EE1941XS/EN1941XS One-Way Serial RF Module Installation and Operation Manual

Similar documents
EE1941/EN1941/EN One-Way Binary RF Module Installation and Operation Manual

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual D

EE1941/EN1941 One-Way Binary RF Module Installation and Operation Manual E

Murata Bluetooth mesh Node. Installation Guide

APM 6998 WiFi Module Manual

User s Manual Wireless Keyboard/Mouse & NANO Receiver MD-5110/MM-5110 & DG-5110

Transponder Reader TWN4 MultiTech 3 Quick Start Guide

LOUIS VUITTON 1. Louis Vuitton Echo, locate your Horizon luggage in airports Battery indicator light. Light sensor to detect opening

CARE +MAINTENANCE Cleaning Important Safety Instructions Water Drop Heat Battery Charging Repair

General Safety and Precautions 1. Read all of the information in the owner s manual and other included product information in the packaging before

Icon Description UP ( ) 1 BACK ( ) 4 PAGE ( )

Vehicle IoT Gateway VG34 DATASHEET OVERVIEW HIGHLIGHTS

User Manual. 1. Introduction. 2. Features

16+ HS300. Instructions for use. One Key Start/One Key Landing Function Headless Mode / One Key Return Altitude Hold Mode

Link Mobile Gateway User Guide A ProVIEW System Component

5.8G Wireless Audio Transceiver/Receiver Module DWHP83

DOWNLOAD KASA ADD TO KASA INSTALL AND POWER UP SAFETY FIRST

DCH-G020 mydlink Connected Home Hub

FOR TRAINING PURPOSES ONLY DATED MATERIAL. Aperio Hub AH20/AH30 Installation Instructions. ASSA ABLOY, the global leader in door opening solutions

ACUII-06 User Manual (NAS)

User Manual. 1. Introduction. 2. Features

Polycom VoxBox Bluetooth/USB Speakerphone

Wireless Compliance Statements

PA421B PA821B. Front Panels. Included Components. Features. Model Variations. Antenna Combiner

HistoCore SPECTRA CV. RFID-Registration Registro de RFID Registro RFID تسجيل التعريف عن طريق الترددات الالسلكية

Blue Node. User Manual

testosaveris 2 User Manual testo Saveris 2Introduction

MOVADO.COM/SMARTSUPPORT

RFC1000-CE Cloud Relay. MadgeTech Cloud Services Data Logger Hub. Product User Guide

User Manual. MITSUMI WiFi Module MODEL DWM-W081

StreamStick by NAV-TV is a USB-powered, HI-FI Bluetooth 4.0 audio streaming module for automotive and home use. Make ANY stereo (equipped with AUX

Electronic Emission Notices

802.11a/n/b/g/ac WLAN Module AMB7220

Evaluation Kit ATA8520-EK1-F and Extension Board ATA8520-EK3-F (US Version) Kit Content ATAN0157 APPLICATION NOTE

BT11 Hardware Installation Guide

User guide. SmartTags. NT3/SmartTagsST25a

Pser G uide oduct Manual

System overview. be connected: Components that can. 1. OKIMAT IPS OM Massage motor. 7. Optional: Junction cable

FMT4R FM Transmitter User s manual

GNSS multiconstellation, GPS+Glonass as a minimum; GSM; Accelerometer; SIM on Chip; Watch Dog; Power Management; RF transceiver; CAN Bus interface

v Pairing Instructions for: GENERAL MOTORS REPLACEMENT FLIP KEYS

Need Help? SA /

EE4216MR 16 Zone Multi-Condition Receiver with Relay Outputs Installation and Operation Manual

1. Constitution of the Unit Assy-Wireless Charging ( WPC ) for vehicle

260X190mm/105 克铜版纸 / 黑白印刷

1100DH High Power Wireless Receiver

INSTALLATION MANUAL ES-SUB-WIRELESS-KIT ES-SUB-WIRELESS-RCVR

Regulatory Compliance Statement

EASYFIT Bluetooth Single / Double Rocker Wall Switch

FCC Certification Notice: IC Certification

EE4232MR 32 Zone Multi-Condition Receiver with Relay Outputs Installation and Operation Manual

StreetSounds STS-170-MMST Mobile Master. User Guide

WIFI Control box UserManual

FOR AVLEX ONLY MT-24A. User Guide. 2.4 GHz Digital Stationary Transmitter

Shields. Outdoor Shields Owner s Manual. Avoidance Solutions.

