Retro-reflective ultrasonic sensor. Dimensioned drawing

Similar documents
Electrical connection

Electrical connection

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Leuze electronic. Throughbeam photoelectric sensor. Dimensioned drawing. Electrical connection. Accessories: ISO 9001 IP 67

Laser contrast scanner. Dimensioned drawing

Electrical connection

Diffuse reflection light scanner with background suppression. Dimensioned drawing

Leuze electronic. 3 Series. Product description

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

ULTRASONIC. Distance and Proximity Sensors. Series UFA-150, UFA-200. Key-Features:

Optical laser distance sensors. Dimensioned drawing

Optical laser distance sensors. Dimensioned drawing

Diffuse reflection light scanner with background suppression. Dimensioned drawing. Electrical connection. see remarks!

Sensors for PET, glass and foil PRODUCT DESCRIPTION

Retro-reflective sensors for bottles and tape. Dimensioned drawing

Laser light scanner with background suppression. Dimensioned drawing

Compact Sensors for Retro-reflective Applications

ULTRASONIC. Ultrasonic Distance- and Proximity Sensors. UFA-1500 Series. Key features:

Optical laser distance sensors. Dimensioned drawing

ULTRASONIC. Distance and Proximity Sensors. Series UFA-150, UFA-200. Key-Features:

Throughbeam photoelectric sensors. Dimensioned drawing. Transmitter/receiver Optical axis LED yellow 90 turning connector. Electrical connection

Inductive switches. Dimensioned drawing

Ultrasonic sensors. Reliable on almost all surfaces. UT 20 from Page 548. UT 12 from Page 564. UT/UM 18 from Page 568

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

Laser diffuse reflection sensor with background suppression. Dimensioned drawing

ucs ultrasonic sensors Extract from our online catalogue: Current to:

ULTRASONIC. Ultrasonic Distance and Proximity Sensors. UFA-1500 Series. Key features:

MLV40 Series Miniature Sensors

Inductive Linear Position Sensor LI800P0-Q25LM0-LIU5X3-H1151

MLV12 Series Dura-Vue TM Sensors

Diffuse reflection light scanner with background suppression. Dimensioned drawing

zws-15/cd/qs Extract from our online catalogue: Current to:

Retro-reflective sensors with polarizing filters, M18 housing

Inductive linear position sensor LI400P0-Q25LM0-LIU5X3-H1151

Inductive angle sensor. 4-wire, analog output. Ri360P1-QR14-ELiU5X2-0,3-RS5. Rectangular, plastic Many mounting possibilities

Sensor technologies Distance measuring sensors Series SM6-AL. Brochure

ULTRASONIC. Ultrasonic Distance and Proximity Sensors. Series UPR-A ATEX. Key features:

Inductive Linear Position Sensor IO-Link LI100P0-Q25LM0-ELIUPN8X3-H1151

USA series. Capable of long-distance measurement Built-in teaching function for simple operation and highlyaccurate

Inductive Linear Position Sensor LI200P0-Q25LM0-HESG25X3-H1181

V 18 Laser No frills performance: long ranges, high speeds with precision

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

Ultrasonic retroreflective

bks-3/ciu Extract from our online catalogue: Current to:

Polymer Electric. Product information. Ultrasonic Industrial Sensor USi

DB 14B. Double Sheet Testing Unit. Phone: Fax: Web: - DE 00-05/

Ultrasonic Diffuse, Dual Transistor Outputs Type M18 and M30

Retro-reflective photoelectric sensors with polarization filter. Dimensioned drawing

M18 DC Photoelectric Switches FA

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Smart Power Relay E I...

Ultrasonic level meters ULM 70

Distance Sensors BOD 26K.... with optional Master-Slave-Mode

V 12-2 Miniature photoelectric switches: innovations in M12 housings

44.5 mm mm. Long-range Models. 2 m. 5-pin Mini QD. Q45UBB63DAQ6 20, 40, 160 or 640 ms Q45UBB63DAC Yes. 5-pin Euro QD.

