Universal flat-panel mount

Similar documents
LCD DISPLAY MOUNT

Universal flat-panel mount

INSTALLATION MANUAL SFM3

INSTALLATION INSTRUCTIONS

PWM-T210 Installation Instructions UNIVERSAL FLAT PANEL MOUNT

INSTALLATION MANUAL CTM-VESA

INSTALLATION MANUAL ELPMBUNI

INSTALLATION MANUAL PBC-UMS

INSTALLATION MANUAL PBL-UMP

PFW 6851 Display Wall Mount, Turn & Tilt 80 kg INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION MANUAL SP-CEIL-012

INSTALLATION MANUAL SFM2

PAM-200 Universal Projector Mount

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Planar FWMG-MXL INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

NOVA-EXT Versatile Projector Mount Model: NOVA-EXT

Dual Arm Tilt LCD Mount

INSTALLATION MANUAL FLAT LCD DISPLAY MOUNT MODEL

AST-2446 INSTALLATION INSTRUCTIONS

P4263TP. Installation Guide. Low-Profile Tilting Portrait Mount for Flat-Panels

INSTALLATION INSTRUCTIONS

PART #MSP-DCCST Flat Panel Tilt Mount

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

PBM-UNI Installation Guide

Full-Motion TV Mount - 47" to 90" Installation Guide

Installation Guide. Model VLS-TM1540. Universal Tilt/Pivot Wall Mount for use with Flat Panel Displays

Full Motion Gas Spring TV Wall Mount - 24" to 55" Installation Instructions

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

19 to 39 TV WALL MOUNT - FULL MOTION

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

Installation Instruction

TV WALL MOUNT ASSEMBLY GUIDE RF-TVMLPT01V2

INSTALLATION INSTRUCTIONS

MSP-DCCPGTU Large Screen Tilt Display Mount

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

USE AND CARE GUIDE FIXED LED / LCD TV WALL MOUNT (UNIVERSAL MOUNTING PATTERN, FITS VESA

Modular Video Wall System with Push-to-Pop-out and Anti-Theft Features VW401P. User s Manual

INSTALLATION INSTRUCTIONS

ECM Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

Installation Instructions PP-FCMA

STORM OUTDOOR TELEVISION MOUNT

AM500-U Installation Guide

Assembly Instructions for Model: VMPL3

Full-Motion TV Mount 36" to 65" Installation Instructions

SB-WM-ART2-L-BL SB-WM-ART2-XL-BL

PFW 6875 Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

Full Motion TV Mount - 23" to 42" Installation and Operating Instructions

PFW Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

INSTALLATION INSTRUCTIONS. PLASMA TV WALL MOUNT TILT Universal (RGTU-210) WARNINGS WARNING

Ultra-Thin LED/LCD TV Mount - 23" to 42"

INSTALLATION INSTRUCTIONS Flat Panel Static Wall Mount Model: GSM-111

SB-WM-ART1-M-BL. Weatherproof Universal Single-Arm Articulating Mount for Medium Displays INSTALLATION MANUAL

MPA-9000 Universal Ceiling Projector Mount Kit

MSP-DCCPGSU Large Screen Static Display Mount

Flat Panel Tilt Wall Mount (GPM-111)

Small Above Fireplace Pull-Down Full-Motion TV Wall Mount

Model MSPPWRTW Large Flat Panel Single Arm Wall Mount

TP4463. ASSeMBly INSTruCTIONS FLAT PANEL TV MOUNTING SYSTEM OPTION 1 OPTION 2 OPTION 3

LC6X4WTM Security Wall Mount with Tilt for up to 60" Flat Screens with VESA 600mm x 400mm or less

Tilting & Swiveling Plasma/LCD Flat Panel Wall Mount Installation Guide Model: A380SM

Monoprice Adjustable Tilt/Swivel Flat Panel Wall Mount Model MLB-109B/RLB-102B (PID# 4926)

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Ceiling Mount - 32" to 60" - Single Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE. Model:B60 RECESSED IN WALL MOUNT

Medium Flat Panel Dual Swing Arm Wall Mount JWD-V

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

MSP-WRTIDSKY1 Light Weight Suspended Ceiling Kit for use with Island Display Skybox

