E-PLEX 3X00 SERIES NARROW STILE LOCK INSTALLATION INSTRUCTIONS

Similar documents
SERIES. Installation Instructions

Installing Your Electronic Deadbolt

Entry Mortise Lock Set Lever to Lever

Passage Mortise Lock Set Lever to Lever

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

Hardware Installation. Do this first:

Installation Instructions For The 8850FL Series Mortise eboss

INSTALLATION INSTRUCTIONS CRL JACKSON

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

INSTALLATION INSTRUCTIONS CRL JACKSON

CM5500 COMPUTER MANAGED MORTISE LOCK INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS CRL JACKSON

Shepherd 210A Fingerprint Door Lock Installation Manual V1.1

Installation Instructions for 45H & 47H Mortise Locks

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

00108/00110 INSTRUCTION MANUAL

Entry Mortise Handleset

Security Products & Services...That Never Sleep. Sur-Lock. I/O 2000L Family of Exit Control Alarm Locks. Installation Instructions

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

SD-996C-NUVQ Electric Door Strike with Vertical Adjustment

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

LET S GET STARTED INSTALLATION GUIDE

CM5100 COMPUTER MANAGED CYLINDRICAL LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

Phone # La Jolla Doors. Block Frame Installation Manual Aluminum Frame with either Vinyl or Aluminum Panels

Installation Instructions For Profile Series v.g1 Cylindrical Lock

INSTALLATION INSTRUCTIONS

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Wood Doors. Wood Doors ASSA ABLOY.

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set

PMR ELECTRONIC LOCK USER GUIDE

120x165mm. 85x165mm TEMPLATE. ELECTRONIC DEADBOLT model no.: & & Toll-free Number:

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

Installation Instructions For Profile Series v.g1 Exit Device

Video Wall Installation Instructions 2W X 3H, 3W X 3H

WD WD7000 Series

1530(F) Mortise Exit Devices Installation Instructions

Installation Instructions

EE1000 SERIES INSTALLATION INSTRUCTIONS

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

Congratulations! You are now on your way to enriching your life with! Figure #5. Step 5 Install the Dummy Deadbolt. Step 3 Drill the Door

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

INSTALLATION MANUAL. All Recessed Wall-Mount Modules Front-Loading, Rear-Loading, Parcel-Only, Collection Box, Trash/Recycling Bin

Congratulations! You are now on your way to enriching your life with!

Door Hardware Installation Instructions. For Assistance Call:

Retractable Screen Installation Instructions For Vinyl and Aluminum Clad and Wood In-Swing Hinged Doors (See separate instructions for sliding doors)


INSTALLATION INSTRUCTIONS

Installation Instructions

Tilting & Swiveling Plasma/LCD Flat Panel Wall Mount Installation Guide Model: A380SM

HARDINGE Installation booklet For: Dead-Length Collet Adaptation Chucks Stationary Collet

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Model 2740B High Security Safe Lock. Installation Instructions. Mounting Considerations:

INSTALLATION INSTRUCTIONS

CM5500 COMPUTER MANAGED MORTISE LOCK HARD-WIRED (FSE/FSA) INSTALLATION MANUAL

Fletcher F-3000 / F-3100 Accessory Laser Kit

1.0 Tool Components and Operation Instructions

INSTALLATION INSTRUCTION

CL4500 Installation Instructions

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

VersaRail Gate Kit. freedomproduct.com. To register your product, please visit: INSTALLATION INSTRUCTIONS

Adams rite. Deadbolts, Deadlocks & Hookbolts Series maximum security laminated deadlocks/hookbolts

Installation and Assembly: Articulating Swivel Arm for 37" - 60" Flat Panel Displays

INSTALLATION INSTRUCTIONS Medium Flat Panel Model MSP-SI1

Tilting, Swiveling & Rotating Flat Panel Wall Mount

INSTALLATION INSTRUCTIONS

Ringblaster Mark IV Maintenance Guide. Version 1.5

Adams Rite. Standard & Heavy Duty Deadlatches Series Heavy Duty Deadlatch

Assembly Instructions and Parts Manual JPSF-1 Fence and JPSR Rail Set #

RULTRACT RETRACTOR CABLE REPLACEMENT INSTRUCTIONS. Rultract, Inc. is the ONLY authorized service center in the U.S.A.

