RISH Ducer E13 3 channel transducer for AC current and voltage

Similar documents
RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

RISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

SINEAX U 553 Transducer for AC Voltage

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

RISH Ducer IXX / VXX Series (TRMS/Average) Transducer for AC current / AC Voltage (Single or Dual Output)

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

SINEAX TI 807 Passive DC signal isolator

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX G 537 Transducer for Phase Angle Difference

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Theta 20A / 20V. Technical Data Sheet. Special Features

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX I 552 Transducer for AC current

EURAX UI 505, Combined Transducer for AC current and AC voltage

Theta Hz. Technical Data Sheet. Special Features

EMBSIN 281 G Power factor transducer

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

SINEAX G 536 Phase Angle or Power Factor Transducer

SINEAX B 811 Power Pack with additional Functions

SUBJECT TO CHANGE WITHOUT NOTICE

Plug-in module SIRAX TI 807 Passive DC signal isolator

DEIF A/S. TAS-311DG Selectable AC transducer J (UK) Installation and start up instructions

DATA SHEET Selectable AC transducer TAS-311DG

ZIEGLER PRO-P Power / Phase Angle / Power Factor Transducer

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX TV809, 1 channel Programmable Isolating Amplifier

for DC currents or voltages, temperature sensors, remote sensors or potentiometers Application Principle of operation (Fig. 3) Features / Benefits

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX / EURAX 2I1 Passive DC signal isolator

DATA SHEET AC current single function transducer TAC-311DG/TAC-321DG

KINAX WT 707 Transmitter for angular position

MBS AG EMBSIN 120 UV. without auxiliary voltage supply housing for 35 mm DIN rail mounting

RISH Ducer V604 Programmable universal transmitter

Paladin Transducers 250 Series Class 0.5 and Class 0.2

Transducing electrical quantities Iskra MIS d.d. Measuring Transducers. Features

SINEAX V 604 Programmable universal transmitter

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Measuring current transformers of the W, W series

Data Sheet 066.8e. Transducers for Active and Reactive Power EW+B 2.2 DGW+B 2.2 VGW+B 2.2 DUW+B 2.2 VUW+B 2.2

Series P. Applications

POWER TRANSDUCERS ACTIVE AND REACTIVE SERIES: T-W WATT T-V VAR

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits

KINAX SR 719 Programmable Transmitter for Position Feedback

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

W DATA SHEET Current Transformer 40 x 10, A

Technical Data Sheet. x1000. kwh R Y B

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

Analogue Meters CQ0x07 series

For non-electrical quantities

MCR-SL-CUC Universal current transducer. Data sheet _en_05. 1 Description

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

POWER \ PHASE ANGLE \ POWER FACTOR TRANSDUCER RISH

XF2 Frequency Relay. Manual XF2 (Revision A)

MBS AG. KBR 18 Split-core current transformer. Further information about our new split-core current transformer KBR 18: Dimensions:

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

XP2-R Power and Reverse Power Relay

DATA SHEET. Switchboard instruments,

Current / residual current and voltage transformers. Current / residual current and voltage transformers

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

Inductive Standard Displacement Transducers

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

XI1-I Time overcurrent relay. (Januar 2007) Manual XI1-I (Revision New)

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN

VariTrans P V. Safe and Sound.

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

SINEAX V 604s Programmable multifunctional transmitter

EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters

Product Guide. Transducers

Protection and safety SQZ3 phase and sequence relay

Isolators A3/1. Vibration Transducer Supply Unit Series

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

CONTA-ELECTRONICS. Converter Units

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 35W 350mA 900mA TOP lp TOP series

Pulse Scaler for DIN Rail Attachment

Universal measuring transducer

PHASED OUT. LED Driver Linear / area fixed output. Driver LCI 20W 150mA 400mA TOP lp TOP series. Product description

XUA1 - AC Voltage and phase balance relay

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

VariTrans P D1 TRMS

E *) F 15. H 12 h9. 5.5f7 8h6. a./f approx. 0.5mm Free stroke. Displacement. Initial stroke

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Transcription:

RISH Ducer E13 3 channel transducer for C current and voltage The RISH Ducer E13 ( Fig. 1) converts 3 sine wave C current or C voltage into 3 output signals that can serve several receiving instruments such as indicators, recorders, alarm units etc. Features / Benefits Up to 3 measuring inputs: C currents or C voltages sine wave-form, arithmetical mean value measurement, calibration to rms with sine wave form Measured variables C currents C voltages Measuring range limits 0 0.01 to 0 10 0 10 to 0 750 V Three measuring outputs: DC current signal (load independent)or DC voltage signal Low power consumption / Smaller CT s and VT s can be used Provision for either snapping the transducer onto top-hat rails or securing it with screws to a wall or panel Manufactured in SMD technology / compact and reliable Screw terminals suitable for multistoried or thick solid wires. Electric isolation between input / output and power supply (3.7 kv) / personnel protection assured Electric isolation between channels is 500V Layout and mode of operation I~ U~ W G V Fig.1. RISH Ducer E 13 transducer screw hole mountion brackets pulled out. The measured variable I/U C is isolated from the electronics by the transformer W, and is rectified and smoothed in thev rectifier unit G following. The output amplifier V amplifies this quantity and converts it into the load-independent DC output signal. With C power supply the supply is processed by a mains transformer with three isolated secondary windings. Tr H ~ C/DC Fig. 3. Block diagram for a function unit. Technical data General Measuring output Measured quantity: C current or C voltage sinusoidal Output variable : rithmetical mean measured, calibration to rms with sine wave form Nominal values of I : Measuring principle: ctive rectifier Measuring input E Nominal frequency fn 1 : 50 or 60 Hz Nominal input current IN (full range end value) 2 : 1 / 1.2 / 5 or 6 Nominal input voltage UN 100/ 3, 110/ 3 / 120/ 3 / 100 / (full range end value) 3 : 110 /116.66 / 120 / 125 /133.33 / 150 / 250 / 400 or 500 V Consumption: < 0.2 V per current circuit < 1 m per voltage circuit Sensitivity: < 0.05% of full range end value Overload capacity: Measured Variable IN, UN Number of applications Duration of one application Interval between two successive applications 2 x IN continuously --- --- 10 x IN 5 15 s 5 min. 40 x IN 1 1 1 s --- 1,5 x UN continuously --- --- 2 x UN 10 10 s 10 s 4 x UN 1 2 s --- 1 6 7 Nominal value of U 4 5 Voltage limit under Rext. = Current limit under overload Output current ripple Response time 1 to 7 see Table 2: Load-independent DC current I or load-independent DC voltage U 0 1, 0 5, 0 10, 0 20 or 4 20 m Burden voltage 15 V Rext max. [kω] = 15 V IN [m] IN = End output curr 0 10 or 1 5 V Load capacity 20 m External resistance Rext max. [kω] = U 20 m pprox. 40V pprox. 1.3 x I N at current output pprox. 30 m at voltage output 1% p.p. < 300 ms special features"

RISH Ducer E13 3 channel transducer for C current and voltage ccuracy (acc. to DIN/IEC 688-1) Reference value: Output span Basic accuracy: Class 0.5 Reference conditions mbient temperature 23 C, ± 5 K Pre-conditioning: 30 min. acc. to EN 60 688 Section 4.3, Table 2 input 0 100% Frequency fn ±2% Distortion factor < 0.2% Power supply UHN ±1% External resistance : 0 R ext max. for current output Rext.min.. for voltage output Output voltage : 0...15 V Output current : 0...20 m Influence effects (maxima) (included in basic error) Linearity error ± 0.2% Frequency fn ± 5 % ± 0.05% Dependence on external resistance Rext max. ± 0.2% Power supply influence UH ± 10 % dditional errors Temperature influence ( 25 + 55 C) ± 0.5% / 10 K Frequency influence 45 65 Hz ± 0.5% Stray field influence 0,5 mt Influence of common mode ± 0.5% voltage 220V, 50Hz or 10V,1Mz ± 0.5% Output characteristic 3 Power supply C voltage : Installation data Mechanical design: Material of housing: Mounting: Mounting position: Electrical connections: Weight: Regulations Electrical standards: Housing protection: Test voltage: Environmental conditions Climatic rating: Storage temperature: 110 or 230 V ± 10%, 50 / 60 Hz Power input approx. 8 V Carrying rail housing type E16 Dimensions see section Dimensional drawing Lexan 940 (polycarbonate) Flammability Class V-0 according to UL 94, self extinguishing, nondripping, free of halogen For snapping onto top-hat rail (35 x 15 mm or 35 x 7.5 mm) acc. to EN 50022 or directly onto a wall or panel using the pull-out screw hole brackets ny Screw type terminals with indirect wire pressure, for max. 2 x 2.5 mm 2 or 1 x 6 mm 2 pprox. 0.9 kg cc. to DIN 57 410 IP 40 acc. to IEC 529 3.7 kv, 50 Hz, 1 min. between electrically insulated circuits. 0.5 kv, 50Hz, 1 min. between any two channels. Climate class 3Z acc. to VDI/VDE 3540, but temperature continuously 25 to + 55 C. Relative humidity 75% annual mean (application class HVE acc. to DIN 40 040) -40 to + 70 C 1 E E1 E2 Fig.4. Characteristic Standard 3 2 1 E1 E2 E Fig.5. Characteristic B Standard and live-zero Condition: 2 = 0.2 3 2

