RF Wireless Version On/off Control

Similar documents
FSTR Series Sensor with RF Wireless Transmission Control Model: HC428V/RF, HC418V/RF, & HC424RF

Fixture Built-in Sensor Daylight Harvest Version

Applications. HBT02 Transceiver Node. Features. Note: This datasheet is intended for information related to the hardware only.

Product Specification

Human Centric Lighting System

Philips Ledalite Phone: Fax: Web: Programming Guide Version 2.0

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.

Installation hole (4.2mm) Push. Ambient daylight threshold. 8 hours manual on

Product Specifications

Technical Application Guide

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

with Light Level, Isolated Relay and Manual On features

EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

PRODUCT DATASHEET Alphard Bulkhead Microwave Sensor

Radio motion detector comfort 1.1 m/2.2 m quicklink Order number

Data sheet. Function description. Benefits

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

This document is intended for Lighting Control Systems professionals

LEDCF LOW-PROFILE LED CANOPY LUMINAIRE

LOAD AWG Solid CU Wire Only LINE NEUT FSP-211. High/Low PIR Occupancy Sensor 230 VAC, 50 Hz 1200W max ballast 5E4

EBDHS-MB-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

Single-zone Daylighting Control Sequences of Operation. Topic: DLM Operation with LMLS-400 Photosensor, v2.xx Issue: # TB185 Date: March 10, 2012

Sense Command Control. Third Eye. Energy Saving Sensors Save Energy Today for a Better Tomorrow

High/Low Bay Passive Infrared Occupancy Sensor

EBDSM-PRM Product Guide

EBDHS-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

RF ceiling microwave presence detector DALI / DSI

Dialight Daylight Harvesting Sensor User Guide

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

Motion Sensors. Product Features. Applications

Operating instructions II / 2004

User Manual 3X300 DIMMER MODULE DM03B02KNX

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

KNX ENO 620/622 (32-channel AP)

INSTALLATION & OPERATION MANUAL

focushand 2 Users Manual FocusHAND System description

Light Control guide for Soundlight Comfort Ceiling OccuSwitch DALI Control Guide

Motion Sensors. Product Features. Applications

Switch actuator. Movement detector Move/monitoring 1305/1.0, Art. No , ,

RPT LEDCF 4000K LEDCF LOW-PROFILE LED CANOPY LUMINAIRE PART NUMBER BUILDER

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR

KNX manual 1-channel flush-mounted switch actuator SU 1

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

v3 360 Passive Infrared Line Voltage Occupancy Sensor

Wireless Copilot. Safe2Fly - Height Only Version. Page NanoQuip Ltd

Dual Technology Wall Mount Occupancy Sensor

Wireless Ceiling Mount Sensor

ActiLume 1-10V. OEM application guide

Installing the FSP-211 Sensor in Light Fixture

OCCUPANCY SENSOR REMOTE USER GUIDE

ZoneLite setup remote handset. Daylight Linking & Daylight Dependency control

TABLE OF CONTENT A. Installation and Mounting Installation 3 2. Mounting Receiver Addressing... 5 B. Key Interface. 7 C.

Technical Application Guide for UP-SHINE LED Linear

Technical Guide for Radio-Controlled Advanced Wireless Lighting

OCC Motion Sensor. Guide: how to program and use

Technical Application Guide for UP SHINE LED T8 Batten UP-AL06-9W-BO-M

ST500 Indoor LED Activator Starterkit Preliminary Datasheet. Features. Applications. Description. Electrical Connection

Dual Technology Wall Mount Occupancy Sensor

EIB/KNX Switch Actuators. User manual

3000W multi Pir light controller

STX Stair lighting controller.

LCC1653, LCC1656, LRI1653 Datasheet ActiLume DALI System


MANUFACTURER MODEL NUMBER LUMENS COLOR TEMPERATURE OPTIONS 3100LM 4500LM 5800LM

High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires

Wireless Ceiling Motion Sensor for Occupancy / Vacancy Detection with integrated diagnostic tools INSTALLATION GUIDE

Short operating instructions

EasyAir Office sensor advanced grouping SNS200

LLC1681, LRI1655 Datasheet ActiLume Wireless 1-10V system

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

LED pool light Intelligent Remote Controller OWNER S MANUAL PLP-REM-300

Experiencing trouble with your zboost setup? Installation Tips. Please note the following important factors in determining zboost performance:

Wireless Network Manager (NM) and Wireless Transceiver (TRV)

