FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

Similar documents
IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

LOAD AWG Solid CU Wire Only LINE NEUT FSP-211. High/Low PIR Occupancy Sensor 230 VAC, 50 Hz 1200W max ballast 5E4

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

OCCUPANCY SENSOR REMOTE USER GUIDE

Installing the FSP-211 Sensor in Light Fixture

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING

High/Low Bay Passive Infrared Occupancy Sensor

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH

Single-zone Daylighting Control Sequences of Operation. Topic: DLM Operation with LMLS-400 Photosensor, v2.xx Issue: # TB185 Date: March 10, 2012

CONTINUOUS DIMMING MOTION SENSOR & COMPATIBLE REMOTE PROGRAMMER MSITXLRD509 & RMTITXSRP280

SELECTABLE MODE HIGH/LOW/OFF PIR FIXTURE INTEGRATED INDOOR/OUTDOOR MOTION/PHOTO SENSOR

2 Pendant Adjustment. Pendant Slider Plate. 3/4 (19mm) IP, (29mm) O.D. Knockouts. 1/2 (13mm) IP, (22mm) O.D. Knockout

O ccupancy and Light Level Sensor L ow Vo l tage Ceiling Fixture Mount

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

v3 360 Passive Infrared Line Voltage Occupancy Sensor

Wireless Ceiling Motion Sensor for Occupancy / Vacancy Detection with integrated diagnostic tools INSTALLATION GUIDE

Data sheet. Function description. Benefits

EBDHS-MB-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

Wireless Ceiling Mount Sensor for Occupancy / Vacancy Detection INSTALLATION GUIDE

EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

with Light Level, Isolated Relay and Manual On features

This document is intended for Lighting Control Systems professionals

TekLink TL100 with Passive Infrared Sensing System Overview

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Installation Instructions

Installation Instructions

Fixture Built-in Sensor Daylight Harvest Version

Technical Application Guide


CX-100. Installation Instructions. PIR Occupancy Sensor SPECIFICATIONS

EBDHS-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

Product Specifications

No: /17 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

TS-WS-07 Wireless Indoor/Outdoor 8-Channel Thermo-Hygrometer with Jumbo Display User Manual

Eco-$mart, Inc. TOLL FREE:(888) FAX:(941)

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE LED SURFACE AMBIENT LUMINAIRE FACTORY SETTINGS. Configuration Value

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR

MANUFACTURER MODEL NUMBER LUMENS COLOR TEMPERATURE OPTIONS 3100LM 4500LM 5800LM

Wireless Ceiling Mount Sensor

WATTSTOPPER OEM SENSOR GUIDE INTEGRATED LIGHTING CONTROLS. designed to be better.

Installation Instructions

ASSEMBLY AND INSTALLATION INSTRUCTIONS

RPT LEDCF 4000K LEDCF LOW-PROFILE LED CANOPY LUMINAIRE PART NUMBER BUILDER

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

EBDSM-PRM Product Guide

Wireless Occupancy Sensor User Guide

No: /17 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

Radio Powr SavrT Occupancy / Vacancy Sensor

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.

Sensors. EasyAir. office sensor standalone SNS100. Design-in Guide. Single, compact, cost-effective luminaire control. Philips EasyAir office sensors

ZoneLite setup remote handset. Daylight Linking & Daylight Dependency control

LCC1653, LCC1656, LRI1653 Datasheet ActiLume DALI System

DIGITAL DIRECTION SENSING MOTION DETECTOR MANUAL

EasyAir Office sensor advanced grouping SNS200

LEDCF LOW-PROFILE LED CANOPY LUMINAIRE

Installation Instructions

Radio Powr SavrTM Wireless Occupancy / Vacancy Ceiling Sensor

RF Wireless Version On/off Control

Owner s Manual BL

ETC Installation Guide

Human Centric Lighting System

Sense Command Control. Third Eye. Energy Saving Sensors Save Energy Today for a Better Tomorrow

FAG PRESTO DX. FAG PRESTO-DX preliminary User Manual. FAG GRAPHIC SYSTEMS S.A. 3, rue de la Vigie CH-1003 Lausanne Switzerland

Philips Ledalite Phone: Fax: Web: Programming Guide Version 2.0

LRF20CR2BPWH Ceiling MNT Wireless Occ Sensor

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Occupancy Sensors for High-Bay Applications

