Evaluation and Limitations of Corona Discharge Measurements An Application Point of View

Similar documents
TD-100. HAEFELY HIPOTRONICS Technical Document

TD-106. HAEFELY HIPOTRONICS Technical Document. Partial Discharge Pulse Shape Analysis to Discriminate Near and Far End Failures for Cable Location

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

Modular Partial Discharge (PD) & Radio Interference Voltage (RIV) Detector

KIT 4.0 HIGH VOLTAGE CONSTRUCTION KIT. reliable. precision. HIGH V O L T A G E T E S T S OLUTION S

TRAINING OVERVIEW EDUCATION IS POWER. HIGH V O L T A G E T E S T S OLUTION S. reliable. precision.

700 Series AC Dielectric Test Sets

ALLOWABLE LIMITS TO SHORT TIME VOLTAGE DROPS IN HV WITHSTAND TESTS

EFFECT OF INTEGRATION ERROR ON PARTIAL DISCHARGE MEASUREMENTS ON CAST RESIN TRANSFORMERS. C. Ceretta, R. Gobbo, G. Pesavento

Mitigating Murphy s Law While Test. Frédéric Dollinger

CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN

CHAPTER 2. v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES

INVESTIGATION ON THE TECHNOLOGIES FOR DEFECT LOCALIZATION AND CHARACTERIZATION ON MEDIUM VOLTAGE UNDERGROUND LINES

TMS 580. Transformer Loss Measuring System FEATURES BENEFITS APPLICATIONS

Partial Discharge Patterns in High Voltage Insulation

International Journal of Advance Engineering and Research Development. Comparison of Partial Discharge Detection Techniques of Transformer

Automatic Transformer Winding Analyser

Extended analysis versus frequency of partial discharges phenomena, in support of quality assessment of insulating systems

Prepared by Mick Maytum

TTR2796. Fully Automated Three Phase 250V Transformer Turns Ratio Meter FEATURES AND BENEFITS APPLICATIONS

Coherence and time-frequency analysis of impulse voltage and current measurements

Partial Discharge Classification Using Acoustic Signals and Artificial Neural Networks

CABLE FAULT LOCATING APPLICATION GUIDE. HIGH V O L T A G E T E S T S OLUTION S. reliable. precision.

1409. Comparison study between acoustic and optical sensors for acoustic wave

MAHALAKSHMI ENGINEERING COLLEGE

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

Suppression of Pulse Interference in Partial Discharge Measurement Based on Phase Correlation and Waveform Characteristics

Signal Detection with EM1 Receivers

Parameter Optimization for Rise Time of Sub nanosecond Pulser Based on Avalanche Transistors

Partial discharge diagnostics on very long and branched cable circuits

UHF PD-DIAGNOSIS AT HIGH VOLTAGE CABLE TERMINATIONS INTERNATIONAL CASE STUDIES

Basics of Partial Discharge. Prepared for 2015 Phenix RSM Meeting January 2015

Analysis of Propagation Paths of Partial Discharge Acoustic Emission Signals

Immunity Testing for the CE Mark

Fully automated three phase 250V Transformer Turns Ratio Meter

SHF Communication Technologies AG. Wilhelm-von-Siemens-Str. 23D Berlin Germany. Phone Fax

HiAS TM 744 HIGHEST RESOLUTION IMPULSE ANALYZING SYSTEM

PULSE-SEQUENCE ANALYSIS OF PARTIAL DISCHARGES IN POWER TRANSFORMERS

EWGAE 2010 Vienna, 8th to 10th September

SPM Series Quick Start Experiment Guide Rev.1.0, May 2011

Visualization of the Ionization Phenomenon in Porous Materials under Lightning Impulse

Frequency Spectrum Analysis of Electromagnetic Waves Radiated by

SG A. Impulse Voltage Test System, kv / kj APPLICATION

PULSED BREAKDOWN CHARACTERISTICS OF HELIUM IN PARTIAL VACUUM IN KHZ RANGE

Comparison of measurement methods for partial discharge measurement in power cables

Keysight Technologies Pulsed Antenna Measurements Using PNA Network Analyzers

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic inspection Evaluating electronic characteristics of ultrasonic test instruments

Corona Current-Voltage Characteristics in Wire-Duct Electrostatic Precipitators Theory versus Experiment

