Reference wavelets used for deconvolution of ultrasonic time-of-flight diffraction (ToFD) signals

Similar documents
ENHANCEMENT OF SYNTHETIC APERTURE FOCUSING TECHNIQUE (SAFT) BY ADVANCED SIGNAL PROCESSING

The Quantitative Study of TOFD influenced by the Frequency Window of Autoregressive Spectral Extrapolation

The Application of TOFD Technique on the Large Pressure Vessel

Improving Time Estimation by Blind Deconvolution: with Applications to TOFD and Backscatter Sizing

Generation Laser Scanning Method for Visualizing Ultrasonic Waves Propagating on a 3-D Object

Performance of UT Creeping Waves in Crack Sizing

Ultrasonic Imaging of Tight Crack Surfaces by Backscattered Transverse Wave with a Focused Transducer

Kirchhoff migration of ultrasonic images

Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection

Keywords: Ultrasonic Testing (UT), Air-coupled, Contact-free, Bond, Weld, Composites

Reduction of Dispersive Wave Modes in Guided Wave Testing using Split-Spectrum Processing

Spectrum Analyses and Extracting Components of Ultrasonic Echo Signals Qiu-ze YE, Xi-zhong SHEN and Wei-wei CAO

ECHO-CANCELLATION IN A SINGLE-TRANSDUCER ULTRASONIC IMAGING SYSTEM

NDI Techniques Supporting Steel Pipe Products

Ultrasonic pulse propagation in a bonded three-layered structure

Ultrasonic Testing using a unipolar pulse

SPARSE ARRAY TOMOGRAPHY SYSTEM FOR CORROSION EXTENT MONITORING H. Bian, H. Gao, J. Rose Pennsylvania State University, University Park, PA, USA

1831. Fractional derivative method to reduce noise and improve SNR for lamb wave signals

Guided Wave Travel Time Tomography for Bends

CONTACT LASER ULTRASONIC EVALUATION OF CONSTRUCTION MATERIALS

ULTRASONIC GUIDED WAVE FOCUSING BEYOND WELDS IN A PIPELINE

The Development of Laser Ultrasonic Visualization Equipment and its Application in Nondestructive Inspection

NUMERICAL MODELING OF AIR-COUPLED ULTRASOUND WITH EFIT. D. E. Chimenti Center of Nondestructive Evaluation Iowa State University Ames, Iowa, USA

Ultrasonic Guided Wave Testing of Cylindrical Bars

Nondestructive Testing and Flaw Detection in Steel block Using extension of Split Spectrum Processing based on Chebyshev IIR filter

Introduction To NDT. BY: Omid HEIDARY

Spectral Distance Amplitude Control for Ultrasonic Inspection of Composite Components

Available online at ScienceDirect. Physics Procedia 70 (2015 )

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE

Imaging using Ultrasound - I

Assessment of lamination defect near the inner surface based on quasi-symmetric circumferential Lamb waves

NDT-PRO Services expands service offering

A Novel Crack Location Method Based on the Reflection Coefficients of Guided Waves

DETECTION OF CORROSION IN BOTTOM PLATES OF GAS AND OIL TANKS USING GUIDED ULTRASONIC WAVES AND ELECTROMAGNETIC ULTRASONIC (EMAT) TRANSDUCERS

NONDESTRUCTIVE EVALUATION OF CLOSED CRACKS USING AN ULTRASONIC TRANSIT TIMING METHOD J. Takatsubo 1, H. Tsuda 1, B. Wang 1

Determination of the Structural Integrity of a Wind Turbine Blade Using Ultrasonic Pulse Echo Reflectometry

BASICS ULTRASONIC TESTING METHOD. -Dr.Oruganti Prabhakar Proprietor-OP-TECH

Use of Lamb Waves High Modes in Weld Testing

Sonic Distance Sensors

An Overview Algorithm to Minimise Side Lobes for 2D Circular Phased Array

Research on An Inspection Method for De-bond Defects in Aluminum. Skin-Honeycomb Core Sandwich Structure with Guided Waves

An Investigation into the Performance of Complex Plane Spilt Spectrum Processing Ultrasonics on Composite Materials

TOFD-Scan Imaging Based on Synthetic Aperture Focusing. Technique

Finite element simulation of photoacoustic fiber optic sensors for surface rust detection on a steel rod

Application of Ultrasonic Guided Waves for Characterization of Defects in Pipeline of Nuclear Power Plants. Younho Cho

