Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

Similar documents
Page: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK

Page: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6

Page: 1 of 44 EMC TEST REPORT. : Gembird Electronics Ltd. Room 1709, News Building, #2 Shennan Zhong Lu, Shenzhen, China

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EMC TEST REPORT. Page: 1 of 41. : Netion Electronic Co., Ltd. : Fanhu Industrial Park, Sanshui, Foshan, Guangdong, China. Equipment Under Test (EUT) :

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

1 - GENERAL INFORMATION SYSTEM TEST CONFIGURATION DISTURBANCE VOLTAGE AT THE MAINS TERMINALS RADIATED DISTURBANCES...

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

FCC PART MEASUREMENT AND TEST REPORT

FCC PART 15 B MEASUREMENT AND TEST REPORT

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

TEST REPORT... 1 CONTENT...

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

FCC PART 15 B MEASUREMENT AND TEST REPORT

Test Report GUANGDONG EAST POWER CO., LTD

2620 Modular Measurement and Control System

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

FCC Part 15B Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. FCC Part 15 Subpart B.

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

EMC TEST REPORT : EGO-PZ001, EGO-PZ002, EGO-PZ003, EGO-PZ004, EGO-PZ005, EGO-PZ006, EGO-PZ007, EGO-PZ008

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for

FCC PART 15, CLASS B MEASUREMENT AND TEST REPORT. NanJing JingZe Lighting Technology Co.,Ltd

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

FCC PART MEASUREMENT AND TEST REPORT FOR. Guangzhou Walkera Technology CO., LTD

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

EMC standards. Presented by: Karim Loukil & Kaïs Siala

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

EMC test report AU01+E04

SGS-CSTC Standards Technical Services. SGS-CSTC(Shanghai)Co.,Ltd EMC TEST REPORT SHEMO AV01-A2 LINCON AUTOMATION CO., LTD

FCC PART TEST REPORT. Weccan Industrial Limited

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017

ELECTRONICS TESTING CENTER(ETC), TAIWAN

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

EMC Measurement and Test Report. For. GlobTek, Inc. 186 Veterans Dr. Northvale, NJ USA. Power supply STR E. Damon Ma / Engineer

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

TABLE OF CONTENTS 1.GENERAL INFORMATION PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) TEST STANDARDS TEST METHODOLOGY...4

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

FCC PART 15 Subpart C EMI MEASUREMENT AND TEST REPORT

EMC Test Report. Report Number: M030826

EMISSION. EN : 2006 Clause 6.5 Pass. Harmonic Current EN : 2006+A1: 2009+A2: 2009 Class A Pass

FCC 47 CFR PART 15 SUBPART B TEST REPORT KST DIGITAL TECHNOLOGY LIMITED. Brushless Servo

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54

EMC TEST REPORT for Repel-it. REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

AS/NZS CISPR 14.1:2010 MEASUREMENT AND TEST REPORT

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

Compliance Engineering Ireland Ltd

1 SUMMARY OF STANDARDS AND RESULTS

EMC Test report for LED Panel Light Models , , , , ,

Report No.: 11A080304E-E Page 1 of 35. CE Test Report. (Declaration of Conformity) for. Electromagnetic Compatibility.

EMC TEST REPORT For Prokits Industries Co., Ltd.

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

EMC TEST REPORT. For MICRO-STAR INT'L CO.,LTD. USB Card Reader

2004/104/EC Measurement and Test Report

Declaration of Conformity.

EMC VERIFICATION SUMMARY Report No.: SZHH

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN

Radio Spectrum. RF output power ETSI EN V2.1.1: dBm Pass

EMC TEST REPORT. For Shenzhen Scotle Technology Ltd CNC ROUTER. Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

Report No.: 9A042401C1 Page 1 of 51. Test Report. EN 50155: 2007 (EMC, Characteristic, Environmental Test) Prepared for

FCC REPORT. Dongguan Hele Electronics Co., Ltd. J11, J12, J13, Q7, Q28, Q26, Q29

Shenzhen Huanxi Technology Co., Ltd. Smart Self-balancing Scooter

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU

1 Introduction Test Specification Environment Relevant standards Emissions Immunity...

Verification On Behalf of Shenzhen Leer Chuang Technology Co., Ltd.

