DS2000UBLA-10V. Features. Applications: 20 ppm linearity. MPS for particles accelerators. 15 ppm offset. Gradient amplifiers for MRI devices

Similar documents
DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DS400ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1.5 ppm. MPS for particles accelerators

DL2000ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

DM1200ID. Specification highlights Symbol Unit Min Typ Max. Applications: Features. Power measurement and power analysis

DQ600ID. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 1 ppm. MPS for particles accelerators

DS200ID-CD100. Specification highlights Symbol Unit Min Typ Max. Features. Applications: Linearity error maximum 2 ppm. MPS for particles accelerators

DS10000ULFS-10V/10kA

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

High Performance Current Transducer ITL 900-T = A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I PM. Current Transducer ITZ 5000-SB FLEX ULTRASTAB = 5000 A

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Ref: HO 50-S/SP33, HO 100-S/SP33, HO 150-S/SP33, HO 200-S/SP33, HO 250-S/SP33

Current Transducer CTSR 1-P = 1A

DSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

HO 50-S/SP30, HO 100-S/SP30, HO 150-S/SP30, HO 200-S/SP30, HO 250-S/SP30 and HO 200-S/SP31

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

I PN. Ref: HO 50-S, HO 100-S, HO 150-S, HO 200-S, HO 240-S, HO 250-S

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Ref: HLSR 10-SM/SP33, HLSR 20-SM/SP33, HLSR 32-SM/SP33, HLSR 40-P/SP33, HLSR 50-SM/SP33

DSSIU-6-1U-V. Features VOM:

Ref: HLSR 10-P/SP3, HLSR 20-P/SP3, HLSR 40-P/SP3, HLSR 50-P/SP3

For the electronic measurement of current: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

Ref: HLSR 10-SM, HLSR 16-SM, HLSR 20-SM, HLSR 32-SM, HLSR 40-SM, HLSR 50-SM

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary circuit and the secondary circuit.

I P. /dt. di p V S+ Applications. Standards. 1) IEC ed1.0: 2007; IEC : ed1.0: 2012

AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

ULTRASTAB IHF Precision Current Transducer

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

ULTRASTAB I U Precision

Sensors & Accessories

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S02

Voltage transducer DVL 50

World-Class Accuracy & Measurement Range (40 Conventional Models)

Current transducer FHS 40-P/SP600

AUTOMOTIVE CURRENT TRANSDUCER HAH3DR 700-S00

= 600 V. Voltage transducer DVM 600 V PN

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

HC2F100-SN CLIPS AUTOMOTIVE CURRENT TRANSDUCER HC2F100-SN CLIPS. Datasheet

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER HC6F600-S

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DRW 300-S

AUTOMOTIVE CURRENT TRANSDUCER HC6F700-S

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Feed back element in high performance gradient amplifiers Feed back element in precision current regulated power supplies

Unipolar voltage - Current output 4-20 ma Ref: DVL 50-UI, DVL 150-UI, DVL 250-UI, DVL 500-UI, DVL 750-UI, DVL 1000-UI, DVL 1500-UI

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

V P N. Voltage transducer DVM 4200 = 4200 V

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 800-S03/SP2

Current transducer FHS 40-P/SP600

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

SPECIFICATION Item No.: T60404-P4640-X100

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH3DR 1100-S07

AUTOMOTIVE CURRENT SENSOR HC6H500-S. Datasheet

AUTOMOTIVE CURRENT SENSOR HC6H300-S

AUTOMOTIVE CURRENT TRANSDUCER HAH1DR 300-S

DC Current Transducers CT-200 CT-300 CT-400 User s Manual All Rights Reserved CAEN ELS d.o.o. Rev. 1.0 November 2014

Residual Current Monitoring Unit RCMU101SN-4P16

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1DR 200-S

= 1000 V. Voltage transducer DVC 1000-P V P N

Technical catalog. Current sensors Voltage sensors. Contact John G Peck Ltd - jgpl.com

SPECIFICATION Item no.: T60404-N4646-X764

imc CANSAS-L-HCI8. High isolated module for the capture of temperature, voltage, current (20 ma) and resistance

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

AUTOMOTIVE CURRENT TRANSDUCER HC6H1000-S

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

V P N. Voltage transducer DVL 1000 = 1000 V

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic isolation between the primary and the secondary circuit.

