Radio Frequency Exposure Test Report

Similar documents
Radio Frequency Exposure Test Report

RF Exposure Evaluation Declaration

RF Exposure Evaluation Declaration

Report On. Radio Frequency Exposure Testing of the Winland Electronics, Inc. EnviroAlert Electronic Multi-Zone Environmental Alarm System

CE RF Exposure Report

CE RF Exposure Report

Test Certificate. given the measurement uncertainties detailed in Elliott report R Summit Data Communications. Model SDC-MSD40NBT

CE RF Exposure Report

Health Test Report. Report No.: AGC EH01 EN 62311:2008 EN 50566:2013. Attestation of Global Compliance (Shenzhen) Co., Ltd.

Report On. RF Exposure Assessment of the Sepura plc SRG3900 with AQHB Antenna. FCC ID: XX6SRG3900UW Industry Canada ID: 8739A-SRG3900UW

IC RF Exposure Report

EN 50371: 2002 TEST REPORT

RF-EXPOSURE ASSESSMENT REPORT

TEST REPORT. Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF. FCC Part 15 Subpart E (UNII) Summit Data Communications Inc SDC-MSD30AG

Test Certificate. given the measurement uncertainties detailed in Elliott report R Summit Data Communications. Model SDC-SSD40NBT

Report No.: 063L107-RF-CE-P14V02-2. Test Report. MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

RF Exposure Evaluation Declaration

RF EXPOSURE REPORT. Sagemcom 250 route de l empereur, Rueil Malmaison,92500, France

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,

Honeywell, Automation and Control Solutions

EN RF Test Report

RF EXPOSURE REPORT. ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

FCC TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

Test Certificate. given the measurement uncertainties detailed in Elliott report R Summit Data Communications.

RF Exposure Evaluation Declaration

APPLICATION FOR CERTIFICATION On Behalf of Futaba Corporation Radio Control Model No.:T10CG-2.4G FCC ID:AZPT10CG-24G Brand : Futaba

FCC 47 CFR PART 15 SUBPART B

SAR REPORT. TEST STANDARDS: FCC Part 15 Subpart C Intentional Radiator. ARRIS Model Spectrum 110A Set Top Box With Bluetooth (DSS) and RF4CE (DTS)

TEST REPORT. Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF. FCC Part 15 Subpart E (UNII) Xirrus Model(s): XN4

RF Exposure Report. Address: Building 24 (floors 1,3,4,5) and 28 (floors1-4) Central Science and Technology Park,Shennan Rd, Nanshan, Shenzhen,China

RF Exposure Report SA160715C03. Report No.: PY FCC ID: EX6150v2. Test Model: Received Date: Jul. 11, Test Date: Jul. 15 ~ Aug.

EN 62479:2010 ASSESSMENT REPORT WIN CHANNEL ELECTRONICS (HK) CO., LTD

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

Table of Contents. 1. GENERAL DESCRIPTION EUT General Information Testing Location...1

RF Exposure Report. Keilaranta 1, Espoo, Finland

Test Certificate. Summit Data Communications Model SDC-WB40NBT

Nemko-CCL, Inc West Alexander Street Salt Lake City, UT

DFS TEST REPORT. ADDRESS: 6F.-2, No.68, Liancheng Rd., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.)

IC Reassessment Test Report

RADIO TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

EN Test Report

IC Reassessment Test Report

ENGINEERING TEST REPORT # C LSR Job #: C-2411 Compliance Testing of: RM186-SM

ETSI EN V1.4.1 ( )

EU Standards dedicated Mobile and Base Station

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

EN EMF REPORT For. Two way radio Model No.: RT-5R

Electric Imp, Inc. IMP003-FCC FCC :2014. Report # ELIM NVLAP Lab Code:

EMF ASSESSMENT REPORT

EMF Test Report: Ericsson Radio 2205 B46

TABLE OF CONTENTS 1 GENERAL INFORMATION Identification of the Testing Laboratory... 3