Table 1 The wheel-set security system of China high-speed railway

Analysis of Crack Detection in Metallic and Non-metallic Surfaces Using FDTD Method

Optimization of Ultrasound Broadband Transducers for Complex Testing Problems by Means of Transient and Time Harmonic Sound Fields

Change in Time-of-Flight of Longitudinal (axisymmetric) wave modes due to Lamination in Steel pipes

USE OF A PRIORI INFORMATION FOR THE DECONVOLUTION OF ULTRASONIC

Developments in Ultrasonic Phased Array Inspection III

EFFECT OF SURFACE COATINGS ON GENERATION OF LASER BASED ULTRASOUND

FATIGUE CRACK DETECTION IN METALLIC MEMBERS USING SPECTRAL

REFLECTION AND TRANSMISSION OF LAMB WAVES AT DISCONTINUITY IN PLATE Z. Liu NDT Systems & Services AG, Stutensee, Germany

ULTRASONIC DEFECT DETECTION IN BILLET USING TIME- OF-FLIGHT OF BOTTOM ECHO

CRACK DETECTION AND DEFECT CLASSIFICATION USING THE LLT - TECHNIQUE. Wolfgang Gebhardt and Friedhelm Walte

Basic functions of the universal flaw detector GEKKO

RADIATION OF SURFACE WAVES INTO CONCRETE BY MEANS OF A WEDGE TRANSDUCER: DESIGN AND OPTIMIZATION

Understanding How Frequency, Beam Patterns of Transducers, and Reflection Characteristics of Targets Affect the Performance of Ultrasonic Sensors

Effect of coupling conditions on ultrasonic echo parameters

Simulation of Ultrasonic Testing of Rail Wheel Face using Phased Array and DDF technique

GUIDELINES FOR THE APPLICATION OF TIME-OF-FLIGHT DIFFRACTION (TOFD) AND PHASED ARRAY ULTRASONIC TESTING (PAUT) TECHNIQUES

Tadeusz Stepinski and Bengt Vagnhammar, Uppsala University, Signals and Systems, Box 528, SE Uppsala, Sweden

INVESTIGATION OF IMPACT DAMAGE OF CARBON FIBER- RAINFORCED PLASTIC (CFRP) BY EDDY CURRENT NON- DESTRUCTIVE TESTING

A NEW APPROACH FOR THE ANALYSIS OF IMPACT-ECHO DATA

GUIDED WAVES FOR DAMAGE MONITORING IN PLATES FOR NOTCH DEFECTS

A Breakthrough in Sputtering Target Inspections: Ultra-High Speed Phased Array Scanning with Volume Focusing

Maximizing the Fatigue Crack Response in Surface Eddy Current Inspections of Aircraft Structures

DAMAGE DETECTION IN PLATE STRUCTURES USING SPARSE ULTRASONIC TRANSDUCER ARRAYS AND ACOUSTIC WAVEFIELD IMAGING

ACCURACY IMPROVEMENT ON NON-INVASIVE ULTRASONIC-DOPPLER FLOW MEASUREMENT BY UTILZING SHEAR WAVES IN METAL PIPE

Measurement of phase velocity dispersion curves and group velocities in a plate using leaky Lamb waves

HIGH TEMPERATURE THICKNESS MONITORING USING ULTRASONIC WAVES

Long Range Ultrasonic Testing - Case Studies

MIRA Purpose MIRA Tomographer MIRA MIRA Principle MIRA MIRA shear waves MIRA

Development of Automatic Neural Network Classifier of Defects Detected by Ultrasonic Means

Modern Electromagnetic Equipment for Nondestructive Testing

Non-Destructive Method Based on Rayleigh-Like Waves to Detect Corrosion Thinning on Non- Accessible Areas

IMPROVING THE MATERIAL ULTRASONIC CHARACTERIZATION AND THE SIGNAL NOISE RATIO BY THE WAVELET PACKET

LASER GENERATION AND DETECTION OF SURFACE ACOUSTIC WAVES

Sonotron NDT 4, Pekeris str., Rabin Science Park, Rehovot, 76702, Israel Phone:++972-(0) Fax:++972-(0)

High contrast air-coupled acoustic imaging with zero group velocity Lamb modes

2010 ULTRASONIC BENCHMARKS

Ultrasonic Guided Waves for NDT and SHM

NARROWBAND ULTRASONIC SPECTROSCOPY FOR NDE OF LAYERED STRUCTURES T. Stepinski and M. Jonsson 1 Uppsala University, Uppsala, Sweden

RELIABILITY OF GUIDED WAVE ULTRASONIC TESTING. Dr. Mark EVANS and Dr. Thomas VOGT Guided Ultrasonics Ltd. Nottingham, UK

A SHEAR WAVE TRANSDUCER ARRAY FOR REAL-TIME IMAGING. R.L. Baer and G.S. Kino. Edward L. Ginzton Laboratory Stanford University Stanford, CA 94305

Corrosion Assessment of Offshore Oil Pipeline Based on Ultrasonic. Technique

Detection, identification and sizing of plane defects with time-of- flight diffraction technique (TOFD) application in manual flaw detectors.