LC200WT Security Wall Mount with Tilt for up to 32" Flat Screens

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

GB-AVSTOR5 Ceiling Equipment Storage Box with Pipe Coupler

OB1U INSTALLATION INSTRUCTIONS. Interactive Flat Panel Over White Board Mount

INSTALLATION INSTRUCTIONS

Flat Panel Dual Swing Arm Wall Mount (FWD-110) MSP-SA

Showpiece Cabinet Integrated Stand For 32" - 52" LCD HDTV

LARGE FLAT PANEL DISPLAY STATIC MOUNT PST 2000 Series

INSTALLATION INSTRUCTIONS Medium Flat Panel Model MSP-SI1

Fixed Wall Arm. Installation Guide. Part number Rev E 2012 PolyVision Corporation All rights reserved

Tilting Flat Panel Wall Mount Installation Guide

HD installation guide

MONOPRICE. Above Fireplace Pull-Down Full-Motion TV Wall Mount. User's Manual P/N 27773

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

PFW 6870 Installation Guide Installationsanleitung, Guía de Instalacíon, Guida de Installazione, Guide d Installation, Installatie gids

INSTALLATION INSTRUCTIONS

QLF215 INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS

Medium Flat Panel Universal Interface Bracket (MSB-V)

Speaker Mount Center Channel Speaker Adapter (PAC-301)

INS T A L L A TIO N INS T R U C TIO N S. Ceiling Mount Track System

LC200DS2 Double Stud Dual Articulating Wall Mount for Flat Panel Screens up to 32" with up to 200mm x 200mm VESA Mounting Patterns

Transcription:

R I N S T A L L A T I O N M A N U A L Universal flat-panel mount LISTED E176225 3130 E. Miraloma Ave. Anaheim, CA 92806 Phone: 800 368-9700 Fax: 800 832-4888 www.mounts.com PREMIER MOUNTS 2004/ REV 00

Contents - Assembly drawing - Fine tune tilt adjustments - Flat panel list - Parts list - Checking thread depth - Finding the center of the flat panel - Positioning the mounting brackets - Securing the mounting brackets - Finding the wood studs behind the wall - Lateral shift adjustment - Securing the flat panel to the wall mount The wall structure should be capable of supporting a max weight of 160 Lbs., the weight of the flat panel. More than 160 Lbs the wall must be reinforced. Proper installation procedure by qualified personnel as outlined in the installations instructions must be adhered to. Failure to do so could result in serious personal injury. WARNING: Safety precaution measures must be practiced at all times during the installation of this product. Use proper safety gear and tools for the installation procedure to prevent personal injury. The entire installation instructions should be fully read and understood, including all of the safety symbols and safety precautions, before beginning installation. The installation instructions should be read, understood and followed to prevent personal injury or property damage. Keep these installation instructions in an easily accessible location for future reference. Indicates that the power plug is to be disconnected from the power outlet. Contact Premier Mounts for any questions Safety precautions must be taken at all times. Warning and caution in general A secured structure wooden stud wall must always support the weight or load of the flat panel. Always confirm the center of the wood stud before beginning the installation. Do not install in locations where there is vibration, movement or danger of impact. Failure to do so could result in flat panel cracking or falling from the wall causing damage and injury. Do not install near heater, fireplace, direct sunlight or air conditioning or any other source of direct heat energy. Failure to do so may result in damage to the flat panel and could cause a risk of fire. At least two qualified people should always perform the installation work. Injury and damage can result from dropping or mishandling the flat panel. Mounting structure recommended wood studs, solid-flat concrete. Use a minimum diameter of 5/16 x 2 ¼ lg concrete wedge anchors (commercially available). or a minimum diameter of 5/16 x 3 lg wood screws. - 2 -