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

EN 55022: 2006+A1: 2007 EN : 2007 EN 55024: 2010 EN : 2006+A2: 2009 EN : Measurement and Test Report.

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

Transcription:

Page: 1 of 20 EMC TEST REPORT Reference No. Applicant : WT05060412 : Gembird Electronics Ltd. Equipment Under Test (EUT) : Product Name : Cable Standards Model No : UAS111-M, UAS111, UAS112 : EN55022:1998+A2:2003 EN55024:1998+A2:2003 Date of Test : June 16, 2005 Test Engineer : Tiger Su Reviewed By : Test Result : PASS * * The sample detailed above has been tested to the requirements of Council Directives 89/336/EEC (as amended by Directives 92/31/EEC and 93/68/EEC). The test results have been reviewed against the Directives above and found to meet their essential requirements.

Page:2 of 20 1 Test Summary Test Test Requirement Test Method Class / Severity Result Mains Terminal Disturbance Voltage, 150kHz to 30MHz EN55022:1998+A2-2003 EN55022:1998+A2-2003 Class B N/A Radiation Emission, 30MHz to 1000MHz EN55022:1998+A2-2003 EN55022:1998+A2-2003 Class B PASS Harmonic Emission on AC, 100Hz to 2kHz EN 61000-3-2 : 2000 EN 61000-3-2 : 2000 Clause 7 of EN61000-3-2 N/A Flicker Emission on AC EN 61000-3-3 :1995 +A1:2001 EN 61000-3-3 :1995 +A1:2001 Clause 5 of EN61000-3-3 N/A ESD EN55024 : 1998+A2:2003 EN61000-4-2 :1995 + A1:2001 ±4 kv Contact ±8 kv Air PASS Radiated Immunity (80MHz to 1GHz) EN55024 : 1998+A2:2003 EN61000-4-3 : 2002 + A1:2002 3V/m, 80%, 1kHz, Amp. Mod. PASS Electrical Fast Transients (EFT) on AC and DC EN55024 : 1998+A2:2003 EN61000-4-4 :2004 AC DC ±1.0kV ±0.5kV N/A Surge Immunity on AC EN55024 : 1998+A2:2003 EN 61000-4-5 :1995 +A1:1996 ±1kV D.M. ±2kV C.M. N/A Injected Currents on AC & DC, 150kHz to 80MHz EN55024 : 1998+A2:2003 EN 61000-4-6 :1996 +A1:2001 3Vrms(emf), 80%, 1kHz Amp. Mod. N/A Power-frequency magnetic field EN55024 : 1998+A2:2003 EN 61000-4-8 :1993 +A1:2001 3A/m N/A Voltage Dips and Interruptions on AC EN55024 : 1998+A2:2003 EN61000-4-11:1994 +A1:2001 >95 % U T * for 0.5per >95 % U T * for 250per 70 % U T * for 25per N/A Remark: The EUT was within the minimum performance (e.g., the EUT made disturbance sound) level set by the applicant. A.M. Amplitude Modulation. P.M. Pulse Modulation. D.M. Differential Mode * U T is the nominal supply voltage

