P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

Similar documents
NGR. Guided Wave Radar Level Transmitter

Online data sheet FFUS15-1N1IO FFU FLOW SENSORS

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Operating Instructions for Microwave Level Switch. Model: LNM

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Pressure transmitter For sanitary applications Model SA-11

Electronic Pressure Switch Type MEP

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

The transducer component converts the measured signal and displays the actual value.

Technical Information Smartec CLD18

Pharma Temperature Sensor G3/8"

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Valve Island with Electronic I/O

Digital flow ELEMENT transmitter for continuous flow measurement

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

Inductive Conductivity Meter ILM

ph or ORP Transmitter

Digital conductivity transmitter

Technical Information Memosens CLS82D

Continuous Level Sensor NSL-M

Continuous Level Sensor NSL-M-00

DS 500/DT 500 Laser sensor measures distances to 18 m on black material in proximity mode

INSERTION paddle wheel flowmeter for continuous flow measurement

Pharma Temperature Sensor G3/8"

Electromagnetic Flow Transmitter

Magnetic-Inductive flow Meter fmi

LFP Cubic. Flexible up to the probe tip

Digital inductive conductivity transmitter

PHOTOELECTRIC SENSORS. Online data sheet

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Conductivity Transmitter

Level transmitters Series LTDR TDR guided radar level transmitter for liquids and solids

Technical Information Smartec CLD18

Electronic temperature switch with display Model TSD-30

Digital flow ELEMENT transmitter for continuous flow measurement

Temperature Sensor for Build-In System G3/8" FLEXadapt

Temperature Sensor for Build-In System G3/8" FLEXadapt

W 23-2: Focussing on what is essential and economic

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Pharma-Temperature Sensor M12 hygienic

Temperature Sensor Tri-Clamp

Level and Pressure. Product Information. Vibrating level switches

Conductivity sensor for hygienic applications

Temperature Sensor Tri-Clamp

Temperature Sensor with G1/2" hygienic

Temperature Sensor with M12 hygienic

INLINE flowmeter for continuous flow measurement

P r o d u c t O v e r v i e w. Pressure- and Level Measurement. Pressure and Level Sensors for Factory Automation Applications

INLINE flowmeter for continuous flow measurement

FLOWave SAW-Flowmeter

Temperature Sensor with M12 hygienic

Relative and absolute pressure transmitter type 528

Resistance thermometer Model TR31, miniature design

Online data sheet. WTB4S-3P1132V W4S-3 Inox MINIATURE PHOTOELECTRIC SENSORS


LFT level sensor - the all-round talent with TDR technology

Online data sheet VT12T-2P410 V12-2 CYLINDRICAL PHOTOELECTRIC SENSORS

Contrast Sensors. SICK The pioneer in contrast sensors for more than 60 years

Online data sheet. MLG05S-0895A10802 MLG-2 Prime MEASURING AUTOMATION LIGHT GRIDS

GWR2 Installation guide: Guided Wave Radar

Product description. At a glance. performance in a metal housing coating available Precise autocollimation optics. sensors

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

CombiTemp TCR6 Standard RTD temperature sensor

DS500/DT500 Laser sensor measures distances to 30 m on black material in proximity mode

High-quality pressure transmitter For general industrial applications Model S-10

Micropulse BTL-SF filling level sensor

Pharma Temperature Sensor TFP-EX

Capacitive Limit Switch Pharma NCS

Electronic Temperature Transmitters

Flush pressure transmitter For viscous and solids-containing media Model S-11

Magnetic Inductive Flow Sensor induq

Product description. At a glance. IP 69K-rated cylindrical photoelectric sensors in M18 stainless steel housing Resistant to all common cleaning

Online data sheet. PBSH-CB010ST1S0BMA0Z PBS Hygienic PRESSURE SENSORS

Capacitive Limit Switch Pharma NCS

Liquiphant T FTL20H. Technical Information

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

BATCHFLUX 5500 C Technical Datasheet

Resistance thermometer Model TR30, compact design

Capacitive Limit Switch Pharma NCS

ED701 General Industry Pressure Transmitter

V 18 Laser No frills performance: long ranges, high speeds with precision

INLINE flowmeter for continuous flow measurement

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Paddle wheel flow controller for On/Off control

Magnetic Inductive Flow Sensors induq. Series VMI

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

Online data sheet WSE9LC-3P2436A00 W9L-3

Resistance thermometer Model TR30, compact design

Temperature Sensor without thread

Screw-in resistance thermometers with plug connector

A finger on the pulse of time

PI2794. Flush pressure sensor with display. 1 alphanumeric display 4-digit 2 status LEDs 3 programming button. Made in Germany

Technical Information Nivector FTC968, FTC968Z

Digital flowmeter for continuous flow measurement

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Digital flowmeter for continuous flow measurement

Digital flow transmitter for continuous flow measurement

Miniature resistance thermometer Model TR33, thread-mounted

Transcription:

P R o D u c T I n F o R m at I o n TDR Level Sensor The clean solution

Level sensors The clean solution Product description The is a hygienic level sensor for liquids using TDR technology a process for determining the time of flight of electromagnetic waves. The time difference between the sent pulse and the reflected pulse is used to generate a level signal, both as a continuous value (analog output) and a freely positionable switching point (switching output). The use of robust FDA-compliant materials like stainless steel in an EHEDG-certified design means that the guarantees optimal, unrestricted cleaning, even for the highest hygiene requirements. Its modular connection system allows simple and flexible installation in any application. Thanks to high temperature and pressure resistance, unrestricted use is possible under CIP and SIP conditions. The communication capability via IO-Link to the superordinate control units rounds off the profile. At a glance Level monitoring in hygienic applications Manually cutable monoprobe up to 2,000 mm long with Ra 0.8 µm Process temperature up to 150 C, process pressure up to 16 bar CIP/SIP resistant High enclosure rating IP 67 and IP 69K Interchangeable hygienic process connections 3-in-1: combined display, analog output and binary output Analog output 4 ma 20 ma / 0 V 10 V, switchable, plus two binary outputs Your benefits Robust design increases service life High flexibility due to retractable protype EL - CLASS I NOVEMBER 2010 Additional information Detailed technical data 3 be and interchangeable connection concept Cost savings thanks to multiple output signals: one system for level detection and continuous level monitoring Maintenance-free and quick to commission, saving time and costs No calibration or recalibration required for commissioning, thus saving time and costs Type code....................... 5 Ordering information 5 Dimensional drawing 6 Connection type / diagram......... 6 Recommended accessories 7 Installation instructions............ 8 2 L e v e l s e n s o rs S I C K

Level sensors Detailed technical data Features Medium Fluids Measurement Switch, continuous Probe length 300 mm... 2,000 mm Process pressure 1 bar... +16 bar Process temperature 20 C... +150 C EHEDG approval l Gost approval l RoHS certificate l WHG certificate In preparation Performance Accuracy 1) ± 5 mm Reproducibility 1) < 2 mm Resolution < 2 mm Dielectricity constante 5 Conductivity No limitation Inactive area at process connection 2) 25 mm Inactive area at probe end 1) 10 mm 1) With water under reference conditions. 2) With parameterized tank with water under reference conditions, otherwise 40 mm. Mechanics Wetted parts 316L (Ra 0,8 µm), PEEK Process connection G 3/4 (hygienic process connectors with adapter for G 3/4, see accessories), 3/4" NPT Housing material 303 Max. probe load 6 Nm Accuracy diagram with parameterized tank Measuring accuracy in mm 0 L 25 Accuracy diagram without parameterized tank Measuring accuracy in mm 0 L 50 Inactive area 5 05 10 20 25 180 L 10 Probe length in mm 5 0 5 10 20 40 180 L 10 Probe length in mm L e v e l s e n s o r s S I C K 3

Level sensors Electronics Supply voltage 1) 12 V DC... 30 V DC Power consumption 75 ma at 24 V without output load Initialisation time 2 s Protection class III Electrical connection M12x1, 5-pin Signal output 1) Analog output 4 ma... 20 ma, 0 V... 10 V automatic switching to a current or voltage output depending on the load. 1 PNP transistor output (Q1) and 1 PNP/NPN transistor output (Q2) switchable. Hysteresis 2) Min. 2 mm, free adjustable Signal voltage HIGH Q1/2 Vs - 2 V Signal voltage LOW Q1/2 2 V Output current Q1/2 < 100 ma Inductive load Q1/2 < 1 H Capacative load Q1/2 < 100 nf Response time < 400 ms Enclosure rating IP 67: EN 60529, IP 69K: EN 40050 Temperature drift: < 0.1 mm/k Output load 4 ma 20 ma: < 500 Ohm at Uv > 13,5 V 4 ma 20 ma: < 400 Ohm at Uv > 12 V 0 V 10 V: > 750 Ohm at Uv 14 V Lower signal level QA 3.8 ma... 4 ma / 0 V Upper signal level QA 20 ma... 20.5 ma / 10.5 V EMC EN 61326-1:2006, 2004/108/EG Interference resistance EN 61000-6-2:2005 Interference emission EN 61000-6-4:2007 1) All connections are polarity protected. All outputs are overload and short-circuit protected. 2) Min. 2 mm, free adjustable. Ambient data Ambient temperature, operation 20 C... +60 C Ambient temperature, storage 40 C... +80 C 4 L e v e l s e n s o r s S I C K

