TIA-2000 Optical/Electrical Converter. Operating Instructions

Similar documents
TIA-1200 Optical/Electrical Converter. Operating Instructions

TIA-3000 Optical/Electrical Converter. Operating Instructions

TIA-4000 Optical/Electrical Converter. Operating Instructions

TIA-1200 Optical / Electrical Converter Operating Instructions

TIA-952 Optical/Electrical Converter. Operating Instructions

TIA-3000 Optical / Electrical Converter Operating Instructions

TIA-527 Balanced Optical/Electrical Converter. Operating Instructions

TIA-500 Optical/Electrical Converter Operating Instructions

LTX-5520 Electrical / Optical Converter Operating Instructions

TIA-525 Optical/Electrical Converter Operating Instructions

Edmund Optics SN Photodiode Amplifier Operating Instructions Terahertz Technologies Inc.

PDA-750. Photodiode Amplifier. Operating Instructions. Terahertz Technologies Inc. 169 Clear Road Oriskany NY 13424

Amplified High Speed Photodetectors

Non-amplified High Speed Photodetectors

Non-amplified Photodetectors

Amplified Photodetectors

80-MHz Balanced Photoreceivers Model 18X7

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Document Version 1.2

DC to 12-GHz Amplified Photoreceivers Models 1544-B, 1554-B, & 1580-B

1.5µm PbSe Power Detector

Broadband Step-Up Transformer. User Manual

DC to 3.5-GHz Amplified Photoreceivers Models 1591 & 1592

80-MHz Balanced Photoreceivers Model 18X7

PCO-7114 Laser Diode Driver Module Operation Manual

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

125-MHz Photoreceivers Models 1801 and 1811

Glass Electrode Meter

Line 6 L I M I T E D R E F URBISH E D (B-ST O C K) W A RR ANT Y

About JFW Industries, Inc.

SDI SPECTRADYNAMICS, INC. HIGH PERFORMANCE DISTRIBUTION AMPLIFIER OPERATING MANUAL

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

HP 86290B RF PLUG-IN GHz HEWLETT PACKARD

2.5 GHz 1310 nm Laser Model 1732

Instruction Manual MX-485-S Bi-directional RS485 Data Transceiver

MaxLite LED Self-Driven LiteBars

Oberebenestrasse Bremgarten Switzerland Tel Fax

INGAAS FAST PIN (RF) AMPLIFIED PHOTODETECTORS

SPM-50 RF Spectrum Power Meter PC Software User Manual

Directed Energy, Inc Oakridge Dr., Suite 100, Fort Collins, CO

WireMaster Coax BNC PN: Rev C 2/13

Broadband Current Probe Series Operation Manual

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

MODEL 3810/2 Line Impedance Stabilization Network

COOLED InGaAS DETECTOR HEAD MODEL 71887

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

15-GHz & 25-GHz Photodetectors Models 1480-S & 1481-S

TRANSDUCER IN-LINE AMPLIFIER

Agilent 83440B/C/D High-Speed Lightwave Converters

50 Ohm Components Brochure

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

Power Probe Model PP115

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

DATASHEET AND OPERATING GUIDE TCS Series Thermistors

Wilcom MODEL T136BSBZW CIRCUIT TEST SET. Operating Instructions

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Model 9305 Fast Preamplifier Operating and Service Manual

FIBEROPTIC Receivers Operator's Manual

Wilcom MODEL T136BGMZW CIRCUIT TEST SET. Operating Instructions

Advanced Test Equipment Rentals ATEC (2832)

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

Current Probe Fixture Instruction Manual

25-Gbit/s, 850-nm VCSEL

HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

OVA-50 Optical Variable Attenuator User s Manual

Wilcom MODEL T336B CIRCUIT TEST SET. Operating Instructions

AMP-13 OPERATOR S MANUAL

User s Guide ASSISTIVE LISTENING SYSTEMS

User Manual. Smart-UPS On-Line. Uninterruptible Power Supply. Isolation Transformer Models: SURT001 and SURT002

ModBox 850 nm 28 Gb/s NRZ 800 band ; 100 Mb/s - 28 Gb/s Reference Transmitter

Balanced Photoreceivers Models 1607-AC & 1617-AC

Broadband Current Probe Series Operation Manual

Warranty Terms & Conditions

Photonic Test and Measurement Equipment. Terahertz Technologies Inc.

