Live Loading Of Flange Joints To Prevent Leaks And Reduce Fugitive Emissions. W.C.Offutt P.E.

Similar documents
Practical Bolting and Gasketing for the Non Standard-Flanged Joint

GUIDELINES FOR HINGED AND BOLTED MANWAY ASSEMBLY

Joint Preparation prior to Tensioning: General:

A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training

A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training

UNIVERSITY OF THESSALY

STUDY AND ANALYSIS OF ANGULAR TORQUING OF ENGINE CYLINDER-HEAD BOLTS USING TORQUE-TO-YIELD BOLTS: A CASE STUDY

NTTC Tank Truck Week Awareness Gaskets/Fasteners/Flanges

Joint relaxation behaviour of gasketed bolted flanged pipe joint during assembly

TORQUE DESIGN, ANALYSIS AND CHARACTERIZATION OF CRITICAL FASTENERS IN DIESEL ENGINES

Modeling Multi-Bolted Systems

Figure 11 Flange Adapter and Back-Up Ring

Fluid Sealing Association

Installation, Maintenance and Operating Instructions

A training course delivered to Engineers and Designers, at a company s premises, on the technical aspects of bolting.

Washers - a critical element of successful bolting integrity. A technical article presented by James Walker

HEATEC TEC-NOTE Publication No

Emission-Pak Assemblies

MECH-100: Fundamentals of Precision Maintenance

Failure of Engineering Materials & Structures. Code 34. Bolted Joint s Relaxation Behavior: A FEA Study. Muhammad Abid and Saad Hussain

UNDERSTANDING TORQUE -ANGLE SIGNATURES OF BOLTED JOINTS

Reliance SG777 Series Steel Water Gage Valves

SYGEF Standard SYGEF Plus PVDF Flanges

Reliance SG800 Series Steel Water Gage Valves

MECHANICAL ASSEMBLY John Wiley & Sons, Inc. M. P. Groover, Fundamentals of Modern Manufacturing 2/e

Finite Element Modeling of Early Stage Self-loosening of Bolted Joints Haoliang Xu 1, a, Lihua Yang 1, b,, Lie Yu 1,2, c

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL

What is a fastener? A device to locate or hold parts

1/2/2016. Lecture Slides. Screws, Fasteners, and the Design of Nonpermanent Joints. Reasons for Non-permanent Fasteners

ENGINEERING FUNDAMENTALS

Typical Group D Rear Acoustical Cover Installation

General Array Layout Sketch

TECH SHEET PEM - REF / THREAD GALLING. SUBJECT: Root causes and guidelines to promote optimized fastener performance TECH SHEET

INSTALLATION MANUAL for KLINGER gaskets

Hydraulic Tensioner Assembly: Load Loss Factors and Target Stress Limits

Big Block Installation Manual For Systems without A/C

Technical information

SIGHT GLASS. Sight glass components allow operators to safely observe processes inside tanks, pipes, reactors and vessels.

PROCEDURE:INSTALLATION OF BOLTED AND THREADED CONNECTIONS. as a result of improper lifting technique.

BOLT PRELOAD CONTROL FOR BOLTED FLANGE JOINT. Hirokazu TSUJI Department of Intelligent Mechanical Engineering, Tokyo Denki University Saitama, Japan

Variables Affecting The Assembly Bolt Stress Developed During Manual Tightening

VALVTECHNOLOGIES, INC. INSTALLATION, OPERATIONS & MAINTENANCE MANUAL STEAM CHOKE VALVES

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections

Fasteners. Bolts. NAPA FastTrack Counter Sales Training Fasteners Page 1. Figure 1. Typical Measurements for a Bolt or Hex Head Cap Screw

25000 Series Lo-T TM Butterfly Control Valve Instructions

D DAVID PUBLISHING. Analysis of Leakage in Bolted-Flanged Joints Using Contact Finite Element Analysis. 1. Introduction.

Mechanical joints. Major diameter Mean diameter Minor diameter Pitch p chamfer. Root Crest. Thread angle 2a. Dr. Salah Gasim Ahmed YIC 1

4-8 HSF 250 Patriot. Line Stop Fitting Installation Instructions. Installation Instructions and Best Practices continued on back

Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS

Tightening Strategies for Bolted Joints Methods for Controlling and Analyzing Tightening

C h a s s i s F r a m e

Fasteners. Fastener. Chapter 18

a) If a bolt is over-tightened, which will fail first the bolt, or the plastic?