Assembly drawing Dimensions are in Inches and (mm) 16.000 (406.4 36.000 (914.4) 16.000 (406.4) B H A 8.000 (203.2) G C L 8.000 (203.2) 19.000 (482.6) 21.000 (533.4) F C L 24.000 (616.97) E D C Description A. Wall plate G B. Mounting brackets C. Griplate D. Mounting hardware E. M6 x 30 (mm) Phillip screws H 1 F. Wood stud G. 5/16 x 3 Lag screws and flat washers 19.000 (482.6) H. Safety knobs Fine tune tilt adjustments 1. M5 Phillips screws for fine tension 2. M8 Hex nut coarse tension 2 NOTE: The 8 (mm) hex nut is for your coarse tension adjustment and the 5 (mm) screws are for your fine tension adjustment. - 3 -

Flat panel Dwin HD161: (6) M8 x 16 Samsung PPM63H3, HPN6336, SPK6315M, PPM63H1, HPL6315: (4) M8 X 30 ½ Nylon spacers LG Electronics MU60PLZ10, MU60PZ11B, MU60PZ12B,MU60PZ90V, DU60PZ60: (6) M8 x 16 NOTE: If your flat panel display is not listed, go to (page 7) to determine the thread pitch on your flat panel. - 4 -

Parts list NOTE: This wall mount is shipped with all proper installation hardware and components. Make sure that none of these parts are missing before beginning installation. If there are parts missing stop the installation and contact Premier Mounts. Actual screw size M4 x 16 (Qty 8) M6 x 20 (Qty 6) M4 x 25 (Qty 4) M6 x 30 (Qty 2) M5 x 12 (Qty 8) M5 x 16 (Qty 6) M8 x 20 (Qty 6) M5 x 20 (Qty 6) M8 x 25 (Qty 6) M5 x 25 M5 x 50 (Qty 4) (Qty 4) M8 x 30 (Qty 6) M6 x 12 (Qty 8) M8 x 35 (Qty 4) M8 x 70 (Qty 4) - 5 -

Parts list (con t) Nylon spacers and flat washers actual size NOTE: The nylon spacers may be staked to achieve proper spacing. 1/4" Nylon spacers (large) (Qty 6) 9/16" Nylon spacers (Qty 6) 1/2" Nylon spacers (large) (Qty 12) Nylon sleeves (Qty 4) 5/16" Flat washers (metal) (Qty 6) 1" Nylon spacers (Qty 6) 1/4" Nylon spacers (small) (Qty 6) - 6 -

Checking the thread depth on your flat panel 1. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the flat panel to make sure the inserts measure the same full depth and mark it. (see figure 1) 2. Locate the correct diameter screw for the thread insert. Compare your marking to the screws (supplied). If your selected screw is longer than the marking on the thread depth indicator DO NOT USE this screw. The screw length must not bypass the marking. Select another screw size (see figure 2 and 3). Until you find one that comes closest to your mark without going past. Figure 1 Inverted flat panel display Marking the depth Thread insert Thread depth indicator Figure 2 Screw Thread depth indicator Marking Figure 3 Screw Marking Thread depth indicator - 7 -

Parts list (con t) All of these parts are used to install the mounting bracket. Make sure that none of these parts are missing before beginning installation. If there are parts missing stop the installation and contact Premier Mounts. Level (1) Griplates (8) M6 x 12 Safety knobs (2) Wall plate (1) 5/16" flat washers (9) Mounting brackets (left & right) 5/16" x 3" Lag bolts (9) (used on wood studs only) M6 x 30 Lateral shift locking screws (2) Thread depth indicator (1) - 8 -

Finding center of the flat panel display WARNING : Proper installation procedure by qualified personnel as outlined in the installation instructions must be adhered to. Failure to do so could result in serious personal injury and possible damage to the flat panel. WARNING! INVERT THE FLAT PANEL AND PLACE IT ON A SOFT, FLAT SUFRACE TO PREVENT DAMAGE TO THE FLAT PANEL. USE A BLANKET, FOAM, ETC. FAILURE TO DO SO WILL RESULT IN DAMAGING THE FLAT PANEL. DO NOT LAY THE FLAT PANEL ON THE FLOOR WITHOUT ANY PROTECTION TO THE GLASS. FLAT PANEL IS HEAVY AND FRAGILE. AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL. Once the flat panel is inverted, use a measuring tape to find the center of your flat panel measuring from outside to outside of the chassis. See figure 1. Top of the flat panel Measuring tape C L Inverted flat panel Bottom of the flat panel Using a pencil lightly mark the center of your flat panel. See figure 2. Inverted flat panel Mark the center of the flat panel LC - 9 -

