Bidirectional Ultrasonic Distance Measurement

Similar documents
Manifold Electronic Gauge. Model: KC-100B-1 Operation Manual

114-GB(cover,p1-12) 25/08/ :49 AM Page

INSTRUCTION MANUAL INF Fax: (503)

Instruction Manual. Self-Leveling Cross-Line Laser Level Model No and

QUAD 1000 OWNERS MANUAL OPERATION GUIDE

High Temperature InfraRed Thermometer with Laser Pointer

User s Manual. hand-held laser distance meter

LA-1010 User s Manual 3 in 1 Stud/Metal/AC Voltage Finder With Laser Line Level.

USER GUIDE. Mini InfraRed Thermometer with Laser Pointer MODEL 42500

USER MANUAL. Laser Distance Meter MODELS DT40M, DT60M, and DT100M

Laser Distance Finder Extech DT500

1 Symbols. 4 Foreseeable misuse Do not use the device as a laser pointer. Do not use the device in explosive or aggressive environments.

Operator's Manual. 10-in. Digital Multi-function LEVEL with Laser Trac. Model No

X2 LASER DISTANCE METER. Operating instruction

ed560l Laser Distance Meter User Manual

Laser LA-4P. Operating instructions

Pipe Laser Model No Instruction Manual

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Table of Contents. Makita LD050P 1

Table of Contents. Stabila LD 320 1

Laser Distance Finder Extech DT500

USER GUIDE. IR Thermal Scanner. Model IRT500

NOTE: Fully read and understand this manual before using this Digital Multimeter.

OVA-50 Optical Variable Attenuator User s Manual

Multi-beam Self-leveling Line Laser

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Revision 1.8 II WARANTY

DE EN FR IT ES RU PL DA NL NO SV

IR-829 Infrared Thermometer User Manual

LASER ENHANCED REVOLVER GRIP OWNER S MANUAL RED LASER GREEN LASER

1. Brief Introduction

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

USER'S GUIDE. EcoQuest International 310 T. Elmer Cox Drive Greeneville, TN (423) Setup. Operation. Specifications.

Beaming Optical Length Tester (BOLT)

A510S Operation Manual

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

Laser User Manual. Therapy Unit INTRODUCTION

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Dawson DSM150. Digital Light Meter User s Manual

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

IMPORTANT: Read Before Using. Operating/Safety Instructions 8601-RL

Model R2002. Instruction Manual. Infrared Thermometer. reedinstruments www.

Thermometer model 02059

LA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS

Revision 1.4 II. Warranty

ADAE portable X ray machine Operation manual

Digital clamp meter AX-3550

3x Magnification. Digital Zoom to 6x. CAUTION: Do not point Infrared Emitter directly into eye at close range.

DMM8900 SERIES USERS MANUAL

Non-contact Forehead IR Thermometer

SlimScan BT Users Manual

P10 LASER DISTANCE MEASURE. IMPORTANT: Read before Using

2011 / Circuit Tracer

INSTRUCTION MANUAL DW089-XE 3 BEAM LINE LASER

ProfiScale MULTI Multimeter

Important safety instructions

UT232. Operating Manual. Digital Power Clamp Meter

INSTRUCTION MANUAL MODEL SAS RS-7 LASER DISTANCE METER

User Guide. Heavy Duty Psychrometer + IR Thermometer. Model HD550

MT2 and MT4 Noncontact Thermometer Berührungsloses Thermometer Thermomètre sans Contact Termómetro sin Contacto Termômetro sem Contato

Dawson DDM190. Digital Multimeter User s Manual

OPERATIONS MANUAL DP-110 IN-DUCT DIGITAL PSYCHROMETER TABLE OF CONTENTS

DE EN FR ECOLINE EL 609 BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI EXACTLY WHAT YOU NEED.

Instruction Manual TS

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

WS-7220U-IT 915 MHz Wireless Weather Station. Instruction Manual

OPERATION MANUAL INFRARED THERMOMETER FIRT 500

Model UT233 OPERATING MANUAL

Geotagger N3. User Manual (V1.0) Revised by Geosolve.be (Pol F. Gillard) with personal updates and help. Solmeta Technology Co.

Temp / RH / CO 2 Hand-Held Meter

16mm. inch. Sensor Beam

User s Guide. Model MA A AC Mini Clamp-on Meter

3B SCIENTIFIC PHYSICS

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

Diode Pointer Quick Start Guide

Operating Instructions GEMINI R

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

Model: &

MANUAL PCE-UT232

CLAMP-ON METER 670. User Manual

Digital Wireless Weather System

3B SCIENTIFIC PHYSICS

CONTENTS MS2033A. 1.Introduction Safety Information...01

600A Clamp Meters w/tightsight Display

Ior DIGITAL LEAKAGE CLAMP TESTER MCL-400IR INSTRUCTION MANUAL

HHMA2 DC / TRUE RMS AC NON-CONTACT MILLIAMMETER

Register your product and get support at AJ7010. User manual

Operating Manual MRL-101

INSTRUCTION MANUAL Vibration Meter

MINI. User s Guide. Manufactured by: BlissLights Phone: (888) MADE IN CHINA

Always there to help you. Register your product and get support at AJ3200. Question? Contact Philips.