Page:3 of 20 2 Contents 1 TEST SUMMARY...2 2 CONTENTS...3 3 GENERAL INFORMATION...4 3.1 CLIENT INFORMATION...4 3.2 DETAILS OF E.U.T....4 3.3 DESCRIPTION OF SUPPORT UNITS...4 3.4 STANDARDS APPLICABLE FOR TESTING...4 3.5 TEST FACILITY...6 3.6 TEST LOCATION...6 4 EQUIPMENT USED DURING TEST...7 5 EMISSION TEST RESULTS...9 5.1 RADIATION EMISSION DATA...9 5.1.1 Measurement Uncertainty...9 5.1.2 EUT Setup...9 5.1.3 Spectrum Analyzer Setup...9 5.1.4 Test procedure...10 5.1.5 Corrected Amplitude & Margin Calculation...10 5.1.6 Summary of Test Results...10 5.1.7 Radiated Emissions Test Data...11 5.1.8 Radiated Emissions Test Data...12 5.1.9 Photographs Radiation Emission Test Setup...12 6 IMMUNITY TEST RESULTS...13 6.1 PERFORMANCE CRITERIA DESCRIPTION...13 6.2 ESD...13 6.2.1 E.U.T. Operation...13 6.2.2 Direct Application Test Results...14 6.2.3 Indirect Application Test Results...14 6.2.4 Photographs - ESD Test Setup...15 6.3 RADIATED IMMUNITY...16 6.3.1 E.U.T. Operation...16 6.3.2 Test Results...16 6.3.3 Photographs - Radiated Immunity Test Setup For X-Direction...17 7 PHOTOGRAPHS - CONSTRUCTIONAL DETAILS...18 7.1 EUT APPEARANCE VIEW (1)...18 7.2 EUT APPEARANCE VIEW(2)...18 7.3 EUT APPEARANCE VIEW (3)...19 7.4 PCB FRONT VIEW(1)...20 7.5 PCB BACK VIEW(2)...20 Page

Page:4 of 20 3 General Information 3.1 Client Information Applicant: Gembird Electronics Ltd. Address of Applicant: Product Name: Model No.: Room 1709, News Building, #2 Shennan Zhong Lu, Shenzhen, China Cable UAS111-M, UAS111, UAS112 3.2 Details of E.U.T. Power Supply: USB Signal 3.3 Description of Support Units The EUT has been tested as an independent unit. 3.4 Standards Applicable for Testing The customer requested EMC tests for a Cable. The standards used were EN55022 Class B for emissions & EN55024 for immunity. Table 1 : Tests Carried Out Under EN55022:1998+A2:2003 Standard Status EN55022: 1998+A2:2003 Radiation Emission, 30MHz to 1000MHz EN55022: 1998+A2:2003 Mains Terminal Disturbance Voltage,150KHz to 30MHz

Page:5 of 20 Table 2 : Tests Carried Out Under EN 61000-3-2: 2000 & EN61000-3-3: 1995 + A1: 2001 EN61000-3-2: 2000 EN61000-3-3: 1995 + A1: 2001 Flicker Emissions on AC Indicates that the test is applicable Indicates that the test is not applicable Table 3 : Tests Carried Out Under EN55024:1998+A2: 2003 Standard Status EN61000-4-2:1995 + A2:2001 Electro-static discharge EN61000-4-3:2002 Radio frequency EM fields (80MHz to 1GHz) EN61000-4-4:2004 Fast transients EN61000-4-5:1995 +A1:2001 Surges EN61000-4-6:1996+A1:2001 Radio frequency continuous conducted (150kHz to 80MHz) EN61000-4-8:1993+A1:2001 Power-frequency magnetic field (50Hz) EN61000-4-11:1994+A1:2001 Voltage dips & interruptions Indicates that the test is applicable Indicates that the test is not applicable

Page:6 of 20 3.5 Test Facility The test facility is recognized, certified, or accredited by the following organizations: FCC Registration No.: 662850 Shenzhen Huatongwei International Inspection Co., Ltd, EMC Laboratory has been registered and fully described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained in our files. Registration 662850, November 17, 2003.. 3.6 Test Location All Emissions testswere performed at:- Shenzhen Huatongwei International Inspection Co., Ltd. at Keji S,12th,Road, Hi-tech Industrial Park, Shenzhen, Guangdong, China..