Unidirectional Gateway EnOcean - KNX/BUS

Light Management Systems for Indoor Use MULTISENSORS

Astra-R Kit Wireless Alarm System Operation Manual

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx

Wireless multizone receiver RDE-MZ6

SELECTABLE MODE HIGH/LOW/OFF PIR FIXTURE INTEGRATED INDOOR/OUTDOOR MOTION/PHOTO SENSOR

Product and Applications Description


INSTALLATION AND OPERATING MANUAL

SeeTool - Solutions for KNX

EasyAir office sensor standalone SNS100

3000W MULTI PIR LIGHT CONTROLLER

QAM Snare Isolator User Manual

Wireless 900 MHz Receiver

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB

Wireless Control Systems

WIRELESS DIMMER FOR HEATING

EasyAir Office sensor advanced grouping SNS200

Wireless Ceiling Mount Sensor for Occupancy / Vacancy Detection INSTALLATION GUIDE

SAPLING WIRELESS SYSTEM

USB RX Speed. Instructions for use Betriebsanleitung Mode d emploi Instrucciones para el uso Istruzioni per l uso

Radio Link Starter Kit

PWM LED strip dimmer module for the Velbus system

Transcription:

RF Wireless Version On/off Control HC08V/RF + HC0RF Loop in 8 hours Detection Pattern 0 /88 / 5 /95 MHz Ambient daylight threshold Loop out manual on Condominium control 5s~0min ~50Lux Rotary coding switch(tx) Stand-by period Rotary coding switch(rx) RF antenna Antenna module RF antenna Stand-by dimming level Brightness on RF signal LED indication -0V Push Rotary coding switch HC08V/RF HC0RF RF Transmitter RF Receiver Hytronik Microwave motion sensor 50

This is a combination of motion sensor and RF wireless transmission. The motion detected by the unit HC08V/RF can pass onto other pre-defined individuals (the units) though RF transmission. Thanks to fixed address coding technology, it is easy to set up transmission groups. Up to different groups can be created by using the rotary coding switch. The transmission can reach 0 meters indoor and 00 meters in the open area. Digital receiving and transmitting method, high anti-interference capability. Optional transmission frequency of /88/5/95 MHz, thanks to FSK technology. RF Grouping (max. channels) Thanks to fixed address coding system, the setup of communication channel and the definition of s and s can be easily achieved by the rotary coding switch -- ( the transmitter unit is called, and the receiving unit called ). Using a screwdriver to adjust the rotary switch on both the & unit, to keep them pointing at the same channel, the grouping is then automatically completed. channels (max. groups) available for both the & unit. Using a screwdriver to point the arrow to the same position on the unit and units. Function and Options RF Transmitter (HC08V/RF) + RF Receiver (HC0RF), on-off function This is a combination of motion sensor and RF radio wireless transmission, which is the perfect solution for retrofit or carpark projects, easy installation and free of wiring. With fixed address coding system, by rotary coding switch method, selected and directional communication can be easily setup. Once there is motion detected, the can trigger unlimited number of s as long as they are within the transmission range. The unit can respond to unlimited numbers of s respectively. With sufficient nature light, the sensor is not triggered by motion. With insufficient nature light, the sensor is triggered by motion, the switches on all salves (unlimited) by RF signal. After the hold time, sensor switches off the whole group of lamps automatically if no movement is detected. Even in case, the (HC0RF) fails to receive the off signal from the, it will also switch off automatically after a 0sec time delay. 5 Hytronik Microwave motion sensor

Typical application for the staircase and corridor: HC0RF () HC08V/RF HC0RF () HC08V/RF While the st sensor detects motion on the st floor, it switches on and sends signal to all units. All HC0RF on the st floor turn on and the HC08V/RF on the nd floor goes to stand-by brightness. The person walks to the nd floor, the nd HC08V/RF switches on. All HC0RF on the nd floor turn on and the HC08V/RF on the rd floor goes to stand-by brightness. HC0RF () HC08V/RF HC0RF () HC08V/RF The person walks to the rd floor, the rd HC08V/RF switches on. All HC0RF on the rd floor turn on and the HC08V/RF on the th floor goes to stand-by brightness. Meanwhile, the sensors on the st floor dim to stand-by brightness or go off after hold time. The person walks to the th floor, the th HC08V/RF switches on. All HC0RF on the th floor turn on and the next HC08V/RF goes to stand-by brightness... Meanwhile, the HC08V/RF on the st floor goes off after stand-by period, and the sensors on the nd floor dim to stand-by brightness after hold time. 8H manual on mode for LED lamp With simple operation, rapidly turn off/on the fixture cycles within sec. (the green LED on the sensor flashes and the fixture blinks times to indicate the success of setup), lamp will be on for 8 hours, and then automatically goes to sensor mode after 8 hours. Useful when sensor function is not needed in special occasion. This 8H manual on feature can be cancelled by turn off/on the fixture cycle within sec. Ambient daylight threshold With simple operation, rapidly turn off/on the fixture cycles within sec:. The green LED on the sensor flashes slowly for 5 seconds, meanwhile the fixture blinks twice.. The daylight sensor measures and remembers the surrounding lux for sec.. The fixture and green LED is on for 0s to indicate the success of learning. * This feature enables the fixture to function well in any real application circumstance, where the daylight penetrated into fixture may vary a lot. * The latest surrounding lux value overwrites previous lux value learned. * Both the settings on DIP switch and the learned ambient lux threshold can overwrite each other.the latest action stays in validity. Hytronik Microwave motion sensor 5