Residual Current Monitoring Unit RCMU101SN-4P16C

Transducer for Measurement Bridges SCM90, SIGS15

The four pin one (J1) makes possible to supply the board and access to the output voltage easily. It has the following pin-out:

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Technical catalogue. Current sensors Voltage sensors

CPCO Series (160mm) DC-AC Current Probe, Clamp On ±4000A, ±8000A, ±12000A,

For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Customer: Standard type Page 1 of 7 Description Fluxgate current sensor with toroidal core PCB mounting

Current Sensor : F02P***S05L

AUTOMOTIVE CURRENT TRANSDUCER DHAB S/15

Transcription:

Ultra-stable, high precision (ppm class) fluxgate technology DS Series current transducer for non-intrusive, isolated DC and AC current measurement up to 2000A Features 20 ppm linearity 15 ppm offset 10V output in BNC connector @ 2000A Fluxgate, closed loop compensated technology with fixed excitation frequency and second harmonic zero flux detection for best in class accuracy and stability Industry standard DSUB 9 pin connection Applications: MPS for particles accelerators Gradient amplifiers for MRI devices Stable power supplies Precision drives Batteries testing and evaluation systems Power measurement and power analysis Current calibration purposes Green diode for normal operation indication Full aluminum body for superior EMI shielding and extended operating temperature range Large aperture 68mm for cables and bus bars Specification highlights Symbol Unit Min Typ Max Nominal primary AC current IPN AC v v 1414 Nominal primary DC current IPN DC A -2000 2000 Measuring range ÎPM A -2200 2200 Primary / secondary ratio V/kA -10 10 Linearity error ƐL ppm -20 20 Offset current (including earth field) IOE ppm -15 15 DC-10Hz Overall accuracy @25 C (= Ɛ L + I OE ) AC Maximum gain error 10Hz to 1kHz accɛ ppm -35 35 ƐG % ±0.01 Operating temperature range Ta C -40 65 Power supply voltages Uc V ±14.25 ±15.75 All ppm (or %) values refer to nominal current page 1-2017-02-02

Electrical specifications at Ta=23 C, supply voltage = ± 15V unless otherwise stated Parameter Symbol Unit Min Typ. Max Comment Nominal primary AC current I PN AC Arms 1414 Refer to fig. 1 & 2 for derating Nominal primary DC current I PN DC A -2000 2000 Refer to fig. 1 for derating Measuring range I PM A -2200 2200 Refer to fig. 1 & 2 for derating Overload capacity Î OL A 10000 Non-measured, 100ms Nominal output voltage I SN Vout -10 10 At nominal primary DC current Primary / secondary ratio Ratio V/kA 5.0000 5.0000 Linearity error ppm -20 20 ppm refers to nominal current µv -200 200 Offset offset ppm -15 15 ppm refers to nominal current V OE (including earth field) µv -150 150 DC-10Hz Overall accuracy @25 C (= ƐL + IOE ) Offset temperature coefficient accɛ ppm -35 35 ppm refers to nominal DC current ppm/k -0.1 0.1 ppm refers to nominal current µv/k -10 10 Bandwidth f (-3dB) khz 300 Small signal, graphs figure 3 Amplitude error 10Hz 1kHz 0.20% 1kHz -10kHz ƐG % 1.50% % refers to nominal current 10kHz - 100kHz 6.00% Phase shift 10Hz 1kHz 0.30º 1kHz -10kHz q º 1.50º 10kHz - 100kHz 15.0º Response time to a step current IPN tr @ 90% µs 1 di/dt = 100A/µs Noise 0-100Hz 0.02 0-1kHz 0.06 noise ppm rms 0-10kHz 0.6 0-100kHz 1.2 Fluxgate excitation frequency Induced rms voltage on primary conductor Power supply voltages Positive current consumption Ɛ L TC IOE f Exc khz 15.63 µv rms 5 Uc V ±14.25 ±15.75 Measured on secondary current Ips ma 160 165 190 Add Is (if Is is positive) Negative current consumption Operating temperature range Stability Offset stability over time Offset change with vertical external magnetic field Offset change with horizontal external magnetic field Offset change with power supply voltage changes Ins ma 150 160 170 Add Is (if Is is negative) Ta C -40 65 ppm / month µv /mt -1 1 ppm refers to nominal current µv /mt 2 8 8 20 µa refers to secondary current (perpendicular to bus bar) µa refers to secondary current (parallel to bus bar) µa refers to secondary current µv / V TBD µa refers to secondary current page 2-2017-02-02