Single Flex and Double Flex Couplings (i)

Series 3000 Model R-107A

INSTRUMENTS, INC. Model 2960AX Disciplined Quartz Frequency Standard 2960AX. Section Page Contents

SX204. Headphone Amplifier. Symetrix. Owner s Manual

HydroLynx Systems, Inc.

Master Reference Unit

LOG PERIODIC ANTENNA MODEL LPA MHz - 1 GHz

Model 3116 Double-Ridged Waveguide Horn

Radio Remote Controls Manual K Series

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

Table of Contents 9.0 WARRANTY. 1.0 Introduction Package Contents. 2.0 Safety Instructions Overview...003

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Additional JFW Brochures

80i-600A AC Current Probe

User s Guide TX92A. Miniature Temperature Transmitters. Shop online at omega.com

Instruction Manual Model M Switch, DPDT, Manual Select

SureCall TM CM dB Dual Band Universal Inbuilding Repeater

Model DB Disc Caliper Brake AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

Guide. Installation. Wilson Electronics, Inc. In-Building Wireless Amplifi er. Contents:

Classic Series Public Address Amplifiers C10 & C20 Models

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

RFTX-1 Installation Manual

NON-AMPLIFIED HIGH SPEED PHOTODETECTOR USER S GUIDE

AM95 Installation Guide

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

Transcription:

TIA-2000 Optical/Electrical Converter Operating Instructions Terahertz Technologies Inc. 169 Clear Road Oriskany NY 13424 Toll Free: (855) TTI-TEAM (876-8377) (315) 736-3642 FAX (315) 736-4078 E-mail sales@teratec.us 3/2015

Contents Introduction...1 Unpackaging and Inspection...1 Power Supply...1 Typical Setup...2 Operating Considerations...2 Typical Frequency Response...3 Typical Spectral Response...3 Specifi cations...2 Service/Warranty Information...5

Introduction The TIA-2000 Optical to Electrical Converter is a wide-band detection system for fi ber optic applications. With a typical bandwidth of DC to 20 GHz, it accurately provides an electrical replica of the optical signal presented to it. It is intended to drive a 50 ohm cable terminated in its characteristic impedance. The unit is equipped with an InGaAs/InP detector that is responsive in the wavelength range of 1250-1625 nm. The TIA-2000 is provided with an FC/UPC fi ber optic receptacle. Other fi ber optic connectors can be provided on request. The output signal is presented to a type K SMA female connector. Unpacking and Inspection Prior to shipment this instrument was inspected and found to be free of mechanical and electrical defects. Upon acceptance by the carrier he assumes responsibility for its safe arrival. After unpacking, examine the unit for any evidence of shipping damage. Should you receive this instrument in a damaged condition, apparent or concealed, it must be noted on the freight bill or express receipt and signed by the carrier s agent. Failure to do so could result in the carrier refusing to honor the claim. Upon fi ling a claim TTI should be notifi ed. Power Supply Each unit comes equipped with a 9 V regulated power supply that provides power to the unit. Simply plug the power supply output cable into the receptacle located beneath the FC fi ber optic connector. It is recommended that the user never attempt substitution of this unit with any other power supply. Reverse polarity or voltages other than 9 Volts may irreparably damage the unit. The power supply can be used with mains of either 120 or 240 VAC, 50-60 Hz. Several replaceable power plug adaptors are supplied for use in various countries. Page 1

Typical Setup of the TIA-2000 K Connector On Power Off Model TIA-2000 O/E Converter FC Connector User Supplied RF Output Cable - 50 Ohm Signal Ω Operating Considerations The TIA-2000 is comprised of a fiber coupled InGaAs detector coupled with a reverse bias voltage network. The ouput of the diode is brought out to a type K female SMA connector. Light falling on the detector generates a positive-going proportional current. This current, multiplied by the load impedance produces a voltage that is proportional to the light incident on the detector surface. Normally the unit is used to drive a coaxial cable, this cable should have a 50 ohm characteristic impedance and be terminated with a 50 ohm load at the oscilloscope or other measuring device to be used. Typical optical return loss is 35 db and is caused primarily by the FC/PC connector employed. If higher return loss is needed, The unit may be optionally equipped with singlemode angled PC connectors for ORLs of around 52 db. Warning! No voltage should be present at user interface or damage to the unit may occur. Page 2