1/4in. SHEET PALM SANDER

WIRELESS 915 MHz TEMPERATURE STATION Instruction Manual

High Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use.

DM-45 Digital Multimeter

Contents. Page English 1. French. Spanish. Reset of MIN/MAX records 915 MHz Reception Mounting Care and Maintenance Warranty Information

433 MHZ TEMPERATURE STATION Instruction Manual

Model R8001. Instructionn Manual. Laser Distance Meter. reedinstruments. www. com

USER'S MANUAL DMR-6700

Transcription:

Bidirectional Ultrasonic Distance Measurement Model: KC-200 Operation Manual

Bidirectional Ultrasonic Distance Measurement Model: KC-200 OVERVIEW KC-200 bidirectional ultrasonic distance measurement determines the distance to the object through electronic signals with high speed. The tool with built-in computer chip has the function of calculation of room area, volume and so on. The tool with excellent design owns multinomial patents. Its unique bidirectional dynamic measurement technology makes the effective measurement distance can reach to 30 meters. The tool has the function of long distance measurement. And it is easy to operate and clear to display. It is an ideal tool for building, decoration industries (for example, land agents, upholstery designers and craftsmen, etc) KC-200 bidirectional ultrasonic distance measurement is the Class II laser tool conforming to EN60825-1 safety rule. SAFETY INSTRUCTIONS Failure to follow the instructions listed below may cause personal injury. Read and understand all instructions prior to any operation. Do not remove any labels from the tool. Do not operate the tool with the presence of flammable/explosive gases. Do not operate the laser tool around the children or allow children to operate the laser tool, failure to do so will injure eyes of children. Do not stare into the laser beam. Do not project the laser beam directly into the eyes of others. Do not set up the tool at eye level or operate the tool on or near a reflective surface, as the laser beam could be projected into your eyes or the eyes of others. Do not observe the laser beam by using optical tools such as binoculars and magnifying glass. Remove the battery when storing the tool for an extended period of time in case of the deterioration of battery and its damage to the tool. Warning DANGER Class II Laser Product Maximum Power Output< 1mW Wavelength: 630-660nm Do not stare into beam! Avoid direct eye exposure! This tool emits a laser radiation! 1

Battery Safety Instructions Please remove the batteries when clean the product. Remove the batteries before long term storage Please install the batteries properly as the instructions of the positive and negative charges Please dispose the batteries properly. High temperature will cause explosions and do not burn the batteries. Strap insulated tape around the battery charges to avoid unsafe contacts with other objects.many countries have regulations regarding battery disposal.please follow the local regulations of battery disposing. TOOL COMPONENTS A. Ultrasonic sensor aperture B. Laser pointer C. Two row LCD---the data of upper line is the current measuring result, and the data of lower line is the memory/computing result D. BASE key: measurement base selection key. Keep pressing this key for 2s to shut the tool. E. M key: memory function key, memory the measurement result F. MODE key: mode transform key. Three circulation transform patterns: The length, area, volume, and the default state is length measurement. The unit will display environment temperature when keep pressing the key for 2 seconds. G. RM key: recall the memory data. Keep holding the key for more than 2 seconds to select measurement unit: British unit or the Metric unit. (the original unit is Metric unit) H. READ key: start and measuring key I. +/= key: addition key J. level vials ILLUSTRATION OF DISPLAY SCREEN 2

A.Length/area/volume mode indication (L=length;W=width;H=height) B.Plus C.Measuring base D.Memory E.Left measuring result F.Memory compute result G.Display when lack of electric quantity H.Right measuring result I.Square foot J.Cubic foot K. Meter/square meter/cubic meter OPERATION GUIDE Battery installation Open the battery compartment door on the back of the tool, and plug one 9 Volt block battery onto the battery connector and put the battery back to the compartment and close the door. Distance measurement Make the induction hole of the tool face against the measured object (e.g. the wall) and keep the tool vertical to the measured object; make sure the point of the level vial stands between the two lines of the level vial by adjusting the position of the unit. Press the READ key to start the tool, the instrument is ready to work. Press the READ key again to get the measured distance. There are left measuring and right measuring result respectively on the upper row. The addition of left measuring result and right measuring result will display on the lower portion meantime. The laser beam indicates the measured surface. 3

