ISH-R150 MANUAL ROCKWELL HARDNESS TESTER OPERATION MANUAL

Similar documents
ISHR-M111 MAGNETIC ROCKWELL HARDNESS TESTER OPERATION MANUAL

ISH-MRD200 AUTOMATIC DIGITAL ROCKWELL HARDNESS TESTER OPERATION MANUAL

INSTRUCTION MANUAL PCE-HT 500

Greenslade & Company Rockwell Hardness Tester, Dial Type

INSTRUCTION MANUAL PCE-HT 550

Webster Hardness Tester

OPERATING INSTRUCTION

IIIIIC. Industrial Supply. USER MANUAl FOR ROCKWEll HARDNESS TESTER

MN-ISHB-B300-E ISHB-B300 BARCOL HARDNESS TESTER OPERATION MANUAL

INSPECTION AND CORRECTION OF BELLHOUSING TO CRANKSHAFT ALIGNMENT

Single punch tablet press. Operation Instruction

1. Turn off or disconnect power to unit (machine). 2. Push IN the release bar on the quick change base plate. Locking latch will pivot downward.

Digital Webster Hardness CDW-20 SERIES

VARIABLE SPEED WOOD LATHE

MN-ISHB-H131-E ISHB-H131 HYDRAULIC BRINELL HARDNESS TESTER OPERATION MANUAL

Fisher 667 Diaphragm Actuators Size 80 and 100

Due to possible damage in shipping, the vertical stop assembly has been removed from this machine.

Swivel Hoist Ring RIGGING ACCESSORIES. Color coded to distinguish between UNC (Red) and Metric (Silver) thread types.

Inventory (Figure 2)

HVS-1000DN. Digital Micro Vickers Hardness Tester. BMS Bulut Makina Sanayi Ve Ticaret Ltd. Şti.

MODEL T " HELICAL CUTTERHEAD INSTALLATION INSTRUCTIONS

Fisher 667 Diaphragm Actuator Sizes 30/30i 76/76i and 87

Manual 600MRD-L ROCKWELL HARDNESS TESTER

Swivel Hoist Ring Page 142

S E L E C T I O N. Arm Curl. User manual

Cut-True 16M Manual Paper Cutter

USER MANUAL & PARTS LIST MODEL 136A S/N:

#4500 BULLET SIZER & LUBRICATOR

STEEL RULE. Stock TRY SQUARE

YALE FIGURE 500 & 500R CLOSURE OPERATION AND MAINTENANCE INSTRUCTIONS

Operating, Servicing, and Safety Manual Model " Foot Shear CAUTION: Read and Understand

Maintenance Information

UNPACKING. Thank you for purchasing the Manual Capsule Filling Machine from KARISHMA PHARMA MACHINES.

CHEMINSTRUMENTS LABORATORY DRAWDOWN COATER LC-100 OPERATING INSTRUCTION

FD50-H SLIDING DOOR SYSTEM Installation Manual (Ceiling Mount Type for Pocket Door, with Dual Soft Close) Part No.FD50DHCP-PD

The Virgo/Libra Steam Engine

Table of Content. Machine Features and Functions. Specifications. Configuration and Working Principle 5. Machine Operation. Machine Adjustments

Tube Facing Tool.


Astro-Physics Inc. 400QMD Lubrication/Maintenance Guide

Power Train Lift Max. Capacity: 1,250 lbs.

Operating Instructions and Parts Manual SLT-1100 Jumbo Scissor Lift Table

MODEL H " BYRD SHELIX CUTTERHEAD INSTRUCTIONS

12 TON HYDRAULIC SHOP PRESS. Instruction Manual. Please read this instruction manual carefully before use.

REPAIR INSTRUCTIONS. Cat. No Cat. No MILWAUKEE ELECTRIC TOOL CORPORATION. SDS Max Demolition Hammer. SDS Max Rotary Hammer

Top spin Nr /

Side Winder R o u t e r L i f t.

Fig Remove chain cover plate bolts. Fig Remove hammer member. Fig Loosen set screws at base of 12-tooth sprocket.