Level sensors Type code Probe length in mm 0300 300 mm (steps of 10 mm) 2000 2000 mm Process connection and probe design G G 3/4 A (connection for hygienic adapters, see accessories), probe in 316L N 3/4" NPT, probe in 316L Housing, display, electrical connection 1 Stainless steel housing with PMMA viewing window, display, M12x1, 5-pin 2 Stainless steel housing without viewing window, display, M12x1, 5-pin 3 Stainless steel housing without viewing window according to 3-A guidelines, display, M12x1, 5-pin Signal output M Configurable current or voltage output Switching output B Q1: PNP fix; Q2: PNP or NPN configurable - N M B Ordering information The part numbers below show a selection of our common configurations and represent only an extract of the product portfolio. Signal output: 1x PNP+1x PNP/NPN + 4 ma 20 ma / 0 V 10 V Process connection: G 3/4 A Process temperature: 20 C... +150 C Process pressure: 1 bar... +16 bar Housing, display, electrical connection: Stainless steel housing with PMMA viewing window, display, M12x1, 5-pin Enclosure rating: IP 67, IP 69K Probe length Model name Part No. 300 mm 0300-G1NMB 1053288 400 mm 0400-G1NMB 1052069 500 mm 0500-G1NMB 1052070 600 mm 0600-G1NMB 1052071 700 mm 0700-G1NMB 1052072 800 mm 0800-G1NMB 1052073 900 mm 0900-G1NMB 1052074 1,000 mm 1000-G1NMB 1052075 1,100 mm 1100-G1NMB 1052076 1,200 mm 1200-G1NMB 1052077 1,300 mm 1300-G1NMB 1052078 1,400 mm 1400-G1NMB 1052079 1,500 mm 1500-G1NMB 1052080 1,600 mm 1600-G1NMB 1052081 1,700 mm 1700-G1NMB 1052082 1,800 mm 1800-G1NMB 1052083 1,900 mm 1900-G1NMB 1052084 2,000 mm 2000-G1NMB 1052085 L e v e l s e n s o r s S I C K 5

Level sensors Dimensional drawing 54 ( 2.13) 77 (3.03) 38 (1.50) 123 (4.84) 36 (1.42) M12x1 22 (0.87) L IA IAE M G 3/4 A 3/4 NPT 7 ( 0.28) M: Measuring range L: Probe length IA: Inactive area at process connection 25 mm (0.79") / 40 mm (1.58") IAE: Inactive area at probe end 10 mm (0.39") All dimensions in mm (inch) Connection type / diagram 1 L + : Supply voltage, brown 2 QA: Analog current-/voltage output, white 3 M: Ground, OUT- for current-/voltage output, blue 4 C/Q1: Switching output 1, PNP/IO-Link-communication, black 5 Q2: Switching output 2, PNP/NPN, grey 6 L e v e l s e n s o r s S I C K

Level sensors Recommended accessories Flanges, flange plates Brief description Process connection Model name Part No. Coupling (DIN 11864-1) DN 25 form A with union nut BEF-HA-641D25-1 2058795 Flange (DIN 11864-2) DN 25 form A BEF-HA-642D25-1 2058823 Clamp (DIN 11864-3) DN 25 form A BEF-HA-643D25-1 2058821 Hygienic process connection adapter for with G 3/4 Conical coupling (DIN 11851) DN 25 with union nut Conical coupling (DIN 11851) DN 40 with union nut BEF-HA-851D25-1 2058138 BEF-HA-851D40-1 2058139 Conical coupling (DIN 11851) DN 50 with union nut BEF-HA-851D50-1 2058141 Tri-Clamp 1'' and 1 ½'' BEF-HA-TCLI10-1 2058808 Tri-Clamp 2'' BEF-HA-TCLI20-1 2058824 Hygienic adapter for with G 3/4 and 3-A housing Tri-Clamp 1 and 1 ½ with leakage indication port according to 3-A guidelines BEF-HA-TCLI10-3 2058851 Plug connectors and cables Brief description Model name Part No. Power supply cable IP 69K, with 5-pin M12 socket (straight) / open end, 2 m, PVC DOL-1205-G02MN 6028140 Power supply cable IP 69K, with 5-pin M12 socket (straight) / open end, 5 m, PVC DOL-1205-G05MN 6028141 Power supply cable IP 69K, with 5-pin M12 socket (straight) / open end, 10 m, PVC DOL-1205-G10MN 6028142 L e v e l s e n s o r s S I C K 7

Level sensors Installation instructions Installation in a metal tank D A Installation in nozzle: Diameter D DN 25 Distance tank wall/tank bottom: A 50 mm B 15 mm Distance to other tank fittings 100 mm B In a 3-A compliant installation, the neck height shouldn t be bigger than the neck diameter. Tank, pipe and process connection (tank side) should follow the guidelines and applicable standards for hygienic design such as roughness of wet parts Ra< = 0.8 μm. Installation in a metal immersion tube or metal bypass D DN 40 Distance to bypass/tank bottom B 15 mm D B center Centering: To prevent contact between the probe and the bypass pipe during oscillations, the probe should be centered according to its length and depending on the diameter of the bypass pipe. To do this, it is necessary to insert one or two centering pieces (see accessories). The use of in bypass and immersion tube systems are not hygienic, because these systems are very difficult to clean. Tank welds can affect the measurement accuracy. 8 L e v e l s e n s o r s S I C K

Level sensors notes L e v e L S e n S o R S S I c K 9