Practical aspects of PD localization for long length Power Cables

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

IN HOUSE CALIBRATION OF PD DETECTOR SYSTEM FOR FIELD TEST RESULT RELIABILITY

Improving CDM Measurements With Frequency Domain Specifications

Measurement Of Partial Discharge (PD) In High Voltage Power Equipment

Reprint E Two Years of Experience with a Mobile Resonant Test System for Testing of Installed Medium- and High Voltage Power Cables

MIDAS 2881 / 2881G. Mobile Insulation Diagnosis & Analysing System

PD Solutions. On-Line PD Measurement Devices

Software System for Finding the Incipient Faults in Power Transformers

NEW MV CABLE ACCESSORY WITH EMBEDDED SENSOR TO CHECK PARTIAL DISCHARGE ACTIVITY

Investigation of PD Detection on XLPE Cables

ELECTROMAGNETIC EMISSIONS OF AC HIGH-VOLTAGE CORONA

GIS Disconnector Switching Operation VFTO Study

Amptek Inc. Page 1 of 7

Chapter 5. Signal Analysis. 5.1 Denoising fiber optic sensor signal

Partial Discharge Signal Detection by Piezoelectric Ceramic Sensor and The Signal Processing

New Features of IEEE Std Digitizing Waveform Recorders

FAULT IDENTIFICATION IN TRANSFORMER WINDING

Wavelet Analysis for Negative Return Stroke and Narrow Bipolar Pulses

IEEE (2016) (2016). IEEE.,

AC BARRIER PIN-PLANE CORONA: SIMILARITIES AND DISTINCTIONS TO DC POSITIVE AND NEGATIVE CORONAS AND DIELECTRIC BARRIER DISCHARGE

Test Specification for Type Approval

Multi-Resolution Wavelet Analysis for Chopped Impulse Voltage Measurements

CHAPTER 3 ACOUSTIC EMISSION TECHNIQUE FOR DETECTION AND LOCATION OF PD

THE POWER OF LIFE. WinTech Partial Discharge based Predictive Intelligence of insulation system to eliminate power failure risk.

HVDC Transmission. Michael Muhr. Institute of High Voltage Engineering and System Performance Graz University of Technology Austria P A S S I O N

Evaluation of Partial Discharge in Power Transformers by Acoustic Emission Method and Propagation Modeling of Acoustic Signal

EMC standards. Presented by: Karim Loukil & Kaïs Siala

Correlation Considerations: Real HBM to TLP and HBM Testers

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

2620 Modular Measurement and Control System

PIEZOELECTRIC TRANSFORMER FOR INTEGRATED MOSFET AND IGBT GATE DRIVER

Corona noise on the 400 kv overhead power line - measurements and computer modeling

Aspects of PD interpretation in HV power cables. by Edward Gulski, Piotr Cichecki, Rogier Jongen

Software for Partial Discharge and Localization

A Novel Measurement System for the Common-Mode- and Differential-Mode-Conducted Electromagnetic Interference

Power Engineering II. High Voltage Testing

Making sense of electrical signals

A TECHNICAL REVIEW ON CAPACITOR BANK SWITCHING WITH VACUUM CIRCUIT BREAKERS

ANALYSIS OF ELECTRON CURRENT INSTABILITY IN E-BEAM WRITER. Jan BOK, Miroslav HORÁČEK, Stanislav KRÁL, Vladimír KOLAŘÍK, František MATĚJKA

Transmission Line Pulse Testing and Analysis of Its Influencing Factors

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

A SIMPLE METHOD TO COMPARE THE SENSITIVITY OF DIFFERENT AE SENSORS FOR TANK FLOOR TESTING

A New Method of Emission Measurement

MEASUREMENT OF THE INTERNAL INDUCTANCE OF IMPULSE VOLTAGE GENERATORS AND THE LIMITS OF LI FRONT TIMES

INTRODUCTION TO CONDUCTED EMISSION

Effect of Aging on Power Integrity of Digital Integrated Circuits

Definitions. Spectrum Analyzer

PARTIAL DISCHARGE DETECTION AND LOCATION IN TRANSFORMERS BY PERFORMING PARTIAL DISCHARGE TESTS IN OIL USING UHF SENSORS

-149- MICROSECOND-SCALE ELECTRIC FIELD PULSES IN CLOUD LIGHTNING FLASHES

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

The Causes and Impact of EMI in Power Systems; Part 1. Chris Swartz

Transcription:

Evaluation and Limitations of Corona Discharge Measurements An Application Point of View P. Mraz, P. Treyer, U. Hammer Haefely Hipotronics, Tettex Instruments Division

2016 International Conference on Condition Monitoring and Diagnosis Xi an China Evaluation and Limitations of Corona Discharge Measurements An Application Point of View P. Mraz *, P. Treyer, U. Hammer Haefely Hipotronics Basel, Switzerland mraz.petr@haefely.com Abstract The phenomenon of corona discharge has been extensively discussed in numerous publications. However, those studies mostly focused on physical and chemical processes or the comparison of the corona effect for different isolation materials such as air, oil, etc. In this paper the effect of corona partial discharges is investigated from an application point of view. Corona characteristics and discharge patterns are explained and discussed starting from an initial phase which is dominated by Trichel pulses up to the onset of breakdown (pre-breakdown streamers). The limitations of electrical partial discharge measurements for the evaluation of corona discharges are examined. Keywords partial discharge; corona; Trichel pulses; pulsefree zone; corona discharge fingerprints I. INTRODUCTION Partial Discharge (PD) measurement is an important part of modern and progressive diagnostic methods in high-voltage (HV) testing. The topic of PD measurement and evaluation has been investigated in numerous publications but only few have focused on an application point of view to particular PD effects. This paper deals with corona discharge which belongs to the group of external PD discharges. Special emphasis is placed on the evaluation of the voltage dependence of corona discharges. It is shown that, depending on the applied voltage, the cluster characteristics of corona discharges can be divided into four distinct development stages. A total of eight characteristic cluster patterns are identified depending on the location of the corona source (HV or Earth), the position of the measuring impedance and the development stage of the corona process. Based on the polarity of the corona discharge pulses and the cluster position the corona source can be clearly localized. As described in this paper, proper selection of the test setup and proper tuning of the partial discharge detector characteristics is essential to successfully interpret corona discharge patterns. The occurrence of a pulse-free zone in the corona cluster is experimentally verified and discussed. This particular effect can be observed during Phase III of the corona discharge formation process and is characterized by the absence of partial discharge pulses in the center of the corona cluster. This phenomenon is caused by the bandwidth limitations according to IEC 60270 [1] and comparatively high pulse repetition rates observed for corona discharges. In this paper the well-known observation of a pulse-free zone (i.e. a drop in PD magnitude) for corona discharge pulses is thoroughly analyzed and verified by practical measurements. II. CHARACTERISTICS OF CORONA FORMATION A basic needle-plane test arrangement has been chosen for all measurements. Corona discharge has been simulated with a brass needle tip (Æ 24!m before electrical stress), a circular lower brass electrode (Æ 75 mm) and a gap distance of 10 mm. A. Phase I If high-voltage is applied to the needle, discharge pulses can be observed in the negative half of the AC sine wave (Fig. 1a). These so-called Trichel pulses [2, 3] have relatively small amplitude (depending on the tip shape), high repetition rate and remain stable over time. Trichel pulses are caused by a fast transfer of electrons from the high-voltage electrode (needle) to the ground electrode (plane). The emission of the electrons leads to slow positive ions being generated. A space charge region is developed around the tip which inhibits further electron movement after a certain time. Only when the ions are moved away subsequent pulses can be initiated. B. Phase II As shown in Fig. 1b an increase of the test voltage causes the Trichel pulses to spread over a wider area of the AC phase. The number of electrons travelling between the electrodes is raised (avalanching) and a higher PD repetition rate is observed. C. Phase III Further increase of the test voltage results in the emergence of a pulse-free zone in the PD pattern. This special zone is located in the center of the Trichel pulse cluster (Fig. 1c). Common partial discharge detectors in compliance with IEC 60270 fail to correctly display PD pulses in this particular area. In fact, the repetition rate of pulses in this area is so high, that common PD analyzers are not able to recognize these pulse trains, the reason for this effect being the limited bandwidth settings according to [1], as explained in section V. D. Phase IV If the test voltage is further increased (close to the breakdown voltage of the test arrangement) high energy pulses occur in the positive half of the AC sine wave (Fig. 1d). These pre-breakdown or onset streamers exhibit high charge (i.e. energy) levels (significantly higher than Trichel pulses) and a tendency towards instability. The pulses are located in the positive half of the AC sine wave (needle) since this emerging conductive channel consists of positive streamers. Due to their high instability these streamer discharges can easily induce a 978-1-5090-3397-3/16/$31.00 2016 IEEE 273

