EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

Similar documents
EMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

EMC TEST REPORT for Repel-it. REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019

Test Report GUANGDONG EAST POWER CO., LTD

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

Test Report. Apricus Solar Co., Ltd. Multi-Function Differential Controller

Test Report GUANGDONG EAST POWER CO., LTD

PT. SARANA KARYA SOLUSINDO.

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

EMC TEST REPORT. For MICRO-STAR INT'L CO.,LTD. USB Card Reader

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

Shenzhen Huanxi Technology Co., Ltd. Smart Self-balancing Scooter

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

EMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U

EMC TEST REPORT. Report No.: CE10-LIE040101E

EMC VERIFICATION SUMMARY Report No.: SZHH

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

EMC TEST REPORT For MUST POWER LIMITED. Inverter. Model No.: PV18-5K MPK, PV18-5K PK, PV18-4K MPK, PV18-4K PK

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

EMC TEST REPORT For : SHENZHEN HITEVISION TECHNOLOGY CO., LTD. Interactive Whiteboard

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

ELECTRONICS TESTING CENTER(ETC), TAIWAN

Verification On Behalf of Shenzhen Leer Chuang Technology Co., Ltd.

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

1 SUMMARY OF STANDARDS AND RESULTS

EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

EMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S

APPLICATION FOR VERIFICATION On Behalf of Carewell Electric Technology (Zhongshan) Co., Ltd. REMOTE CONTROL Model No.: AC8 FCC ID: 2AAZPAC8

EMC TEST REPORT For. Global Tech China Limited. 120/200 Watt Mightylite. Model No.: Additional Model No: Please Refer To Page 57

TABLE OF CONTENTS. Report Reference No.: GST E Issued: Oct. 21, 2011 Revised: None. Page 2 of 46

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

EMC Test report for LED Panel Light Models , , , , ,

FCC TEST REPORT On Behalf of. Global Tech China Limited. Solar Light(Large)/28W,16W. Model No.: Additional Model No: Please Refer To Page 15

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

Dongguan Nore Testing Center Co., Ltd. Report No.: NTC F TABLE OF CONTENTS

King Pigeon Communication Co., Limited

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U

Test Report. Model No.: NF594XX-YYYY-ZZ(X,Y & Z: Stands for A-Z & 0-9 ) HBJC1XXF594-YYYY-ZZ (X,Y & Z: Stands for A-Z & 0-9 )

EMC COMPLIANCE TEST REPORT

TEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015.

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN

FCC CLASS B COMPLIANCE REPORT (DoC)

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

2620 Modular Measurement and Control System

TEST REPORT. Building 6,XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Trade Name : Activision. Model Number: / FCC ID: XLU

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of. Superior communications. Wireless charger. Model Number: Additional Model: 06122

APPLICATION FOR CERTIFICATION On Behalf of. Philips Consumer Electronics Company. Digital Audio Player

EMC TEST REPORT For Prokits Industries Co., Ltd.

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

APPLICATION FOR VERIFICATION On behalf of MATRIX LIGHTING LTD. LED spot light. Model No.: 50-45GUS 50-45EUS Serial No.: E /02 E /02

EMC TEST REPORT For Gztod. Co., Ltd. Smart USB Charger Model No.: YA50WS3-8U

FCC & RSS-216 (Class II Permissive Change) Wireless Power Transfer Report. for A Acer Incorporated

EMC TEST REPORT for SmartAV Ses Goruntu Sistemleri Tic. Ltd. Sti. Video Conferencing Camera. Model No.: UV510A-S20-ST

No. 620 HuaYuan Commercial Center, No. 347 XiXiang Road,XiXiang Town, Bao An District, ShenZhen City Tel : Fax:

EMC TEST REPORT For LOKOLED LED Downlight Model No.: LL-17-45W-Floodlight-R-VL, LL-06-45W-18K/M

TEST REPORT... 1 CONTENT...

FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of SUNVALLEYTEK INTERNATIONAL, INC. VAVA Docking Station. Model Number: VA-DK001

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

EMC test report AU01+E04

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

Page: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK

CE/EMC TEST REPORT. For. Noron Ltd.