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

OWNER S MANUAL. Safety. Please read this owner s manual before use and keep it at hand for reference. Warranty

RETAIN PACKAGING DURING INSTALLATION Do NOT discard packaging materials until installation is complete CONTACT US BEFORE RETURNING

HIT-30 ALUMINUM DOOR SERIES OWNERS MANUAL

Gared Pro-S Portable Backstop

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

Rim-Lock Door Set Installation Instructions

IF YOU DO NOT KNOW WHAT YOU ARE DOING, DO NOT DO IT!

Installation Procedures For Corvette Basic/C-6 SNS 28

Installation Instructions

Models 2230 and 2240

Installers guide Deadbolt 02.

Installation Instructions Cage Kit JK Unlimited (4-Dr) Part # 76902

SIDE FOLDING POST ADJUSTMENTS

INSTALLATION INSTRUCTIONS

MANCHESTER VANITY BASE

MP Panic Exit Police Lock. Review Of March 2004 Installation

STRINGING MACHINE OWNER'S MANUAL. Copyright 1998 GAMMA Sports - All Rights Reserved

PGS20/42 Series Grippers

SS/SW3230RTA Assembly Instructions Ready to Assemble Multimedia Lectern

Installation Procedures Maserati Gran Turismo Sport SNS 85

SLW 6 Channel Letter Brake. User Guide. Operation and Mounting Instructions

Transcription:

E-PLEX 3X00 SERIES NARROW STILE LOCK INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS Tools Required.................................................................3 A. Door Preparation - Remove Existing Outside Hardware..........................3 B. Stile Preparation...........................................................5 C. Lock Preparation...........................................................6 D. Lock Installation...........................................................13 E. Standard Operations Procedures.............................................15 F. Programming and Software Settings.........................................15 E-PLEX 3x65 Deadlatch/Exit Mortise Model E-PLEX 3x66 Deadbolt/Swing Bolt Mortise Model This lock is designed to function with new or existing Adams Rite Hardware for Deadlatch, Deadbolt, and Exit applications. These Adams Rite Hardware models (1850, 1950, 4500, 4700, 4900, MS1850S, MS1950S, and 8400 Series) are sold separately. The specific applications for this model are for narrow stile aluminum and glass doors, 2 minimum width and 1 3 4 thick. WARNING: This lock is designed to be used with Adams Rite brand hardware only. Improper use or installation of this product will void the warranty. Shipping Package Includes (See Figure 1): (1) E-Plex 3x00 Lock Assembly (1) Outside Lever (Lever Model Only) (1) Screw Pack (1) Battery Housing with four AA Batteries (alkaline) (2) Keys (Schlage C or Kaba 90 Keyway) Documentation pack consists of: (1) Installation Instructions (this manual) (1) Operations Manual (1) Lock Set-up Guide (1) Quick-Reference Guide a. 54579 Upper Mounting Screws (2) b. 44229 Mounting Bushings (4) c. 54275 Lower Mounting Screws (2) d1. 75271 Kaba Cam Plug Deadlatch (1) a d2. 75262 Kaba Cam Plug Deadbolt (1) e1. 75272 Lock Assembly for Lever (1) e2. 75273 Lock Assembly with Thumbturn (1) f. 54725 Pinned Torx Screw (2) b g. 34298 Lever Cap (1) h. 34309 Lever (1) i. 44226 D Bushing (2) j. 54685 Battery Pack (1) k. 24554 Battery Cover (1) c l. 54725 Pinned Torx Screws (1) e1 e2 d1 d2 f 2 LEVER LOCK ONLY Figure 1 j k l i h g

TOOLS REQUIRED Power Drill with 3 8 (10mm) drill bit Tape Center Punch or Awl Hex Allen Wrench Set Phillips Head Screwdriver Small Flat Blade Screwdriver Safety Glasses A. DOOR PREPARATION REMOVE EXISTING OUTSIDE HARDWARE A-1 Remove any existing Outside Hardware such as Lever Entry Trim, Latch Pull, Key Cylinders, etc. A-2 Remove and retain the screws and Armored Face Plate (Scalp) from the face of the Deadlatch (See Figure 2A) or Deadbolt (See Figure 2B). A-3 Loosen the set screw and remove the existing hardware assembled from the outside to the Deadlatch or Deadbolt Mortise, including the Adams Rite Cam Plug 4580 (d). A-4 Set Scalp and screws aside for reassembly later. Figure 2A Figure 2B set screw d set screw screws screws scalp scalp Disclaimer: While reasonable efforts were made to ensure the accuracy of this document at the time of printing, Kaba assumes no liability for any errors or omissions. This information is subject to be revised without notice, and changes may be incorporated in future releases. 3