Relative Power Response {db} Typical Frequency Response The bandwidth of the TIA-2000 is from DC to typically 20 GHz (-3 db ). Refer to the following Bode plot Frequency {GHz} Spectral Response The approximate relative response curves of the detectors employed is as shown below. Note that these are reesentative curves and do not necessarily correspond to the exact response on the particular detector in use. Page 3

TIA-2000 Specifications Detector Type InGaAs (900-1700nm) Current Responsivity 0.8 A/W @ 1550nm Typical Maximum Linear Input Power 3mw Maximum Input Power without Damage 10mw Bandwith-(3dB) DC to 20 GHz Typ, 18 GHz min. Output Impedance 50 Ohms Output Connector Type K SMA Female Fiber Optic Input Connector FC/UPC or FC/APC Input Numerical Aperture 0.11 (9/125μ Singlemode Optical Fiber) Optical Return Loss >35dB, >52dB with APC Connection Electrical Return Loss 10 db Power Universal Power Supply Dimensions 1.2 W x 2.5 L x 1.3 H ( 30.5mm x 63mm x 33mm) Weight 5.6 oz (0.16Kg) LED Annunciators Provided Power On Operating Temperature Range 0-40 C Standard Warranty Two Years, Component and Workmanship, 30 Day Satisfaction Guarantee Accessories Supplied Transit/Storage Case, Operating Manual, Universal Power Supply TTI reserves the right to change specifi cations without notice. Page 4

LIMITED WARRANTY TERAHERTZ TECHNOLOGIES INC. ( TTI ) WARRANTS THAT TO THE FIRST PURCHASER, FOR A PERIOD OF TWO YEARS FROM THE DATE OF RECEIPT, THAT THIS PRODUCT ( THE PRODUCT ) WILL BE FREE FROM DEFECTS IN MATERIALS AND MANUFACTURING. THE FOREGOING WARRANTY IS THE ONLY WARRANTY, EXPRESS OR IMPLIED, GIVEN BY TTI, I.E., THERE IS NO WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. TTI HEREBY DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY OTHER THAN THE WARRANTY IN THE FIRST SENTENCE TO THE FULLEST EXTENT PERMITTED BY LAW.THE SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY IS REPAIR OR REPLACEMENT AT TTI S OPTION OF ANY PRODUCT THAT PROVES TO BE DEFECTIVE IN MATERIALS OR MANUFACTURING WITHIN TWO YEARS OF RECEIPT OF THE PRODUCT. NOTE: THIS WARRANTY DOES NOT APPLY TO ANY PRODUCT WHICH HAS BEEN SUBJECT TO MISHANDLING, MISUSE, OR SERVICE BY UNAUTHORIZED PERSONNEL OR TO ANY PRODUCT WHICH HAS BEEN DAMAGED, MODIFIED, ALTERED OR TAMPERED WITH. TO THE FULLEST EXTENT OF THE LAW, TTI DISCLAIMS ALL LIABILITY FOR ANY OTHER DIRECT, INCIDENTAL OR CON- SEQUENTIAL DAMAGES ALLEGED TO BE CAUSED BY A DEFECTIVE PRODUCT, I.E., TTI WILL NOT BE RESPONSIBLE FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OTHER THAN THE COST OF REPLAC- ING THE PRODUCT OR ANY OTHER MONETARY DAMAGE SUCH AS LOST WAGES OR PROFITS CAUSED BY ANY USE, ATTEMPTED USE OR INABILITY TO USE THE PRODUCT. NOTE: BY USING THE PRODUCT, YOU AGREE THAT REPAIR OR REPLACEMENT AT TTI S OPTION WILL FULLY SATISFY TTI S WARRANTY OBLIGATION TO YOU, WHETHER IN CONTRACT, TORT, NEGLIGENCE, STRICT Repair Information Products manufactured by Terahertz Technologies Inc. are designed and fabricated to provide reliable performance. However, in the event that service is required, both telephone technical assistance and factory repair services are available. Call (315) 736-3642 for information. For IN-WARRANTY REPAIRS, call us to obtain a Returned Material Authorization number, (RMA Number). All products are to be returned to TTI with freight charges pre-paid. Those products sent under warranty will be returned to our customers pre-paid. We cannot be responsible for returned products that do not reference the TTI RMA number. For OUT-OF-WARRANTY repairs, services are billable for both time and materials. Calibration - This is a qualitative measurement device. No calibration is required or necessary. Page 5