Tork EasyCube. User Manual.

XT-4850C FCC ID: GKM-XT4850C IC: IC: 10281A-XT4850C

TomTom Touch Fitness Tracker User Manual

6505 MICRO. Amplifier. Operating Manual.

ihealth Wireless Body Analysis Scale OWNER S MANUAL

Pushbutton Transmitter Device PTM 215Z. September 17, 2013 USER MANUAL V1.0. Patent protected: US 6,747,573 US 7,019,241 Further patents pending

OPERATION MANUAL WARNING

Regulatory Compliance and Important Safety Information

User Guide. Do not copy or forward without prior approvals MIPRO. Specifications and design subject to change without notice.

NV-WA40W. Installation and User Guide

or call

STREETSOUNDS STS-170-FMST USER GUIDE V1.0. Fixed Master STS-170-FMST. User Guide V1.1 August 25,2018

BT50 Datasheet. Amp ed RF Technology, Inc.

LoRa Module Datasheet

Pushbutton Transmitter Device PTM 215 ZGPGP. June 10, 2014 USER MANUAL V1.0. Patent protected: US 6,747,573 US 7,019,241 Further patents pending

MorningLinc INSTEON Morning Industry RF Doorknob/Deadbolt Controller

PowerView Remote Control Guide

HOBO RX Wireless Sensor Network HOBO RXW Repeater (RXW-RPTR-xxx) Manual

This device should be installed and operated with a minimum distance of 20 cm to your body.

Sure Cross Radio Certifications

800 Series Transmitters Owner s Manual

SYSTEM REQUIREMENTS (Windows) Windows XP(Service Pack 2 or later) or vista 3.2GHz Pentium 4 or faster Minimum 1GB of system RAM

VIBRATION AND TEMPERATURE SENSOR (FY01) USER GUIDE (For FCC/IC Certification) Version: 0.7

OEM Compact Handheld Transmitter Data Guide

DS Keyfob Transmitter Data Guide

Regulatory Compliance Addendum for the Multi-Mode Wireless LAN Unit (WLU-2100)

Alcatel-Lucent 8340 Smart IP-DECT AP. Installation Manual

READ ME FIRST QUICK INSTALL GUIDE. Wireless Controller Kit XWS Package Contents:

User Guide. ACT-50H / ACT-52H Handheld Transmitter

SATELLITE RADIO OWNER'S MANUAL. Type III Radio

MS Long-Range Handheld Transmitter Data Guide

Copyright Autoliv Inc., All Rights Reserved

OEM Long-Range Handheld Transmitter Data Guide

SAR TX1. AIS SEARCH AND RESCUE TRANSMITTER User Manual

ISTATION-N (Integration Station) User Manual

SIMATIC Ident RFID systems SIMATIC RF310R special version Scanmode Compact Operating Instructions

AN-CPA70 Plus Cell Phone Signal Booster User Manual

VDBTLE24. BTLE Single Mode Module with USB. Description. Applications

1. Open Mi Drone APP, select Next button. 1. Connect MiRC_XXXXXX device, the default key is

2011 Shure Incorporated 27A15021 (Rev. 2) *27A15021* Printed in China

Illuminati Wireless Light and Color Meter Model IM100. User Manual

Link Network Gateway User Guide

User Manual for 24 GHz Blind-Spot Radar Sensor

TYWE2S DATASHEET. TYWE2S UserManual

Ethernet Gateway User Manual

Transcription:

EE1941XS/EN1941XS One-Way Serial RF Module Installation and Operation Manual 1 Overview EchoStream RF modules are designed to be easily interfaced with your electronic remote application controller (RAC). Your RAC contains application specific functionality and uses the RF module to send application-specific data over the wireless network. The RF module communicates with your application controller via a wireless connection, and your remote application controller via a serial connection, allowing the assimilation of any user-specific application into an EchoStream system. Once integrated with an existing product, an RF module provides you with complete EchoStream functionality. The E*1941XS, equipped with the UART logic-level serial connection, is primarily intended for use as a daughter board, interfacing directly with your RAC. The EE1941XS, for 868 MHz applications in Europe. B C D E F G H A K I J O L M Figure 1 One-Way System Components 1.1 Maximum Number of Repeaters for a UL 2560 Installation To achieve the 99.99% alarm message reliability required for UL 2560 compliance, system installations must operate within the following limits for end device and repeater counts. End Devices Maximum Repeaters 150 397 250 386 350 375 500 360 1000 313 2000 238 3000 184 1.2 Inovonics Wireless Contact Information For product and installation videos visit us at www.inovonics.com/videos or use the QR code below. If you have any problems with this procedure, contact Inovonics Wireless technical services: E-mail: support@inovonics.com Phone: (800) 782-2709; (303) 939-9336 2 One-Way Serial RF Module Components The E*1941XS is a one-way serial data transmitter, designed to physically interface with your product. Serial data sent to the E*1941XS from your remote application controller is formatted by the E*1941XS, and the data is then transmitted as an RF message to the network coordinator. There are two models in the E*1941XS product family. The EN1941XS, for 900 MHz applications in North America, New Zealand, and Australia. Figure 2 EN1941XS one-way serial RF module components A Board stabilization hole. B Data output C Data input D Secondary alarm E Power F G Primary alarm H LED contacts I Tamper input J Reset input K Frequency band L Mounting hole selection pins M On-board antenna N Board stabilization hole B C D E F G H A I J K Figure 3 EE1941XS one-way serial RF module components A Board stabilization hole. B Reserved C Reserved D Secondary alarm E Power F G Primary alarm H LED contacts I Tamper input J Reset input K ES selection pins L Mounting hole M On-board antenna N Board stabilization hole Frequency band selection pins (EN1941XS only) Place a jumper to select the frequency band for your geographic area. Place the jumper on the left two pins to select 915-928 MHz for Australia. Place the jumper on the right two pins to select 921-928 MHz for New Zealand. Leave the jumper off the pins to select 902-928 MHz for North America. Reset the RF module to complete the configuration change. ES selection pins (EE1941XS only) To enable compatibility with ES products, place a selection jumper on the ES selection pins; if no ES products are used in your system, remove the selection jumper. Reset the RF module to complete the configuration change. Secondary alarm Driving pin high triggers a secondary serial alarm status message. Primary alarm Driving pin high triggers a primary serial alarm status message. Tamper input Driving pin high triggers a serial tamper status message from the RF module to the RAC. Does not trigger an RF tamper message. Reset input Connects a reset input, to reset the one-way serial data RF module after a frequency band selection change. Power Connect power cabling to an external power supply of 2.4 to 5.5 volts. Connects to ground. Mounting hole Used to mount the one-way serial data RF module to the user-specific product. The mounting hole should only be used with a nylon standoff, never metal. Board stabilization holes Used to mount and stabilize the board. The board stabilization holes should only be used with non-metal standoffs. Data output Outputs messages to the RAC. Data input Receives messages from the RAC. N L M 5.25.17 06288F Inovonics, 2017 - www.inovonics.com

