TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-D. D. C. SIGNAL POWERED FOR V, 4-20 & madc

Similar documents
TO BE DISCONTINUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-F

WORLD S SMALLEST BARGRAPH METER LOOP OR AC/DC POWERED > 30 INPUT SIGNAL CONDITIONERS

NEW MODEL SEB AUTOMATIC TRICOLOR SWITCHBOARD BARGRAPH FOR MIL-SPEC, NUCLEAR & HI-REL INDUSTRIAL USES WITH > 20 INPUT SIGNAL CONDITIONERS

AUTOMATIC TRI-COLOR ISOLATED TRIPLE BAR-DIGITAL CONTROLLER WITH USB/232/485/ETHERNET I/O & MICRO CARD FOR NUCLEAR, MIL-STD & INDUSTRIAL USE

NEW TECHNOLOGY METER Current Loop, Signal or External Powered

NEW. MODEL ACL Pat. Pend. WORLD'S FIRST POWERLESS TM A.C. LOOP TRANSMITTER, CONTROLLER FOR: VOLTS-AMPS-WATTS-HERTZ

BARGRAPH/CONTROLLER/REMOTE DISPLAYS Direct Replacements for Ametek (Dixson) BE051 & BE101Models >30 INPUT SIGNAL CONDITIONERS

1/8 DIN BAR-DIGITAL METER/CONTROLLER *AUTOMATIC TRICOLOR BAR *RELAYS/DAC/SERIAL *NUCLEAR *MIL-SPEC * INDUSTRIAL GRADES

SAFE SSAM-N CYBER SECURITY

AUTOMATIC, MANUAL OR DCS/PAC/SCADA NEW TECHNOLOGY 4-20mA TRANSMITTER FOR NUCLEAR-MILITARY-INDUSTRIAL USES

FC-33, DC SELECTABLE SIGNAL CONDITIONER

NEW TECHNOLOGY METER Current Loop, Signal or External Powered

INPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G

NEW TECHNOLOGY METER Current Loop, Signal or External Powered

SC SERIES 1 SQUARE! SIGNAL CONDITIONERS with 4-20mA, VDC OR SERIAL OUTPUT. SCT or SCX WITH CONNECTOR SCV P.C.B. MOUNT ONLY

DRG-SC Series Signal Conditioners

DP2000 ORDERING GUIDE To Order MODEL NO.

Specifications. 744 Users Manual

NEW TECHNOLOGY METER Current Loop, Signal or External Powered

ENGLISH. General features 2. Technical features 3. Installation 10. Preliminary operations 12. Front panel description 13.

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

NEW TECHNOLOGY METER Current Loop, Signal or External Powered

SDM3045X Digital Multimeter. DataSheet

NEW TECHNOLOGY METER Current Loop, Signal or External Powered

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Isolated, Linearized RTD Input 7B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

USB-2404-UI Specifications

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Calibration Techniques for the Home Lab

LAUREL ELECTRONICS, INC.

Economical Digital Indicators For Process and Electrical Measurement

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

RS Pro DIGITAL MULTI-METER SDM3055 SERIES

NEW TECHNOLOGY METER Current Loop, Signal or External Powered

Absolute Process Instruments

MODEL 9050 EXTENDED SPECIFICATIONS. 50ppm TRANSPORTABLE CALIBRATOR

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

Webinar Organizers. Ryan Shea. Don Miller. Joe Ryan. Support Specialist. Applications Specialist. Product Manager. Precision Digital Corporation

FC Series Signal Conditioners

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

PANEL MOUNT PROCESS METER IDP

Isolated Linearized 4-Wire RTD Input 5B35 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

UP1301A-( )( ) SERIES

Process Calibrator. TechChek 820

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions

WATT TRANSDUCER. Instruction Manual

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

Multifunction Calibrator - Model 8080

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

SDM3045X Digital Multimeter. DataSheet

Isolated, Linearized Thermocouple Input 5B47 FEATURES APPLICATIONS PRODUCT OVERVIEW

GE Fanuc IC695ALG600. Rx3i PacSystem

APPA 300 Series. The Most User-Friendly High Performance Multimeter

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

INSTALLATION & OPERATION MANUAL

PIE 525. Diagnostic Thermocouple RTD & Milliamp Calibrator Operating Instructions. Practical Instrument Electronics

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Analog Digital Multimeter with Insulation Resistance Measurement

PACSystems* RX3i IC695ALG600

The Aleph 5 is a stereo 60 watt audio power amplifier which operates in single-ended class A mode.