Sensor technologies Distance measuring sensors Series SM6-AL. Brochure

Inductive Angle Sensor With Analog Output RI360P1-QR14-ELIU5X2

Drive electronics pq11

Trip amplifier, 1 channel

RK 46C VarOS. teach me. Retro-refl ective photoelectric sensor with powerful light-band.

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

laser sensors through-beam sensor switching output / analog output high precision repeatability

LINEAR POTENTIOMETER. LZW Series. Key-Features:

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

Inductive sensor BI2-Q4,7-AN6X

10 SERIES. power reserve. Measuring and switching distance sensors with high object tolerance.

WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R

Technical data. General specifications. Transducer frequency Indicators/operating means

Inductive switches. Dimensioned drawing

Absolute encoders - analog Blind hollow shaft ø12 mm Magnetic single- or multiturn encoders 12 bit ST / 16 bit MT

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

SI-JET Series SI-JET3-CON8 A-LAS-M C A-LAS-M C. Design. SI-JET Series Spray Jet Control Sensors. Product name:

Technical data. General specifications. Transducer frequency Indicators/operating means

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

Original operating instructions Fail-safe inductive sensor GG507S

Application Examples. Features. Ultrasonic Displacement Sensor E4PA-N. Now, more advanced with a new mutual interference prevention function.

USi Product Presentation. Mayser Ultrasonic Industrial Sensor USi

V 18 Laser No frills performance: long ranges, high speeds with precision

PD30ETD10xxSA. Photoelectrics, Diffuse reflective. Main features. Description

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Diameter (mm) Sinking. Sourcing. Drawing # Wiring Diagram # of LEDs. Ni75U-CP80-AN6X A M

U-GAGE Q45U Long-Range Ultrasonic Sensors

Retro-reflective photoelectric sensors with polarization filter for bottles. Dimensioned drawing

Technical data. General specifications. Measurement range min max. 360

E2S World's Smallest Square Sensor with Built-in Amplifier

W 23-2: Focussing on what is essential and economic

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

CS Colour sensors: When it s the colour that counts

Easy to replace. A pigtailed type sensor with connector (CY- -J), which is easy to replace, is also available. Environment resistant

Ultrasonic Sensors. Special-Sensors for. Automation. Level control Distance measurement Monitoring of all materials Waterproof Teach-in function

Drive Electronics pq11

D-LAS Series D-LAS2-LC-... Design. D-LAS Series Laser Digital Light Barriers. Product name: Transmitter: D-LAS2-LC-T.

A finger on the pulse of time

Capacitive sensors. Versatile, contactless, durable Edition 2012/2013

Measurement range. Resolution 0.03 % ( ); 0.1 % ( ) Repeatability ±0.03 % ( ); ±0.1 % ( )

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable

DS 500/DT 500 Laser sensor measures distances to 18 m on black material in proximity mode

Transcription:

Specifications and description RKU 418 RM/WM Retro-reflective ultrasonic sensor Dimensioned drawing mm 7mm - 3 V DC Colour and transmission independent detection of objects Switching behaviour largely independent of surface properties No dead zone Distance teachable Small construction ctive surface Indicator diode Q1 We reserve the right to make changes USDS_12gb.fm ccessories: U L US C LISTED IEC 947... IEC 947... IP 65 (available separately) Mounting systems Cable with M12 connector (K-D ) Electrical connection Leuze electronic GmbH + Co. KG In der raike 1 D-73277 Owen Tel. +49 () 721 573- info@leuze.de www.leuze.com RKU 418RM/P- -S12-5 RKU 418WM/P- -S12-5