EasyAir Office sensor advanced grouping SNS200


RF ceiling microwave presence detector DALI / DSI

OCC Motion Sensor. Guide: how to program and use

No: /17 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

Dakota Alert. WMT-3000 Wireless Transmitter. Owner s Manual

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Wireless occupancy/vacancy sensor

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

ActiLume 1-10V. OEM application guide

HBL Series High Bay LED


Catalog Number LSBT. Example: LSBT6C8T5WD1-BZ QMB. Optics. Type II Type III Type IV Type IV Automotive Type V Medium Type V Wide T2 T3 T4 T4A T5M T5W

VIENTO LARGE SITE & AREA LED LUMINAIRE

Dual Technology Wall Mount Occupancy Sensor

KNX presence detectors for ceiling flush mount EK-DD2-TP, EK-DE2-TP

Sensors. Datasheet. EasyAir SNS200

PAPI Infrared Operation Overview

Sensors. EasySense. SNS200 Advanced Grouping. Design-in Guide. Single, compact, cost-effective luminaire control

Sensors. Datasheet. EasyAir SNS200

Infrared Wall Mount Occupancy Sensor

EasyAir office sensor standalone SNS100

Qflash Pilot QF9. Shoe Mount Wireless Radio Commander for Qflash 5d-R and TRIO. F tested to comply with FCC standards. Operating Instructions

Dual Technology Ceiling Mount Sensor

High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires

Table Of Contents 2-4. EasySense Control. FLT - Flat Lens Troffer. FLTR - Flat Lens Troffer Retrofit. VOLA - Volumetric Troffer

Wireless CO 2. + TRH Sensor. Installation Guide. Version 1

GE Lighting. control. Aware Occupancy and Photo Sensors

Connect + compatible

Sensors. EasySense. Fixture-Mount for Basic Grouping

Sensors. EasySense. Fixture-Mount for EvoKit

LITECOM. Special luminaires SEQUENCE infinity

Radio controlled home automation

Transcription:

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR CAUTIONS INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. To avoid the possibility of electrical shock, turn off power supply before installation or servicing. 2. Product must be installed in accordance with NEC or your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician. 3. All electrical connections have been made at the factory. 4. The sensor is designed for mounting heights between 8 ft. to 40 ft., see figure 1, 2 and 3 for product specific coverage pattern. The handheld remote unit has a range of only 40ft. 5. When mounting heights are above 30ft., the sensor generally only detects large objects such as forklift trucks. 6. When sensor lens assembly is removed the exposed sensor body is sensitive to electrostatic discharge. Take the necessary steps to avoid possible damage to the sensor. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE PIR Sensor Light Sensor Motion Indicator Red LED IR Transmitter IR Receiver F1 SENSOR DESCRIPTION The FSP-211 is a motion sensor that dims lighting from high to low based on movement. This slim, low-profile sensor is designed for installation inside the bottom of a light fixture body. The PIR lens module connects to the FSP-211 through a 1.30 diameter hole in the bottom of the fixture. The sensors use passive infrared (PIR) sensing technology that reacts to changes in infrared energy (moving body heat) within the coverage area. Once the sensor stops detecting movement and the time delay elapses, lights will go from high to low mode and eventually to an OFF position if it is desired. Sensors must directly see motion of a person or moving object to detect them, so careful consideration must be given to sensor luminaire placement and lens selection. Avoid placing the sensor where obstructions may block the sensor s line of sight. See Figure 1. The FSP-211 operates at 120V/230V/240V/277V, no power pack is required. It is designed to be installed in indoor and outdoor environments. Once powering the device up, the FSP-211 will use factory default parameters to operate. If adjustments are needed, programming tool must be used.

F2 FSP-L2 Low Density/Wide Range Lens Coverage Top View Coverage Side View INSTALLATION F3 F4 FSP-L3 High Density/Reduced Range Lens FSP-L4 40 Foot High Bay Lens The FSP-211 unit comes pre-wired and installed in the fixture. COVERAGE PATTERN The density and the range of the coverage pattern is determined by the type of lens and mounting height. For standard lenses and patterns for: FSP-L2: 360 Coverage - Provides a 44 diameter coverage area when mounted at a height of 8. See FIGURE 2. For FSP-L3: 360 Coverage - has a high density lens that covers a 40 diameter area at a height of 20. See FIGURE 3. For FSP-L4: 360 Coverage - is designed for mounting at heights between 30 to 40. Its coverage area can be up to 60 in diameter when mounted at 40 ( EDGE, Area Canopy and Security products only). See FIGURE 4.