0 Zero-cross relay operation Designed in the software, the sensor switches on/off the load right on the zero-cross point, to ensure the min. current passing through the relay contact point, and enable the maxi. load and life-time of the relay. 5 Loop-in and loop-out Double L N terminal makes it easy for wire loop-in and loop out, saves the cost of terminal block and assembly time. RF Manual Grouping override (max. ( for HC08V/RF channels) only ) This sensor reserves the access of manual override function for end-users to switch on/off, or adjust the stand-by dimming level with the push-switch, which makes the product more user-friendly, and more options to fit for some extra-ordinary demands. * Short push (<s): on/off; ON OFF: the light turns off immediately and can not be lighten for a certain time (equals to hold time preset) even movement is detected. After this period, the sensor goes to auto sensor mode. OFF ON: the light turns on and goes to sensor mode, even when ambient LUX level exceeds the daylight threshold. * Long push (>s): dim up/down the stand-by dimming level between and. Both the settings on DIP switch and manual override can overwrite each other, the latest action stays in validity. *If customers do not want to have this manual override function, we can just leave this push terminal alone, not connected to any wire. Note:. Motion sensor overwrites daylight sensor, meanning the daylight sensor starts to check the ambient natural light only when the lamp is switched off (motion hold-time elapsed).. -0V output on the unit HC08V /RF is isolated, SELV output. Wiring Diagram ))))))))))))))))) RF Signal Detection Pattern 0 9 ceiling mounting height(m) 0% 75% wall mounting height 0% 75% ceiling mounting pattern (m) wall mounting pattern (m) 5 Hytronik Microwave motion sensor

Settings (HC08V/RF) can be reduced by selecting the combination on the DIP switches to fit precisely for each specific application. I maximum range up to II 75% III IV means the time period you would like to keep the lamp on after the person has left the detection area. 5s 0s I 5s II 0s III minute IV 5 minutes V 0 minutes VI 0 minutes VII 0 minutes Stand-by period (corridor function) This is the time period you would like to keep at the low light output level before it is completely switched off in the long absence of people. Note: 0s means on/off control; + means steps dimming control, fixture never switches off. 8 0s 0s min 5min 0min 0min H + I 0s II 0s III minute IV 5 minutes V 0 minutes VI 0 minutes VII H VIII + Stand-by dimming level This is the dimmed low light output level you would like to have after the hold-time in the absence of people. Note: the stand-by period and stand-by dimming level set up on the is only valid for the unit (HC08V/RF). 0% 0% I II 0% III 0% IV 5 The daylight threshold can be set on DIP switches, to fit for particular application. Disable 50Lux 0Lux Lux I Disable II 50Lux III 0Lux IV Lux Technical Data Operating voltage Switched power Coding Hold time Stand-by period Daylight threshold RF. Communicatin Chanels Microwave frequency Microwave power Detection range Detection angle RF. Transmission distance Mounting height Operating temperature RF frequency Certificate 0-0VAC 00W Fixed address coding (rotary coding switch for grouping) 0/50/75/, can be customized 5s/0s/min/5min/0min/0min/0min, can be customized 0s/0s/min/5min/0min/0min/hour / + ~50 lux, disable, can be customized channels for grouping 5.8GHz+/-75MHz <0.mW Max. (DxH ): m x m 0~50 O 0 meters indoor, 00 meters in open area Max. m. -5 o C ~ +70 o C /88 /5 / 95 MHz (FSK mode) Semko, EMC, CE, R&TTE, SAA Hytronik Microwave motion sensor 5