RKU 418 RM/WM Specifications Ultrasonic specifications RKU 418 --S12 RKU 418-7-S12 Operating range 1) mm 7mm djustment range 1 2mm 35 75mm Dead zone mm in front of reflector 5mm in front of reflector surface surface Ultrasonic frequency khz khz Typ. opening angle see diagrams Direction of beam RKU 418RM/P : straight, RKU 418WM/P : angular, 9 Temperature drift ±.17%/K Timing Switching frequency 1Hz 5Hz Response time 5ms 1ms Delay before start-up ms Electrical data Operating voltage U 3V DC (incl. ± 1% residual ripple) Residual ripple ± 1% of U ias current m Switching output PNP transistor Function characteristics switching in case of object recognition Output current 15m Switching range adjustment teach-in, teach input (pin 2) connected to GND for 3s Indicators Yellow LED output activated Flashing yellow LED teaching procedure Mechanical data Housing metal / CuZn Weight 5g Connection type M12 connector, plastic, 4-pin Environmental data mbient temp. (operation/storage) -25 C +7 C/- C +85 C Protective circuit 2) 1, 2, 3 VDE safety class III Protection class IP 65 Standards applied IEC 947-5-2 Fitting position any 1) For the complete temperature range, measured object xmm 2) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection Tables Diagrams RKU 418 --S12 Typ. response behaviour (object xmm) 3 1-1 - -3 5 15 25 35 45 RKU 418-7-S12 Typ. response behaviour (object xmm) 1 8 - - - -8-1 1 3 5 7 9 11 13 x C D Operating range djustment range Reflector Dead zone Order guide Designation Part No. Range: mm, direction of beam: straight RKU 418RM/P-5--S12 5 38637 Range: mm, direction of beam: 9 RKU 418WM/P-5--S12 5 38638 Range: 7mm, direction of beam: straight RKU 418RM/P-3-7-S12 5 38641 Range: 7mm, direction of beam: 9 RKU 418WM/P-3-7-S12 5 38642 pproved purpose: The retro-reflective ultrasonic sensors are ultrasonic sensors for acoustic, contactless detection of objects. Teaching procedure: Position reflector at the desired switching distance. Connect teach input (pin 2) to GND for 3s. Reconnect teach input to +U or leave unconnected; switching output is taught. Temperature drift ±.17%/K RKU 418RM/P- -S12-5 81 RKU 418WM/P- -S12-5

HRTU 418 RM/WM Ultrasonic sensors Dimensioned drawing 3 mm 1 7mm - 3 V DC Colour and transmission independent detection of objects Switching behaviour largely independent of surface properties Distance teachable Small construction ctive surface Indicator diode Q1 We reserve the right to make changes USDS_1gb.fm ccessories: U L US C LISTED IEC 947... IEC 947... IP 65 (available separately) Mounting systems Cable with M12 connector (K-D ) Electrical connection Leuze electronic GmbH + Co. KG In der raike 1 D-73277 Owen Tel. +49 () 721 573- info@leuze.de www.leuze.com HRTU 418RM/P- -S12-5 HRTU 418WM/P- -S12-5

HRTU 418 RM/WM Specifications Ultrasonic specifications HRTU 418 --S12 HRTU 418-7-S12 Operating range 1) 3 mm 1 7mm djustment range 5 mm 15 7mm Ultrasonic frequency khz khz Typ. opening angle see diagrams Resolution 1mm Direction of beam HRTU 418RM/P : straight, HRTU 418WM/P : angular, 9 Reproducibility ± 1mm Switching hysteresis 1mm Temperature drift ±.17%/K Timing Switching frequency 1Hz 5Hz Response time 5ms 1ms Delay before start-up ms Electrical data Operating voltage U 3V DC (incl. ± 1% residual ripple) Residual ripple ± 1% of U ias current m Switching output PNP transistor Function characteristics switching in case of object recognition Output current 15m Switching range adjustment teach-in, teach input (pin 2) connected to GND for 3s Indicators Yellow LED output activated Flashing yellow LED teaching procedure Mechanical data Housing metal / CuZn Weight 5g Connection type M12 connector, plastic, 4-pin Environmental data mbient temp. (operation/storage) -25 C +7 C/- C +85 C Protective circuit 2) 1, 2, 3 VDE safety class III Protection class IP 65 Standards applied IEC 947-5-2 Fitting position any 1) For the complete temperature range, measured object xmm 2) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection Tables Diagrams HRTU 418 --S12 Typ. response behaviour (object xmm) 3 1-1 - -3 5 15 25 35 45 HRTU 418-7-S12 Typ. response behaviour (object xmm) 1 8 - - - -8-1 1 3 5 7 9 11 13 x C D Operating range djustment range Object Dead zone Order guide Operating range: 3 mm, direction of beam: straight Operating range: 3 mm, direction of beam: 9 Operating range: 1 7mm, direction of beam: straight Operating range: 1 7mm, direction of beam: 9 Designation Part No. HRTU 418RM/P-5--S12 5 38635 HRTU 418WM/P-5--S12 5 38636 HRTU 418RM/P-3-7-S12 5 38639 HRTU 418WM/P-3-7-S12 5 386 pproved purpose: The ultrasonic sensors are used for acoustic, contactless detection of objects. Teaching procedure: Position measured object at the desired measurement distance. Connect teach input (pin 2) to GND for 3s. Reconnect teach input to +U or leave unconnected; switching output is taught. Temperature drift ±.17%/K HRTU 418RM/P- -S12-5 81 HRTU 418WM/P- -S12-5