RF Exposure Assessment Report (FCC ID: 2AD8UAZRBRH1)

FCC C2PC Test Report

Intertek Testing Services ETL SEMKO

RADIO TEST REPORT (AS/NZS 4268)

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 7 CERTIFICATION TEST REPORT FOR g WIRELESS LAN + BLUETOOTH PCI-E MINI CARD

Report No: R-RFCEP14V02. Test Report. For:Intel

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to

Measurements of Exposures Around Vodafone New Zealand Limited Cellsites from June 2012 to May 2013

FCC TEST REPORT (15.407)

Report No.: R-RFCEP14V01. Test Report

RADIO TEST REPORT (AS/NZS 4268)

RADIO TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

EMC Test Data. Radio Test Report R Summit Data Communications SDC-MCF10G. Test Report R76253 Rev 3.0. Revision History.

AN4378 Application note

RF Exposure Report. Report No.: SA180206E02 FCC ID: 2ACH3UKAZA2A0. Test Model: UKAZA2A001. Received Date: Feb. 06, Test Date: Feb.

TEST REPORT. Covering the DYNAMIC FREQUENCY SELECTION (DFS) REQUIREMENTS OF. FCC Part 15 Subpart E (UNII)

RF EXPOSURE REPORT. For. Model: SVI Trade Name: BOSCH

FCC Test Report. : ASE Group 4F,No 133, Sec 4, Mingsheng E Rd, Songshan Dist, Taipei, Taiwan

ETSI EN V1.3.1 ( )

This is a preview - click here to buy the full publication

Medtronic MiniMed TEST REPORT FOR. GST3 Glucose Sensor Transmitter, MMT-7763A. Tested To The Following Standards:

Honeywell, Automation and Control Solutions

XBee Series 2 OEM RF Module Model No.: XBEE2 FCC ID: OUR-XBEE2. Applicant: MaxStream, Inc. 355 South 520 West Suite 180 Lindon, UT 84042

SERIES K: PROTECTION AGAINST INTERFERENCE

ETSI EN V1.3.1 ( )

Test Report. Applicant ASUSTeK COMPUTER INC. 4F, No. 150, Li-Te Rd., Peitou, Taipei, Taiwan. Date of Receipt Jan. 28, Issued Date Mar.

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

FCC TEST REPORT (WLAN )

Report No: 073L039-RFCEP17V01. Test Report. Applicant MICRO-STAR INTL Co., LTD. No. 69, Li-De St., Jung-He City, Taipei Hsien, Taiwan, R.O.C.

FCC Test Report. Report No.: RF170922C07 FCC ID: 2AGDE-WRT3061. Test Model: WRT3061. Received Date: Sep. 22, 2017

ETSI EN V1.1.1 ( )

FCC CERTIFICATION TEST REPORT

FCC 15B Test Report. : Bluetooth 4.2 Dual Mode USB HCI Module (Refer to item for more details) (Refer to item for more details)

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to

ETSI EN V1.1.1 ( )

CE Radio Test Report

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

Test Report. Product Name: Wireless 11g USB Adapter Model No. : MS-6826, UB54G FCC ID. : DoC

TRANSMITTER MODEL: KAS-2030M

Applicant : FIC (First International Computer, Inc.)

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: MPE TEST REPORT

ETSI EN V1.1.1 ( ) Harmonized European Standard (Telecommunications series)

EMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

FCC DFS Test Report. : Wireless abgn + BT4.1 intelligent module

FCC Part 15 EMI TEST REPORT of

Report No: R-RFCEP38V01. Test Report

Test Report. Wireless 11g + Bluetooth Combo MiniPCI Card. Applicant MICRO-STAR INT L CO., LTD No.69,Li-De St,Jung-He City,Taipei Hsien 235,Taiwan

IC Test Report. : 3147A-BT900US : Intelligent BT4.0 Dual Mode USB Dongle

ETSI EN V1.1.1 ( )