KABA E-PLEX 3x00 SERIES LIMITED WARRANTY KABA ACCESS CONTROL WARRANTS THIS PRODUCT TO BE FREE FROM DEFECTS IN MATERIAL AND WORKMANSHIP UNDER NORMAL USE AND SERV- ICE FOR A PERIOD OF THREE (3) YEARS. KABA ACCESS CONTROL WILL REPAIR OR REPLACE, AT OUR DISCRETION, E-PLEX 3000 SERIES LOCKS FOUND BY KABA ACCESS CONTROL ANALYSIS TO BE DEFECTIVE DURING THIS PERIOD. OUR ONLY LIABILITY, WHETHER IN TORT OR IN CONTRACT, UNDER THIS WARRANTY IS TO REPAIR OR REPLACE PRODUCTS THAT ARE RETURNED TO KABA ACCESS CONTROL WITHIN THE THREE (3) YEAR WAR- RANTY PERIOD. This warranty is in lieu of and not in addition to any other warranty or condition, express or implied, including without limitation merchantability, fitness for purpose or absence of latent defects. ATTENTION: This warranty does not cover problems arising out of improper installation, neglect or misuse. All warranties implied or written will be null and void if the lock is not installed properly and/or if any supplied component part is substituted with a foreign part. If the lock is used with a wall bumper, the warranty is null and void. If a doorstop is required, we recommend the use of a floor secured stop. The environment and conditions of use determine the life of finishes on Kaba Access Control products. Finishes on Kaba Access Control products are subject to change due to wear and environmental corrosion. Kaba Access Control cannot be held responsible for the deterioration of finishes. Authorization to Return Goods Returned merchandise will not be accepted without prior approval. Approvals and Returned Goods Authorization Numbers (RGA Numbers) for the E-Plex 3x00 Series are available through our Customer Service department in Winston-Salem, NC (800) 849-8324. The serial number of a lock is required to obtain this RGA Number. The issuance of an RGA does not imply that a credit or replacement will be issued. The RGA number must be included on the address label when material is returned to the factory. All component parts must be included in the package with return. All merchandise must be returned prepaid and properly packaged to the address indicated. 4

B. STILE PREPARATION B-1 Install the Kaba Cam Plug d1 or d2 into the Deadlatch or Deadbolt. Face of Cam Plug must be flush or below the surface of the stile, make sure set screw is snug but do not tighen it yet. (See Figure 2 on page 3). Note: Refer to the Adams Rite Cam Plug Instructions for Right Hand/Left Hand Installations (located in the Screw Pack). (For Deadlatch Models) B-2 Affix the appropriate model Template to the outside face of the door stile. Ensure the pins from the Cam Plug are through the proper holes, the template is straight and aligned with the edge of the door, and that TOP is facing up and BOTTOM is facing down (See Figure 3). B-3 With a center punch or awl, mark the four drilling points. B-4 Utilizing a power drill with 3 8 drill bit, drill four holes as marked completely through the door (interior and exterior of the stile). Tip you may want to first, drill pilot holes, then drill from each side to keep holes straight through and minimize burrs. Flush or Below For Deadlatch Model, use template 64782. For Deadbolt Model, use template 64783. Figure 3 5

C. LOCK PREPARATION C-1 On Deadlatch Model only, remove Handing Screw (FIG 4): Caution: The appropriate handing screw must be removed for proper lock function after installation. Inside the battery compartment, the lock comes with both handing screws installed. Based on the door application handing, Left Hand (LH) or Right Hand (RH) one screw must be removed as noted in FIG 4. Deadbolt Models, are shipped with no handing screws attached. If present, they must be removed for Deadbolt applications. Note: A RH Deadlatch lock is shown in FIG 4. For Deadlatch Locks only, orient the lock as shown in FIG 4 (spindle up) and remove the appropriate shipping screw, left screw for LH or right screw for RH. Remove left handing screw for left hand application. Note: Right Hand application shown, Left Hand application would show the lever on the opposite side. Spindle Assembly: Deadlatch Upper Hole (Deadlatch assembly shown) Deadbolt Lower Hole Remove right handing screw for right hand application. Note: Right Hand application shown. Figure 4 C-2 Battery Pack Installation Secure the connection end of the Battery Pack to the Cable Harness. After the connection, the lock will set itself and you should hear an audible sound, spinning of the inside motor, and see a green light all simultaneously. Upon connection, place the Battery Pack into the rubber battery housing, harness connection up, and slide the assembly into the battery compartment (see Fig 5). Secure in place with the Battery Cover and Torx Screw. The lock can now be programmed prior to installation if desired. Figure 5 6 Note: If your application requires a change of cylinder, that step should be done at this time, before installation. If not required, skip to section D.