voltage breakdown during phase IV. In that case onset streamers can be observed in both polarities of the test voltage. Phase IV is characterized by an audible (acoustic) effect. a) b) c) d) Fig. 1: Corona development phases in the pulse (-q) diagram: a) Phase I, b) Phase II, c) Phase III, d) Phase IV. The charge-voltage dependency is distinctive for each type of PD failure. Fig. 2 shows the typical characteristics of corona discharges. For lower voltages (phase I III) a quasi-constant charge level is observed. Therefore, this particular behavior was used like a high-voltage PD calibrator in the past [4]. It should be noted, that the measured charge level is dependent on the tip radius and the described effect is valid only in a certain range of the test voltage. If the voltage is further increased, the stability of the charge value is reduced (see higher dispersion values for elevated voltages in Fig. 2). Pulse polarity recognition is influenced by the aspects mentioned above together with the respective pulse recognition technique implemented inside the PD instrument. One of the main parameters for pulse recognition is the so-called dead time parameter used in common PD instruments. Some PD detectors use a fixed dead time value which can be adjusted if needed. Another approach is to calculate the dead time value based on PD instrument settings without access for the user to tune the value. Several PD detectors allow prolonging of the dead time value. A constant value for the dead time parameter can lead to ambiguous recognition of the pulse polarity as shown in Fig. 3a. Pulse shape and duration can differ during normal PD testing depending on the voltage level which affects the character of the PD behavior or which can trigger an additional PD failure source with different pulse characteristics. Dead time is only one part of the pulse recognition algorithm and in particular cases usage of a fixed dead time parameter can lead to wrong polarity recognition. This is irrespective of the PD failure type and occurs for all type of PD, independent of the repetition rate. For correct polarity detection separate signal processing is required for PD detection and PD level measurement. Successful pulse detection requires the full PD detector bandwidth in addition to a dedicated pulse recognition algorithm as implemented e.g. in the DDX 9121b PD measuring instrument [6]. a) b) Phase IV Fig. 3: Pulse polarity: a) ambiguous recognition due to fixed dead time, b) distinct recognition without ambiguity. Fig. 2: Charge-voltage dependence of corona discharge III. Phases I, II, III PD PULSE POLARITY RECOGNITION Correct pulse polarity recognition is of major concern for PD measurement and evaluation especially in case of corona discharges. The source of corona discharges can be determined by virtue of the PD cluster position with respect to AC phase, cluster type as well as the pulse polarity. The shape of the measured PD pulse is mainly determined by the following aspects [5]: PD failure type Impedance characteristics of the test object PD travelling path PD measurement system available bandwidth As previously discussed correct pulse recognition is essential to determine the origin of PD failures under AC stress. Correct pulse recognition becomes even more critical under DC stress since the number of PD pulses is one of the acceptance criteria for HVDC equipment. Using a fixed dead time parameter can cause tremendous measurement errors and acceptance problems for the device under test (DUT). For example, if the dead time parameter is selected too short oscillations caused by the PD filter settings will be recognized as additional PD events, hence the number of PD pulses is over-estimated. On the other hand, if a long dead time is selected the amount of pulses will be under-estimated in case of increased repetition rates [5]. IV. CORONA PULSE POLARITY EVALUATION As previously shown in Fig. 1 corona discharge formation can be separated into two main cluster characteristics which are visually very similar: the Trichel pulse cluster (Fig. 4) and the pre-breakdown streamer cluster (Fig. 5). The location of the origin of corona can be easily determined based on the occurrence of either one of these clusters and considering the external voltage phase and pulse polarity. In Fig. 4a positive pulses can be observed in the negative half of the AC sine wave. This is in contradiction to the 274