Transcription:

Radio Frequency Exposure EN 62311 January 2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0Hz 300GHz) (IEC 62311:2007, modified) Model: SDC-MCF10G COMPANY: REPORT CREATED BY: Summit Data Communications 526 South Main St. Suite 805 Akron, OH 44311 Elliott Laboratories LLC an NTS Company 41039 Boyce Road. Fremont, CA. 94538-2435 REPORT DATE: March 23, 2012 TOTAL NUMBER OF PAGES: 14 PROGRAM MGR / QUALITY ASSURANCE DELEGATE / TECHNICAL REVIEWER: FINAL REPORT PREPARER: Mark E Hill Staff Engineer David Guidotti Senior Technical Writer This report and the information contained herein represent the results of testing test articles identified and selected by the client performed to specifications and/or procedures selected by the client. National Technical Systems (NTS) makes no representations, expressed or implied, that such testing is adequate (or inadequate) to demonstrate efficiency, performance, reliability, or any other characteristic of the articles being tested, or similar products. This report should not be relied upon as an endorsement or certification by NTS of the equipment tested, nor does it represent any statement whatsoever as to its merchantability or fitness of the test article, or similar products, for a particular purpose. This report shall not be reproduced except in full File: R86885 Page 1

REVISION HISTORY Rev# Date Comments Modified By - 03-23-2012 First release File: R86885 Page 2

TABLE OF CONTENTS REVISION HISTORY... 2 TABLE OF CONTENTS... 3 SCOPE... 4 OBJECTIVE... 4 STATEMENT OF COMPLIANCE... 5 DEVIATIONS FROM THE STANDARDS... 5 EQUIPMENT UNDER TEST (EUT) DETAILS... 5 GENERAL... 5 OTHER EUT DETAILS... 5 EN 62311 ASSESSMENT METHODS... 6 EN 50383 EVALUTATION METHODS... 6 ANTENNA REGION... 6 PREFERRED EVALUATION METHODS... 7 FAR FIELD CALCULATION... 7 RADIATING NEAR FIELD... 7 REACTIVE NEAR FIELD... 8 LIMITS... 8 MULTIPLE TRANSMITTERS... 8 EVALUATION RESULTS... 9 SEPARATION DISTANCE... 9 LIMIT... 9 CALCULATIONS... 9 RESULT SINGLE TRANSMITTER... 10 MEASUREMENT UNCERTAINTIES... 11 APPENDIX A TEST EQUIPMENT CALIBRATION DATA... 12 APPENDIX B TEST CONFIGURATION PHOTOGRAPHS... 13 END OF REPORT... 14 File: R86885 Page 3

SCOPE The European Committee for Electrotechnical Standardization (CENELEC) publishes standards regarding the evaluation of the rf exposure hazard of wireless communications devices. An evaluation has been performed on the Summit Data Communications model SDC-MCF10G, pursuant to the relevant requirements of the following harmonized EN standard(s) covering essential requirements under article 3.1 of the R&TTE Directive: EN 62311 January 2008 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0Hz 300GHz) (IEC 62311:2007, modified) The evaluation was performed in accordance with the standard and the following document(s): Council Recommendation 1999/519/EC of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0Hz to 300 GHz) (Official Journal L199 of 30 July 1999). OBJECTIVE The objective of the manufacturer is to comply with the harmonized standards identified in the previous section. File: R86885 Page 4

STATEMENT OF COMPLIANCE The evaluation of Summit Data Communications model SDC-MCF10G, in the configurations detailed within this report, complied with the relevant requirements of EN 62311. Maintenance of compliance is the responsibility of the manufacturer. Any modifications to the product should be assessed to determine their potential impact on the compliance status of the device with respect to the standards detailed in this test report. DEVIATIONS FROM THE STANDARDS No deviations were made from the published requirements listed in the scope of this report. EQUIPMENT UNDER TEST (EUT) DETAILS GENERAL The Summit Data Communications model SDC-MCF10G is an 802.11abgn (1x1) + Bluetooth 2.1 radio module. As it has only one transmit chain, it does not support MIMO operation, but it does support SISO. Company Model Description Serial Number Summit Data SDC-MCF10G 802.11bg - Communication module OTHER EUT DETAILS From ADT report RE950331L08A, dated Apr. 14, 2008, the antenna is a 0dBi PCB antenna. File: R86885 Page 5

