Introduce system protection relays like underfrequency relays, rate of change of frequency relays, reverse - power flow

Similar documents
Fundamentals of Power System Protection 1

Modeling of overhead transmission lines with line surge arresters for lightning overvoltages. Poland

Modle 6 : Preventive, Emergency and Restorative Control. Lecture 29 : Emergency Control : An example. Objectives. A simple 2 machine example

Level 6 Graduate Diploma in Engineering Electrical Energy Systems

Education & Training

EH2741 Communication and Control in Electric Power Systems Lecture 2

Busbars and lines are important elements

Session Four: Practical Insulation Co-ordination for Lightning Induced Overvoltages

Modeling insulation in high-voltage substations

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

Overvoltage Protection

Power System Stability. Course Notes PART-1

Smart Grid Where We Are Today?

Analysis of lightning performance of 132KV transmission line by application of surge arresters

DISTRIBUTION SYSTEM VOLTAGE SAGS: INTERACTION WITH MOTOR AND DRIVE LOADS

Generation and Load Interconnection Standard

B2-301 IMPROVING DOUBLE CIRCUIT TRANSMISSION LINE RELIABILITY THROUGH LIGHTNING DESIGN

Power System Protection Where Are We Today?

ABSTRACTS of SESSION 6

Research on State Estimation and Information Processing Method for Intelligent Substation

Course No: 1 13 (3 Days) FAULT CURRENT CALCULATION & RELAY SETTING & RELAY CO-ORDINATION. Course Content

DEPARTMENT OF EEE QUESTION BANK

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

2000 Mathematics Subject Classification: 68Uxx/Subject Classification for Computer Science. 281, 242.2

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

CONTENTS. 1. Introduction Generating Stations 9 40

Generation and Load Interconnection Standard

Utility Interconnection and System Protection

Electrical Power Systems

Single Line Diagram of Substations

PREVENTING FLASHOVER NEAR A SUBSTATION BY INSTALLING LINE SURGE ARRESTERS

Power Plant and Transmission System Protection Coordination Fundamentals

U I. Time Overcurrent Relays. Basic equation. More or less approximates thermal fuse. » Allow coordination with fuses 9/24/2018 ECE525.

Utility System Lightning Protection

Power systems Protection course

ELEC Transmission i and

When surge arres t ers are installed close to a power transformer, overvoltage TRANSFORMER IN GRID ABSTRACT KEYWORDS

Grid codes and wind farm interconnections CNY Engineering Expo. Syracuse, NY November 13, 2017

The Problem of Interference

NERC Protection Coordination Webinar Series July 15, Jon Gardell

Unit 2. Single Line Diagram of Substations

System Protection and Control Subcommittee

High voltage engineering

Power Plant and Transmission System Protection Coordination

Electrical Protection System Design and Operation

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

LIGHTNING OVERVOLTAGES AND THE QUALITY OF SUPPLY: A CASE STUDY OF A SUBSTATION

2 Grounding of power supply system neutral

Type CP-S, CP-C & CP-A Switch mode

Hazard of Induced Overvoltage to Power Distribution Lines Jiang Jun, Zhao Rui, Chen Jingyang, Tian Hua, Han Lin

COMPARATIVE PERFORMANCE OF SMART WIRES SMARTVALVE WITH EHV SERIES CAPACITOR: IMPLICATIONS FOR SUB-SYNCHRONOUS RESONANCE (SSR)

Fatima Michael College of Engineering & Technology

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network

Transmission System Phase Backup Protection

Calculation of Transient Overvoltages by using EMTP software in a 2-Phase 132KV GIS

Texas Reliability Entity Event Analysis. Event: May 8, 2011 Loss of Multiple Elements Category 1a Event

Module 2 : Current and Voltage Transformers. Lecture 8 : Introduction to VT. Objectives. 8.1 Voltage Transformers 8.1.1Role of Tuning Reactor

High Voltage DC Transmission 2

Lightning performance of a HV/MV substation

Adaptive Autoreclosure to Increase System Stability and Reduce Stress to Circuit Breakers

HISTORY: How we got to where we are. March 2015 Roy Boyer 1

Time over/underfrequency relay with protection assemblies

EE 741. Primary & Secondary Distribution Systems

Zdeslav Čerina, dipl. ing. Robert Kosor, dipl. ing. Sergio Gazzari, dipl. ing. Hrvatska elektroprivreda d.d., Croatia ABSTRACT