assumption that Trichel pulses are caused by electrons flowing between the electrodes which would implicate negative polarity of the pulses. This observation is caused by the measuring circuit, i.e. by the position of the measuring impedance. Measuring impedance in series with coupling capacitor a) Needle - HV, Plane - Grounded b) Plane - HV, Needle - Grounded Measuring impedance in series with test object c) Needle - HV, Plane - Grounded d) Plane - HV, Needle - Grounded Fig. 4: Influence of the measuring impedance and HV source location Trichel pulses Phases I III Measuring impedance in series with coupling capacitor a) Needle - HV, Plane - Grounded b) Plane - HV, Needle - Grounded a) b) Fig. 6: Influence of the measuring circuit to the pulse polarity. V. IMPACT OF FILTER BANDWIDTH SETTINGS ON PD MEASUREMENTS This chapter deals with PD filter settings and their impact on PD recognition and pulse shape. Corona discharge behavior has been used for experimental verification. Special emphasis has been placed on the phenomenon of the pulse-free zone, which is located in the center of the Trichel pulse cluster and which occurs in the third phase of the corona development process described in Section II. PD pulses in the mentioned zone cannot be observed with common partial discharge detectors. In fact, their repetition rate is so high, that common PD analyzers fail to recognize those pulses. It is easiest to explore the theoretical background of this phenomenon in the frequency domain of the PD signals. Fig. 7 illustrates how the continuous frequency spectrum of a single PD pulse event is transformed to the discrete spectrum (Fourier series) of repetitive/periodic pulses with a pulse repetition frequency PRF. A burst of PD pulses (corona) spaced in time at 1/PRF will have a continuous spectrum with peaks regularly spaced at PRF. Measuring impedance in series with test object c) Needle - HV, Plane - Grounded d) Plane - HV, Needle - Grounded Fig. 5: Influence of the measuring impedance and HV source location Pre-breakdown streamers Phase IV Fig. 6a shows the current flowing in the standardized PD measuring setup, where the measuring impedance (AKV) is in series with the coupling capacitor (note that this is the most common setup for PD testing). In the case of Trichel pulses the electron particle current is directed towards the grounded plane (needle is at HV). On the other hand, the corresponding electrical current results in a positive current flow and hence positive pulse polarity at the measuring impedance (see Figs. 4a and 6b). Correct pulse polarity in accordance with the physical origin of the PD pulses can be obtained when the measuring impedance is connected in series with the test object (Fig. 4c). However, depending on the test object this configuration may not be feasible and can be dangerous in case of DUT breakdown. Fig. 7: PD spectrum formation As previously shown corona behavior is characterized by a burst cluster with very high PRF which can reach the limit of 1 MHz for particular cases [7]. The frequency response magnitude of such a burst of pulses exhibits characteristic peaks and troughs defined by the PRF as shown in Fig. 7. For correct quasi-integration of the corresponding PD events the applied PD filter bandwidth must cover one or more peaks of the frequency response. Thus, narrow-band measurements (as indicated by the dark grey bar in Fig. 7) can lead to incorrect and unstable measurement results. The PRF of real PD activity is inherently unstable and therefore narrow-band PD filters will be randomly applied to the peaks and troughs of the measured PD spectrum. In addition, narrow-band measurements suffer 275