HRTU 418 Ultrasonic distance sensors Dimensioned drawing 5 3mm 15 1mm - 3 V DC Ideal for detection of levels of liquids, bulk materials, transparent media, Distance information largely independent of surface properties PC-configuration software for configuring sensor and analogue output Up to 1 devices can be synchronised via the SYNC input Indicator diodes Q1 We reserve the right to make changes USDS_2gb.fm ccessories: U L US C LISTED IEC 947... IEC 947... IP 67 (available separately) Mounting systems Cable with M12 connector (K-D ) "USDS-Config" configuration software (free download from www.leuze.com) PGU 1 (programming unit) Electrical connection Leuze electronic GmbH + Co. KG In der raike 1 D-73277 Owen Tel. +49 () 721 573- info@leuze.de www.leuze.com HRTU 418M/V-5x1-3-S12-5 HRTU 418M/V-3x1-1-S12-5

HRTU 418 Specifications Ultrasonic specifications HRTU -5x1-3 HRTU -3x1-1 Operating range 1) 5 3mm 15 1mm Ultrasonic frequency khz khz Opening angle 6 Resolution 1mm bsolute measurement accuracy ± 2.5% of the measurement range end value Reproducibility ± 1mm ± 2mm Switching hysteresis 1mm 1mm Timing Switching frequency (min.) 2) 5Hz 4Hz Response time (max.) 2) 1ms 1ms Delay before start-up 28ms 28ms Electrical data Operating voltage U 3V DC (incl. ± 1% residual ripple) Residual ripple ± 1% of U ias current m Switching output analogue Current output only HRTU -x1- Output current 4 m Load resistor R L = 3Ω Characteristic curve ascending Voltage output only HRTU -x31- Output voltage 1V Load resistor R L 5Ω Characteristic curve ascending Indicators Yellow LED object detected Mechanical data Housing metal / CuZn Weight 5g Connection type M12 connector, plastic, 4-pin Environmental data mbient temp. (operation/storage) -25 C +7 C/- C +85 C Protective circuit 3) 1, 2, 3 VDE safety class III Protection class IP 67 Standards applied IEC 947-5-2 Fitting position any 1) For the complete temperature range, measured object 1x1mm 2) Can be configured up to 3 times faster using "USDS-Config" 3) 1=short-circuit and overload protection, 2=no polarity reversal protection, 3=wire break and inductive protection pproved purpose: The ultrasonic distance sensors are used for acoustic, contactless detection of objects. Order guide Designation Part No. Current output HRTU 418M/V-51-3-S12 5 36259 Current output HRTU 418M/V-31-1-S12 5 362 Voltage output HRTU 418M/V-531-3-S12 5 616 Voltage output HRTU 418M/V-331-1-S12 5 618 Tables Diagrams HRTU -5x1-3 Typ. response behaviour (object 1x1mm) 5 3 1-1 - -3 - -5-1 3 5 HRTU -3x1-1 Typ. response behaviour (object 1x1mm) 1 1 8 - - - -8-1 -1 1 3 5 7 9 11 13 15 x Synchronisation: Mutual interference is excluded by connecting the sensors with the SYNC input. Configuration software "USDS-Config" The configuration software runs under Windows 95/98/ NT//XP and offers the following features: Configuration of multiplex operation Configuration of the sensor (attenuation, switching frequency, response time) djustment of the switching output (start/end of switching range, hysteresis, object present yes/no) djustment of the analogue output Support of various languages HRTU 418M/V-5x1-3-S12-5 81 HRTU 418M/V-3x1-1-S12-5