Detection of Protective Coating Disbonds in Pipe Using Circumferential Guided Waves

DACON INSPECTION SERVICES. Phased Array Ultrasonic Testing

2. Pulsed Acoustic Microscopy and Picosecond Ultrasonics

ULTRASONIC FIELD RECONSTRUCTION FROM OPTICAL INTERFEROMETRIC

ULTRASONIC MEASUREMENT SYSTEM FOR THE ASSESSMENT OF

Observational Astronomy

ISO INTERNATIONAL STANDARD. Non-destructive testing Acoustic emission inspection Secondary calibration of acoustic emission sensors

Determination of the width of an axisymmetric deposit on a metallic pipe by means of Lamb type guided modes

CRACK SIZING USING A NEURAL NETWORK CLASSIFIER TRAINED WITH DATA OBTAINED FROM FINI1E ELEMENT MODELS

Professor Emeritus, University of Tokyo, Tokyo, Japan Phone: ;

AN AUTOMATED ALGORITHM FOR SIMULTANEOUSLY DETERMINING ULTRASONIC VELOCITY AND ATTENUATION

Advanced Ultrasonic Imaging for Automotive Spot Weld Quality Testing

Transcription:

17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Reference wavelets used for deconvolution of ultrasonic time-of-flight diffraction (ToFD) signals Farhang HONARVAR 1, Amin YAGHOOTIAN 2 K. N. Toosi University of Technology, Pardis St., Mollasadra Ave., Vanak Sq., Tehran 1999143344, Iran. 1 Phone: (+98) 21 88674841, Fax: (+98) 21 88674748; e-mail: honarvar@kntu.ac.ir 2 Phone: (+98) 916 305 7163, Fax: (+98) 21 88674748; e-mail: yaghootian@alborz.kntu.ac.ir Abstract One major disadvantage of ultrasonic time-of-flight diffraction (ToFD) technique is the weakness of echoes which are diffracted from crack tips. This shortcoming, to some extent, can be overcome by application of proper signal processing techniques. Deconvolution techniques have shown to be quite effective for this purpose. A deconvolution process needs to use a reference wavelet in order to extract the required information from the signal. Accordingly, one of the major challenges in using deconvolution techniques is the choice of the reference wavelet. This paper discusses some of the problems encountered in the selection of the reference wavelet and proposes methods to overcome these problems. The angle-dependent deconvolution technique is one of these methods in which the reference wavelet used for processing each part of the signal is different from wavelets used for other parts. The principles of this method are described and its effectiveness is demonstrated by both simulation and experiment. Keywords: ultrasonic testing, time-of-flight diffraction (ToFD) technique, deconvolution, wavelet Introduction Ultrasonic testing (NDT) is an effective nondestructive method for evaluating the quality of materials and manufactured components. In an ultrasonic test, the signal received by the transducer contains considerable information about the specimen properties including the location and/or size of cracks and defects. Either amplitude or time-of-flight of the pulse is used for evaluating the crack size and/or location. Since the amplitude of the received signal could be affected by many parameters such as roughness, transparency, and orientation of a defect, it is more appropriate to use the time-of-flight diffraction (ToFD) technique to ensure higher accuracy in measurements. The basic principle of ToFD is illustrated in figure (1). When an ultrasonic wave is incident on a cracklike defect, besides specular reflection of the wave from the crack, part of the wave is also diffracted at the tips of the crack. The diffracted energy spreads over a wide angle and can be picked up from almost anywhere along the surface of the specimen. ToFD is a very powerful ultrasonic technique which could be used for both detection and sizing of defects. Accurate sizing is accomplished by determining the location of the tips of the flaw by measurement of time-of-arrival of echoes bouncing off the flaw tips [1]. Since the emitted wave from an ultrasonic transducer diverges with respect to the central axis of the probe, in many ToFD tests, the whole thickness of the specimen can be inspected in one single shot. A crack tip diffracted echo can be easily identified as it lies between the lateral and backwall echoes. Although crack tip diffracted echoes are useful for detection of flaws, the captured signals are sometimes hard to interpret due to the impulse response of the measurement system and electronic noise [2]. Moreover, overlapping echoes from closely spaced reflectors may further complicate the interpretation of results. One major disadvantage of time-of-flight diffraction (ToFD) technique is the relative weakness of the crack tip diffracted echoes. This shortcoming, to some extent, can be improved by application of proper signal processing techniques. Deconvolution techniques have shown to be quite effective for