EMC TEST REPORT. For Shenzhen Scotle Technology Ltd CNC ROUTER. Model No.: HY-3040, HY-6040, HY-TB5, CNC 3040, CNC 6040, CNC 6090, CNC 1040, CNC 1325

CENTRE OF TESTING SERVICE INTERNATIONAL

Transcription:

EMC TEST REPORT For Company Limited Liability «Faraday Electronics» Switching Mode Power Adaptor Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) Prepared For : Company Limited Liability «Faraday Electronics» : Flat 37, House 4, UL Kirovogradskaya, Kiev, Ukraine Tel: +38-67-238-39-44 Prepared By : Shenzhen PTSI Testing Co., Ltd. : 7/F, Baoyuan Building, Baoyuan Road, Xixiang, Baoan, Shenzhen, Guangdong, China Tel : +86-755-27820019 Fax: +86-755-27215519 Report Number : PSZ1204026E Date of Test : April 05, 2012 to April 11, 2012 Date of Report : April 12, 2012

TABLE OF CONTENT 1. GENERAL INFORMATION... 4 1.1 DESCRIPTION OF DEVICE (EUT)... 4 1.2 DESCRIPTION OF TEST FACILITY... 4 1.3 MEASUREMENT UNCERTAINTY... 4 2. MEASURING DEVICE AND TEST EQUIPMENT... 5 2.1 FOR POWER LINE CONDUCTED EMISSION... 5 2.2 FOR DISTURBANCE POWER TEST... 5 2.3 FOR HARMONIC CURRENT / FLICKER MEASUREMENT... 5 2.4 FOR ELECTROSTATIC DISCHARGE IMMUNITY TEST... 5 2.5 FOR ELECTRICAL FAST TRANSIENT /BURST IMMUNITY TEST... 5 3. POWER LINE CONDUCTED EMISSION MEASUREMENT... 6 3.1 BLOCK DIAGRAM OF TEST SETUP... 6 3.2 MEASURING STANDARD... 6 3.3. LIMITS... 6 3.4 EUT CONFIGURATION ON MEASUREMENT... 6 3.5 OPERATING CONDITION OF EUT... 7 3.6 TEST PROCEDURE... 7 3.7 MEASURING RESULTS... 7 4. DISTURBANCE POWER TEST... 8 4.1 BLOCK DIAGRAM OF TEST SETUP... 8 4.2 TEST STANDARD... 8 4.3 DISTURBANCE POWER LIMIT... 8 4.4 EUT CONFIGURATION ON TEST... 8 4.5 OPERATING CONDITION OF EUT... 8 4.6 TEST PROCEDURE... 8 4.7 DISTURBANCE POWER TEST RESULTS... 9 5. HARMONIC CURRENT EMISSION MEASUREMENT... 10 5.1 BLOCK DIAGRAM OF TEST SETUP... 10 5.2 MEASURING STANDARD... 10 5.3. OPERATION CONDITION OF EUT... 10 5.4 MEASURING RESULTS... 10 6. VOLTAGE FLUCTUATION AND FLICKER MEASUREMENT... 11 6.1 BLOCK DIAGRAM OF TEST SETUP... 11 6.2 MEASURING STANDARD... 11 6.3 OPERATION CONDITION OF EUT... 11 6.4 MEASURING RESULTS... 11 7. ELECTROSTATIC DISCHARGE IMMUNITY TEST... 13 7.1 BLOCK DIAGRAM OF TEST SETUP... 13 7.2 TEST STANDARD... 13 7.3 SEVERITY LEVELS AND PERFORMANCE CRITERION... 13 7.4 EUT CONFIGURATION... 13 7.5 OPERATING CONDITION OF EUT... 14 Page 1 of 29

7.6 TEST PROCEDURE... 14 7.7 TEST RESULTS... 14 8. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST... 16 8.1 BLOCK DIAGRAM OF TEST SETUP... 16 8.2 TEST STANDARD... 16 8.3 SEVERITY LEVELS AND PERFORMANCE CRITERION... 17 8.4 EUT CONFIGURATION... 17 8.5 OPERATING CONDITION OF EUT... 17 8.6 TEST PROCEDURE... 17 8.7 TEST RESULT... 18 APPENDIX I (2 pages) APPENDIX II (2 pages) APPENDIX III (Photos of the EUT) (3 pages) Page 2 of 29