HRTU 418 Ultrasonic sensors Dimensioned drawing 5 3mm 15 1mm - 3 V DC Ideal for detection of levels of liquids, bulk materials, transparent media, Distance information largely independent of surface properties PC-configuration software for configuring sensor and switching output Up to 1 devices can be synchronised via the SYNC input Start and end of switching range adjustable separately via PC End of switching range (only for 418M/P ) Indicator diodes Q1 Electrical connection We reserve the right to make changes USDS_1gb.fm IEC 947... IEC 947... IP 67 ccessories: (available separately) Mounting systems Cable with M12 connector (K-D ) "USDS-Config" configuration software (free download from www.leuze.com) PGU 1 (programming unit) Leuze electronic GmbH + Co. KG In der raike 1 D-73277 Owen Tel. +49 () 721 573- info@leuze.de www.leuze.com HRTU 418M/P-51-3-S12-5 HRTU 418M/P-31-1-S12-5

HRTU 418 Specifications Ultrasonic specifications HRTU -51-3 HRTU -31-1 Operating range 1) 5 3mm 15 1mm Ultrasonic frequency khz khz Opening angle 6 Resolution 1mm bsolute measurement accuracy ± 2.5% of the measurement range end value Reproducibility ± 1mm ± 2mm Switching hysteresis 1mm 1mm Timing Switching frequency (min.) 2) 5Hz 4Hz Response time (max.) 2) 1ms 1ms Delay before start-up 28ms 28ms Electrical data Operating voltage U 3V DC (incl. ± 1% residual ripple) Residual ripple ± 1% of U ias current m Switching output PNP transistor Function characteristics switching in case of object recognition Output current 15m Switching range adjustment potentiometer 27 Indicators Yellow LED output activated Mechanical data Housing metal / CuZn Weight 5g Connection type M12 connector, plastic, 4-pin Environmental data mbient temp. (operation/storage) -25 C +7 C/- C +85 C Protective circuit 3) 1, 2, 3 VDE safety class III Protection class IP 67 Standards applied IEC 947-5-2 Fitting position any 1) For the complete temperature range, measured object 1x1mm 2) Can be configured up to 3 times faster using "USDS-Config" 3) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection pproved purpose: The ultrasonic sensors are used for acoustic, contactless detection of objects. Order guide Designation Part No. HRTU 418M/P-51-3-S12 5 36257 HRTU 418M/P-31-1-S12 5 36258 Tables Diagrams HRTU -51-3 Typ. response behaviour (object 1x1mm) 5 3 1-1 - -3 - -5-1 3 5 HRTU -31-1 Typ. response behaviour (object 1x1mm) 1 1 8 - - - -8-1 -1 1 3 5 7 9 11 13 15 x Synchronisation: Mutual interference is excluded by connecting the sensors with the SYNC input. Configuration software "USDS-Config" The configuration software runs under Windows 95/98/ NT//XP and offers the following features: Configuration of multiplex operation Configuration of the sensor (attenuation, switching frequency, response time) djustment of the switching output (start/end of switching range, hysteresis, object present yes/no) djustment of the analogue output Support of various languages HRTU 418M/P-51-3-S12-5 81 HRTU 418M/P-31-1-S12-5