Introduction ISOLATED SIGNAL CONDITIONING can significantly increase

TRANSMILLE 3010A PRECISION MULTIPRODUCT CALIBRATOR EXTENDED SPECIFICATIONS

Model 6517B Electrometer / High Resistance Meter Specifications

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN

MODEL 9041 EXTENDED SPECIFICATIONS. 25ppm TRANSPORTABLE CALIBRATOR

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

PIECAL 820 Multifunction Process Calibrator

Isolated, Frequency Input 5B45 / 5B46 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ISOLATED 4-20 ma TRANSMITTERS

SIGNAL INTERFACE MODULE

Green LED (right of 'D' type connector)

Product Description. SIGnal Workbench. Programmable Signal Conditioning System

Uni-Mux XQL Multi-Channel Data Acquisition Module

PACSystems* RX3i IC695ALG600-DD

LM13600 Dual Operational Transconductance Amplifiers with Linearizing Diodes and Buffers

High Power Monolithic OPERATIONAL AMPLIFIER

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

Agilent U3400 Series 4½ and 5½ Digit Digital Multimeters

Arbiter Systems, Inc Vendels Circle, Suite 121 Paso Robles, CA USA

ELKOR MOC1 TRANSDUCER SET - MANUAL

Automated Thermocouple & RTD Calibrator

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i

SDM3055 Digital Multimeter. DataSheet

Practical Instrument Electronics PIECAL 820

This Errata Sheet contains corrections or changes made after the publication of this manual.

PIE 525B. Automated Thermocouple & RTD Calibrator Operating Instructions. Practical Instrument Electronics

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function

SPECIFICATIONS AND ORDERING INFORMATION MODELS: 100, 101, 102

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

MINI 048 / JUN 2003 PAGE 1. Temperature I/O Module HE500OCS048 / HE500OCS078 HE500RCS078

RISH MIT 30 Analog Digital Multimeter with Insulation Resistance Measurement

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SDM3055 Digital Multimeter. DataSheet

Figure 2 shows the actual schematic for the power supply and one channel.

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

Transcription:

TO BE DISCONTUED 12/2016. FOR REPLACEMENT MODEL, CLICK HERE: NTM-D NEW D. C. SIGNAL POWERED FOR V, 4-20 & madc (& EXTERNALLY POWERED FOR OTHER SIGNALS) 3 1/2" ANALOG METER REPLACEMENT *>20 Signal Conditioners *0.6" 3 1/2 Digit LED *Fits Standard 3 1/2 Barrel Meter *Same 2-Wire Connection *Zero & Span Adjustment FEATURES: *Replaces OTEK's "590" Series *Also Externally Powered for > 30 Inputs *Lifetime Warranted MODEL DCS 3 1/2 Digits DESCRIPTION: By popular demand we bring back the old "590" but with New Patented Technology so you can replace the old needle, fragile and inaccurate 19th Century Technology analog meters without changing your panel or wiring. Signal Powered: 4-20mA current loop and 4-30VDC, VAC, AAC, WAC & Hz-ideal for power line monitoring. Externally Powered: V & madc, V & ma RMS, TC, RTD, Frequency (40-20KHz), ph (0-14), %RH, and customs. The external power options cover the entire industrial range of 5-32 VDC and 90-265VAC. Zero and Span adjustments (12 Turn Pots) are conveniently located on the front. Signal Conditioners: 20+ signal conditioners are available (see description) for Powerless (Signal Powered) or externally powered applications. The DCS performs a self-test (C.O.P.) on power up for approximately 2 seconds. IF YOU DON'T SEE IT ASK FOR IT! SPECIFICATIONS @ 25 C : Signal Powered: *Accuracy & Linearity: + 0.05% of F.S. *4-20mA Loop Burden: <5VDC *VDC Current Burden: LED: < 15mA *Intensity: Brightest at 20mA, Dimmest at 4mA *Min.-Max. VDC Signal: 3-52VDC *Measuring Method: RMS Calibrated *Humidity: 5-95% RH, N.C. *CMBTF: >100,000 Hours *Connector: #10 Lug Externally Powered: *Loop Burden: 0.5V @ 20mA *VDC Signals: 10M Ohm Impedance *Power Consumption: 0.075W *A/D Technique: Sigma-Delta *CMRR: 100dB @ 50-60Hz *Hz V Range: 5-200VRMS, 50-20KHz *TC, RTD, ph & %RH Specs.: Same as Sensor *Op/Storage Temp.: 0-70 C/-20 + 80 C *Case: ABS, 94VO Black OTHER RELATED PRODUCTS: ACS: AC Signal Powered Meters, V, A, W, Hz, AC LPE: LED 4 1/2 Digit Loop Powered LPI: Loop Powered Isolator LPT: Loop Powered Wireless Transmitter LPX: Loop Powered Explosion Proof http://www.otekcorp.com SCE 1974