BUSINESS REPLY MAIL FIRST-CLASS MAIL PERMIT NO. 1563 WINSTON-SALEM, NC POSTAGE WILL BE PAID BY ADDRESSEE KABA ACCESS CONTROL 2941 INDIANA AVENUE WINSTON-SALEM, NC 27199-3770 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES

REGISTRATION CARD Thank you for purchasing our product. In order to protect your investment and to enable us to better serve you in the future, please fill out this registration card and return it to Kaba Access Control, or register online at www.kabaaccess.com. Name Position Company Address City State ZIP (Postal Code) Country Phone Email Name of Dealer Purchased From Date of Purchase Lock Model Number This lock will be used in what type of facility? Commercial Building Industrial / Manufacturing Airport College/University Government/Military School/Educational Hospital/Healthcare Other (please specify) What area is being secured with this lock? (e.g. Front Door, Common Door, Exercise Room) This lock is: New Installation Replacing a conventional keyed lock Replacing a Kaba Mechanical Pushbutton Lock Replacing a Kaba Electronic Access Control Replacing a Keyless Lock other than Kaba How did you learn about Kaba Access Control Pushbutton Locks? Advertisement Previous Use Internet / Web Another Use Locksmith Maintenance Training Class Other (please specify) What was your reason for buying this lock? Who installed your lock? Locksmith Maintenance Other Check here if you would like more information on Kaba Access Control locks.

Notes 9

C-3 Changing the Key Cylinder: A standard, factory installed cylinder (54450) has been provided with the E-Plex 3000. To change/replace the cylinder, carefully follow the steps below. 1. Change Master Code and place lock in Passage Mode. STEP 1. Enter # to Start the Programming Mode STEP 2. Enter the 8-Digit Factory Default Master Code: 1 2 3 4 5 6 7 8 # STEP 3. Enter Change Master Code Code Command: 0 0 0 # STEP 4. Enter New 8-Digit Master Code: 8 7 6 5 4 3 2 1 # STEP 5. Reenter New Master Code to Confirm: 8 7 6 5 4 3 2 1 # STEP 6. Enter Code Command: 399 # 1 # to Activate Passage STEP 7. Enter # to Exit Programming 2. With a Phillips Head screwdriver, remove and retain the Cylinder Locking Screw (54746) that secures the factory installed cylinder into the housing. (Fig s. 6, 7, and,8) Figure 6 Figure 7 Figure 8 Removed Cylinder Locking Screw (54746) Cylinder Locking Screw Access Hole Cylinder Locking Screw (54746) as assembled 3. Remove the existing cylinder from the housing assembly. Tip: You can insert the key half way into the key way and use it as a tool to aid in rotating the cylinder out far enough to remove it by hand. 4. Inside the cylinder hole of the housing, ensure the Key Override Cam is positioned clear (Fig s 9 & 10). Key Override Cam 10 Ensure that the Key Override Cam is completely out of the opening, as shown, so that the key cylinder will be able to be correctly assembled. Figure 9 Figure 10 10

5. Orient the lock to keep the Key Override Cam clear and insert the new cylinder (Fig 11). Allow gravity to assist in keeping the Key Override Cam out of the opening. Figure 11 6. Insert the new cylinder all the way until the MS Cam bottoms out on the Gear Pack. Once it bottoms out, back rotate the cylinder until the plug is at the Six O clock position. (Fig s 12, 13, and 14) Gear Pack Six o clock postion A/R MS Cam Figure 13 Figure 12 Figure 14 7. Clear the lock out of Passage Mode. STEP 1. Enter # to Start the Programming Mode STEP 2. Enter the Master Code: 8 7 6 5 4 3 2 1 # STEP 3. Enter Code Command: 399 # 0 # to De-activate Passage STEP 4. Enter # to Exit Programming 8. Test the function of the cylinder by holding the cylinder in place and rotating the key 90 degrees clockwise. The Lever or Thumb Turn should be able to freely move, as if you were opening a door. Return the key to its original position and remove. Attempt to rotate the Lever or Thumb Turn. The lock should remain secure. 9. If lock performs adequately, secure cylinder in place with the original cylinder locking screw. Screw must be fully inserted, bottoming out on the cylinder/housing. If the lock fails to perform as intended, place the lock back into passage mode and return to step #3. 11