Keep pressing the READ key and move the tool to get the dynamical readings, and the measured distance will be displayed on upper portion of the screen Press the BASE key once to transform measurement base. Press the key every time and the base point are the following five ways in turn: starting from the middle then do bidirectional measurement starting from the left then measure to the right starting from the right then measure to the right, starting to the left then measure to the left starting from the right then measure to the left. The default state is for bidirectional measurement. Midpoint indication: At the mode of bidirectional measurement, when the unit detects the midpoint ( the distance of two sides is equal), the buzzer will sound. Meanwhile the central base symbol and two ultrasonic symbols on the display will twinkle. Unit transform: Keep pressing RM key for 2 seconds to select measurement unit: British unit or the Metric unit. (the original unit is Metric unit) Shut the tool: Keep pressing the BASE for 2s to shut the tool. And if there s no action in 60s, the tool will turn off automatically. Tips: A. The measured object must be a normative horniness surface and without barrier. B. To ensure exact measurement, the measured surface should be smooth, bigger area and of homogeneity. C. If the measured surface is too small, abnormity or the surface is soft, a board should be placed on the surface of measured object. D. The unit can t measure through the glass. E. When measuring, the tool should keep a distance away from the measured object at least 2 feet (50cm). F. To ensure exact measurement, the temperature of the tool should be same with the temperature of environment G.. If the tool has been off automatically or by hand, just restart the tool after 5s. Addition (W/O using M memory) Press READ key for measurement and the measured value is displayed on upper portion of the screen (note: when bidirectional measurement,the addition of left measurement result and right measurement result will display on the lower portion of the screen); Press +/= key to enter the addition mode, and the + icon will appear on upper portion of the screen. At the same time, the addition of primary data on lower portion and measurement result now is displayed on the lower side of the display. 4

Notes: 1. When enter + operation for the first time, the primary data will be seemed as 0 to do addition. 2. Pressing +/= key will be of no effect, when the tool with no any measurement (the data is 0.00m on the upper portion). 3. If the data is continuous dynamic measuring result, the last display data will enter into the + operation. Press READ key again for second time measurement, the measured value is displayed on the screen; Press +/= key again to display the new sum on the lower portion of the screen; Note: If continuously press the +/= key for 2 times, the addition operation will be canceled, all the anterior computation result will clear away. Repeat the steps:3~4 above can continue accumulation. Addition (using M memory) Press the M key to save the first measured result, and the M+ will appear on the right portion of the screen. Press the READ key for new measurement and display the result. Press the RM key to recall previous measurement for the addition (displayed on the bottom of the display), and at the same time, the M+ icon disappears and the stored memories will be automatically eliminated; 5

Press+/= key for accumulation, the result of memory data and measurement data will display on the lower portion of the screen. At the same time, + icon will display on the upper portion of the screen. Notes: 1. If continuously press the +/= key twice, the addition operation will be canceled, all the anterior computation result will clear away. 2.At this moment, if pressing M key again, the tool will memory the result on the bottom of the display. The tool will add with accumulation. Area Press MODE key to enter area mode, and the " "will appear on the display. The length character " " on the display will blink with the frequency of 2Hz showing the length measurement you will be firstly taking. Press READ key to take length measurement and display on the screen. (Step 1); The width character " " on the display will blink showing the next measurement to take. Press READ key to take width measurement and display on the screen (Step 2); 6

Then the area character" "on the display will blink, Pressing READ key to take the area result and display on the lower portion of the screen. At this moment, the " " icon won t blink again. (Step 3); Press the READ key again will toggle back and forth between the length and width, area measurement result and corresponding icon " " " " and" " will display and blink with the frequency of 2Hz on the screen, meanwhile the measurement won t work. Press MODE key again to clear the data on the portion of the screen, then can begin the new calculation of area. Addition of area under area mode: Press the M key to save the calculated area on the lower portion of the screen, at the same time, the M+ icon appears on the screen; Press MODE key again to begin the second time measurement and computation (follow step 1, 2 and 3 under the area section); After getting the desired area of the second time computation, press +/= to enter the addition mode. A + icon would appear on LCD. Note: If continuously press the +/= key for 2 times, the addition operation will be canceled and the icon +/= will disappear (Press+/= key shortly for one time will enter into addition, Press+/= key 7

shortly for two times will cancel the operation. Then press again will toggle back and forth between: add----cancel----add). Press RM key to recall the first calculated area and display on the lower portion of the screen for the addition. The M+ icon will disappear and the stored memory will be automatically cleared; Press +/= key again, the sum of both areas is shown on the lower portion of the screen; Repeat the steps above to keep adding the measured area. Repeat the steps:1~5 above can continue accumulation. Volume Press MODE key to enter volume mode, and the " "will appear on the display. The length character " " on the screen will blink with the frequency of 2Hz showing length measurement will be taking. Press READ key to take length measurement, the result will be displayed on the screen. (Step 1) The width character " " on the screen will blink showing the next measurement to take. Press READ key to take width measurement, the result will be displayed on the screen. (Step 2) 8