this purpose. To apply a deconvolution process to an ultrasonic signal, first a wavelet must be chosen as the reference signal. Since for a ToFD signal, the frequency spectrum of each echo can be different from other echoes, so it is very important to choose the proper wavelet for deconvolving the signal. This paper discussed the problems encountered in the selection of the reference wavelet and proposes methods for overcoming these problems. Angle dependent deconvolution is introduced as good approach for avoiding the aforementioned problems. The principles of this method are described and its effectiveness is demonstrated by applying it to both simulated and experimental ultrasonic signals. Lateral Wave Tip Diffraction Back wall Reflection + + - - Lateral Wave Upper Tip Lower Tip Back wall Figure 1- A typical ToFD set-up and the corresponding ToFD signal Signal processing In ultrasonic testing, the impulse response of the test specimen can be assumed to be a discrete sum of delta functions [3], (1) where designates the amplitude of each echo. In practice, this impulse response is convolved with the impulse response of the measurement system, which incorporates the effects of the transducer(s), ultrasonic instrument, coupling fluid, cables, and travel paths in the test material. Therefore, a measured ultrasonic signal, can be modeled as the convolution of the measurement system impulse response,, with the test specimen impulse response,, plus noise,, that is, where is the linear convolution operator. Extraction of from the measured signal,, improves the appearance and the time resolution of the signal by elimination of the adverse effects of the measurement system and noise. Several signal processing methods such as split-spectrum processing [4], Wigner-Ville Transformation [5], deconvolution methods [6], noise reduction by wavelets [7] etc. have already been examined for the enhancement of ultrasonic testing signals. It has also been shown that the application of Wiener filtering followed by autoregressive spectral extrapolation can significantly improves the time resolution and signal-to-noise ratio of ultrasonic testing signals [6]. While the original technique is relatively prone to selection of processing parameters, a modified version of this method has shown to be quite robust and well suited for real applications [3]. The common practice in applying the Wiener filter to ultrasonic testing signals is to use one of the echoes of the received signal, for example the backwall echo, as the reference wavelet. Choosing the proper reference signal is very important in the deconvolution process. In all previous studies which (2) 2

use this method, a certain reference wavelet is chosen for processing the ultrasonic testing signal. This could be the backwall echo or echo obtained from a known reflector. In ToFD technique, the probe has a wide beam spread and flaw echoes can be received from different parts of the beam. Since echoes arriving from different parts of the beam have different frequency spectra, use of one single reference signal for deconvolution is not suitable any more [8, 9]. Wave field of a circular flat transducer Before considering the frequency spectra of the signals that could be obtained in ToFD tests, it is necessary to discuss the pressure field of a vibrating piston source. Tang [10] studied the radiation emitted by a circular flat transducer into an elastic half space to show the dependence of the frequency spectrum of each point of the wave field relative to its position. He used the Johnson s Green Function for numerical calculation of the integral for an arbitrary point in the far field of a solid medium. Transducer with radius a x 1, x ϕ θ R x 3, z r x 2, y Figure 2- Representation of a circular transducer Figure (2) shows an example of the configuration and coordinate system used in these calculations. In a circular transducer, the ultrasonic beam is radiated symmetrically, therefore the dependency on can be neglected and the wave field can be assumed to be a function of excited transducer, the radial displacement is expressed as [9], u R 2 a σ zz exp( ik = 4πµ R α R) 2J1( kα a sinθ ) [ ] k asinθ α 2 2 2 ( β / α ) cosθ[1 2( β / α ) sin θ ] 2 2 2 3 2 2 2 [1 2( β / α ) sin θ ] + 4( β / α ) sin θ cosθ[1 ( β / α ) sin θ ] and. For a uniformly where is pressure wave velocity, is the shear wave velocity, is the compression wave number and is the stress at the surface of the transducer. Since is unknown, the displacement is normalized with respect to its value at. Divergence of the emitted beams at different frequencies in a polar coordinate system is shown in figure (3) where with the increase of frequency, the angle at which the first cancellation point occur decreases. In other words, higher frequencies diverge less than lower ones. The cancellation points are caused by destructive interference of waves originating from different points on the transducer surface [9]. Each emitted ray from the transducer includes a spectrum of frequencies, therefore, rays which travel at different angles with respect to the central axis of the transducer have different frequency spectra and consequently echoes reflecting back from these rays have different shapes. 1/ 2 (3) f = 2MHz f = 5MHz f = 10MHz 3