ISSUES OF SYSTEM AND CONTROL INTERACTIONS IN ELECTRIC POWER SYSTEMS

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

Application for A Sub-harmonic Protection Relay. ERLPhase Power Technologies

Lightning test in lab. Symmetrical fault and protection. Olof Samuelsson

Transmission of Electrical Energy

The relationship between operating maintenance and lightning overvoltage in distribution networks based on PSCAD/EMTDC

System Protection and Control Subcommittee

NERC Protection Coordination Webinar Series June 23, Phil Tatro

ABSTRACT 1 INTRODUCTION

The Effect of Lightning Parameters on Induced Voltages Caused by Nearby Lightning on Overhead Distribution Conducting Line.

Substation: From the Outside Looking In.

Power Quality Basics. Presented by. Scott Peele PE

International Journal of Advance Engineering and Research Development

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

Inverter-Based Resource Disturbance Analysis

STANDARDS/MANUALS/ GUIDELINES FOR SMALL HYDRO DEVELOPMENT

Module 9. Fault Type Form 4.X RELIABILITY ACCOUNTABILITY

ANALYSIS OF A FLASHOVER OPERATION ON TWO 138KV TRANSMISSION LINES

Simulations of open phase conditions on the high voltage side of YNd05-power plant transformers

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016

Transformer Technology Seminar Winding Selection

Conventional Paper-II-2011 Part-1A

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

An Investigation of Controlled System Separation Following Transient Instability

EE171. H.H. Sheikh Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

NVESTIGATIONS OF RECENT BLACK-

Development of an Experimental Rig for Doubly-Fed Induction Generator based Wind Turbine

Preface...x Chapter 1 Electrical Fundamentals

Power Quality and Reliablity Centre

IV/IV B.Tech (Regular) DEGREE EXAMINATION. Electrical &Electronics Engineering

Loss of Mains Protection

Zambezi (previously Caprivi) Link HVDC Interconnector: Review of Operational Performance in the First Five Years

O V E R V I E W O F T H E

Transmission Availability Data System Definitions

TECHNICAL BULLETIN 004a Ferroresonance

Transcription:

Module 1 : Fundamentals of Power System Protection Lecture 3 : Protection Paradigms - System Protection Objectives In this lecture we will: Overview dynamics in power systems. Introduce system protection relays like underfrequency relays, rate of change of frequency relays, reverse - power flow relays etc. Give a brief introduction to lightning protection. 3.1Overview of Power System Dynamics Usually, system protection requires study of the system dynamics and control. To understand issues in system protection, we overview dynamical nature of the power system. Power system behavior can be described in terms of differential and algebraic system of equations. Differential equations can be written to describe behaviour of generators, transmission lines, motors, transformers etc. The detailing depends upon the time scale of investigation. Figure 3.1 shows the various time scales involved in modelling system dynamics. The dynamics involved in switching, lightening, load rejection etc have a high frequency component which die down quickly. In analysis of such dynamics, differential equations associated with inductances and capacitances of transmission lines have to be modelled. Such analysis is restricted to a few cycles. It is done by Electromagnetic Transient Program (EMTP). At a larger time scale (order of seconds), response of the electromechanical elements is perceived. These transients are typically excited by faults which disturb the system equilibrium by upsetting the generatorload balance in the system. As a consequence of fault, electrical power output reduces instantaneously while the mechanical input does not change instantaneously. The resulting imbalance in power (and torque) excites the electromechanical transients which are essentially slow because of the inertia of the mechanical elements (rotor etc). Detection and removal of fault is the task of the protection system (apparatus protection). Post-fault, the system may or may not return to an equilibrium position. Transient stability studies are required to determine the post fault system stability. In practice, out-of-step relaying, under frequency load shedding,