Primary Current (A) DS2000UBLA-10V Frequency and ambient temperature derating (Fig. 2) 10000 Maximum primary current A rms 1000 100 10 1 10Hz 100Hz 1,000Hz 10,000Hz 100,000Hz 1,000,000Hz Primary Current (Hz) Max current (Arms) 65 deg Max current (Arms) 45 deg Max current (Arms) 25 deg Frequency characteristics (Fig. 3) 20.00 Amplitude / Phase 10.00 0.00-10.00-20.00-30.00-40.00 10Hz 100Hz 1,000Hz 10,000Hz 100,000Hz Amplitude (%) Phase Error (deg) page 3-2017-02-02

Isolation specifications Parameter Unit Value Clearance mm 22 Creepage distance mm 22 Comparative tracking index (CTI) V > 600 Rms voltage for AC isolation test, 50/60 Hz, 1 min - Between primary and (secondary and shield) - Between secondary and shield kv 14.4 0.2 Impulse withstand voltage (1.2/50µs) kv 26.3 Rated rms isolation voltage reinforced isolation, overvoltage category III, Pollution degree 2 according to - IEC 61010-1 - EN50780 V 1500 1500 Absolute maximum ratings Parameter Unit Max Comment Primary ka 10 Maximum 100ms Power supply V ±16.5 Environmental and mechanical characteristics Parameter Unit Min Typ Max Comment Ambient operating temperature range C -40 65 Storage temperature range C -40 65 Relative humidity % 20 80 Non-condensing Mass kg 6.5 Connections Standards Power supplies: D-SUB 9 pins male Voltage output: BNC connector EN 61326-1 EMC EN 61010-1:2010 Safety page 4-2017-02-02

Advanced Sensor Protection Circuits ASPC Developed to protect the current transducer from typical fault conditions: Unit is un-powered and secondary circuit is open or closed Unit is powered and secondary circuit is open or interrupted Both DC and AC primary current up to 100% of nominal value can be applied to the current transducers in the above situations without damage to the electronics. Please notice that the sensor core can be magnetized in all above cases, leading to a small change in output offset current (less than 10ppm) Status pins When transducer is operating in normal condition, the status pins (3 and 8) are shorted. Status pins properties: - forward direction pin 8 to pin 3, maximum forward current 10mA - maximum forward voltage 60V, maximum reverse voltage 5V Accessories 4-channel power supplies unit for connection up to 4 DS 2000A : DSSIU-4 Transducer cables in 4 lengths (2m - 5m - 10m ): DSUB2 - DSUB5 - DSUB10 Transducer cable 5m for connection to end-user s power supply: DSUB power cable (with access to current output via 4 banana jacks) Please visit Danisense homepage for relevant datasheets page 5-2017-02-02

DS2000UBLA-10V Mounting instructions Positive current direction Base plate mounting 4 holes 5.5 x 11 4 x M5 steel screws / 6N.m Bottom direct mounting (after unscrewing the base plate) 6 holes 4.2 x 7 6 x M4 steel screw / 4N.m Is identified by an arrow on the transducer body page 6-2017-02-02