Page:7 of 20 4 Equipment Used during Test Conducted Emission Test Item Test Equipment Manufacturer Model No. Serial No. Cal. Date Due date 1 CE Variac GZ Debao Factory TS/DGC 2-5 N/A N/A N/A 2 LISN SCHAFFNER CHASE MNZ050D11 1421 11-11-2004 10-11-2005 3 Shielding Room Frankonia 12 x 4 x 4 m 3 N/A N/A N/A 4 EMI Receiver ROHDE & SCHWARZ ESCS30 100086 11-11-2004 10-11-2005 5 Coaxial Cable HTW 2m N/A 11-11-2004 10-11-2005 Radiated Emission Test Item Test Equipment Manufacturer Model No. Serial No. Cal. Date Due date 1 3m Semi- Anechoic Chamber 2 EMI Test Receiver 3 EMI Test Software Frankonia N/A N/A 11-11-2004 10-11-2005 ROHDE & SCHWARZ ROHDE & SCHWARZ ESCS30 100085 11-11-2004 10-11-2005 ES-K1 N/A N/A N/A 4 Coaxial cable HTW N/A N/A 11-11-2004 10-11-2005 5 Bilog Attenna SCHAFFNER CHASE CBL6143 N/A 11-11-2004 10-11-2005 Radiated Power Item Test Equipment Manufacturer Model No. Series No. Cal. Date Due date 1. Shielding Room Frankonia 12 x 4 x 4 m 3 EMC0103 N/A N/A 1. Absorbing Clamp Schwarzbeck MDS 20 901997 11-11-2004 10-11-2005 2. EMI Test Receiver Rohde & Schwarz ESCS30 100086 11-11-2004 10-11-2005 3. 7m Coaxial Cable HTW 7m EMC0303 11-11-2004 10-11-2005 ESD Item Test Equipment Manufacturer Model No. Series No. Cal. Date Due date 1 ESD Tester EM Test N/A 302105 11-11-2004 10-11-2005 Radiated Immunity Item Test Equipment Manufacturer Model No. Series No. Cal. Date Due date GTEM Lindgreen-Rayproof 1750 EMC0401 11-11-2004 10-11-2005 1. Signal Generator Rohde & Schwarz SMY01 825675/018 11-11-2004 10-11-2005 2. Function Generator Philips PM5134 LO-263813 11-11-2004 10-11-2005 3. Amplifier 0.08-1GHz SCHAFFNER CBA9413A 4004 11-11-2004 10-11-2005 4. Power Meter Rohde & Schwarz NRVS 825770/074 11-11-2004 10-11-2005 5. Power Sensor Rohde & Schwarz NRV-Z5 825802/013 11-11-2004 10-11-2005

Page:8 of 20 Dual Directional Coupler WERLATONE INC. C1795 6634 11-11-2004 10-11-2005 6. Electric Field Probe Wandel & Goltermann EMC-20 M-0063 11-11-2004 10-11-2005 Ite m Conducted Immunity Test Test Equipment Manufacturer Model No. Series No. Cal. Date Due date 1 Signal Generator ROHDE & SCHWARZ SMY01 825675/016 11-11-2004 10-11-2005 2 Amplifier 0.15-230MHz OPHIRRF GRF5048 1003 11-11-2004 10-11-2005 3 Power Meter ROHDE & SCHWARZ NRVS 825770/079 11-11-2004 10-11-2005 4 Power Sensor ROHDE & SCHWARZ NRV-Z5 825802/012 11-11-2004 10-11-2005 5 Dual Directional Coupler WERLATONE INC. C1795 6635 11-11-2004 10-11-2005 6 Oscilloscope Type 485 TEKTRONIX 485 B144408 N/A N/A 7 CDN M2 SCHAFFNER CHASE CDN-M2-16 9863 11-11-2004 10-11-2005 8 Immunity S/W Ver 4.31 SCHAFFNER CHASE CIS9942 WHHPKB N/A N/A Common Used Equipment Item Test Equipment Manufacturer Model No. Series No. Cal. Date Due date 1 Temperature, Humidity Barometer & OREGON SCIENTIFIC BA-888 2 DMM FLUKE 73 EMC0001 to EMC0004 70681569 or 70671122 11-11-2004 10-11-2005 11-11-2004 10-11-2005 3 PC DELL D4600 N/A N/A N/A