3 One-Way Serial RF Module Dimensions.090 to Center of First Pin Pitch: 2.54mm..156 Diameter.515 to Center of Hole.335 to Center of Hole 1.3 H The RF module should be integrated so the antenna is unobstructed by the end user s PCB, batteries, or any other conductive material. Clear transmit region in front and back of antenna RF module.385 to Center of First Pin End user application printed circuit board.5 2.525 Figure 4 E*1941 One-Way Serial RF Module Dimensions 4 One-Way Serial RF Module Connections and Output Jumpers Primary Secondary Tamper Reset Connection Output Jumper N/C Clear Clear Tamper Tamper Clear for normal operation; connect to the ground and release for a board reset. 5 Installation A The RF module must only be connected at the eight pin header or eight pin plated thru-holes. B All cables and wires must be routed away from the component side of the RF module. C The integrated antenna must not be tampered with; no connection to an alternate antenna is provided. D The application module must not include an integrated secondary colocated radio module. E The one-way serial data RF module antenna should be placed so that it is facing away, or otherwise isolated from, your device s ground plane. F Components that are sensitive to RF transmission, such as high gain circuits, should be isolated from the antenna to prevent interference. G One-way serial RF modules should not be mounted on metal surfaces or inside metal enclosures. They should also not be mounted where sheet metal ductwork, wire mesh screens, etc. might block transmissions. Figure 5 The RF module should be integrated so the antenna is unobstructed 6 One-Way Serial RF Module Requirements 6.1 Timing Requirements All data is sent at a default rate of 9600 baud, no parity, 8 data bits and one stop bit. The data is transmitted least significant bit first. 6.2 Power Requirements The E*1941XS has an on-board voltage regulator. Connect power cabling to an external power supply (Vcc) of 2.4 to 5.5 volts. Voltage must be sustained at 2.4 volts or above and supply 100 milliamps during the transmit cycle. EN1941XS Assuming check-in messages every 3 minutes and infrequent alarm messages (one per day, on average), the average current draw is 32 ua. Peak current draw while transmitting is less than 100 ma. One alarm/restore cycle with the maximum payload size results in approximately a 23mA increase in the average current. EE1941XS Assuming check-in messages every 12 minutes and infrequent alarm messages (one per day, on average), the average current draw is 15 ua. Peak current draw while transmitting is less than 50 ma. One alarm/restore cycle with the maximum payload size results in approximately a 12mA increase in the average current. 6.3 Low Battery Condition The E*1941XS measures power supply voltage every three and a half hours, and, when the voltage measures 2.4 volts, a serial message is sent indicating a low battery condition. 6.4 Temperature Range -20 C to +60 C, non-condensing 6.5 RF Network Compatibility EchoStream Commercial Mesh Network 6.6 Payload size 50 bytes maximum 6.7 Input Requirements Caution: Input levels must not exceed 3.3 V. When an active source (open collector or dry contact) is used to drive the alarm or tamper input, the voltage should be between 0.75xVcc and Vcc. A passive input should have an impedance of greater than 5.1k ohm between the input and ground. Closed When an active source is used, the voltage should be less than 0.25xVcc. A passive input should have an impedance of less than 240 ohm. 6.8 Serial I/O - UART logic-levels Input levels must not exceed 3.3 V. Output levels are limited to 3.3 V, maximum. Data in pins Vih (minimum high level input voltage): 0.75xVcc Data in pins Vil (maximum low level input voltage): 0.25xVcc Data out pins Voh (minimum high level output voltage): Vcc - 0.25 at Ioh: -1.5mA Data out pins Voh (minimum high level output voltage): Vcc - 0.6 V at Ioh: -6mA Data out pins Vol (maximum low level output voltage): 0.25 V at Iol: 1.5mA Data out pins Vol (maximum low level output voltage): 0.6 V at Iol: 6 ma 5.25.17 06288F Inovonics, 2017 - www.inovonics.com 2