1. GENERAL INFORMATION 1.1 Description of Device (EUT) EUT Model Number Trade Mark Power Supply : Switching Mode Power Adaptor : 19W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) [18V, 1.0A for model 19W/14.4V/EU(18V/1.0A); 12V, 1.5A for model 19W/14.4V/EU(12V/1.5A). The two models are identical, only except the output rating. Model 19W/14.4V/EU (12V/ 1.5A) has larger output current, selected as the representative model.] : FARADAY ELECTRONICS : 230V~, 50Hz Applicant : Company Limited Liability «Faraday Electronics» Address : Flat 37, House 4, UL Kirovogradskaya, Kiev, Ukraine Manufacturer : Faraday Electronics (Hong Kong) Co., Ltd. Address : #A1102, Tian He Lian Meng Building, Xin Sha Road, Sha Jing Town, Bao'an District, Shenzhen, China Date of receiver : April 05, 2012 Date of Test : April 05, 2012 to April 11, 2012 1.2 Description of Test Facility Site Description EMC Lab. : Accredited by TUV Rheinland Shenzhen 2011.09.16 The certificate is valid until 2013.09.16 The Laboratory has been assessed according to the requirements ISO/IEC 17025: 2005 Name of Firm Site Location Accredited by FCC, July 20, 2010 The Certificate Number is 600491. Accredited by Industry Canada, March 05, 2010 The Certificate Registration Number is 9079A-1. : Shenzhen PTSI Testing Co., Ltd. : 7/F, Baoyuan Building, Baoyuan Road, Xixiang, Baoan, Shenzhen, Guangdong, China 1.3 Measurement Uncertainty Radiation Emission Uncertainty : Ur = 3.3 Conduction Emission Uncertainty : Uc = 2.8 Power clamp Emission Uncertainty : Uc = 2.6 Page 4 of 29

2. MEASURING DEVICE AND TEST EQUIPMENT 2.1 For Power Line Conducted Emission Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Test Receiver Rohde & Schwarz ESCS30 828985/018 May 29, 2011 1 Year 2. L.I.S.N Rohde & Schwarz ESH2-Z5 834549/005 May 29, 2011 1 Year 3. Pulse Limiter Rohde & Schwarz ESH3-Z2 100006 May 29, 2011 1 Year 4. 50ΩCoaxial Switch Anritsu MP59B M20531 May 29, 2011 1 Year 2.2 For Disturbance Power Test Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Test Receiver Rohde & Schwarz ESCS30 100137 May 29, 2010 1 Year 2. Power Clamp Rohde & Schwarz MDS21 100220 May 29, 2010 1 Year 3. 50ΩCoaxial Switch Anritsu MP59B 610017558 9 2.3 For Harmonic Current / Flicker Measurement May 29, 2010 1 Year Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Power Frequency Test System HAEFELY PHF555 080419-03 May 29, 2010 1 Year 2. PC N/A P2L97 N/A May 29, 2010 N/A 2.4 For Electrostatic Discharge Immunity Test Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. ESD Tester Schaffner NSG432 1285 May 29, 2010 1 Year 2.5 For Electrical Fast Transient /Burst Immunity Test Item Equipment Manufacturer Model No. Serial No. Last Cal. Cal. Interval 1. Burst Tester HAEFELY PEFT401 080981-16 May 29, 2010 1Year 0 2. Coupling Clamp HAEFELY IP-4A 147147 May 29, 2010 1Year Page 5 of 29

3. POWER LINE CONDUCTED EMISSION MEASUREMENT 3.1 Block Diagram of Test Setup 3.1.1 Block diagram of connection between the EUT and simulators AC Mains EUT Load 3.1.2 Block diagram of test setup (EUT: Switching Mode Power Adaptor) Test Receiver AC Mains L.I.S.N EUT Load 3.2 Measuring Standard 3.3. Limits (EUT: Switching Mode Power Adaptor) EN55013: 2001 +A1: 2003+A2: 2006 Power Line Conducted Emission Limits (Class B) Frequency Limit (dbμv) (MHz) Quasi-peak Level Average Level 0.15 ~ 0.50 66.0 ~ 56.0 * 56.0 ~ 46.0 * 0.50 ~ 5.00 56.0 46.0 5.00 ~ 30.00 60.0 50.0 NOTE1-The lower limit shall apply at the transition frequencies. NOTE2-The limit decreases linearly with the logarithm of the frequency in the range 0.15MHz to 0.50MHz. 3.4 EUT Configuration on Measurement The following equipments are installed on Conducted Emission Measurement to see EN 55022 and EN55013 requirements and operating in a manner which tends to maximize its emission characteristics in normal application. EUT Model No. Manufacturer : Switching Mode Power Adaptor : 19W/14.4V/EU(12V/1.5A) : Faraday Electronics (Hong Kong) Co., Ltd. Page 6 of 29

