How to choose the best DMM for your job Choosing the right digital multimeter (DMM) requires thinking about what you ll be using it for. Evaluate your basic measurement needs and job requirements and then take a look at special features/functions built into many multimeters. Think about whether you need to do basic measurements, or if you need the more advanced troubleshooting options offered by special features. Factors to consider: Your work environment (voltage level, types of equipment, types of measurements, applications) Specialty features/functions (capacitance, frequency, temperature, non-contact voltage, low impedance mode, min-max record, data logging, trending) Resolution and accuracy (6,000, 20,000, or 50,000 count resolution) Safety The increased occurrence and levels of transient overvoltages in today s power systems have given rise to more stringent safety standards for electrical measurement equipment. Transients that ride on top of power sources (mains, feeder or branch circuits) can trigger a sequence of events that may lead to serious injury. Test equipment must be designed to protect people working in this high-voltage, high-current environment. CAT I CAT II CAT III CAT IV Measurement category In brief Examples CAT I Electronic Protected electronic equipment Equipment connected to (source) circuits in which measures are taken to limit transient overvoltages to an appropriately low level Any high-voltage, low-energy source derived from a high-winding resistance transformer, such as the high-voltage section of a copier CAT II Appliances, PCs, and TVs Appliance, portable tools, and other household and similar loads Outlet and long branch circuits Outlets at more than 10 meters (30 feet) from CAT III source Outlets at more that 20 meters (60 feet) from CAT IV source CAT III MC panels, etc. Equipment in fixed installations, such as switchgear and polyphase motors Bus and feeder in industrial plants Feeders and short branch circuits, distribution panel devices Lighting systems in larger buildings Heavy appliance outlets with short connections to service entrance CAT IV Three-phase at utility connection, any outdoor conductors Service Entrance Service Entrance Service Entrance Meter Meter Underground Service Outbuilding Transformer Outbuilding Meter Underground Service Refers to the origin of installation, i.e., where low-voltage connection is made to utility power Electricity meters, primary overcurrent protection equipment Outside and service entrance, service drop from pole to building, run between meter and panel Overhead line to detached building, underground line to well pump
DMM selection chart Job functions Industrial maintenance technician Drives and motors specialist Plant engineer Electronic technician/engineer R & D engineer Electrical & Instrumentation technician Service engineer Electrical Lead Drive installer/ technician Industrial maintenance electrician Applications Logging: For unattended monitoring of signals over time, to detect intermittent problems. Working on Variable Speed Drives: Take accurate voltage, current and frequency measurements on the output side of the drive at either the drive itself or the motor terminals. Testing motor windings or contact resistance: Allows testing of resistance up to 50 ohms with one milliohm (0.001 ohm). Logging: For unattended monitoring of signals over time, characterize device performance. MIN-MAX-AVG: Function for signal monitoring. Useful for smoothing out noisy signals, estimating the percent of time a circuit is active, and determining the overall level of instability for the monitored signal. Working on Variable Speed Drives: Take accurate voltage, current and frequency measurements on the output side of the drive at either the drive itself or at the motor terminals. Industrial troubleshooting: All of the resolution and accuracy you need to solve more problems on motor drives, in plant automation, power distribution, and electromechanical equipment. Commercial electrician Light industrial maintenance Electrical maintenance-troubleshooting: Variety of commercial/industrial electrical troubleshooting, installation and maintenance. Residential electrician Electrical contractor Electrical maintenance troubleshooting: When you need to chase down ghost voltages, detect energized circuits before making a measurement, and when doing continuity, connections or basic wiring checks. HVAC technician/ installer Building engineer Residential HVAC maintenance: Lower voltage HVAC residential maintenance, installation and troubleshooting. Utility field services Meter service groups Fixed electrical installations In-house electricity meter testing: Involving meter sets and reconnects, capacitor checks, detection of absence or presence of voltage, and for continuity, connections or basic wiring checks.
Key features Logging Function with TrendCapture Low Pass filter for making measurements on VSD s Two terminal 50 ohm range with one milliohm resolution Recommended DMM Fluke 289 Fluke 289 FlukeView Forms Combo Kit Logging function with TrendCapture 0.025 % dc accuracy for bench meter performance Large easy to read dot matrix display Advanced MIN/MAX Fluke 287 True-rms readings 1000 V ac measurement range Electrical safety All inputs are protected to CAT III, 1000 V and CAT IV 600 V Inputs can withstand impulses in excess of 8,000 V and reduce risks related to surges and spikes Fluke 87V Fluke 87V/E2 Industrial Electrician Combo Kit Versatile meter combines precision, safety, and reliability Enables you to check more with wide measurement ranges Volts, amps, ohms, temperature, frequency, continuity, capacitance, and min-max Simple to use and has significant improvements over Fluke s original 70 Series with more measurement functions and a much larger display Fluke 179 Dual impedance meter for troubleshooting sensitive electronic or control circuits, as well as circuits that may contain ghost voltages VoltAlert: Integrated non-contact voltage detector Fluke 117 Fluke 117/322 Combo Kit CAT III 600 V A microamp function is included for flame sensor measurements down to 0.1 microamps Fluke 116 CAT III 600 V VCHEK LoZ low impedance measurement function Simultaneous audible continuity and voltage measurement Wide 600 V ac or dc automatic measurement range Fluke 113 CAT IV 300 V, CAT III 600 V
Meters designed for the way you work. Highest accuracy High-end industrial Intrinsically safe Field service Electrical Basic features 289 287 87V 87V EX 179 117 Counts 50000 50000 20000 20000 6000 6000 ATEX II 2G EEx ia IICT4 safety rating zone 1 and zone 2 True-rms readings ac+dc ac+dc ac ac ac ac Basic dc accuracy 0.025 % 0.025 % 0.05 % 0.05 % 0.09 % 0.5 % Wide bandwidth 100 khz 100 khz 20 khz 20 khz Auto/manual ranging / / / / / / Measurements Voltage ac/dc 1000 V 1000 V 1000 V 1000 V 1000 V 600 V Current ac/dc 10 A 10 A 10 A 10 A 10 A 10 A Resistance 500 MΩ 500 MΩ 50 MΩ 50 MΩ 50 MΩ 40 MΩ Frequency 1 MHz 1 MHz 200 khz 200 khz 100 khz 50 khz Capacitance 100 mf 100 mf 10 mf 10 mf 10 mf 10 mf Temperature +1350 C +1350 C +1090 C +1090 C +400 C db 60 db 60 db Conductance 50 ns 50 ns 60 ns 60 ns Duty cycle/pulse width / / / / Continuity/diode test Motor drive measurement VoltAlert, Non-contact voltage detection VCHEK LoZ: low input impedance Lo ohms Microamps Display Dot matrix display Dual display Analog bargraph Backlight Graphical trend display Data storage and exchange Min/Max recording/ time stamp Fast Min/Max 250 μs 250 μs 250 μs 250 μs Display Hold/Auto (Touch) Hold / / / / / / / / / / / / Relative Stand alone logging Readings memories 10,000 10,000 USB compatible interface Other features Automatic selection, ac/dc volts Real time clock Integrated holster Removable holster Separate battery/fuse access / / / / / / Power source Battery Battery Battery Battery Battery Battery Warranty and safety Warranty (years) Lifetime Lifetime Lifetime Lifetime Lifetime 3 Input alert Dangerous voltage indication EN61010-1 CAT III 1000 V 1000 V 1000 V 1000 V 1000 V 600 V EN61010-1 CAT IV 600 V 600 V 600 V 600 V 600 V
HVAC/R Field service Basic electrical Basic purpose General purpose Heavy duty 116 115 114 113 77IV 27 6000 6000 6000 6000 6000 3200 ac ac ac ac 0.5 % 0.5 % 0.5 % 2 % 0.3 % 0.1 % 30 khz / / / / / / 600 V 600 V 600 V 600V 1000 V 1000 V 200 μa 10 A 10 A 10 A 40 MΩ 40 MΩ 40 MΩ 60 kω 50 MΩ 32 MΩ 50 khz 50 khz 100 khz 10 mf 10 mf 10 mf 10 mf +400 C 32 ns / / / / / / / / / / / / Enhance your digital multimeter s capabilities with Fluke accessories. Go to www.fluke.eu for more information. Fluke. Keeping your world up and running. / / / / / Battery Battery Battery Battery Battery Battery 3 3 3 3 Lifetime Lifetime 600 V 600 V 600 V 600 V 1000 V 1000 V 300 V 600 V Fluke Corporation PO Box 9090, Everett, WA U.S.A. 98206 Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 www.fluke.eu 2008 Fluke Corporation. Specifications subject to change without notice. 05/2008 11426-eng Rev 01