RISH Ducer E13 3 channel transducer for C current and voltage Table 1: Specification and ordering information Order Code E13 Features, Selection *SCODE no-go 1.Mechanical design 3) Housing E16 3........ 2. Nominal frequency 1) 50 / 60 Hz.. 1...... 2) non-standard [Hz] 16 to 400 1.. 9...... 3. Input E1 (measuring input E) 1) 0... 1 B... 1..... 2) 0... 1.2 B... 2..... 3) 0... 5 B... 3..... 4) 0... 6 B... 4..... 9) Non-standard [] 0...0.01 to 0...10 2 B... 9..... ) 0...100 / 3 V B........ B) 0...110 / 3 V B... B..... C) 0 120 / 3 V B... C..... D) 0...100 V B... D..... E) 0...110 V B... E..... F) 0...116.66 V B... F..... G) 0...120 V B... G..... H) 0...125 V B... H..... J) 0...133.33 V B... J..... K) 0...150 V B... K..... L) 0...250 V B... L..... M) 0... 400 V B... M..... N) 0... 500 V B... N..... Z) Not-standard [V] 0...10.00 to 0...750 V 3 B... Z..... 4. Input E2 (measuring input E) 1) 0 1 B.... 1.... 2) 0...1.2 B.... 2.... 3) 0...5 B.... 3.... 4) 0...6 B.... 4.... 9) Non-standard 2 [] B 0...0.01 to 0...10.... 9.... ) 0...100 / 3 V B........ B) 0...110 / 3 V B.... B.... C) 0 120/ 3 V B.... C.... D) 0...100 V B.... D.... E) 0...110 V B.... E.... F) 0 116.66 V B.... F.... G) 0...120 V B.... G.... 1, 2 and 3 see Table 2: Special features 3

RISH Ducer E13 3 channel transducer for C current and voltage Order Code E13 Features, Selection *SCODE no-go H) 0...125 V B.... H..... J) 0 133.33 V B.... J..... K) 0...150 V B.... K..... L) 0 250 V B.... L..... M) 0...400 V B.... M..... N) 0 500 V B.... N..... Z) Non-standard [] 0...10.00 to 0...750 V 3 B.... Z..... 5. Input E3 ( Measuring input E) 1) 0...1 B..... 1.... 2) 0...1.2 B..... 2.... 3) 0...5 B..... 3.... 4) 0...6 B..... 4.... 9) Non-standard []..... 9.... B 0...0.01 to 0...10 2 ) 0...100/ 3 V B......... B) 0...110/ 3 V B..... B.... C) 0 120/ 3 V B..... C.... D) 0...100 V B..... D.... E) 0...110 V B..... E.... F) 0 116.66 V B..... F.... G) 0 120 V B..... G.... H) 0 125 V B..... H.... J) 0 133.33 V B..... J.... K) 0 150 V B..... K.... L) 0...250 V B.... L.... M) 0 400 V B..... M.... N) 0...500 V B..... N.... Z) Not-standard [V] 0...10.00 to 0...750 3 B..... Z.... 6. Output signal 1 (measuring output) 1) 0...10 V, Rext 500 Ω...... 1... 2) 1 5 V, Rext 250 Ω...... 2... 9) Non-standard 0 1.00 to 0 15 4 [V] 0.2 1 to 3 15 5...... 9... ) 0 1 m, Rext 15 kω......... B) 0 5 m, Rext 3 kω...... B... C) 0 10 m, Rext 1.5 kω...... C... D) 0 20 m, Rext 750 Ω...... D... E) 4 20 m, Rext 750 Ω...... E... Z) Non-standard 0 >1.00 to 0.< 20 6 [m] 1 5 to < (4 20) 7...... Z... 4