D. LOCK INSTALLATION Figure 15a (See Figs. 15a, b, and c) Note: This step is to be done with the door open. D-1 From the Screw Pack, place d-1 a the two Mounting Bushings (b) into the upper, interior 3 8 holes. b D-2 Deadlatch: Place one end of the square spindle into the upper hole of the lock (marked L on backplate) Deadlatch j and the other end into the square opening of the Cam c k Plug (d-1), bringing the lock l towards the face of the stile until the two pins of the Cam Plug mate Figure 15b into the two holes of the lock mounting plate. a Deadbolt: Align spindle end of cam (d-2) to lower hole of the lock (marked B on backplate) bringing the lock towards the face of the stile until the two pins of the Cam Plug mate into the two holes of the lock mounting plate. D-3 From the Screw Pack, place two Mounting Plate Bushings (b) into the lower, interior 3 8 holes. D-4 Secure the upper portion of the lock to the stile with two 10 24 x 2 3 8 screws (a), inserting b c Figure 15c d-2 Interior the screws directly into the upper Hardware portion of the lock. (not provided) D-5 From the screw pack place the mounting plate bushings (i) through the D shaped holes and Through the lower, interior 3 8 holes. D-6 Secure the lower portion of the lock to the stile with two 10 24 x 1 1 2 screws (c), inserting the screws into the other two Deadbolt Mounting Plate Bushings (b). 12 e-1 h i i f g e-2 e-2

D-7 Locks with Levers Based on the required handing of the lock as determined in section C, install the Lever (h) and Lever Cap (g) using torx screws (f) and provided torx wrench. Secure lever cap (g) with Allen Set Screw using supplied Allen wrench. (See Figure 16) D-8 Check for proper operation of the lock using thumbturn/lever with key in override cylinder turned to the three o clock position. Once smooth lock operation is verified, tighten cam adjustment screw on mortise face and re-install Adams Rite Scalp with 2 or 3 screws. D-9 Before closing the door, refer to Section E Standard Operating Procedures, to ensure proper function. e a d f b h g i j c k l Figure 16 13

E. STANDARD OPERATING PROCEDURES E-1 This lock is equipped with a standard break away clutch. In the home position, the lever or thumb turn is horizontal to the floor with the ability to break away down to a detented position as the lever or thumb turn is rotated. This break away action protects internal components. Note: Before entering a code, the lever or thumb turn should be positioned horizontal to the floor (home position). (See Figure 17) E-2 Enter the factory default Master PIN (access code) by depressing the appropriate code buttons. With each button depression you should hear a short audible beep, and see a green light at the top right of the number pad. Once the last button in the code is depressed, you will hear a longer audible beep and internal motor action releasing the locking device. At this point, you have 5 seconds to retract the latch or the lock will time out and go secure. E-3 For Dead Latch Models (Figure 17), the handing screw does not allow the lever/thumbturn to rotate up. To Retract Dead Latch: Enter code or present card Rotate lever or thumbturn down 45 o E-4 For Dead Lock Models, there are no handing screws. To Throw Deadbolt: Enter code or present card Rotate lever or thumbturn down 45 o To Retract Deadbolt: Enter code or present card Rotate lever or thumbturn up 45 o Figure 17 14 Figure 18 Figure 19

F. PROGRAMMING AND SOFTWARE SETTINGS: F-1 You must change the master Code from the factory default to another code to program the lock. For further information on how to manually program the E-Plex 3x00 Series Models, refer to the companion E-Plex 3x00/5x00 Operation Manual. Software is required to program the E3200 Series Locks. F-2 When configuring the E3000 Series Locks using the optional Standard Software, choose the box that contains Entry Lock with Passage (Cylindrical or Mortise without Deadbolt) during lock setup. F-3 When configuring the E3200/3700 Series Locks using the Advanced Software, select the Cylindrical or Mortise without Deadbolt box during lock setup. 15

Kaba Access Control 2941 Indiana Avenue Winston-Salem, NC 27105 USA Tel: (800) 849-8324 (336) 725-1331 Fax: (800) 346-9640 (336) 725-3269 www.kabaaccess.com www.e-plexlock.com PKG3215 0409