Page:9 of 20 5 Emission Test Results 5.1 Radiation Emission Data Test Requirement: EN 55022 Class B Test Method: EN 55022 Class B Test Date: June 16, 2005 Frequency Range: 30MHz to 1000MHz Class/Severity: Table 1 of EN55022 Detector: Peak for pre-scan (120kHz Resolution Bandwidth) Quasi-Peak & Average if maximised peak within 6dB of Average Limit 5.1.1 Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in the field of EMC. The factors contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency interpolation, measurement distance variation, site imperfections, mismatch (average), and system repeatability. Based on NIS 81, The Treatment of Uncertainty in EMC Measurements, the best estimate of the uncertainty of a radiation emissions measurement at HTW is +4.0 db. 5.1.2 EUT Setup The radiated emission tests were performed in the 3m Semi- Anechoic Chamber test site, using the setup accordance with the CISPR16-1, The specification used in this report was the EN55022 Class B limits. The EUT was placed on the test table in on mode connected with the 9 PIN Modem. 5.1.3 Spectrum Analyzer Setup According to EN55022 Class B Rules, the system was tested to 1000 MHz. Start Frequency...30 MHz Stop Frequency...1000 MHz Sweep Speed Auto IF Bandwidth...1 MHz Video Bandwidth...1 MHz Quasi-Peak Adapter Bandwidth...120 khz Quasi-Peak Adapter Mode...Normal

Page:10 of 20 Resolution Bandwidth...1MHz 5.1.4 Test procedure For the radiated emissions test, since the EUT does not have a power source, there was no connection to AC outlets. Maximizing procedure was performed on the six (6) highest emissions to ensure EUT is compliant with all installation combinations. All data was recorded in the peak detection mode. Quasi-peak readings was performed only when an emission was found to be marginal (within -4 dbµv of specification limits), and are distinguished with a "Qp" in the data table. The EUT was under normal mode during the final qualification test and the configuration was used to represent the worst case results. 5.1.5 Corrected Amplitude & Margin Calculation The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Factor, and subtracting the Amplifier Gain from the Amplitude reading. The basic equation is as follows: Corr. Ampl. = Indicated Reading + Antenna Factor + Cable Factor - Amplifier Gain The Margin column of the following data tables indicates the degree of compliance with the applicable limit. For example, a margin of -7dBµV means the emission is 7dBµV below the maximum limit for Class B. The equation for margin calculation is as follows: Margin = Corr. Ampl. Class B Limit 5.1.6 Summary of Test Results According to the data in section 5.1.7, the EUT complied with the EN55022 Class B standards, and had the worst margin of: -3.0 dbµv at 92.204 MHz in the vertical polarization, 30 MHz to 1000 MHz, 3 meter.

Page:11 of 20 5.1.7 Radiated Emissions Test Data Vertical: 80 Level [db /m] 70 60 50 40 30 x x x x x 20 10 0 30M 50M 70M 100M 200M 300M 500M 700M 1G Frequency [Hz] x MES WALT0420415_red PK MES WALT0420415_pre PK LIM EN 55022B F QP Field Strength QP Limit Horizontal: 80 Level [db /m] 70 60 50 40 30 x x 20 10 0 30M 50M 70M 100M 200M 300M 500M 700M 1G Frequency [Hz] x MES WALT0420414_red PK MES WALT0420414_pre PK LIM EN 55022B F QP Field Strength QP Limit