Positioning the mounting brackets Nylon spacers if Applicable (see chart) on page 4 CAUTION: Check the chart on page 4 and 5 to see if your flat panel needs nylon spacers. The nylon spacers provided, must be used. Failure to do so will result in damaging the flat panel. Install the nylon spacers to the mounting points on the flat panel see figure 3. NOTE: See chart (if the nylon spacers apply to your flat panel). Inverted flat panel Center mark Lay the left and right mounting brackets (stamped arrows facing out). See figure 4. Mounting brackets Bottom of the flat panel Arrows facing out - 10 -

Match the center of viewing guide with the center line you marked in step 1. See figure 5. LC Bottom of flat panel Align the mounting brackets Mounting bracket The mounting brackets are designed with a center of viewing guide on the side of them. See figure 6. Bottom of flat panel Center of flat panel Center of viewing guide - 11 -

Securing the mounting brackets DIMPLES M8 The Griplates have M4, M5 M6 and M8 hole patterns to fit the hardware that your flat panel requires. EXAMPLE: If your plasma uses M8 x 20 Phillip screws. Use the M8 mounting points. See figure 7 M5 M6 Pre install two (2) M6 x 30 (mm) Phillip pan screws to the bottom of the left and right hand side mounting brackets. Once the mounting brackets are aligned secure the Griplate to the flat panel. M4 NOTE: The dimples of the top plates have to be facing up and the bottom dimples must be facing down. Use (1) Griplate per mounting point. See figure 8. Phillips screw driver DIMPLES FACING UP DIMPLES FACING UP DIMPLES FACING DOWN Bottom of flat panel DIMPLES FACING DOWN CAUTION: Do not over tighten the mounting hardware. NOTE: Secure the two (2) M6 x 30 Phillip pan screws to the left and right mounting bracket. - 12 -

Finding the wood studs behind the wall structure Wood stud finder (commercially available) Mark the wall and the center of the wood studs. Using a (commercially available) wood stud finder, locate the 16" or 24" stud centers behind the wall. Once found, make a pencil marking on the center of the wood studs. See figure 9. NOTE: The wall plates have 16" and 24" mounting slot positions. (Look at the assembly drawing on page 3) CENTER OF VIEWING HEIGHT DESIRED Wood studs behind the wall structure Mark the nine (9) mounting slot openings Place the wall plate to the reference line and mark the nine (9) lag bolt mounting points through the wall plate slots on the wall. Level the wall plate with the reference arrow pointing up to the ceiling. See figure 10. Center of viewing mark Level - 13 -

Securing the back plate to the wall Drill nine (9) ¼" pilot holes to the marked wall. See figure 11. Drill gun (9) Pilot holes - 14 -

Level and secure the plate to the wall with the reference arrow facing up to the ceiling. Secure the plate using the nine (9) 5/16" lag bolts and flat washers (supplied). See figure 12. - 15 -

Securing the flat panel to the wall mount WARNING: AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL. Raise the flat panel with the LEFT and RIGHT mounting brackets secured to the flat panel and insert the top and bottom hooks from each bracket to the rods from the wall plates. See figure 13. TOP BOTTOM - 16 -

Make any lateral shift adjustment and lock it by tightening the two (2) M6 x 30 (mm) Phillips screws found on the bottom of the mounting brackets. CAUTION: Do not over tighten the M6 screws to the rods. See figure 14 Lateral shift M6 x 30 Lateral shift screw - 17 -

Securing the flat panel to the wall mount Tilt the flat panel and secure the two (2) M6 x 12(mm) safety knobs to each of the mounting brackets. See figure 15 M6 x 12 Safety knobs NOTE: To remove the display from the wall simply extend the display to its maximum tilt range, remove the two 6 (mm) safety knurl knobs push the flat panel back to it s flat position loosen or remove the two (2) M6 x 30 lateral shift screws and lift the unit of the wall. - 18 -

www.mounts.com PREMIER MOUNTS 2004-19 -