6.9 UL2560 Requirements The EN1941XS one-way serial RF module is a UL2560 unlisted component. The compatible receiver for UL 2560 installations is the EN6040-T network coordinator. Refer to the EN6040-T Network Coordinator Installation Instructions. For UL 2560 installations, the RF module must have a minimum check-in time of 60 minutes. The compatible repeater for UL 2560 installations is the EN5040-20T. In a UL 2560 installation, the EN1941XS one-way serial RF module may be used with completed emergency call systems for assisted living and independent living facilities For UL 2560 certified system installations, the following Inovonics EchoStream devices are approved for installation within maximum system configuration limits defined in section 1.1 of this document: - EN6040-T network coordinator. - EN5040-20T high power repeater. - End devices (transmitters) with a minimum 60-minute check-in interval, as follows: Fundamental devices which are subject to UL2560 certification (pendant transmitters and OEM products using the Inovonics RF module) Supplemental devices which are not subject to UL2560 system certification but which may be used within a UL2560 certified system (e.g. universal transmitters and activity sensors) Users that have achieved certification and will install UL 2560 certified systems are responsible for labeling all fundamental devices with the UL 2560 system certification mark. 9 FCC Part 15 and Industry Canada Compliance This device complies with part 15 of the FCC Rules and Industry Canada licenseexempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. 9.1 CE Label Requirements for EE1941XS Inovonics Wireless has received European Telecommunications Standards Institute approval to market one-way serial data RF modules, and they are manufactured to be RoHS compliant. The integrator is responsible for properly labeling the product containing the one-way serial data RF module. Labels must be placed on the outside of the product, and must include the CE logo. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 10 Simplified Declaration of Conformity Hereby, Inovonics declares that the radio equipment type EE1941XS is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following Internet address: www.inovonics.com 11 US Patent Numbers 7,154,866. 7,554,932. 7,746,804. Other patents pending. 7 Specifications Output power: 25mW. Firmware revision: 90651, v1.1. Countries in which Inovonics European products can be distributed: Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Greece, Hungary, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, United Kingdom. 8 Compliance Requirements 8.1 FCC Requirements for the EN1941XS The EN1941XS one-way serial data RF module has received a Limited Modular Grant, requiring Inovonics to retain control of the final installation to ensure compliance to FCC/IC regulations. The integrator is responsible to test the final installation to verify compliance to FCC/IC regulation for unintentional emissions. Prior to marketing the product, the integrator must complete and submit to Inovonics a compliance review form and documentation, and, if requested, a functional product sample for approval. If this is not possible, the integrator must perform the testing themselves and submit proof to Inovonics of compliance to Part 15 of the FCC Rules and Industry Canada RSS-210. At the end of this guide is an Inovonics compliance review form to be filled out by the integrator. The integrator is also responsible for properly labeling the product containing the oneway serial data RF module. Labels must be placed on the outside of the product, and must include a statement indicating that the product contains the module, along with the FCC and IC number. Example 1 Contains One-Way Serial RF Module FCC ID: HCQ3B6OT9OEM; IC ID: 2309A-OT9OEM (EN1941XS-IC) Example 2 Contains FCC ID: HCQ3B6OT9OEM; IC ID: 2309A-OT9OEM (EN1941XS-IC) 8.2 Television and Radio Interference This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 5.25.17 06288F Inovonics, 2017 - www.inovonics.com 3

Inovonics One-Way Serial RF Module Compliance Review Form Please provide the following information for review of final installation to ensure compliance with FCC/IC regulations: Required materials from integrator The following must also be attached for review with this form: A description of the final installation, with attached photographs, as necessary The unintentional radiator test report indicating compliance Integrator information First name: Phone number: Last name: Email address: Address: Declaration of conformity to Inovonics installation instructions: Submitted materials: Authorized signature: Submission date: Inovonics contact information Inovonics ATTN: Product Management 397 South Taylor Ave. Louisville, CO 80027 Phone: 303.939.9336 Toll-Free: 800.782.2709 Fax: 303.939.8977 productmanagers@inovonics.com 5.25.17 06288F Inovonics, 2017 - www.inovonics.com 4

Required materials from Inovonics The record of product sample review and test, as necessary Inovonics approval First name: Phone number: Last name: Email address: Approval status (pass, fail, samples required, compliance testing required, compliance test report required): Approval comments: Submitted materials: Returned materials: Authorized signature: Approval date: 5.25.17 06288F Inovonics, 2017 - www.inovonics.com 5