DCS continued HOW IT WORKS: Current Loop Powered: We use a Zener to clamp the voltage to 5V max. and monitor the Loop's current (we invented it in 1974). (Digit 2, Option 0). VDC Signal Powered: We monitor the voltage with high impedance and clamp it to a safe level to power the DCS. (Digit 2, Option 2). AC Signal Powered (Pat. #: 4,908,569): For VAC & Hz we use a capacitor limiting rectifier to power the DCS and monitor the VAC with an RMS-DC converter. For Hz we use an F-V for accurate conversion. For A.A.C. we invented (Pat. # 7,626,378) a C-V converter to extract the current from your C.T. for power and monitor the signal with RMS-DC. (Digit 2, Options Q-T). Externally Powered: Non-Isolated 5VDC or isolated 7-32VDC or 90-265VAC 50/60Hz is optional (Digit 3, Options 1-7). Max Power: 150mW. THE SIGNAL CONDITION- ERS: (2nd Digit) Option 0: 4-20mA Loop Powered: First introduced in 1975, the current flows through a Zener and "Shunt" resistor. The Zener clamps the voltage to about 3.5 Volts and the voltage across the Shunt is measured and displayed. Because an LED acts as a Zener, instead of a Zener the LEDs of the backlite are used to power the meter. If the "burden" (3.5-4.5V) is too high for your application, use the externally powered version. Option 1: 4-30VDC Signal Powered: Another OTEK innovation. The voltage signal powers an LDO to protect the DCS and a divider network is used to measure and display the signal. If the input resistance of this Option is too low (~ 500 Ohms), use option 9 and specify. Power Input must be Option 0 (Powerless). Accuracy: +0.1% of F.S. Option 2: 4-20mA Externally Powered: It only drops 0.1V @ 20mA (5 Ohms) but the "DCS" needs 5VDC @ 20mA to operate (including the backlight or LEDs). Power Input must be Option 0 (Powerless). Options 3-6: VDC & madc Externally Powered: Input impedance is 1 Mega Ohms on all VDC ranges and 100 Ohm on 2mA and 1 Ohm on 200 madc ranges. Options 7, 8 & A: V & ma RMS: Here we use a True RMS-DC Converter for accurate (+ 0.05%) measurement of sine waves up to 10KHz (+ 0.1% for 10-20KHz) and SCR;s fired to + 1%. Input impedances vs. range are the same as for VDC & madc ranges. Warning: No Isolation! Option 9: Custom: Use this option to describe any custom input, scale or modification to the DCS and contact us for feasibility and cost. -2- Option B: 5Amps AC: Specifically for current transformers (C.T.) this option requires an externally mounted (supplied) 0.05 Ohm, 0.1% 5 Watt resistor. You can mount the "Shunt" at your C.T. or next to the DCS but make sure the connections are "Perfect" to electrical codes. The C.T. might have "Lethal" High Voltage without a "Shunt" (Open) and the DCS will "Smoke". See OTEK's New ACS & CTT models for C.T. powered instruments (Patented.) Warning: No Isolation! Option E: RTD (PT100): We excite your 2 wire RTD with 200μA to avoid the "self heating" effect. The range of the DCS is the same as your RTD typically -200 0 C to +800 0 C (-328 + 1562 0 F). You can place the decimal point at will (typically -200.0 to 800.0 (-328.0 to 1562.0)). The PT100 has a temperature coefficient of 0.00385 Ohms/ Ohm/ 0 C. To change from PT100 to ANSI 392, or C to F, use simple commands via serial port. Accuracy: +0.5% of F/C plus sensor's error. Option F: RTD (PT1000): Same as PT100 except it is 1000 Ohms at 0 0 C instead of 100 Ohms @ 0 0 C. The same technique is used. For copper RTD (10 Ohm), contact OTEK. Same connection as Option E apply. Max Distance <30' (10M). Accuracy: +0.5% of F/C plus sensor's error. Note: For long distances use a 4-20mA transmitter such as our 900 or LPT series.

