Display 3586841 + TNT 12000 DoseMate + TNT 12000D Display 3335763 + TNT 12000D Display 3586754 TNT 12000 DoseMate + TNT 12000D Display *Customized configurations also available. For more information, contact Fluke Biomedical. Optional accessories 2549992 Diagnostic Ionization Chamber, 150 cc 2550024 Diagnostic Ionization Chamber, 15 cc 2549741 CT Ion Chamber, 10 cc 2549734 CT Ion Chamber, 3.2 cc 3265786 Triax Cable, Male to Male, BNC, 20 ft 2118136 ma Cable Assembly, Male to Female, BNC, 20 ft (mas options only) 3586746 Clamp, Probe, AD/DC ma Leakage (mas options only) 3337356 TNT 12000 Ansur Test Automation Software Plug-In (TNT 12000WD only) Included with every TNT 12000 system TNT 12000 EXL add-in reporting software places measured values into customizable Microsoft Excel templates that can be used for records maintenance and reporting ZigBee USB dongle facilitates direct wireless interface between the detector instrument and the user s PC, negating the need for an additional readout device USB cable facilitates PC interface, Excel reporting, and Ansur test automation Customized carrying case specifically designed to maximize system portability TNT 12000 X-Ray Test Tools Fluke Biomedical 11

Fluke Biomedical. Better products. More choices. One company. About Fluke Biomedical Fluke Biomedical is the world s leading manufacturer of quality biomedical test and simulation products. In addition, Fluke Biomedical provides the latest medical imaging and oncology quality-assurance solutions for regulatory compliance. Highly credentialed and equipped with a NVLAP Lab Code 200566-6 accredited laboratory, Fluke Biomedical also offers the best in quality and customer service for all your equipment calibration needs. Today, biomedical personnel must meet the increasing regulatory pressures, higher quality standards, and rapid technological growth, while performing their work faster and more efficiently than ever. Fluke Biomedical provides a diverse range of software and hardware tools to meet today s challenges. Fluke Biomedical Regulatory Commitment As a medical test device manufacturer, we recognize and follow certain quality standards and certifications when developing our products. We are ISO 9001 certified and our products are: CE Certified, where required NIST Traceable and Calibrated UL, CSA, ETL Certified, where required NRC Compliant, where required Fluke Biomedical 6045 Cochran Road Cleveland, OH 44139-3303 U.S.A. Fluke Biomedical Europe Science Park Eindhoven 5110 5692EC Son, The Netherlands For more information, contact us: In the U.S.A. (800) 850-4608 or Fax (440) 349-2307 In Europe/M-East/Africa +31 40 267 5435 or Fax +31 40 267 5436 From other countries +1 (440) 248-9300 or Fax +1 (440) 349-2307 Email: sales@flukebiomedical.com Web access: www.flukebiomedical.com 2009 Fluke Biomedical. Specifications subject to change without notice. Printed in U.S.A. 11/2009 3585652A D-EN-N Modification of this document is not permitted without written permission from Fluke Corporation.