Figure 3- Wave distribution from a flat transducer is a function of frequency To explain this phenomenon, we can assume an aluminum half cylinder shown in figure (4). A transmitting ultrasonic transducer is placed at the center of half cylinder, and an identical receiving transducer can swipe the outer surface of cylinder along the periphery of the half cylinder. By assuming a Gaussian impulse response for the measurement system, the captured signal at different angles will be as shown in figure (5). Transmitter θ Receiver Figure 4- Configuration of setup for collecting signals at different angles θ = 0 o θ = 7.5 o Amplitude Amplitude 0 5 10 15 20 f MHz 0 5 10 15 20 f MHz θ = 12.5 o θ = 17.5 o Amplitude Amplitude 0 5 10 15 20 f MHz 0 5 10 15 20 f MHz Figure 5- Comparing Frequency spectrum of different angles of aluminum half cylinder of figure (4) Considering the wide beam spread of ToFD transducers, echoes which return from different angles have different frequency contents and consequently different shapes. Therefore, it would not be appropriate to use a fixed reference signal for deconvolving echoes which appear in different parts of 4

the ToFD signal. The following experiment was set up to show the change of the frequency spectra at different parts of the ultrasonic beam (Figure 6). In this experiment, an angle-beam probe is used as the transmitter. A normal-beam probe receives the ultrasonic signal on the side wall of the specimen. The transducers are identical with central frequencies of 10 MHz and diameters of 0.25 in. Transmitter S =70 mm h H = 79 mm Reciever Figure 6- Experimental set-up for measuring the variation of beam shape The frequency spectra of the signals received at different depths are shown in figure (7). Figure 7- Frequency spectra of received echoes at different depths As illustrated in figure (7), echoes received at different depths have different frequency spectra. However, ToFD signals can be modeled as nonstationary or time-varying signals. So it is necessary to provide a suitable signal processing method to improve the time resolution of each echo. The 5

angle-dependent deconvolution technique is one of these methods in which the reference wavelet used for each part of the signal is chosen to be different from wavelets used for other parts. Angle dependent deconvolution To carry out a deconvolution process, first a reference wavelet should be chosen. For ToFD signals, this reference signal could be the lateral wave or backwall echo. However, since these two echoes have completely different frequency spectra and consequently different shapes, using each echo as the reference wavelet lead to a different result. Apparently, each echo would be a more suitable reference wavelet for flaws which lie in the vicinity of the location where the reference wavelet is coming from. To account for difference in the shape and frequency content of the echoes, one can use different reference wavelets for processing echoes which come from different parts of the specimen. For this purpose, we need to have a library of reference signals to be used for various parts of the returned signal. Using this library, each echo in the ToFD A-scan signal can be deconvolved by an angledependent deconvolution process. To apply the angle-dependent deconvolution process, the ToFD signal is divided into a number of windows and each window is deconvolved by its corresponding reference wavelet. The processed windows are then put together by applying an inverse Fourier transform in time domain. Results a) Simulated signal In the signal shown in figure (8a), we consider two echoes each having a different shape. In figure (8b) and 8(c), the signal shown in figure (8a) is processed with reference wavelets which resemble the first and second echo, respectively. We observe that, when the first echo is used in the deconvolution process, figure (8b), the resolution of this echo has noticeably improved. The same applies to figure (8c), where the resolution of the second echo has become much better than the first echo. Therefore, it can be concluded that for improving the quality of the whole signal, one needs to use more than one reference wavelet. In real situations, it means that in the calibration process, we have to measure echoes form a number of reflectors lying at different depths of the calibration block. Each of these reference wavelets should then be used for processing a certain section of the signal. 6