from superposition errors of the time-domain signal, which can cause unstable PD readings as well. The interaction of the PD filter bandwidth and the PRF of PD events has been experimentally verified. In the experimental setup a standard oscilloscope (500 MHz bandwidth) was used to record the raw signal data of corona discharges. The raw data is post-processed by a 4 th order Butterworth low-pass filter with various cut-off frequencies. A standard needleplane test arrangement with a 10 mm air-gap was applied. a) Raw corona PD signal b) Zoom to the center of the Trichel pulse cluster (10 µs recording time, six pulses) c) Zoom to the right edge of the Trichel pulse cluster (100 µs recording time, six pulses) d) Single pulse from 5.000 ms to 5.002 ms from Fig 8b Fig. 8: Oscilloscope measurements (0.5 MHz low-pass filter) a) Raw corona PD signal b) Zoom to the center of the Trichel pulse cluster Fig. 9: Oscilloscope measurements (2 MHz low-pass filter) A clear difference is observed between the repetition rate in the center and at the edges of the Trichel pulse cluster. The repetition rate in the center of the Trichel pulse cluster (see Fig. 8b) is ten times higher than at the edge (see Fig. 8c). Hence, PD pulses at the edges of the Trichel pulse cluster pulses are further spaced apart and the oscillations of the filtered output signal are less pronounced (Fig. 8c) than for the case of high repetition rates in the center of the Trichel pulse cluster (Fig. 8b). If the pulse repetition rate is higher than the PD filter bandwidth (i.e. the time lag between single pulses is too small), the filter output is mainly a pure sine wave. This effect prevents correct recognition of the PD pulses. As shown in Fig. 8b the filtered output signal in the center of the Trichel pulse cluster is basically a sine wave with a frequency of 1 MHz. On the other hand, if a single pulse is processed by the filter, the filtered output preserves the general PD pulse shape which enables correct PD pulse recognition by the PD detector. The initial assumption that common PD detectors are unable to observe PD events in the pulse-free zone (as stated at the beginning of this section) must therefore be revised. The occurrence of a pulse- free zone in the center of the Trichel pulse cluster is caused by the PD filter limits imposed by IEC 60270:2000, which requires a maximum lowpass cut-off frequency of 500 khz. As shown in Fig. 9, if the cut-off frequency is increased to 2 MHz the correct PD pulse level can be determined. The latest amendment to IEC 60270 [1] adapts the permitted PD filter settings for wide-band measurements by increasing the maximum low-pass frequency limit to 1 MHz and allowing a maximum measurement bandwidth of up to 900 khz. This modification enhances correct pulse recognition and fulfills the general requirement that the system bandwidth should be higher than the pulse repetition frequency of the recorded PD activity. VI. CONCLUSION The formation and development of corona PD from an initial phase up to the onset of HV breakdown has been explained and described in this paper. Corona PD activity has a distinctive charge-voltage behavior, which is characterized by an initial stage governed by Trichel pulses up to a final stage with its pre-breakdown onset streamers. The origin of corona discharges can be readily determined from the PD pattern formation (burst cluster position) and pulse polarity. The phenomenon of a pulse-free zone in the PD pattern has been explained together with the proper tuning of the partial discharge detector characteristics. The experimental results reveal that narrow-band PD measurements suffer from many limitations when applied to corona discharges. A sufficiently wide bandwidth with respect to the pulse repetition frequency is essential for reproducible and plausible corona PD measurement and evaluation. For reliable and consistent measurement results it is strongly recommended to consider and verify both the time domain signal as well as the frequency response of PD events. The PD detector could even display a warning message when the PRF is too high. REFERENCES [1] IEC 60270: High-voltage test techniques Partial discharge measurements, Consolidated version with amendment 1, Ed. 3.1, 2015 [2] G. W. Trichel, "The Mechanism of the Negative Point to Plane Corona Near Onset," Phys. Rev., Vol. 54, pp. 1078-1084, 1938 [3] P.S. Gardiner, "Some characteristics of negative point-plane corona", Proceedings of the Institution of Electrical Engineers, Vol.125, No.5, pp.467-468, 1978 [4] F.H. Kreuger, "Partial Discharge Detection in High-Voltage Equipment" Butterworth-Heinemann, London, 1989 [5] C. H. Stuckenholz, M. Gamlin, P. Mraz,"PD Performance of UHV-DC Test Equipment",Proceedings of the 19th International Symposium on High Voltage Engineering, ISH 2015, Pilsen, Czech Republic, 2015 [6] Haefely Test AG, " DDX 9121b Partial Discharge Detector", Operating Manual, Version 6.1 [7] T. Pierce, "An Experimental investigation of negative point-plane corona and its relation to ball lighting", Technical Report, RAD-TR-60-29, United States Air Force, Massachusetts, 1960 276

The original version of this article was published in CMD 2016 proceedings: The international conference on Condition Monitoring and Diagnosis 2016, Xi'an, China, 2016 www.haefely-hipotronics.com Haefely Test AG Birsstrasse 300 4052 Basel Switzerland + 41 61 373 4111 + 41 61 373 4912 sales@haefely.com Haefely Test AG Representative Beijing Office 8-1-602, Fortune Street No. 67, Chaoyang Road, Chaoyang District Beijing, China 100025 + 86 10 8578 8099 + 86 10 8578 9908 sales@haefely.com.cn Hipotronics, Inc. 1650 Route 22 N Brewster, NY 10509 United States + 1 845 279 3644 + 1 845 279 2467 sales@hipotronics.com HAEFELY HIPOTRONICS has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice.