Euro-C3/C5 (Euro Vista Fold Aluminum Door System) Installation Instructions

Similar documents
EURO (3876) Euro-C2 Installation Instructions Euro-Wall Systems, LLC

EURO (3876) Euro-C3/C5 Installation Instructions Euro-Wall Systems, LLC

C3 INSTALLATION GUIDE Euro Vista Fold Impact Rated

Superior by Design. Approved for use in Miami-Dade HVHZ Zones Florida Building Code Approved Product Approval FL FOLDING SLIDING STACKING PIVOT

Installation Materials Required: Tools Required: 6" self-adhesive flashing. Shims. 3-foot level 6-foot level Tape measure 1/8" drill bit

Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

E3 Hardware Installation Instructions & E3 System Installation Manual

INOVO 4-LITE SLIDING PATIO DOOR ASSEMBLY AND INSTALLATION INSTRUCTIONS

SERIES: CONFIGURATION: MOUNTING PACKAGE: 1200 Door-Door Frameless, sliding door

INOVO 2-LITE SLIDING PATIO DOOR

FOLDING DOOR - FOR FACTORY ASSEMBLED JAMBS WITH APPLIED SILL

I n s t a l l a t i o n I n s t r u c t i o n s S E N T I N E L S E R I E S 1 50 SLIDING GLASS DOORS

Pocket Door Installation Instructions

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

tile redi redi DOOR Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE:

1200 SERIES 2 PANEL DOOR rev.1 DETAILED INSTALLATION INTRUCTIONS

Series 7600 Installation Instructions Aluminum Multi-Slide Door (Pocketing)

Sliding Glass Door Assembly and Installation Guide

Heavy Wall Applied Stop Tube Frame and Door Installation

SLIDING TUB / SHOWER ENCLOSURE WITH STATIONARY 90º PANEL

ASSEMBLY AND INSTALLATION INSTRUCTIONS for Premium Aluminum and Premium Atlantic Aluminum Sliding Patio Doors (JII020)

Flashing Materials. Rough Opening Preparation

Chapter 9. Windows and Exterior Doors

STACKING MULTI-SLIDE DOOR SYSTEM

Installation Instructions for Vista Air Vertically Folding Walls

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

Atrium Patio Door Field Service Manual

1/4 FRAMELESS SLIDING DOOR FOR TUB OR SHOWER

2300 BI-FOLD INSTALLATION GUIDE

1/4 FRAMELESS SLIDING DOOR FOR TUB OR SHOWER

series 9500 top load bi4fold installation instructions

6400, 8400 and 9400 Series Sliding Patio Door

1/4 FRAMELESS DOOR WITH INLINE PANEL 1413A-1713A-1813A

NEW CONSTRUCTION PATIO DOOR INSTALLATION INSTRUCTIONS (WITH NAILING FLANGE)

Vinyl Windows and Doors Manufactured by Pella Corporation

1/4 FRAMELESS SLIDING DOOR FOR TUB OR SHOWER 4400A-4500A

Installing a Weiland Beefy Bifold

Thermally Broken Framing and Door Installation

Vinyl Windows and Doors

SUPREME. Sliding Folding Patio 6 Door Set. Assembly Instructions. T14 Set - (Approx. 14ft) T16 Set - (Approx. 16ft)

ICU TRACKLESS SLIDING DOOR

tile redi redi DOOR Redi Redi Swing Slide g TM TM...Opening Doors to Stunning Showers! TM TM SERIES: CONFIGURATION: MOUNTING PACKAGE:

Unit No. 4400, 4500 Classic Frameless Sliding Tub/Shower Enclosure INSTALLATION INSTRUCTIONS

Sliding Folding Patio 6 Door Set

Wood Hinged Patio Door Installation Instructions

INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS

Vinyl Sliding Glass Door Assembly Instructions

3-LITE PATIO DOOR INSTALLATION INSTRUCTIONS

Chapter 9. Windows and Exterior Doors

western window systems westernwindowsystems.com installation instructions non-pocket 2-1/4 panels

INSTALLATION INSTRUCTIONS

ESA-300 Full Breakout

4-lite Patio Door. Installation Instructions

Contemporary 3 Panel Classic 5 Panel French Panel

Curtain Wall Installation Guide

Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

Hardware, Track, Sill System & Weathersealing For Exterior Folding Doors

QCI0029 REV. 1 Page 1 of 11 Certified 07/06/05

PRODUCT: LOKI INSTALLATION INSTRUCTIONS. Product is covered by U.S. patents. For more information visit

Mira Premium Series Bi-Parting French Sliding Patio Door Installation Instructions

SLIDING GLASS DOOR ASSEMBLY INSTRUCTION Series 680/780

Storefront Installation Guide

VYTEX PREMIUM SLIDING GLASS DOOR. Table of Contents. Precautions and Safety 2. Tools Required...3. Inspect and Prepare Door...4

Please read and understand all instructions before beginning. These instructions cover impact and non-impact aluminum French Door 650/750.

GENERAL INSTALLATION GUIDELINES

ICU TRACK SLIDING DOOR

1. TOOLS + MATERIALS REQUIRED

GENERAL INSTALLATION GUIDELINES

Frameless Inline Door QCI5250

POCKETING MULTI-SLIDE DOOR SYSTEM

How To Measure Your Finished Opening

Retractable Screen Installation Instructions For Vinyl and Aluminum Clad and Wood In-Swing Hinged Doors (See separate instructions for sliding doors)

SERIES 3070-T MULTI-SLIDE ASSEMBLY & INSTALLATION INSTRUCTIONS

western series 9500 f loor load The Volume Program window systems westernwindowsystems.com bi fold installation instructions

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Sun Windows General Information New Construction Hinged Door Installation Instructions

Please read and understand all instructions before beginning. These instructions cover the non-impact aluminum sliding glass door.

SERIES 5001 SLIDING GLASS DOOR PATIO DOORS INSTALLATION GUIDE

Sun Windows General Information New Construction Sliding Door Installation Instructions H F

VINYL WINDOWS (new construction or replacement) page 2. VINYL PATIO DOORS pages WOOD CLAD WINDOWS (new construction).page 5 WOOD CLAD WINDOWS

UNIT No FRAMELESS PIVOT SHOWER DOOR

Frameless Inline Door With Return QCI5263

ESA-100 Fixed Sidelite/Non Breakout

Frameless Inline Door QCI5254

INSTALLATION INSTRUCTIONS FOR REPLACEMENT FORGENT WOOD GLASTRA WINDOWS RECOMMENDATIONS FOR COMMON INSTALLATION OF ALL REPLACEMENT WINDOWS.

Chapter 18. Interior Doors

Panel Assembly and Installation

Kocked Down with Ends Assembled

Therma-Tru Fiber-Classic and Smooth-Star Sliding Patio Door System

HR175 Sash Replacement Kit Installation Instructions

ESA-200 Fixed Sidelite

Frameless Fixed Panel Slider

SERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS

How To Install Windows: Nail-Fin Application

INSTALLATION INSTRUCTIONS FRAMELESS CONTINUOUS HINGE SHOWER ENCLOSURE QCI5233

INSTALLATION INSTRUCTIONS. UNIT No. 160/760 THIN-LINE SHOWER ENCLOSURE

ELEGANCE SHOWER DOOR/ENCLOSURE INSTALLATION INSTRUCTIONS. Style A Style B Style C Style D

InstallatIon InstructIons for 2-lIte PatIo Door unassembled

Transcription:

888.989.EURO (3876) www.euro-wall.com Euro-C3/C5 (Euro Vista Fold Aluminum Door System) Installation Instructions

STEP 1: OPENING PREP Jobsite Preparation Considerations Rough Opening 1. Ensure correct rough opening specifications: A) Measure according to signed Euro-Wall shop drawing B) Plumb opening C) Level opening D) Square opening 2. Make sure the frame header is designed to withstand the dead loads of all Panels including glass plus momentum and impact loading since it is a top-hung Panel system. Rough opening header must not deflect more than 3/16 (2 mm) when carrying the weight of the Panels according to hardware suppliers specifications. 3. Ensure the head of the Folding Panel system can be securely fastened to the header components of existing structural header beam. 4. Recommended wood framing for opening or a continuous plane of structural wood to maintain stability, ease of fastening and securing. Always Measure at Three Points and Select the Smallest Measurement Overview or Installation Proces NOTE: A MAXIMUM HEADER DEFLECTION IS 3 / 16 1. Caulk all connection points between the sill and the header using high quality water sealing caulk 2. Predrill screw bosses in the sill and header using a 11/64 drill bit 3. Line up milled holes in jam with header and sill and predrill jam holes as required to line up with screw bosses in header and sill 4. Verify that you have caulked the joints so that all connections are sealed 5. Screw 2 # 12 screws SS ( as provided ) into screw bosses. It is highly recommended that you use soap, bees wax or lubricant on the screws so the head does not strip out. It is recommended that you use a light impact screw gun which if used properly, will reduce the stripping out of the softer SS screws 6. Prior to installing the frame make sure that if you require a weep for the frame that you drill the weep using 5 /16 drill bit (At least 1 weep every 24 in length) If the frame is not embedded and the front of the sill is exposed the drilling should be on the front edge of the exterior location and should be drilled thru both walls in the sill so that water from both channels can weep out to the front and drain to the exterior 7. If the sill is and partially or fully recessed in the floor, then the weeps need to be drilled out at the bottom of the both channels in the aluminum extrusion. Note: A tubing system or under floor drain may be required. 8. This is a top hung system, the header must be plumb and level prior to installing, use level and laser if needed to verify that the frame is plumb and level before screwing in all screws. Use shims at every pre-drilled screw location. 9. Once you have verified the frame location, drilled the weeps (if required). 10. Prior to installing the frame you must caulk the sill using a figure 8 pattern so that there is always two rows of caulk under the sill. 11. Prior to installing the door verify interior heights from header to sill are the same throughout the system and that the jams, header and sill are plumb level and square 12. All holes drilled for screws should be vacuumed out and filled with sealant caulk to prevent water egressing under the sill 13. After all screws are installed, caulk should be spread over the top to seal, then (after inspection) the vinyl channel liner should be placed in the sill 14. Install the weatherstrip on the frame as shown in the install guide 15. Installing the doors: identify the door # 1 and adjust the hinges as need to that you can hang the panels. Verify that you have the proper gaps from both the header and sill on the first door before you connect door number 2 16. Hang door # 1 from the hanger hinge and connect to door number one using the proper hinges. See hinge layout for your door system 2

STEP 2: FRAME ASSEMBLY Assemble Bottom Corner NOTE: it is recommended to use screw wax to prevent screw from snapping NOTE: When joining two header tracks together do not butt joint - MUST be a 45 degree miter cut. When joining two sill tracks together do NOT butt joint - MUST be a 45 degree miter cut. Caulk and Seal all Joints Note that track insert is in place prior to screwing sill to jamb. Assemble Top Corner Jamb 3 / #10 x 2 (Square PH) Note: Do not use this screw chase Pre-caution: NOTE: it is recommended it is to use to use screw screw wax wax to to prevent screw from snapping 3

STEP 3: FRAME WEATHERSTRIPPING Apply Horizontal Frame Weatherstrip Slide Pile-Fin weatherstrip (non-adhesive) into the slot. Cut weatherstrip ends at 90 degrees Tip: In order to insert weatherstrip smoothly, apply paraffin wax in weatherstrip grooves. Apply Vertical Frame Weatherstrip Cut vertical weatherstrip ends at 45 degree angle to match horizontal weatherstripping NOTE: Apply minimal amount of clear silicone between 45 degree angled cut ends and horizontal weatherstrip r Sill liner to be installed after inspection sill Jamb Apply Weatherstrip on frame. In Florida see Product Approval Document on the FBC System 4

STEP 4: FRAME INSTALL AND PREP Frame Placement into Rough Opening Weephole 5/16 screw bit Detail A: sill Detail c: Header Detail B: Jamb Detail a: sill installation screw hole Note: Shown Exterior Folding 1. Ensure sill is plumb and level 2. Sill sag to be no more than 1/16 1/6 *(2mm) at at centre center span 3. Sill bow to to be avoided at at any location of of the the sill sill 4. 4. Anchoring Anchoring screws screws are are not supplied supplied by Eclipse Euro-Wall by Euro-Wall Architectural 5. 5. Envelope Envelope details details are are not not included included in in this this guide. guide. Please Please consult consult with with your your local local building building codes. codes. 6. In order to reach enhanced performance (>DP70), (>DP60), use extra screw line located in the shootbolt channel as per images for 6. In order to reach enhanced performance (>DP70), use extra screw line located in the shootbolt channel as per images for head jamb sill. head / jamb / sill. 7. Seal off all installation screw holes in frame with silicone. 7. Seal off all installation screw holes in frame with silicone. 5

Detail B: Jamb NOTE: 1. To accommodate for the wall pivot cup, it is recommended to pre-drill a 11/16 (17mm) diameter hole in the rough opening due to the protruding wall cups (1/2 or 12mm). 2. Bow of the jamb to be kept to a maximum of 1/8 (3mm). 3. It is recommended to use a continuous board (as alternate apply pieces) that will act as a back-up in the hollow jamb. 4. Seal off backside of the middle pivot cup(s) with silicone. NOTE: All multi-section headers and sills must be joined by a miter cut. Detail c: Header Euro-C3/C5 extra installation screw hole Note: 1. The screw supplied used 3 must (75mm) penetrate PH track at screw least 1 is 1/2 a suggested (38mm) into screw the size rough only. opening The final structural header screw used beam must that penetrate is to carry at the least accumulative 1 ½ (38mm) Panel into load. the rough The size opening of the structural bolt head should header not beam interfere that is with to carry any carrier the accumulative wheels. Panel load. The size of the bolt 2. The head material should used not interfere for insulating with any the carrier shim space wheels. should be non-expandable material. 2. The material used for insulating the shim space should be non-expandable 3. Avoid the head from sagging after panels are installed and after full roof load is in place. material. We recommend installing the header with a slight bow (crown), but not more than 1/8 3. Avoid the head from sagging after panels are installed and after full roof load is (3mm) over the full system length. in place. We recommend installing the header with a slight bow (crown), but not 4. For Florida product approved installations see fastener details in FL#15472R-1 Guide. more than 1/8 (3mm) over the full system length. 5. The maximum header deflection allowed is 3/16. 4. Anchoring screws are supplied by Eclipse Architectural. 6

STEP 5: INSTALL PANELS Determine Panel Sequence We suggest the panels are identified for the purpose of communicating the sequence 1 2 3 4 Clean header track and lubricate prior to hanging panels. Do not allow panels to hang or swing on only one hinge. Must secure panel or damage to hinge will result. Step Install a.7.2) Cup Install for Wall-Pivot Cup for Wall-pivot Note: 1. Installing sleeve for center jamb hinge. Place sleeve in pre-drilled hole in jamb. Use attached screw and screw it into substrate. 2. Make sure substraight is deep enough. Caution: Always support weight of Panel panels with flat/pry bar or similar tool when locating and securing any pivot or carrier vertical adjustment. 1. Seal off holes for Pivot Cups with silicone. 2. Insert the hinge cap into the Bearing Tube first and then slide hinge pin down to engage into wall-pivot cup. 3. Make sure sub straight is deep enough. 7

Note: To ensure proper operation of Folding Panel System, insert the hinge while aligning the slot in the hinge flap with the rib on the Bearing Tube. step Mounting A.7.3) the mounting Top Wall-Pivot the top wall Hinge Pivot to Hinge 1st Panel to 1st Panel 4/ 8-32 x ¾ (Phillips FH) Important hinge consideration: Position all hinges in a way that one pushes the hinge up as per arrow. Adjust Panel Height Adjust panel prior to operating Note: Adjust clearance between top of the panel to bottom of the head track to 3/16 by using a crescent 1/2 wrench or ratchet. Caution: Always support weight of Panel panels with flat/pry bar or similar tool when locating and securing any pivot or carrier vertical adjustment. Release door weight for adjustment 8

S U P E R I O R B Y D E S I G N step A.9Panel Adjust Panelwith Reveal with Jamb Adjust Reveal Jamb Jamb Recessed stile sill 5/32 (4 mm) Note: Note: Adjust and panel panel to to 3/8. 5/32 Clearance (4 mm) bydimension using a long shafted Phillips screw is driver as perposition. image. Clearance Adjust clearance clearance between between jamb jamb and is measured when panel in closed dimension is measured when panel is in closed position. Hanging Panel: Mounting the Top the Intermediate Carriercarrier to 2ndto Panel step A.10)2nd Hanging 2nd Panel: mounting top Intermediate 2nd Panel 6/ 8-32 x ¾ (Phillips FH) Note! Do not allow panel to swing or hang on one hinge only. Make sure to block bottom of panel and to level to opposing panel. Note: Adjust of the the panel panel to to bottom bottomof ofthe thehead headtrack tracktoto13/64 13/64 (5(5mm) mm)bybyusing usinga a1/2 flathead screw driver into the Adjust clearance clearance between between top top of socket wrench - right yellow shipping clip. rotation lifts and left rotation lowers. Hanging Panel: Connecting 2nd Panel topanel 3rd Panel step A.11)2nd Hanging 2nd Panel connecting 2nd to 3rd Panel 6/ 8-32 x ¾ (Phillips FH) Copyright 2011 DS Group & Eclipse Architectural 12/10-32x ¾ (Phillips FH) 9 33

Hanging 3rd Panel: Mounting the Top Intermediate Carrier to 2nd Panel Hanging 4th Panel: Repeat Previous Steps for Hanging Panels Before Moving onto the Next Steps, Make Sure the Following Checklist is Completed Step 1: Ensure the multipoint is operating smoothly. (if applicable) Step 2: Ensure equal reveal to left and right of the system. Step 3: Ensure vertical alignment (see page 7). Step 4: Ensure left / right panel alignment (see page 11). 10

STEP 6: PANEL WEATHERSTRIPPING Small Weatherstrip Large Weatherstrip No Weatherstrip Large Weatherstrip Profile Small Weatherstrip Profile Weatherstripping Weatherstripping. Install large P weatherstripping on all panels that have two (2) hinge leaves and panels with jamb hinge. Place small P weatherstrip opposite the large weatherstrip. DO NOT INSTALL LARGE WEATHERSTRIP BETWEEN THE HINGE LEAVES. 11

STEP 7: PANEL ADJUSTMENT Panel(s) Adjustment Left / Right Reference Photo #1 Reference Photo #2 Tools Needed for Adjustment 1: 3/8 drive ratchet with extension with a 1/2 socket (Reference Photo #2) 1: Phillips hand driver (not electric) #3 and #2 1: Shims Adjustment Instructions Step 1: The panel to frame gapping is factory set to 1/4. If adjustment needs to be made, the set screws on the plate at the pivot hinge need to be loosened (not removed) so that the panels can be moved left or right. The desired condition to adjust is with the doors closed. Using shims to set the spacing at the upper jamb hinge. Once desired spacing is established, retighten screws at plate in header. Repeat the same adjustment for the lower jamb hinge. The center jamb hinge will follow the adjustments made by the upper and lower jamb hinge. Step 2: Open and close the door to ensure proper gapping and verify screws are set. Once the desired gapping has been verified, install two (2) self-tapping screws in the header plate at the jamb hinge. Step 3: Adjust clearance to allow the door to operate without touching the sill. Ideally, 1/4 and verify by operating the door very slowly to verify no sill damage and proper operation. 12

STEP 8: PRODUCT CARE & INSTALLATION Attention: Contractor Product Care after Installation 1. Keep the plastic protection inserts on the sill at all times! Create a sturdy bridge to protect still during construction phase. In addition, place a bridge while system is in open position and protect the side jambs of the Folding Door frame from damage. 2. Protect the Folding Door system from the following: Stucco: Causes etching on aluminum clogs the track and damages the rollers. Drywall: Clogs the system tracks; gums up rollers. Duct tape: Some adhesives chemically react with the many finishes. Therefore, use tape such as 3m painter s tape, but do not leave on any surface for more than 7 days. 3. Instructions for the owner and general contractor: Do not have small children operate or play within the confines of the Folding Panel system. Do not force the Folding Door system; contact Euro-Wall if it is found to be difficult to operate. Apply protection bumpers if exterior handles contact the metal clad of the next Panel. Anchor Panel when in open position to prevent uncontrolled movement that might cause damage. Operating of the Folding Door System: 1. Open system according to the following sequence: A. Multipoint release (if applicable) B. Release Twinpoint(s) C. Slide Panels to open position starting with Panel that does not have an Astragal (if applicable) 2. Close system according to the following sequence: A. Slide Panels to close position starting with Panel that has an Astragal (if applicable) B. Lock Twinpoint(s) C. Close swing-panel with multipoint (if applicable) 13

Attention: Consumer / End User Recommended Product Care for End-User SAFETY TIPS: Do not have small children operate or play within the confines of the Folding Door System. Anchor Panels when in open position to prevent uncontrolled movement that might cause damage. Do not force the Folding Door System. Have a qualified installer remove Panels or hardware when required. Contact Euro-Wall if Panel is difficult to operate. (1-888-989-3876) Operating of the Folding Door System: Open system according to the following sequence: A. Multipoint release (if applicable) B. Release Twinpoint(s) C. Slide Panels to open position starting with Panel that does not have an Astragal (if applicable) Close system according to the following sequence: A. Slide Panels to close position starting with Panel that has an Astragal (if applicable) B. Lock Twinpoint(s) C. Close swing-panel with multipoint (if applicable) Note: To close the Folding Door system, slide / fold the stack of Panels one by one (perpendicular to the track). If applicable, rotate the swing Panel to the closed position, only when all Panels are in their closed position. Consult Euro-Wall Maintenance. Consult specific hardware Folding Door care and maintenance guide: Hinges: Wipe down the visible surfaces with warm soapy water on a soft cloth and then rinse off by wiping with a clean damp cloth. Twinpoint: Spray suitable lubricant, such as, CRC Marine 66, Innox or WD40 to sliding pin and lock cylinder. Use plastic tube (supplied with lubricant) to direct spray. Track and bearings: Apply white petroleum jelly (Vaseline) or equivalent, to inner lip of each side of head track. Use clean cloth. Distribute lubricant evenly along track. Ensure wheels and bearings receive sufficient lubricant. Wipe all contaminant from track surfaces with damp cloth and mild detergent, clean surfaces with clean soft cloth. Apply thin film for systems installed in severe environments by wiping surfaces of track with anti-corrosive substance, such as, CRC Marine 66, Innox, WD40 or Corrosion X. Hangers, pivots and brackets: Spray thin film to hangers, pivots and brackets with anti-corrosive substance, such as, CRC Marine 66, Innox or WD40. Wipe exposed surfaces with clean soft cloth soaked in warm soapy water; rinse clean before applying corrosive preventative. Frequency Carry out care procedures with the following minimum recommendations: General environments - every 3 months Marine, industrial environments, within 5 miles of a body of water and / or a pool area - every month. Regular maintenance is required for all hardware, even stainless steel, to keep manufacturer s warranty in place. Failure to provide proof of maintenance will void any warranty. 14