DCS continued Options G & H: Frequency Input: We use an F-V to accept frequencies from 40-20KHz and amplitudes from 1-400V peak or dry contact or open collector transistor (O.C.T.). For 50 or 60Hz power line frequency measurement. Use Option H or S. Option J: Thermocouple (Type J): This TC has a range of -210 to + 760 0 C (-350 + 1390 0 F). Its color is white (+) and Red (-), cold junction (CJ) is inside the DCS at the connector base. Make sure the connections from the DCS and your TC are as close to the DCS's entrance as possible to avoid errors. If you short out the DCS's +TC & -TC together, the DCS will read the ambient temperature due to its builtin C.J.C. (Cold Junction Compensation). Accuracy: + 2 0 F/C of signal input. Option K: TC (Type K): This is yellow (+) and red (-) and has a range of -270 + 1370 0 C (-440 + 2500 0 F). The same notes as Option J applies. Accuracy: + 2 0 F/C of signal input For Other TC use #9 and Specify Option L: %RH: This conditioner is designed to interface to a typical (capacitance type) 2-3pF/% of RH made by several manufacturers. Use Option 9 and contact OTEK to specify your sensor's specifications. Accuracy: + 2% RH of signal input. Option M: ph (Acidity): We use a FET input (10 15 ) amplifier and calibrate the DCS for 0-14.00 ph using the Industry's standard + 413 mv = + 7pH coefficient. Note: Not temperature compensated. Option N: ORP (Oxygen Reduction Potential): Our FET amplifier (10 9 ) accepts the industry standard 2000mV F.S. of the probe and the DCS displays it in % (0-100.00%). Note: Options Q-T only available with Powerless TM Signal power input (Option 0, Digit 3). (PAT. #: 4,908,569) Option Q: VAC Signal Powered: Warning! No Isolation! This option uses the AC Voltage Signal to power the LBD. Since the LBD uses about 30mA @ 5VDC, we use a coupling capacitor AC-DC converter to generate 5VDC and not to "Load" the signal with a transformer. Consequently, your signal source should be capable of producing about 150mW without overloading it, otherwise use Options 7 or 8 (externally powered). Range: 50-150VAC; Method: RMS Calibrated; Accuracy & Linearity: +0.5% of F.S. Best and safest when driven by a P.T. (Potential Transformer. Always turn power off before connecting! Option R: AAC Signal Powered: Warning! No Isolation! (Pat. #7,626,378) OTEK's Patented technique permits the extraction of power from a regular C.T. (Current Transformer) to power the DCS without distorting the signal. Since this option is designed to be powered from a C.T., it should not be connected directly to the mains without limiting the current and proper electrical grounding. Lethal Voltage might be present at the C.T. secondary (output) if the secondary is open. Always turn power off before connecting! Range (at C.T. output): 0.1-5AAC; Overload: 50%/30 seconds; Peak: 100%/1 second; Conversion: True RMS; Accuracy & Linearity: +0.05% of F.S.; Burden on C.T.: <150mW. Hz: 45-65. Option S: Hertz (Frequency) Signal Powered: Warning! No Isolation! This option uses the same power technique as Option Q above and the same precautions and warnings apply. Here we use a "Zero Crossing" detector and a F-V converter to give you the A.C. line frequency display with 0.1 Hz resolution. Range: VAC: 50-150VAC/ Frequency: 50-440 Hz; Accuracy & Linearity: +0.05% of F.S. Option T: Signal Powered AC Watts: Warning! No Isolation! Here we combine the powerless VAC & AAC options to arrive at real power calculations through our CPU and DAC. The same warnings and precautions of Options Q & R apply. Range: VAC: 50-150; AAC: 0.1-5A; Frequency: 40-450Hz; Accuracy & Linearity: +0.1% of F.S.; Conversion: True RMS. Hz: 45-65. Contact OTEK for other functions. Power/Input (Digit 3): Option 0: Powerless : The DCS is powered from the signal that it measures. ONLY available for options 0, 2, and Q through T of input signal (Digit 2). WARNG: Options Q-T (Digits 2 & 3) could have lethal potentials! -3-