3.5 Operating Condition of EUT 3.5.1 Setup the EUT as shown on Section 3.1. 3.5.2 Turn on the power of all equipments. 3.5.3 Let the EUT work in measuring mode (Full Load) and measure it. 3.6 Test Procedure The EUT is put on the plane 0.8m high above the ground by insulating support and connected to the AC mains through Line Impedance Stability Network (L.I.S.N). This provided 50-ohm coupling impedance for the tested equipments. Both sides of AC line are investigated to find out the maximum conducted emission according to the EN55013 regulations during conducted emission measurement. The bandwidth of the field strength meter (R&S Test Receiver ESCS30) is set at 9KHz in 150KHz~30MHz and 200Hz in 9KHz~150KHz. The frequency range from 150kHz to 30MHz is investigated. All the scanning waveform is put in Appendix I. 3.7 Measuring Results PASS. Please reference to the following page. Page 7 of 29

4. DISTURBANCE POWER TEST 4.1 Block Diagram of Test Setup 4.2 Test Standard AC Mains EUT Load (EUT: Switching Mode Power Adaptor) EN55013: 2001 +A1: 2003+A2: 2006 4.3 Disturbance Power Limit All emanations from devices or system including any network of conductors and apparatus connected thereto, shall not exceed the level of field strengths specified below: Frequency Interference Power Limits db(pw) MHz Quasi-peak Value Average Value 30 ~ 300 45 Increasing Linearly with Frequency to 55 (Q.P.) 35 Increasing Linearly with Frequency to 45 (A.V.) 4.4 EUT Configuration on Test The EN55013 regulations test method must be used to find the maximum emission during radiated emission test. The configuration of EUT is the same as used in conducted emission test. 4.5 Operating Condition of EUT 4.5.1 Turn on the power. 4.5.2 Let the EUT work in test mode (Full Load)and measure it. 4.6 Test Procedure The EUT is placed on the ground and away from other metallic surface at least 0.8m. It is connected to the power mains through an extension cord of 6m min. The absorber clamp clamps the cord and moves from the far end to the EUT to measure the disturbing energy emitted from the cord. The bandwidth of the test receiver(r&s ESCS30) is set at 120kHz. All the test results are listed in Section 4.7. The scanning waveforms are attached in Appendix II. Page 8 of 29

4.7 Disturbance Power Test Results PASS. The frequency spectrum from 30 MHz to 300 MHz is investigated. Page 9 of 29

5. HARMONIC CURRENT EMISSION MEASUREMENT 5.1 Block Diagram of Test Setup AC Mains Power frequency test system EUT Load PC 5.2 Measuring Standard EN 61000-3-2: 2006 POWER<75W 5.3. Operation Condition of EUT (EUT: Switching Mode Power Adaptor) Same as Section 3.4, except the test setup replaced as Section 6.1. 5.4 Measuring Results PASS. Because power of EUT is less than 75W, according to standard EN61000-3-2, Harmonics Current is not required. Page 10 of 29

6. VOLTAGE FLUCTUATION AND FLICKER MEASUREMENT 6.1 Block Diagram of Test Setup AC Mains Power frequency test system EUT Load PC (EUT: Switching Mode Power Adaptor) 6.2 Measuring Standard EN 61000-3-3: 2008 6.3 Operation Condition of EUT Same as Section 3.4, except the test setup replaced as Section 7.1. 6.4 Measuring Results PASS. Please refer to the following pages. Page 11 of 29