Page:12 of 20 5.1.8 Radiated Emissions Test Data Frequency (MHz) Antenna Polarization Emission Level (dbuv/m) EN55022 Class B Limit (dbuv/m) Margin (db) Antenna Height (m) Turntable Angle ( ) 92.204409 Vertical 38.86 40.0 3.00 1.00 85 109.699399 Vertical 35.86 40.0 4.14 1.00 68 183.567134 Vertical 31.43 40.0 8.57 1.00 57 203.006012 Vertical 34.11 40.0 5.89 1.00 155 220.501002 Vertical 36.98 40.0 3.02 1.00 20 92.204409 Horizontal 33.33 40.0 6.67 1.00 301 733.687375 Horizontal 37.09 47.0 9.91 1.00 112 5.1.9 Photographs Radiation Emission Test Setup

Page:13 of 20 6 Immunity Test Results 6.1 Performance Criteria Description Criterion A: The apparatus shall continue to operate as intended. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. Criterion B: The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. Criterion C: Temporary loss of function is allowed, provided the function is self recoverable or can be restored by the operation of the controls. For further details, please refer to of EN55024. 6.2 ESD Test Requirement: EN55024 Test Method: EN61000-4-2 Test Date: June 16, 2005 Discharge Impedance: 330 Ω / 150 pf Discharge Voltage: Air Discharge: 8 kv Contact Discharge: 4 kv HCP & VCP: 4 kv Polarity: Positive & Negative Number of Discharge: Minimum 10 times at each test point Discharge Mode: Single Discharge Discharge Period: 1 second minimum 6.2.1 E.U.T. Operation Operating Environment: Temperature : 24.0 C Humidity : 52 % RH Barometric Pressure : 1012 mbar EUT Operation: The EUT was placed on the test table in on mode connect with the 9 PIN Modem.

Page:14 of 20 6.2.2 Direct Application Test Results Observations : Test points : 1. All Exposed Surface & Seams; 2. All matellic part Direct Application Test Results Discharge Level (kv) Polarity (+/-) Test Point Contact Discharge Air Discharge 8 +/- 1 N/A A 4 +/- 2 A N/A Results A: No degradation in the performance of the E.U.T. was observed. N/A: Not applicable. 6.2.3 Indirect Application Test Results Observations : Test points : 1. All sides. Indirect Application Test Results Discharge Level (kv) Polarity (+/-) Test Point Horizontal Coupling Vertical Coupling 4 +/- 1 A A Results A: No degradation in the performance of the E.U.T. was observed.

Page:15 of 20 6.2.4 Photographs - ESD Test Setup

Page:16 of 20 6.3 Radiated Immunity Test Requirement: EN55024 Test Method: EN61000-4-3 Frequency Range: 80MHz 1GHz Face Under Test: Three Mutually Orthogonal Faces Severity: 3V/m, 1kHz, 80% Amp. Mod. from 80MHz to 1GHz Test Date: June 16, 2005 6.3.1 E.U.T. Operation Operating Environment: Temperature: 24.0 C Humidity: 52 % RH Barometric Pressure: 1012 mbar EUT Operation: The EUT was placed on the test table in on mode connect with the 9 PIN Modem. 6.3.2 Test Results Frequency Level Modulation EUT Face Result / Observations 80MHz- 1GHz 3V/m 1kHz, 80%, Amp. Mod. Remarks: AM : Amplitude Modulation. PM : Pulse Modulation. X : EUT as per photograph in section 6.3.3 of this report. Y : As X, but rotate EUT by 90 clockwise. Z : As Y, but rotate EUT by 90 vertically. X Y Z During test, noise can be heard. After test EUT recovers to normal (B). Results B : During test, noise can be heard. This was within the minimum performance criteria set by the applicant. Please refer to section 6.1 of this report for further details.

Page:17 of 20 6.3.3 Photographs - Radiated Immunity Test Setup For X-Direction

Page:18 of 20 7 Photographs - Constructional Details 7.1 EUT Appearance View (1) 7.2 EUT Appearance View(2)

Page:19 of 20 7.3 EUT Appearance View (3)

Page:20 of 20 7.4 PCB Front View(1) 7.5 PCB Back View(2)