(a) 0 5 10 15 20 25 (b) 0 5 10 15 20 25 (c) 0 5 10 15 20 25 Time (µs) Figure 8- (a) Ultrasonic testing signal with two echoes with different pulse shapes, (b) signal processed by choosing the first echo as reference, (c) signal processed by choosing the second echo as reference. b) Experiment To demonstrate the effect of the choice of the reference wavelet an experimentally measured ToFD signal is processed by the deconvolution technique in this section. The ToFD signal is chosen from a taken from a single V-groove plate weld of 12 mm thickness. A centerline crack is implanted in the weld as shown in the B-scan image of the weld as shown in figure (9). Two identical longitudinal angle-beam probes with center frequencies of 8 MHz and diameters of 3 mm were used in a configuration similar to that shown in figure (1). The raw ToFD signal collected from the crack is shown in figure (10a). In figure (10b), the raw signal is processed by using the lateral echo as the reference wavelet and in figure (10c), the backwall echo is used for this purpose. The raw signal was then divided into two different sections. The first section was deconvolved by the lateral echo and the second section was deconvolved by the backwall echo. These two processed sections were then combined together by applying an inverse Fourier transform in the time domain as shown in figure (10d). This procedure has improved the time resolution and signal-to-noise ratio of the ToFD signal quite noticeably. If required, the number of windows can be increased to cover a wider range of wavelet references. 7

Chosen A-Scan Figure 9- ToFD B-scan of a single V-groove plate weld (a) 0 1 2 3 (b) x 10-6 0 0.5 1 1.5 2 2.5 3 (c) x 10-6 0 0.5 1 1.5 2 2.5 3 (d) x 10-6 0 0.5 1 1.5 2 2.5 3 Time (µs) Figure 9- a) Raw ToFD signal, (b) deconvolution with lateral wave as reference wavelet, (c) deconvolution with backwall echo as reference wavelet, and (d) angle-dependent deconvolution Conclusion A signal processing technique which incorporates a combination of Wiener filtering and autoregressive spectral extrapolation has shown to be quite effective in improving the time resolution and signal-to-noise ratio of ultrasonic signals. Application of the deconvolution process is based on the choice of a reference wavelet. In some applications, including ultrasonic time-of-flight diffraction (ToFD) technique, due to the varying nature of the echoes that arrive from different directions of the beam, use of one single reference wavelet would not produce acceptable results. Therefore, it is necessary to use different wavelets for deconvolving different parts of the signal. The angle dependent deconvolution method which is proposed in this paper can overcome this problem. In this method, the signal is broken into a number of windows and each window is processed separately. Signals in the processed windows are then put together by applying an inverse Fourier transform in the time domain. Using both simulated and experimental ToFD signals, the effectiveness of the proposed method in improving the ultrasonic signals was demonstrated. 8

References [1] J. P. Charlesworth, J. A. G Temple, Engineering Applications of Ultrasonic Time-of-Flight Diffraction, Great Yarmouth: Galliard, 1989. [2] J. Chen, Y. Shi, S. Shi, Noise analysis of digital ultrasonic nondestructive evaluation system, International Journal of Pressure Vessels and Piping, 76, pp. 619 630, 1999. [3] F. Honarvar, H. Sheikhzadeh, M. Moles, A.N. Sinclair, Improving the Time-Resolution and Signalto-Noise Ratio of Ultrasonic NDE Signals, Ultrasonics, 41, pp. 755-763, 2004. [4] V. L. Newhouse, N. M. Bilgutay, J. Saniie, and E. S. Furgason, Flaw-to-Grain Echo Enhancement by Split-Spectrum Processing, Ultrasonics, 59, 1982 [5] M.A.R. Hernandez, Ultrasonic non-destructive evaluation with spatial combination of Wigner-Ville Transformation, NDT & E International, 36, pp. 441-445, 2003. [6] S.K. Sin, C.H. Chen, A Comparison of Deconvolution Techniques for the Ultrasonic Nondestructive Evaluation of Materials, IEEE Trans., 1(1), pp. 3-10, 1992. [7] S. S. Peng, Q.P. Wen, Wavelet Based Noise Suppression Technique and its Application to Ultrasonic Flaw Detection, Ultrasonics, 44, pp. 188-193, 2006. [8] L. W. Schemerr, Fundamentals of Ultrasonic Nondestructive Evaluation, Plenum Press, pp. 3-13, 1998. [9] F. Farzbod, "Enhancement of Ultrasonic B-scan Images", M.A.Sc. Thesis, University of Toronto, 2003. [10] X.M. Tang, M.N. Toksoz, C.H. Cheng, Radiation patterns of compressional and shear transducers at the surface of an elastic half-space, JASA, Vol. 95, pp. 71-76, 1994. 9