---------------------------------------------------------------------- EN 61000-3-3 TEST REPORT 2012/04/08 15:44 ---------------------------------------------------------------------- Unit: Switching Mode Power Adaptor M/N: 19W/14.4V/EU (12V/1.5A) Serial No.: Remarks: Operator: Op Cond: Full Load Manuf: Faraday Electronics (Hong Kong) Co., Ltd. Alan He ===================================================================== TEST SETUP ---------- Test Freq.: 50.00 Hz. Test Voltage: 230.0 vac Waveform : SINE Test Time: 10.0 min. Tshort: 10.0 min. Prog. Zo Enabled: YES Prog. Zo: 0.000 Voltage Change less than once per Hour: NO Impedance selected: IEC-725 STD. REF. Synthetic R+L Enabled: Resistance: 0.380 Ohms NO Inductance: 460.000 uh Result: TEST DATA --------- PASS EUT Data Limit Result Test Enabled Pst max 0.006 1.00 PASS true Plt max 0.006 0.65 PASS true dc % 0.00 3.00 PASS true dmax % 0.00 4.00 PASS true d(t) sec. 0.00 0.50 PASS true Power Source Data Source Pst max 0.022 0.400 PASS true % THD 0.03 3.00 PASS true PAGE 1 END OF REPORT Page 12 of 29

7. ELECTROSTATIC DISCHARGE IMMUNITY TEST 7.1 Block Diagram of Test Setup 7.1.1 Block diagram of connection between the EUT and simulators AC Mains EUT Load (EUT: Switching Mode Power Adaptor) 7.1.2 Block diagram of ESD test setup 7.2 Test Standard (EUT: Switching Mode Power Adaptor) EN55020: 2007 (EN61000-4-2: 2001 Severity Level: 3 / Air Discharge: ±8KV Level: 2 / Contact Discharge: ±4KV) 7.3 Severity Levels and Performance Criterion 7.3.1 Severity level Level Test Voltage Test Voltage Contact Discharge (KV) Air Discharge (KV) 1. ±2 ±2 2. ±4 ±4 3. ±6 ±8 4. ±8 ±15 X Special Special 7.3.2 Performance Criterion: B 7.4 EUT Configuration Page 13 of 29

The configuration of EUT is listed in Section 3.4. 7.5 Operating Condition of EUT The same as conducted emission measurement, which is listed in Section 3.4, except the test set up is replaced by Section 8.1. 7.6 Test Procedure 7.6.1 Air Discharge: This test is done on a non-conductive surface. The round discharge tip of the discharge electrode shall be approached as fast as possible to touch the EUT. After each discharge, the discharge electrode shall be removed from the EUT. The generator is then re-triggered for a new single discharge and repeated 10 times for each pre-selected test point. This procedure shall be repeated until all the air discharge completed. 7.6.2 Contact Discharge: All the procedure shall be same as Section 7.6.1. Except that the tip of the discharge electrode shall touch the EUT before the discharge switch is operated. 7.6.3 Indirect discharge for horizontal coupling plane: At least 10 single discharges (in the most sensitive polarity) shall be applied at the front edge of each HCP opposite the center point of each unit (if applicable) of the EUT and 0.1m from the front of the EUT. The long axis of the discharge electrode shall be in the plane of the HCP and perpendicular to its front edge during the discharge. 7.6.4 Indirect discharge for vertical coupling plane: At least 10 single discharges (in the most sensitive polarity) shall be applied to the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, is placed parallel to, and positioned at a distance of 0.1m from the EUT. Discharges shall be applied to the coupling plane, with this plane in sufficient different positions that the four faces of the EUT are completely illuminated. 7.7 Test Results PASS. Please refer to the following pages Page 14 of 29

Electrostatic Discharge Test Results Shenzhen PTSI Testing Co., Ltd. Applicant : Company Limited Liability «Faraday Electronics» Test Date : April 09, 2012 EUT : Switching Mode Power Adaptor Temperature : 22 M/N : 19W/14.4V/EU(12V/1.5A) Humidity : 50% Power Supply : AC 230V 50Hz Test Engineer : Jees Test Mode : Full Load Criterion : B Air Discharge: ±2, 4, 6, 8KV Contact Discharge: ±2, 4KV # For each point positive 10 times and negative 10 times Location Kind A-Air Discharge C-Contact Discharge Result Slot of the EUT 16 points A PASS HCP C PASS VCP of Front C PASS VCP of Rear C PASS VCP of Left C PASS VCP of Right C PASS Remark : Test Equipment : ESD Tester (Schaffner, NSG432) Discharge should be considered on Contact and Air and Horizontal Coupling Plane (HCP) and Vertical Coupling Plane (VCP). Page 15 of 29

8. ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST 8.1 Block Diagram of Test Setup 8.1.1 Block Diagram of the EUT AC Mains EUT Load 8.1.2 EFT Test Setup (EUT: Switching Mode Power Adaptor) AC Mains EUT 0.1m 0.5m EFT/B Tester AC Mains 0.8m 0.8m 8.2 Test Standard (EUT: Switching Mode Power Adaptor) EN55020: 2007 (EN61000-4-4: 2004, Severity Level, Level 2: 1KV) Page 16 of 29

8.3 Severity Levels and Performance Criterion 8.3.1 Severity level Open circuit output test voltage and repetition rate of the impulses On power port, PE On I/O (Input/Output) Signal data and control ports Level Voltage peak KV Repetition rate KHz Voltage peak KV Repetition rate KHz 1. 0.5 KV 5 or 100 0.25 KV 5 or 100 2. 1 KV 5 or 100 0.5 KV 5 or 100 3. 2 KV 5 or 100 1 KV 5 or 100 4. 4 KV 5 or 100 2 KV 5 or 100 X Special Special Special Special NOTE 1 Use of 5 KHz repetition rates is traditional; however, 100 KHz is closer to reality. Product committees should determine which frequencies are relevant for specific products or product types. NOTE 2 With some products, there may be no clear distinction, between power ports and I/O ports, in which case it is up to product committees to make this determination for test purposes. X is an open level. The level has to be specified in the dedicated equipment specification. 8.3.2 Performance Criterion: B 8.4 EUT Configuration The configuration of EUT is listed in Section 3.4 8.5 Operating Condition of EUT 8.5.1 Setup the EUT as shown in Section 8.1. 8.5.2 Turn on the power of all equipments. 8.5.3 Let the EUT work in test mode (Full Load) and measure it. 8.6 Test Procedure The EUT is put on the table, which is 0.8 meter high above the ground. This reference ground plane shall project beyond the EUT by at least 0.1m on all sides and the minimum distance between EUT and all other conductive structure, except the ground plane beneath the EUT, shall be more than 0.5m. 8.6.1 For input and output AC power ports: The EUT is connected to the power mains by using a coupling device, which couples the EFT interference signal to AC power lines. Both polarities of the test voltage should be applied during compliance test and the duration of the test is 2 mins. 8.6.2 For signal lines and control lines ports: No I/O ports. It s unnecessary to test. 8.6.3 For DC output line ports: It s unnecessary to test. Page 17 of 29

8.7 Test Result PASS. Please refer to the following page. Page 18 of 29

Standard : Electrical Fast Transient/Burst Test Results Shenzhen PTSI Testing Co., Ltd. IEC 61000-4-4 EN 61000-4-4 Result : PASS / FAIL Applicant : Company Limited Liability «Faraday Electronics» EUT : Switching Mode Power Adaptor M/N : 19W/14.4V/EU(12V/1.5A) Input Voltage: AC 230V 50Hz Criterion : B Ambient Condition : 20 50% RH Operation Mode : Full Load Line : AC Mains Line : Signal I/O Cable Coupling : Direct Coupling : Capacitive Test Time : 120s Line Test Voltage Result (+) Result (-) L 1KV PASS PASS N 1KV PASS PASS PE L N 1KV PASS PASS L PE N PE L N PE Signal Line DC Line Note: Test Equipment Burst Tester Model : UCS500M6B Page 19 of 29

APPENDIX I Page 20 of 29

Page 21 of 29

Page 22 of 29

APPENDIX II Page 23 of 29

Page 24 of 29

Page 25 of 29

APPENDIX III (Photos of EUT) Page 26 of 29

Fig. 1 Top View Fig. 2 Bottom View Page 27 of 29

Fig.3 Internal View Fig.4 PCB Components Side View Page 28 of 29

Fig. 5 PCB Trace Side View Page 29 of 29