EN 62311 ASSESSMENT METHODS EN 62311 allows for various assessment methods, including far field calculation, near field calculation, simulation, and numerical modeling. Assessments should be made in accordance with an existing basic standard. For the purposes of the assessment detailed in this test report the basic standard EN 50383 was used. The assessment is based on power levels and antenna gains detailed in this report and taken from the following test reports against the appropriate ETSI radio standard: Radio Standard(s) Issued By RE950331L08A EN 300 328 V1.7.1 ADT Corp. No. 47, 14 th Ling, Chia Pau Tsuen, Lin Kou Hsiang, Taipei Hsien, Taiwan, R.O.C. The assessment has only considered the intentional signals transmitted by the device. As all other emissions complied with the limits detailed in the appropriate radio standard and were significantly lower than the intentional signal it was not considered necessary to include these signals in the assessment. EN 50383 EVALUTATION METHODS The evaluation method first requires a determination of the antenna region(s) in which the exposure occurs, and from this determination the appropriate evaluation method (calculation or measurement) can then be used. ANTENNA REGION There are three regions defined in Annex A of EN 50383 Far field region, radiating near-field region and reactive near-field region. For each region there is a preferred (or reference ) evaluation method and possible alternatives. When an alternative method is used it typically provides a more conservative evaluation of the rf hazard. The region is determined, based on the minimum separation distance from the device antennas to persons and the size/gain of the antenna. The minimum separation distance is based on either a distance specified in the installation/user s manual or on an evaluation of intended use. File: R86885 Page 6

PREFERRED EVALUATION METHODS The preferred (reference) evaluation methods, and first and second alternatives, for each region are detailed in EN 50383 Table 1 and summarized below. FAR FIELD CALCULATION For calculating the field in the far-field region the free space formula below is used to determine the electric field or power flux density at a distance r from the transmitting antenna. 30PG E = r S = PG 2 4πr S = Power flux density W/m 2 E = Field Strength in V/m P = Power in Watts G = Gain of antenna (numeric gain) r = distance in meters RADIATING NEAR FIELD When human exposure is in the radiating near-field the reference method is a SAR evaluation, as detailed above. The first alternative to SAR measurements are E-field and H-field measurements. The second alternative is a calculation, and the possible calculation methods are either the synthetic model or cylindrical wave model. The synthetic model splits the antenna into n small sources and the field is calculated using: 2πrn 30. Pn Gn j( γ n + ) λ E = α n e r n E = Field Strength in V/m P n = Power in Watts radiated by element n G n = Gain of antenna element n r n = Distance in meters from element n The cylindrical wave model allows direct calculation of the power flux density, S, using: P 180 S = πdr δ S = Power flux density W/m 2 P = Power in watts radiated (W) D = Length of antenna (m) r = Distance in meters from the antenna The cylindrical wave model is valid for a range of distances where r c (the distance at which the Cylinder and far-field wave models give the same result) lies in the radiating File: R86885 Page 7