FASTENERS FIRST LOOSEN WITHOUT TURNING!

Before assembly is started, all working surfaces shall be cleaned and visually examined.

Series 4000 Model B 3-Piece Ball Valves with ISO Bonnet

Series 4000 Model B 3-Piece Ball Valves with ISO Bonnet

When we are torquing a fastener, the specified torque must include the

UNIT 9b: SCREW FASTENERS Introduction Functions Screw Features Elements Terms of a Thread Profile

1/2 2 (DN 15 50) Standard Bore Series /2 1-1/2 (DN 15 40) Full Bore Series 9000 Flanged Ball Valves with ISO Bonnet

Understanding pipe threads: types and designations

Technical Manual. ETP-CLASSIC incl type R. Content

DETERMINATION OF JOINT DIAGRAMS FOR A FOUNDATION BOLTED JOINT WITH THE BOLT ANCHORED IN A POLYMER PLASTIC

MECH 344/M Machine Element Design

The Stamina of Non-Gasketed, Flanged Pipe Connections

The Ultimate Critical Service Triple Offset Valve INSTALLATION, OPERATION & MAINTENANCE MANUAL

REVIEW OF THREADED FASTENERS LOOSENING AND ITS EFFECTS

LOCTITE WEBINAR SERIES Threadlocking & the Torque-Tension Relationship

USER MANUAL Nord-Lock X-series washers

Bolted Joint Design. Mechanical Properties of Steel Fasteners in Service

The Ultimate Critical Service Triple Offset Valve INSTALLATION, OPERATION & MAINTENANCE MANUAL

5.1 MUELLER CORPORATION VALVES. MUELLER 300 Ball Type Corporation Valves

HEICO FASTENING SYSTEMS. Simple Fast Reliable HEICO-TEC TENSION NUT

General Information. Ball Curb Valve

Axles Covered in This Bulletin. How to Obtain Additional Maintenance, Service and Product Information. Product Design Variations. How to Obtain Kits

4" (DN 100) 5RET Tank Car Fire-Tite Bottom Unloading Valves. Installation, Maintenance and Operating Instructions

Assembly instructions for swivel mechanical joints Bondstrand fiberglass pipe series

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34.

Fisher 667 Diaphragm Actuators Size 80 and 100

In normal joints, the clamping force should equal the working load. In gasketed joints, it should be sufficient to create a seal.

PARTITION INSTALLATION INSTRUCTIONS

Tex-452-A, Rotational Capacity Testing of Fasteners Using a Tension Measuring Device

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections

General Four-Way Operation, Maintenance & Service Manual

Gasket Installation Procedures. Assuring! joint integrity and! maximum safety

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. The main is drilled out under pressure.

The Redi-Flange Method. How It Works. Services. Engineering & Costing Assistance

Magnetic level indicators made in Australia under licence to Weka AG of Switzerland.

SAFETY PRECAUTIONS GENERAL INFORMATION

bolts: G Cr-1/5Mo (A193 B7) 16 x M20 (EN ISO 4014) MPR GASKET 'SP' PETRO 4,0mm 363 x 323 x 4,5 mm (2 pieces)

3 Emergency Breakaway Coupling

LPK1550 Hydraulic Crimping Tool 15-ton

An Introduction to Grayloc Products! Serving your Piping and Pressure Vessel requirements for over 50 years!

INSTALLATION, OPERATION & MAINTENANCE. Adjustable Horizontal Water Closet Carrier

GOOD AND TIGHT FOR THE RIGHT TIGHT, TIGHTER IS BETTER: A DESCRIPTION OF ASME MODERN FLANGE DESIGN

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

Big Bolts Better? Choices for Performance and Economy

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW

Nord-Lock X-series washers

PO STYLE AIR CLUTCH INSTALLATION AND MAINTENANCE MANUAL

Transcription:

Live Loading Of Flange Joints To Prevent Leaks And Reduce Fugitive Emissions W.C.Offutt P.E. Bolted flange joint leaks have always been a problem. In the past, little was done to try to eliminate the problem. More recently new gasket materials and some new bolting techniques have made some improvements. But in high temperature / high pressure applications, the problem still exists. In fact, with the passage of The Clean Air Act Of 1990", the problem is even more critical than ever. Today, even the definition of a leak has changed. Prior to 1990, a flange was considered leaking if the leak rate was 10,000 PPM or greater. Under todays new rules, a leak must be repaired if the leak rate is 500 PPM or above. This rate can even be lower depending on the process in the system and varying state and local regulations. Not only must the flange be leak free at installation, it must maintain a leak rate of 500 PPM or below for a longer period of time. This is due to the EPAs new monitoring regulations on Fugitive Emissions. Flange joints encompass conventional ANSI pipe flanges, heat exchangers headers, tube sheet, sight gages, manways, handholes, valve bonnets and almost any bolted gasketed joint. A bolted flange joint leaks when the material contained in the system escapes through the gasket pores or around the gasket and the flange face. This usually occurs because the load on the gasket has fallen below its minimum seal pressure. Preventing flange leaks can be a difficult task. It is necessary to maintain the contact pressure above the minimum seal pressure between the flange and the gasket surfaces. This must be done initially, as the gasket and bolts relax, and also as the temperature and pressure of the contained process changes, The initial preload can be attained by using several tried and true methods. The problem is maintaining this preload through the life of the joint. The following are the main factors that cause bolted flange joints to leak and how and why the use of Solon Flange Washers (specially engineered belleville springs for high temperature flange applications) can prevent flange leaks and reduce Fugitive Emissions: 1. Embedment Relaxation 2. Gasket Creep 3. Vibration 4. Elastic Interaction 5. Differential Thermal Expansion Embedment Relaxation

When new suds and nuts are first tightened, both the stud and nut threads and the joint contact surfaces, contact each other only on microscopic high spots. These high spots will be grossly overloaded, well beyond their yield point. Therefore, plastic flow will continue until the contact area increases sufficiently to stabilize or stop the yielding process, relaxing the load on the bolt. This can account for as much as 5-10% loss in initial preload. Retightening the parts can partially compensate for this type of relaxation. Embedment relaxation is virtually unavoidable and cannot be prevented, but you can compensate for it. Gasket Creep Most gaskets are made of plastic or semiplastic materials. They must deform to do the job intended. Like any plastic material, they will creep and flow when first subjected to high surface loads. Most of the gaskets used today in high temperature / high pressure applications have reasonable loading curves and fairly steep unloading curves. (Figure 1) Because of this, even the slightest loss in load can cause a joint to fall below the minimum seal pressure. Like embedment relaxation, gasket creep is unavoidable. Figure 2 illustrates the effect on the unloading of a gasketed flange joint using belleville springs. Solon Flange Washers compensate for the gasket relaxation sufficiently to maintain the joint compression well above the minimum seal pressure. Figure 1 Figure 2

Bolt Creep Bolted flange joints in high temperature service will have a reduction in tension due to a reduction of the Youngs Modulus and will relax with time. This is in addition to the initial embedment and gasket relaxation. Figure 3 illustrates this reducation in bolt tension at 1000 hours versus the bolt operating temperatures. Vibration Vibration can also be a factor causing flange joints to leak. Loosening due to vibration starts at a very low rate and a very gradual relaxation from the original preload. (Figure 4) When the preoload tension falls below a critical value, the relaxation rate increases, and the nut may even rotate and further loosen the joint. Figure 3 Elastic Interaction Gasketed bolted joints should be pattern tightened in stages. Irregular tightening or loading can distort and damage the flange and gasket. In theory, one shouold tighten all bolts simultaneously. This is very difficult to attain. Therefore, a more practical procedure is to tighten all the stud bolts in stages. This is usually done by using a cross pattern sequence around the bolt pattern. The first pass is tightened to approximately 30% of the final desired preload. The second pass is done using 60% of the final preload, and the same bolting sequence. The third pass is done using 100% of the final preload, again using the same sequence. Elastic Interaction is a phenomenon which occurs between bolts and joint members as a group of bolts are tightened. When the first bolt in a joint is tightened, the bolt is stretched and the joint Is partially compressed. When an adjacent bolt is tightened, the joint in the vicinity of the first bolt is further compressed. This allows the first bolt to relax. Even if a perfect initial preload had been achieved on these bolts, only the second bolt would have that preload. These load losses, depending on the stiffness of the joint, may be 50 to 60% of the Figure 4 Figure 5