max. height of 40 F5 Distance may vary depending on the lighting environment F6 FSP-211 COMMISIONING The commissioning process establishes the appropriate parameters for the FSP-211 operation. This is done through the use of the commissioning tool. If no commissioning steps are taken, the sensor will use its default parameter values. For default values see Navigation of Programming Tool section. USING THE PROGRAMMING TOOL The Wireless IR Programming Tool is a handheld tool for setup and testing of FSP-211. It provides wireless access to the FSP-211 sensors for setup and parameter changes. The programming tool display shows menus and prompts to lead you through each process. The navigation pad provides a familiar way to navigate through the customization fields. See Figure 5. Within a certain mounting height of the sensor, 40 or less, the programming tool allows modification of the system without requiring ladders or tools; simply with a touch of a few buttons. OPERATION The programming tool IR transceiver allows bi-directional communication between the FSP-211 and the programming tool. Simple menu screens let you see the current status of the system and make changes. It can change FSP-211 sensor parameters such as high/low mode, sensitivity, time delay, cut off and more. With the programming tool you can also establish and store FSP-211 parameter profiles. BATTERIES The programming tool operates on three standard 1.5V AAA Alkaline batteries or three rechargeable AAA NiMH batteries. The battery status displays in the upper right corner of the display. Three bars next to BAT= indicates a full battery charge. A warning appears on the display when the battery level falls below a minimum acceptable level. To conserve battery power, the programming tool automatically shuts off 10 minutes after the last key press. NAVIGATION You navigate from one field to another using (up) or (down) arrow keys. The active field is indicated by flashing (alternates between yellow text on black background and black text on yellow background. Once active, use the Select button to move to a menu or function within the active field. Value fields are used to adjust parameter settings. They are shown in less-than/ greater-than symbols: <value>. Once active, change them using(left) and(right) arrow keys. In general the up key increments and the down key decrements a value. Selections wrap-around if you continue to press the key beyond maximum or minimum values. Moving away from the value field overwrites the original value. The Home button takes you to the main menu. The Back button can be thought of as an undo function. It takes you back one screen. Changes that were in process prior to pressing the key are lost. IR COMMUNICATION IR communication can be affected by the mounting height of the sensor and high ambient lighting such as direct daylight of electric light such as floodlights, and some halogen, fluorescent lamps, LED s. When trying to communicate with the FSP-211, be sure to be positioned under the sensor without any obstructions. Every time the programming tool establishes communication with the FSP-211, the controlled load will cycle. See Figure 6. If communication is not successful, (if possible) move closer to the sensor. If still not successful, there may be too much IR interference from other sources. Programing the unit at night when there is no daylight available may be the only way to communicate with the sensor