All listed I/O options (except Powerless ) are available. Power requirements vary with options included. The DCS requires under 150 mw (30 ma@5vdc). These options offer minimum isolation of 500 VAC or DC and their efficiency is about 80%. All input ranges are +/-5%. Decimal Points (Digit 4): The DCS has internal D.P. selection, specify or open unit and change jumpers on display board. DCS MECHANICALS 3.26 FRONT VIEW 0.75 1.75 OTEK F.S. ADJ. 3.26 SERT 0.45 0.63 1.55 0.062R SIDE VIEW C 2.24 L 0.55 0.35 1.84 0.40 4-M3 Ø2.71 1.12 REAR VIEW 1.12 1 2 OTEK TUCSON,AZ Ø2.80 3 4 VENT HOLES Ø0.15 2.24 POST 1/4-28 BRASS (4) TYPICAL CONNECTIONS 1: +/Hi Signal Input 2: -/Lo Signal Input 3: +/Hi Power Input 4: -/Lo Power Input NOTE: Use 1 & 2 for signal/loop powered models Use 3 & 4 for powered models DCS SERIES continued Options 3-7: Isolated Power (7-32VDC & 90- Option 1 &2: Non-Isolated 5 or 7-32 VDC Power: 265VAC): -4- http://www.otekcorp.com SCE 1974

DCS ORDERG FORMATION 9/9/14 NOTE: Please READ BEFORE building part number: 1. If digit 2 is option 0, 1, Q, R, S or T, then digit 3 must be option 0. 2. See notes at bottom of page. Model: DCS - 1 2 3 4 DISPLAY & BACKLITE (3) 0...3 1/2 Digit LED 9...Custom (Contact OTEK) F.S. PUT SIGNAL/Z in (1,4,5,7) 0...4-20mA Loop Powered 1...4-30VDC Signal Powered 2...4-20mA External Powered 3...200mVDC/1M Ohms 4...500 VDC/1M Ohms 5... 2mADC/100 Ohms 6... 200mADC/1 Ohms 7...200mVRMS/1M Ohms 8...500VRMS/1M Ohms 9...Custom (Contact OTEK) A... 2mARMS/100 Ohms B...5ARMS/0.05 Ohms E...2 Wire RTD PT100 (100 Ohms) F...2 Wire RTD PT1000 (1K Ohms) G...Frequency 40-20 KHz H...Frequency 50-440Hz Line J...TC Type J K...TC Type K L...%RH (Specify Sensor) M...pH (0-14.00) N...ORP (0-2000 mv) Q...VAC Signal Powered (P.T.) R...AAC Signal Powered (5A C.T.) S...50-440 Hertz Signal Powered (P.T.) T... Watts AC Signal Powered (P.T. & C.T.) DEC. POT / RANGE / CALIBRATION (5) 0...Standard with NO DEC. POT 1...1.XXXX & Std 2...1X.XXX & Std 3...1XX.XX & Std 4...1XXX.X & Std 9...Custom (Contact OTEK) POWER PUT (1) 0...Signal/Loop Powered 1... Non-Isolated 5VDC 2...Non-Isolated 7-32VDC 3... Isolated 5VDC 7...Isolated 90-265VAC 8...Isolated 7-32VDC 9...Custom (Contact OTEK) DOWNLOADS: For manuals, user-software or drivers: www.otekcorp.com NOTES: 3. Option 2 on digit 1 only requires 1mA. 4. See data sheet. Use #9 and specify for input not listed. 5. Specify calibration if other than standard 0-F.S. (1999 or 19999). Decimal point is internally selectable. 6. Specify sensor manufacturer and type for ph & % RH. 7. Zero adjustment is internal. -5- http://www.otekcorp.com SCE 1974