RISH Ducer E13 3 channel transducer for C current and voltage Order Code E13 Features, Selection *SCODE no-go 7. Output signal 2 (measuring output) 1) 0...10 V, Rext 500 Ω....... 1.. 2) 1...5 V, Rext 250 Ω....... 2.. 9) Non-standard 0 1.00 to 0 15 4 [V] 0.2 1 to 3 15 5....... 9.. ) 0 1 m, Rext. 15 kw......... B) 0 5 m, Rext. 3 kω....... B.. C) 0 10 m, Rext. 1.5 kω....... C.. D) 0 20 m, Rext. 750 Ω....... D.. E) 4 20 m, Rext. 750 Ω....... E.. Z) Non-standard 0 > 1.00 to 0 < 20 6 [m] 1 5 to < (4 20) 7....... Z.. 8. Output signal 3 (measuring output) 1) 0...10 V, Rext 500 Ω........ 1. 2) 1...5 V, Rext 250 Ω........ 2. 9) Non-standard 0 1.00 to 0 15 4 [V] 0.2 1 to 3 15 5........ 9. ) 0 1 m, Rext. 15 kω......... B) 0 5 m, Rext. 3 kω........ B. C) 0 10 m, Rext. 1.5 kω........ C. D) 0 20 m, Rext. 750 Ω........ D. E) 4 20 m, Rext. 750 Ω........ E. Z) Non-standard 0 > 1.00 to 0 < 20 6 [m] 1 5 to < (4 20) 7........ Z. 9. Power supply 1) 110 V, 50/60 Hz......... 1 2) 230 V,50/60 Hz......... 2 4 to 7 see Table 2: special features Table 2: Special features Nature of special features Nature of special features Nominal frequency fn Nominal input voltage UN 1 between 16 to 400 Hz, besides the standard ranges 50 / 60 Hz 3 between 0...10 and 0...750 V, besides the standard ranges 0...100/ 3 / 0...110/ 3 /0...120/ 3 / 0...100/ 0...110 / 0...116.66 / 0...120 / 0...125 / 0...133.33 / 0...150 / 0...250 / 0...400 and 0...500 V Restriction: With UN > 500 V: Overload capacity 2000 V, 2 s Nominal input current IN Output signal (measuring output ) 2 between 0...0.01 to 0...10, besides the standard ranges 0...1 / 0...1.2 / 0...5 and 0...6 Restrictions: With I N > 5 : Own consumption < 0.3 V Overload capacity: 15 continuously 100 for 10 s, max. 5 times at 5 minute intervals 250 for 1 s, once only Nominal frequency f N 40 Hz With IN > 8.3 : Reference conditions IE 10 4 Load-independent DC voltage unipolar Ranges between 0...1 and 0...15 V, besides the standard range 0...10 V 5 Live-zero Ranges between 0.2...1 and 3...15 V, besides the standard range 1...5 V 5

125 130 125 140 154 Ø4.5 RISH Ducer E13 3 channel transducer for C current and voltage Nature of special features Output signal (measuring output ) 6 Load-independent DC current unipolar Ranges between 0...1 and 0...20 m, besides the standard ranges 0...1/0...5/0...10 and 0...20 m 7 Live-zero Ranges between 1..5 and 4...20 m, besides the standard range 4...20 m O/p1 O/p2 O/p3 - + - + - + O/p1 O/p2 O/p3 - + - + - + 9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16 UL1 UL2 UL3 = Measuring inputs Front Front IL1 IL2 IL3 = Measuring outputs = Power supply ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ IL1 IL2 IL3 UL1 UL2 UL3 Fig. 6. RISH Ducer E13 Fig. 7. RISH Ducer E 13 for C current measurement for C voltage measurement Dimensional drawings 19 6.5 9 10 11 12 13 14 15 16 9 10 11 12 13 14 15 16 70 126 70 12 125 Fig. 8. RISH Ducer E13 in housing E16 clipped onto a top hat rail Fig. 9. RISH Ducer E13 in housing E16 with the screw hole brackets pulled (35 x 15 mm or 35 x 7.5 mm) acc. to EN 50022 out for wall mounting. 6