Hullavator Gas Spring Replacement (simplified)

LINEAR MEASUREMENT. Prof.H M Prajapati & Prof. A R Sankhla

INSTALLATION INSTRUCTIONS ROPE ASSEMBLIES FATZER AG WITH HYEND SOCKETS FOR FROM. Kai-J. Thiem (THK) Martin Bechtold (BEM)

OPERATING INSTRUCTIONS MODULGRAV. Tel. +49 (0) Fax +49 (0) homepage:

Model 72D Twin Blade Rotary Wire Stripper

Operating Manual. for CUTTING, PERFORATING, BENDING SLB120

Item #28187 EASTWOOD BEAD ROLLER INSTRUCTIONS

IM-2 SE UNDERPINNER.!!! For your safety!!! Read the instructions manual carefully SAP: 0

MODEL T " SPIRAL CUTTERHEAD INSTRUCTIONS

3 BRACKET TO GUIDE ATTACHMENT. RIGHT END Figure 1. EXTENDED BRACKET (for doors taller than 8-8 ) SERIES 650. RIGHT END COTTER PIN Figure 6

8" BENCH SHEAR INSTRUCTIONS. Item #20198

MS25 OPERATION MANUAL

Elderfield & Hall, Inc., Kama Bandsaw AD 105S. Instruction Manual: Introduction to the Manual. General Precautions. Equipment. Machine.

MODEL T " SPIRAL CUTTERHEAD INSTALLATION INSTRUCTIONS

CONTENTS PRECAUTIONS BEFORE STARTING OPERATION PREPARATION FOR OPERATION CAUTIONS ON USE OPERATION

Pull-down clamps. No Low height clamping jaws, model Bulle

TOOLS AND INSTALLATION

TITAN-BIT KEY-CUTTING MACHINE INSTRUCTION MANUAL

Technical Documentation Lift Advanced

25 TONNE HYDRAULIC PRESS MODEL NO: AHP 26

VARIABLE SPEED WOOD LATHE. Model DB900 INSTRUCTION MANUAL

...thoroughly tried and tested!

S E L E C T I O N. Vertical Traction. User manual

Instruction Sheet RADIO FREQUENCY SYSTEMS. Install. Instr. for Microwave Parabolic Antennas 2.4 m (8 ft) No Rev.

Comparative Measuring Instruments

CarvLock HDLM6 Manual Machinable Jaw Vise

Motorized M3 AX7200 Rotary-Style Gasket Cutter Operating Instructions

Agricultural Mechanics and Technology Power Tool Safety Rules

Visit to see the full line of Ohaus Balances

INTERAPID Small Bench SHE.30 or SHE.35

Inventory (Figure 2)

DP-8 H. H. MØRCH. Instructions. Contents of the packing. Spatial requirements. Mounting the bush

Reliance SG800 Series Steel Water Gage Valves

MODEL T27451/T " & 20" SPIRAL CUTTERHEAD INSTRUCTIONS

Before use please read & understand this manual, paying particular attention to the safety instructions.

Dual Arm Tilt LCD Mount

INSTRUCTIONS FOR AIRFLEX 36WCBEP/36WCSEP WEAR PLATE REPLACEMENT USING GASKET SEALING TAPE

Removing and Replacing the Y-truck

20 TON HyDRAULIC SHOP PRESS with GRID GUARD 06/2015 INSTRUCTION MANUAL MODEL: KHP-20T-GG COPYRIGHT 2015 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

UNDERPINNERS CS 88 & CS 89 FOOT-OPERATED PNEUMATIC. Technical and User Manual. Version 1 au 12 / 01. Cassese / Communication

Thomas Scientific Swedesboro, NJ U.S.A.

FOLDING MACHINE PF-45A OPERATOR MANUAL 1. FUNCTION

25000 Series Lo-T TM Butterfly Control Valve Instructions

Horizontal and Vertical. Metal Cutting Band Saw MODEL: BS-115

Operating Manual Multi-Spot M22AL CD Stud Welding Machine

Lumber Smith. Assembly Manual. If you are having problems assembling the saw and need assistance, please contact us at:

I E D DIN EN ISO 9001 I T Y S Y S T E M. Reg. Nr

INSTRUCTION MANUAL Q-HYDRAULIC

Quick Set Dovetail Jig

VISES VISES JAWS CENTERING CLAMP BASE PLATE COMPACT PNEUMATIC VISE PAIR OF CLAMPS PAIR OF POSITIONING KEYS PAIR OF POSITIONING KEYS VISES

Technical T-A & GEN2 T-A GEN3SYS APX. Revolution & Core Drill. ASC 320 Solid Carbide. AccuPort 432. Page CONTENTS. Set-up Instructions 256

MODEL W1.0X305A(12 ) MODEL W1.0X610A(24 ) HAND BENDING BRAKE ASSEMBLY&OPERATING INSTRUCTION

Transcription:

MN-ISH-R15-E www.insize.com ISH-R15 MANUAL ROCKWELL HARDNESS TESTER OPERATION MANUAL

Attention Description This Instruction Manual shall be carefully read through in prior to use of the apparatus to clearly understand the detailed operation steps and special notes, and avoid apparatus damage or personal injury caused by improper use. Fastening tapes and cushion materials shall be carefully removed before installation and calibration of the apparatus. Never rotate the pressure selecting hand-wheel or turn-wheel when applying, keeping or removing the testing pressure. We are making continuous renovation in design of the hardness tester to improve its performance. Small change may be found in apparatus design without notification. 1 2 3 ISH-R15 Rockwell Hardness Tester is an universalized apparatus for Rockwell hardness determination. It can be used in the test of Rockwell hardness of various materials. The applying speed of test pressure can be adjusted by a buffering device, and the change of pressure is obtained by rotating a pressure selecting hand-wheel. Operation of the tester is quite easy, while the performance is stable and thus the tester can be used in a wide range. Working principle of the Rockwell hardness tester. The test procedure employs a conical diamond indenter or ball indenter of a certain diameter to press into the specimen, an initial test pressure P and a main test pressure P will be applied on the 1 indenter in sequence, and the total pressure (P + P ) will be kept 1 for a certain period, then the main pressure is to be removed, only the initial pressure will be left. A difference e between the indent depth h by this time and the indent depth h under the action of 1 initial pressure, is recorded as a permanent increment of indent depth. Every.2 mm of this increment represents a unit of Rockwell hardness. This is a quick test and only trivial indent will be caused, so it is widely used to determine the hardness of specimen. Calculation formula of Rockwell hardness test: HRA(C)= 1 - e/.2 H R B = 1 3 - e /. 2 e=h - h 1 Installation 1 Working conditions of the tester: Under ambient temperature, i.e. between 1-3 ºC; The relative humidity in test room shall not be over 65%; In an environment free from vibration; No corrosive medium in surrounding. 1 2

2 3 Tester unpacking: Open the packing box cover and take out all cushion materials. Remove the accessory box. Lift the bottom plate, unscrew the two (2) M 1 bolts under the bottom plate with a spanner, to separate the hardness tester from bottom plate, all steps shall be done in a safe manner. After unpacking, the tester shall be placed on a stable bench with levelness deviation less than 1 mm/m. A hole shall be drilled at an appropriate location on the bench (see figure 1) to enable the lifting screw to operate properly. Figure 1 After the hardness tester is properly placed (see figure 2), remove the top cover (1). Untie the fastening white gauze tape on the extension rod (25, figure 5), then promptly replace the top cover to prevent dust from coming into the tester. Open the rear cover (2) and remove the white gauze tape on moveable parts. Wipe off the anti-rust oil on the lifting screw and apply some thin lubricating oil instead. 1. Top Cover 2. Rear Cover 3. Centigrade Panel 4. Indenter Locking Screw 5. Indenter 6. Test Stock 7. Lifting Screw Cover 8. Turn Wheel 9. Pressure Applying Handle 1. Buffer Adjustment Cover 11. Pressure Selecting Handwheel 4 Installation of weights (figure 3): During weights installation the tester shall be at a test pressurefree state. Take the weights out of the accessory box and rub them clean. Rotate the pressure selecting hand-wheel (11) to position 588, take out the hanger (14) from rear cover, and lead the hanger into the hole on weight A (18), then tighten the two M1 nuts (19) at the end of hanger, hook the hanger onto the hoist eye (13) at the rear of beam (12), and put weight B (17) and weight C (16) on two resting forks (15) respectively. Then turn the pressure selecting hand-wheel a whole cycle and ensure that the weights' pins shall fall into the groove on the resting forks. 12. Beam 13. Hoist Eye 14. Hanger 15. Resting Fork 16. Weight C 17. Weight B 18. Weight A 19. Nuts Figure 2 Figure 3 3 4