original bolt tension. Just the tightening of the second bolt eliminates some of the preload of the first bolt. The amount of the elastic interaction depends on the size of the joint, the type of gasket used, the distance between bolts, and the stiffness of the members. Figure 5 shows the relaxation of a single bolt using this procedure. In the event all studs are tightened simultaneously, relaxation can and will occur after the final tightening. This is shown in Figure 6. Another problem that occurs when tightening bolted gasketed joints, is the inconsistent preload between all the bolts. This is thought to occur because of bolt relaxation and elastic interaction. This inconsistency or scatter seems to be a common problem with joints that are tightened using torque control. Figure 6 Figure 7 is a plot of the residual preload of a flange with 16-1 1/4 inch bolts. The bolts were torqued using the method previously mentioned. Measurements were taken after each pass. The sawtooth pattern is the result of relaxation and elastic interaction between the bolts. This sawtooth pattern remained even after four additional clockwise passes at a torque of 275 ft. lbs. Figure 8 shows an additional plot of this same flange with bellevile springs added to each bolt. The addition of the Solon Flange Washers reduces the preload scatter and nearly eliminates the sawtooth bolt tension pattern. Figure 7 Differential Thermal Expansion As temperatures rise most materials expand. In a flange joint the heat is usually coming from the process in the system. Since the gasket and the flange are in closer contact with the process Figure 8

stream, they heat up faster than the bolts. This means that the joint members are expanding more than the bolts. This increases the tension in the bolts and increase the load on the gasket. The extra load on the gasket compresses it more than it was during assembly, which occurred at ambient temperatures. If the system cycles and the joint cools down, the joint members will return to their original thickness. Since the gasket was further compressed and it is not fully elastic, it cannot return to its initial compressed thickness. This allows the bolt to relax, and some of the initial bolt load is lost. If this heating and cooling repeats enough times, it can reduce the initial bolt load and gasket load to a point that the flange will leak. Solon Flange Washers can be used to eliminate the effects of differential thermal expansion. The movement in the joint is taken up by the movement of the flange washer, and the load on the bolt and gasket will still be above its minimum seal pressure. An additional benefit of using Solon Flange Washers is that they do not need to be retorqued after the system has come up to operating temperature. Also, some flanges can now be insulated that could not previously be insulated. There are many methods used to compensate for the various factors working to reduce the initial bolt load and gasket load on a bolted joint. Some are bettor than others, but none of them do much to maintain the loads needed to prevent the joint from leaking once the system is in operation and cycling for any amount of time. Solon Flange Washers are constantly working to maintain a tight, leak free joint. When considering the alternatives, the use of Solon Flange Washers is the most economical method to reduce bolted flange joint leaks, thus reducing fugitive emissions. References 1. Bickford, John, An Introduction To Design & Behavior Of Bolted Joints 2. Bickford, John, Ultrasonic Control Of Bolt Load, Raymond Engineering Inc. 3. Bickford, John, Bolted Joint Which Leak, The Distributors Link, Spring, 1993 4. Bickford, John, That Initial Preload - What Happens To It?, Mechanical Engineering, October, 1983 5. Bickford, John, Bolt Torque: Getting It Right, Machine Design, June, 1990 6. Winter, J. Ronald, Gasket Selection - A Flowchart Appraoch, August 15, 1990 7. Payne, Jim, Bolted Joint Improvement Through Gasket Performance Tests, Presented at the 1992 NPRA Maintenance Conference, San Antonio, Texas 8. ASM Metals Handbook, Vol. 1, Properties and Selection of Materials 9. 1990 Federal Clean Air Act Amendments, (FCCA) Title 1 - Hazardous Air Pollutants

For Additional information and catalogs on flange live loading and valve live loading, contact: PO Box 207 Chardon, Ohio 44024-0207 800-323-9717 440-286-9047 Fax Website www.solonmfg.com E-Mail solon@solonmfg.com SM T RP 398