NAVIGATION OF PROGRAMMING TOOL HOME MENU The Home (or Main) menu displays after the power-up process completes. It contains information on the battery status and four menu choices. Press the up or down buttons to highlight the desired sensor then press Select. NEW SETTINGS New Settings allow you to select the different sensor parameters such as: High/Low Mode, Time Delay, Cut Off, Sensitivity, Setpoint and Ramp/Fade rates. HIGH MODE When the sensor detects motion the dimming control output ramps up to the selected HIGH light level (default is 10V). Range: 0 V to 10 V Increments: 0.2 V LOW MODE After the sensor stops detecting motion and the time delay expires the dimming control output fades down to the selected LOW light level (default is 1V). Range: OFF, 0 V to 9.8 V Increments: 0.2 V TIME DELAY The time period that must elapse after the last time the sensor detects motion for the lights to fade to LOW mode (default is 5 min). Range: 30 sec, 5 min to 30 min Increments: 1 min CUT OFF The time period that must elapse after the lights fade to Low Mode and the sensor detects no motion for the lights to turn OFF (default is 1 hour). Range: None (No cut off, lights will stay in low mode) 1 min to 59 min, 1 hr to 5 hr (press and hold should cause to move faster through the increments) Increments: 1 min or 1 hr SENSITIVITY The response of the PIR detector to motion within the sensor s coverage area (default is max). Range and Sequence: On-Fix, Off-Fix, Low, Med, Max (On-Fix: relay closed, occupancy detection disabled; Off-Fix, relay open, occupancy detection disabled. SETPOINT The selectable ambient light level threshold that will hold the lights off or at LOW level when the sensor detects motion (default is 4 fc). Range: Auto, None, 1 fc to 250 fc Increments: 1 fc (press and hold should cause to move faster thru the increments) Sequence: None, 1 fc to 250 fc (None will disable the setpoint feature) The Auto option invokes an automatic calibration procedure to establish an appropriate setpoint based upon the contribution of the electric light. As part of this procedure, the controlled load is turned on for two minutes to warm up the lamp, and then it is switched off and on eight times, terminating in an off state. After this process, a new setpoint value is automatically calculated. NEXT To view more settings go to NEXT and press the Select button. RAMP UP Time period for light level to increase from LOW to HIGH (default is none; lights switch instantly). Range: None, 1 sec to 60 sec Increments: 1 sec FADE DOWN Time period for light level to decrease from HIGH to LOW (default is none; lights switch instantly). Range: None, 1 sec to 60 sec Increments: 1 sec PRIOR To go back to previous settings go to PRIOR and press the Select button. SAVE To be able to Save these parameters as one of the profiles go to SAVE and press the Select button. SEND To be able to program the FSP-211 with the selected parameters go to SEND and press the Select button. The controlled load should cycle once the sensor is programmed. CURRENT SETTINGS Current Settings allow you to recall the parameters for a specific sensor. These are read only parameters. VIEW CURRENT SETTINGS Text for viewing the current settings. Press Select to view more settings. To go back to previous settings go to PRIOR and press the Select button. LIGHT LEVEL Present light level at the FSP-211. The light level reading can be used as a reference for setpoint adjustments. SAVE To be able to Save these parameters as one of the profiles go to SAVE and press the Select button. DONE To be able to go to the FSP-211 Home screen go to DONE and press the Select button. TEST MODE Test Mode shortens timeouts for High/Low and Cut Off, to allow quick verification. Test Mode cancels automatically after 5 minutes. ENABLE/DISABLE Test Mode has been enabled. RECALL PROFILES Recall Profiles allow you to select the saved parameter profiles. This feature is used when programming multiple FSP-211 s with the same parameters. RECALL PARAMETERS Selecting a specific profile allow you to also change the parameters such as: High/Low Mode, Time Delay, Cut Off, Sensitivity, Setpoint and Ramp/Fade rates. DEFAULT PARAMETER VALUES HIGH MODE: LOW MODE: TIME DELAY: CUT OFF: SENSITIVITY: SETPOINT: RAMP UP: FADE DOWN: 10V 1V 5 minutes 1 hour Max 4 fc none; lights switch instantly none; lights switch instantly

TROUBLESHOOTING NO RESPONSE SCREEN APPEARS: Make sure that the sensor is not obstructed. Move closer to the sensor. The angle may be too high, move closer so that you are directly underneath the sensor. If still not successful, there may be too much IR interference from other sources. Programming the unit at night when there is no daylight available may be the only way to communicate with the sensor. LIGHTS WILL NOT GO TO HIGH MODE: Check all wire connections and verify the load and the ground wires are tightly secured. Make sure that the sensor is not obstructed. Check light level parameter, to find out the amount of light that the sensor is detecting. Cover the sensor lens to simulate darkness in the room. If the lights come ON, the setpoint needs to be adjusted. If set for minimum, more than 1 fc at the sensor of ambient light will cause the lights to be held OFF. See the new settings section for instructions. If lights still do not turn ON, call 800.236.6800 for technical support. LIGHTS WILL NOT TURN OFF: Cut Off time may be set to None. Ensure that the Cut Off is set to the desired time and that there is no movement within the sensor s view for that time period when the lights are in Low Mode. To quickly test the unit operation, enable test mode and move out of the sensor s view. Lights should go to low mode after 5 seconds and the OFF (if cut off is enabled) after 10 sec. If lights still do not turn OFF, call 800.236.6800 for technical support. OPERATION DURING POWER-UP During the sensor warm-up period, which can last up to a minute after initial power-up (or after a lengthy power outage), the load will remain ON until the selected time delay expires. LIGHTS WILL NOT GO INTO LOW MODE: The time delay can be set from a minimum of 30 seconds to a maximum of 5 to 30 minutes range. Ensure that the time delay is set to the desired delay and that there is no movement within the sensor s view for that time period. To quickly test the unit operation, enable test mode and move out of the sensor s view. Lights should go to low mode after 5 seconds. If lights still do not go into Low Mode, call 800.236.6800 for technical support.