5 6 Relationship between selected test pressure and applied weights is shown as follow: Scale HRA HRB HRC Test Pressure Graduation, N 588 98 147 Figure 4 Applied Weights Hanger + Weight A Hanger + Weight A + Weight B Hanger + Weight A + Weight B + Weight C How to fill oil in the buffering device (figure 4): The cylinder is filled with oil at the factory. In case of oil leakage during transportation, user can refill by himself as described below: loosen and take off two (2) screws on buffer adjustment cover (1), remove the cover and push the pressure applying handle (9) backward. Loosen nut (23), turn valve needle (24) counter-clockwise and fill #2 machine oil slowly through the hole on cylinder cover (21). The added oil shall be enough to let no empty suction sound be heard when pulling the pressure applying handle. Note: the oil level shall not exceed the joint surface between cylinder cover and cylinder body, otherwise oil will leak out. 2. Piston Rod 21. Cylinder Cover 22. Cylinder 23. Nut 24. Valve Needle 7 Main pressure applying speed adjustment: Install the conical diamond indenter (5), place a HRC test block of lower hardness on the test stock (6), then rotate turn-wheel (8) clockwise to cause the test stock move upward. A pointer on centigrade panel (3) will start to rotate as soon as the test block touches the indenter. When the pointer has rotated for 3 complete circles, stop turning of the wheel (8) and push the pressure applying handle backward, and watch the turning speed of the pointer. The time period from start to stop of turning of the pointer shall be between 4 6 seconds. If the turning speed is too fast, it can be adjusted by reducing the flow rate in buffering device, i.e. to rotate the valve needle clockwise and make the trial again till the time period falling in specified range. If the speed is too slow, the adjustment procedure is the same as above only the valve needle shall be turned counterclockwise. Operation 1 Preparation prior to the use: Surface of the specimen to be tested must be smooth and clean, free from dirt, scaling, indentation or significant marks resulted from machining. Scale, Indenter, Testing Pressure and Applicable Range for Rockwell Hardness Test. Minimum thickness of the specimen shall be larger than 1 times the depth of indenture. No obvious deformation shall be seen on back of the specimen after hardness test. The specimen to be tested shall be placed in stable state on top of the test stock. It shall be fixed during the test process. Ensure that the test pressure is perpendicularly exerted on the specimen. In case of a cylindrical shape specimen to be tested, the V type test stock shall be used and offset needs to be made to the values. Offset for cylindrical shape specimen shall be a positive value. 5 6

2 Scale A D C F B G H E K Indenter Diamond indenter conical angle: 12 spherical radius at vertex:.2 mm Ball indenter diameter: 875mm (1/16in) Ball indenter diameter: 3.175mm (1/8in) Initial Pressure (N) 98.7 Combined Pressure (N) 588.4 98.7 147 588.4 98.7 147 588.4 98.7 147 Applications hard alloy, carbide for surface quenched steel, hard steel sheet thin steel sheet, surface quenched steel quenched steel, tempered steel, hard cast iron cast iron,aluminum,magnesium alloy, bearing alloy, annealed copper alloy, mild steel sheet mild steel, aluminum alloy, copper alloy, malleable cast iron, annealed steel phosphorus iron, beryllium bronze, malleable cast iron aluminum, zinc, lead etc. bearing alloy, tin, hard plastics, and other soft materials The most commonly used scales for Rockwell hardness test are A, B and C. Hardness tester operation procedure: Choose a scale according to table 3 based on the rough hardness of the material to be tested. Rotate the pressure selecting hand-wheel clockwise to set the total pressure. When use the diamond indenter, press the head of diamond with middle finger and gently push it into the hole on indenter rod till it rests neatly on the supporting surface, then slightly tighten the indenter locking screw (4), and place the specimen on test stock (7). Rotate the turn wheel clockwise to let the lifting screw move upward, ensuring that the specimen to be tested slowly contact with the indenter with no impact, till the short pointer on the centigrade panel turn from the first step black point to the red one, and by this time the long pointer shall have passed three circles and point to position C (or position B 3 in case of HRB determination), which indicates that the initial test pressure of 98.7N is achieved. The deviation of long pointer shall not exceed 5 grades, otherwise the pointer shall not be allowed to turn back, instead that the test spot shall be changed to restart the operation. Rotate the graduation dial to set the pointer on position C. Push the pressure applying handle slowly backward and ensure that the main pressure shall be wholly exerted in 4 6 seconds. The total pressure holding time period is 5 seconds, after then pull the pressure applying handle steadily forward in 2 3 seconds to remove the main pressure and only the initial pressure is left. The value pointed by the long pointer on centigrade panel at this time shall be taken as the determined hardness value of the specimen (in case of HRB determination, value shall be read from the inner circle). Rotate the lifting wheel counterclockwise to lower the test stock. Repeat above procedure at various spots. No less than 5 spots shall be tested for each specimen (first spot will not be accounted). Number of test spots may be reasonably reduced in case of lot inspection. Adjustment of the hardness value display (figure 5).The accuracy of the tester is calibrated at factory. If any error is caused by improper handling during transportation, operator can make adequate adjustment but in prior to do that he shall thoroughly understand the structure and working principle of the tester apparatus. The procedure is as following: Remove the top cover. If displayed value is lower than the actual hardness of standard block, loosen M4 nut (26) and slightly turn in screw (28) clockwise, then tighten the nut and make the test again until the displayed value falls in the specified tolerance. If displayed value is higher, turn the screw counterclockwise. 7 8