near-field, and where the distance is less than r c. At distances greater than r c the far field model (refer to the far-field calculation information in the previous section) is more appropriate. REACTIVE NEAR FIELD When human exposure is in the reactive near-field the reference method is a SAR evaluation. If the total radiated power is below limits detailed in section 7.1.2 of EN 50383 then the device is assumed to comply and measurements are not considered necessary. Further, whole-body SAR measurement methods are not currently specified and so localized SAR evaluations are used. Localized SAR evaluations are limited to operating frequencies between 0.8 and 3 GHz, antenna apertures less than 0.6m x 0.3m and investigation distances of less than 40cm. The alternative to SAR measurements are E-field and H-field measurements. LIMITS The limits are taken from the reference levels detailed in either Annex II or Annex III of Council Recommendation of 12 July 1999 on the limitation of exposure of the general public to electromagnetic fields (0 Hz to 300 GHz) (1999/519/EC). Annex III reference levels may only be used when the exposure is not highly localized. Compliance with the basic restrictions is ensured where the ratio of the measured/calculated value to the basic restriction / reference level is less than or equal to 1. MULTIPLE TRANSMITTERS When the evaluation has to account for simultaneous transmissions from co-located devices the individual transmitters are evaluated separately. The sum of the individual ratios of measured/calculated value to basic restriction / reference level has to be less than 1 for compliance to be demonstrated. File: R86885 Page 8

EVALUATION RESULTS SEPARATION DISTANCE The separation distance used in the assessment was 0.2m. LIMIT As the basis for compliance is being based on the far-field model, the reference level for equivalent plane wave power density is used as the basis for determining compliance. At the operating frequencies of the device, the limits are: Frequency Band Power Density (MHz) W/m 2 2400-2483.5 10 CALCULATIONS The table below contains the calculations to determine the reactive near-field, radiating near-field and far-field boundaries. It also shows the value for r c, the distance at which the far-field and cylindrical wave models produce the same value of power flux density. Frequency (MHz) 2462 Wavelength (m) 0.122 Antenna Gain (dbi) 0 Antenna Gain (numeric) 1.0 Antenna Aperture (m 2 ) 0.04 Antenna Length (m) 0.2 Evaluation distance (m) 360 Beamwidth (degrees) 19.35 Transmit Power (dbm) 2462 Far Field Boundary >0.03m Radiating Near Field 0.03m < r <= 0.03m Reactive Near-Field r <=0.03m r c 0.02 For operation in the 2400-2483.5 MHz band(s) the exposure is in the far field and so the far-field model has been used to determine the power density at the observation distance, 0.2m from the antenna. Frequency (MHz) 2462 Far-Field Estimation (W/m 2 0.17 ) Limit 10 Percentage of Limit 1.71% File: R86885 Page 9

RESULT SINGLE TRANSMITTER The estimated power density at a distance of 0.2m from the transmitting antenna is 0.17 W/m 2. This is 1.71% of the limit, therefore the device complies with the requirements of EN 503085, based on the evaluation methods of EN 50383 and the reference levels detailed in Council Recommendation of 12 July 1999. The calculations assumed the device may operate continuously. Although the interface protocol does not limit operating duty cycle, the actual operation would not typically be 100% and so the estimates are conservative. File: R86885 Page 10

MEASUREMENT UNCERTAINTIES ISO Guide 17025 requires that an estimate of the measurement uncertainties associated with the emissions test results be included in the report. The measurement uncertainties given below are based on a 95% confidence level (based on a coverage factor (k=2) and were calculated in accordance with NAMAS document NIS 81 and M3003. They have been taken from the radio test report on which the output power measurements used in the evaluation of the device were taken. Measurement Expanded Measurement Type Frequency Range Unit Uncertainty RF power, conducted dbm 25 to 7000 MHz ± 1.371dB Note Uncertainty value from ADT report, RE950331L08A File: R86885 Page 11

Appendix A Test Equipment Calibration Data The evaluation detailed in the test report was based on calculation. No test equipment was required. The test equipment and associated measurements uncertainties used to determine the output power measurements on which this evaluation was based can be found in ADT test report RE950331L08A, dated Apr 14, 2008. File: R86885 Page 12

Appendix B Test Configuration Photographs The evaluation detailed in the test report was based on calculation. As no measurements were made, test configuration photographs are not applicable. File: R86885 Page 13

End of Report This page is intentionally blank and marks the last page of this test report. File: R86885 Page 14