The height character H on the screen will blink showing the next measurement to take. Press READ key to take height measurement, the result will be displayed on the screen. (Step 3); The volume character " "on the display will blink, Pressing READ key to take the volume result and display on the lower portion of the screen. At this moment, the " "icon won t blink again. (Step 4); Press the READ key again will toggle back and forth between the length and width, height, volume measurement result and corresponding icon " " " " " " and " "will display and blink with the frequency of 2Hz on the screen, meanwhile the measurement won t work. Press MODE key to clear the data on the screen, and then can begin the new calculation of volume; Addition of volumes under volume mode: Press M key to save the calculated volume on the lower portion of the screen, and the M+ icon will appear on LCD; Press MODE key again to begin the second time measurement and computation (Follow step 1,2, 3 an 4 under the volume section). After getting the calculated volume of second time, press +/= key to enter the addition mode. A 9

+ icon would appear on LCD; Note: If continuously press the +/= key for 2 times, the addition operation will be canceled and the icon +/= will disappear (Press+/= key shortly for one time will enter into addition, Press+/= key shortly for two times will cancel the operation. Then press again will toggle back and forth between: add----cancel----add). Press RM key to recall the first calculated volume and display on the lower portion for the addition. The M+ icon will disappear and the stored memory will be automatically cleared; Press +/= key again, the sum of both volumes is shown on the lower portion of the screen; Repeat the steps:1~5 above can continue accumulation. Temperature display Press and hold MODE key for 2 seconds, the environment temperature will appear on the lower portion of screen (the unit is if the distance unit is M, while the unit is if the distance unit is ft/in), and press the READ key again to return the measuring state. OPERATION INSTRUCTION If restart the tool immediately after turnning off the tool ( the interval time is less than 5s ), may cause the following result: no reaction after pressing the key or disordered phenomena of the screen. Please take off the battery and put it for another time to come back to the original condition. Inaccurate measurement may result from the following: 10

When the battery runs out: at this time, the icon will continuously appear on LCD to remind you to replace the battery. When the measured distance is out of the specified range: the effective range is 2 ~53 (0.5~16m). When the calculated result is out of the specified range: at this time, an error message Err will be displayed on the lower line of the screen. When addition of different parameters (e.g. length plus area), the + will be ignored and the screen will keep the same read as the unit was operated before. When another ultrasonic source or high frequency noise is nearby: leave or shut down the noise resource when taking measurement. When barriers appear between the tool and the measured surface. When the measured surface is not smooth: the measured surface should be smooth, hard and of homogeneity. When the measuring environment is not good: the temperature and humidity will affect the accuracy of measurement, and take measurement under environment of no wind, and temperature of the unit should be same with temperature of the circumstance, especially for long distance measuring (between 40 to 53 / 12m to 16m), the relative humidity should be above 48%, and the size of measured surface should be at least 10ft. by 10ft./3m by 3m. When measuring, ultrasonic sensor aperture should straightly face to the measured surface. Cautions Handle with care and do not let the tool drop down. Do not disassemble the tool to avoid failure. Keep the tool dry and clean. Store the tool in a box when not in use. Avoid dust and water, which may stain the lens. Check battery regularly to avoid deterioration. Remove the battery when not in use for an extended period of time. 11

TECHNICAL SPECIFICATIONS Name Type Bidirectional ultrasonic distance measurement KC-200 Recommended use Indoor Range of Measurement for 0.5~16m effective single direction measurement Measurement for 1~32m bidirectional direction Distance of limit measurement 40m (under the standard test environment) Accuracy ±1%±1digit Basement select Left edge, midpoint, right edge Calculation range Length 9999 11 (9999.99m) Area 99999.9 sq ft (99999.9 m2 ) Volume 999999 cu ft (999999m 3 ) Resolution 0.01m Wavelength of laser 630~660nm Temperature range 0 to +40 Laser Class Class II Power supply One 9V battery Backlight automatic off The backlight will be automatically off if there s no action in 15 seconds.(press any key to start the backlight) Automatic off The tool will be automatically off if there s no action 60 seconds. Power supply One 9V battery Power consumption <80mA Operating temperature 0 to 40 Operating humidity 30%~70%RH Storage environment -20 ~+60, 85%(w/o battery) Size 180mm 82mm 49mm Weight About 190g (battery not included) WARRANTY The product is warranted to be free from defects in materials and workmanship for a period of one year from the date of purchase on the basis of providing relevant card. Notice: The warranty does not apply to the following conditions Disassembling the laser tool will void the warranty. Any damage resulting from, but not limited to wear, water, being dropped or repairs attempted by others. Tips:Most parts of the product could be recycled, please refer to your local regulations for disposing of them instead of throwing into the dustbin. 12