Repeatability & Tolerance of Rockwell Hardness Display Value: Scale A B C Hardness of Standard Blocks 2HRA - 75HRA >75HRA - 88HRA 2HRB - 45HRB >45HRB - 8HRB Figure 5 Display Tolerance ±2HRA ±HRA ±4HRB ±3HRB 2 HRC - 7HRC ±HRC 2 HRC - 7HRC ±HRC Allowable Display a) Repeatablity.2(1-H) or b).8 Rockwell Unit.4(13-H) or b) 1.2 Rockwell Unit.2(1-H) or b).8 Rockwell Unit a) Where H is the mean hardness value. b) Take the larger one of these two values as basis. 25 Extension Rod 26 Nut 27 M4 Screw 28 Screw Maintenance 1 2 3 4 5 6 7 The operator shall operate the tester by following the instructions contained in this manual. Frequent calibration against standard blocks is necessary before and after actual tests. For tester not frequently used, several pre-tests shall be done on the standard blocks after the tester is turned on. During a hardness test, it is strictly prohibited to turn the pressure selecting hand-wheel when applying, keeping or removing the testing pressure. Use of the standard blocks can only be done on their working surface. A minimum distance of 3 mm between two successive test spots or between the center of indent and edge of the specimen is necessary. Life period of a standard block is limited to 2 years. When handling the hardness tester, the extension rod shall be fixed, and the weights and hanger shall be removed. The hardness tester shall be kept in clean state. After completion of testing procedure, the tester shall be covered with a dust cover. Hardness block and indenter shall be coated with antirust oil after use to prevent rust and corrosion. Periodical verification shall be done, at least once a year, on the tester so as to ensure its accuracy. Common trouble shooting. It is recommended that the user contact the manufacturer if problems occur with the tester. However, the following table may help the user to detect and solve some common problems. Problem Possible cause Suggested remedy The long pointer deviates from its zero point. Adjustment of displayed value may cause deviation of the long pointer. Refer to figure 5. Slightly loosen nut and turn M4 screw in small increment to align the pointer onto its zero point, then fix the screw and fasten the nut. 9 1

Extraordinary error occurs on display Appendix Minimum thickness of the specimen (mm) 1.Damaged indenter. 2.Wrong order of weights placement. 3.Friction between weights and inner wall of the tester body caused by unleveled installation of the tester. 4.The dust-proof cover is higher than the supporting surface of the lifting screw. 5.Wrong selection of total test pressure or indenter. 1. Replace diamond indenter or ball indenter. 2. Place weights according to figure 3. 3. Calibrate the tester with a leveling instrument 4. Lower the dust-proof cover to below the upper surface of the lifting screw and fasten the screw. 5. Select appropriate test pressure according to table 2. 1 Minimum thickness of the sample shall be larger than 1 times the depth of indenture. No obvious deformation shall be seen on back of the sample after hardness test. The relationship between minimum thickness of the sample and its hardness are shown in the following table. 2 Offsets for Rockwell hardness test when diameter of the specimen is less than 38 (25) mm. Hardness Value (HRC) (HRA) 2 25 3 35 4 45 5 55 6 65 7 75 8 85 9 Hardness Value (HRB) 2 3 4 5 6 7 8 9 1 Diameter of Cylindrical Specimen (mm) 6 1 13 16 19 22 25 32 38 3. 2. 3. 2. 2. Offsets (HR) to Rockwell Scale C & A 3. 2. 2. 2. 2. 2. Diameter of Cylindrical Specimen (mm) 6 1 13 16 19 22 25 5. 4. 5. 4. 3. Offsets (HR) to Rockwell Scale B 5. 4.5 4. 3. 2. 4.5 4.5 4. 3. 2. 4. 3. 3. 2. 3. 2. 2. 3. 2. 2. Hardness (HR) 11 12

Specification Hardness scale SPECIFICATION Preliminary test force Test force Display Stage elevation Load control Min. reading Max. workpiece height Max. workpiece depth Dimension Weight HRA, HRB, HRC, HRD, HRF, HRG 98N 588N, 98N, 1471N analogue manual manual HR 17mm 165mm (from the center of indenter) 52 16 7mm 6kg Standard Delivery Main unit Ø6mm flat anvil Ø15mm flat anvil V-type anvil Diamond indenter Ø875mm carbide ball indenter Hardness test block HRB85-95 Hardness test block HRC6-7 Hardness test block HRC2-3 13