islanding etc are the measures used to enhance system stability and prevent blackouts. The distinction between system protection and control (e.g. damping of power swings) is a finer one. In the today's world of Integrated Control and Protection Systems (ICPS), this distinction does not make much sense. In this lecture, we discuss these issues from distribution system perspective. In the next lecture, a transmission system perspective will be discussed. 3.2 System Protection Relays Consider a medium voltage distribution system having local generation (e.g., captive power generation) as shown in fig 3.2 which is also synchronized with the grid. During grid disturbance, if plant generators are not successfully isolated from the grid, they also sink with the grid, resulting in significant loss in production and damage to process equipments. The following relays are used to detect such disturbances, its severity and isolate the inplant system from the grid. Underfrequency and over frequency relays. Rate of change of frequency relays. Under voltage relays. Reverse power flow relays. Vector shift relays. 3.2 System Protection Relays 3.2.1 Underfrequency Relay and Rate of Change of Frequency Relay In case of a grid failure (fig. 3.3), captive generators tend to supply power to other consumers connected to the substation. The load-generation imbalance leads to fall in frequency. The underfrequency relay R detects this drop and isolates local generation from the grid by tripping breaker at the point of common coupling. After disconnection from the grid, it has to be ascertained that there is load-generation balance in the islanded system. Because of the inertia of the machines, frequency drops gradually. To speed up the islanding decision, rate of change of frequency relays are used. 3.2.2 Undervoltage Relay Whenever there is an uncleared fault on the grid close to the plant, the plant generators tend to feed the fault, and the voltages at the supply point drops. This can be used as a signal for isolating from the grid. 3.2.3 Reverse Power Relay

Distribution systems are radial in nature. This holds true for both utility and plant distribution systems. If there is a fault on the utility's distribution system, it may trip a breaker thereby isolating plant from the grid. This plant may still remain connected with downstream loads as shown in fig 3.4 and 3.5. Consequently, power will flow from the plant generator to these loads. If in the prefault state, power was being fed to the plant, then this reversal of power flow can be used to island the plant generation and load from the remaining system. This approach is useful to detect loss of grid supply whenever the difference between load and available generation is not sufficient to obtain an appreciable rate of change of frequency but the active power continues to flow into the grid to feed the external loads. Example In fig 3.4, consider that the plant imports at all times a minimum power of 5 MW. Studies indicate that for various faults in utility side, minimum power export from the plant generator is 0.5 MW. Deduce the setting of reverse power relay. If the plant generator is of 50 MW capacity, what is likelihood of underfrequency or rate of change of frequency relay picking up on such faults? Ans: Reverse power flow relay can be set to 0.4 MW. Since minimum reverse power flow is 1% of plant capacity, it is quite likely, that utility disconnection may not be noticed by underfrequency or the rate of change of frequency relays. Vector shift relays and system protection schemes in transmission systems will be discussed in more details in later lectures. 3.3 Lightning Protection Many line outages result from lightning strokes that hit overhead transmission lines. Lightning discharges normally produce overvoltage surges which may last for a fraction of second and are extremely harmful. The line outages can be reduced to an acceptable level by protection schemes like installation of earth wires and earthing of the towers. Lightning overvoltages can be classified as follows:

Induced overvoltages which occur when lightning strokes reach the ground near the line. Overvoltages due to shielding failures that occur when lightning strokes reach the phase conductors. Overvoltages by back flashovers that occur when lightning stroke reaches the tower or the shield wire. The most commonly used devices for protection against lightning surges are the following: Shielding by earth wires: Normally, transmission lines are equipped with earth wires to shield against lightning discharges. The earthwires are placed above the line conductor at such a position that the lightning strokes are intercepted by them. In addition to this, earthing of tower is also essential. Lightning Arrestors: An alternative to the use of earthwire for protection of conductors against direct lightning strokes is to use lightning arrestors in parallel to insulator strings. Use of lightning arrestors is more economical also. ZnO varistor is commonly used as lightning arrestor because of its peculiar resistance characteristic. Its resistance varies with applied voltage, i.e, its resistance is a nonlinear inverse function of applied voltage. At normal voltage its resistance is high. But when high voltage surges like lightning strokes appear across the varistor, its resistance decreases drastically to a very low value and the energy is dissipated in it, giving protection against lightning. Review Questions 1. Describe various system protection relays in use. 2. What are the functions of an underfrequency relay? 3. Explain the functioning of reverse power flow relay. 4. How transmission lines are protected against lightning? 5. Explain the functioning of ZnO varistor. Recap In this lecture we have learnt the following: Dynamics in power systems. Various system protection relays like underfrequency relays, rate of change of frequency relays, reverse power flow

relay, under voltage relay etc. Lightning protection.