HRTU 418 RM/WM Ultrasonic sensors Dimensioned drawing We reserve the right to make changes USDS_13gb.fm rt. Nr. 518367-3 V DC 25 mm 5 7mm! Colour and transmission independent detection of objects! Switching behaviour largely independent of surface properties! Two mutually independent switching points! Distance teachable! Small construction IEC 947... IEC 947... IP 65 ccessories: (available separately)! Mounting systems! Cable with M12 connector (K-D ) ctive surface Indicator diode Q1, Q2 Electrical connection Leuze electronic GmbH + Co. KG In der raike 1 D-73277 Owen Tel. +49 () 721 573- info@leuze.de www.leuze.com HRTU 418 /52--S12-2 HRTU 418 /52-7-S12-2

HRTU 418 RM/WM Specifications Ultrasonic specifications HRTU 418 --S12 HRTU 418-7-S12 Operating range 1) 25 mm 5 7mm djustment range mm 75 7mm Ultrasonic frequency 3kHz khz Typ. opening angle see diagrams Resolution 1mm Direction of beam HRTU 418RM/P : straight, HRTU 418WM/P : angular, 9 Reproducibility ± 1mm Switching hysteresis 1mm Temperature drift ±.17%/K Timing Switching frequency 1Hz 5Hz Response time 5ms 1ms Delay before start-up ms Electrical data Operating voltage U 3V DC (incl. ± 1% residual ripple) Residual ripple ± 1% of U ias current m Switching output 2x PNP transistor Function characteristics switching in case of object recognition Output current Switching range adjustment 3m teach-in Q1: teach input (pin 2) connected to GND for 3 6s teach-in Q2: teach input (pin 2) connected to GND for 6 9s Indicators Yellow LED output Q1, output Q2 Flashing yellow LED teaching procedure Mechanical data Housing metal/brass nickel-plated Weight 5g Connection type M12 connector, plastic, 5-pin Environmental data mbient temp. (operation/storage) -25 C +7 C/- C +85 C Protective circuit 2) 1, 2, 3 VDE safety class III Protection class IP 65 Standards applied IEC 947-5-2 Fitting position any 1) For the complete temperature range, measured object xmm 2) 1=short-circuit and overload protection, 2=polarity reversal protection, 3=wire break and inductive protection Tables Diagrams HRTU 418 --S12 Typ. response behaviour (object xmm) 1 8 - - - -8-1 1 3 5 7 9 11 13 HRTU 418-7-S12 Typ. response behaviour (object xmm) 1 8 - - - -8-1 1 3 5 7 9 11 13 x C D Operating range djustment range Object Dead zone Order guide Operating range: 25 mm, direction of beam: straight Operating range: 25 mm, direction of beam: 9 Operating range: 5 7mm, direction of beam: straight Operating range: 5 7mm, direction of beam: 9 Designation Part No. HRTU 418RM/P-52--S12 51 916 HRTU 418WM/P-52--S12 51 917 HRTU 418RM/P-52-7-S12 51 918 HRTU 418WM/P-52-7-S12 51 919! pproved purpose: The ultrasonic sensors are used for acoustic, contactless detection of objects.! Temperature drift ±.17%/K HRTU 418 /52--S12-2 88 HRTU 418 /52-7-S12-2

HRTU 418 RM/WM Ultrasonic sensors Teach-in via input 1.Position measurement object at the desired distance. 2.The respective teach function is activated by applying GND to the teach input (pin 2). The teach event is signalled by slow flashing of the LEDs. Teach function Teach phase / duration of the teach signal LED Q1 LED Q2 Teach preparation / 3s off off switching output Q1 / 3 6s flashes off switching output Q2 C / 6 9s off flashes 3.To finish the teach event, disconnect the teach input from GND or switch it to +U after the desired time. If the teach event has not completed after 9s, it begins again with phase. 4. successful teach event is signalled by the end of the flashing. Error messages LEDs which continuously flash fast signal an unsuccessful teach event (sensor not ready): LED Q1 LED Q2 Error flashes rapidly switching state output Q2 teach switching output Q1 unsuccessful switching state output Q1 flashes rapidly teach switching output Q1 unsuccessful Remedy:! Disconnect sensor from voltage to restore the old values.! Repeat teach event