X3D in Radiation Therapy Procedure Planning. Felix G. Hamza-Lup, Ph.D. Computer Science Armstrong Atlantic State University Savannah, Georgia USA

Similar documents
Web based 3D Planning Tool for Radiation Therapy Treatment

IQM Detector Characteristics: Signal reproducibility

Mobius3D. Software based IMRT QA

LINEAR ACCELERATOR. Buyer's Guide. Version 1.1

A positioning QA procedure for 2D/2D (kv/mv) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup

CHAPTER 2 COMMISSIONING OF KILO-VOLTAGE CONE BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED RADIOTHERAPY

Initial setup and subsequent temporal position monitoring using implanted RF transponders

PHYSICS QUESTIONNAIRE FORM

Sub-mm accuracy of accelerators: How manufacturers achieve it, how physicists verify it

COMPREHENSIVE TG-142 IMAGING AND MACHINE QA

The Current State of EPID-Based Linear Accelerator Quality Assurance. Disclosures. Purpose of this First Talk 8/3/2017

ISPFILMQATM STATE-OF-THE-ART RADIOTHERAPY VERIFICATION SOFTWARE. Supports all major radiotherapy technologies! FilmQA TM

3D Diode Array Commissioning: Building Confidence in 3D QA Technology

8/3/2016. The EPID Strikes Back. Novel Applications for Current EPID Technology. Joerg Rottmann, PhD. Disclosures and acknowledgements

Emerging Technology: Real-Time Monitoring of Treatment Delivery EPID Exit Dose QA

Quality Assurance Results for a Commercial Radiosurgery System: A Communication

Evaluation of dosimetry parameters of photons and electron beams using a linear ionization chamber array

ArcCHECK. The Ultimate 4D QA Solution. Your Most Valuable QA and Dosimetry Tools

GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications

Volumetric Modulated Arc Therapy. David Shepard Swedish Cancer Institute Seattle, WA

Nathan Childress, Ph.D., DABR

Development of a Virtual Simulation Environment for Radiation Treatment Planning

Characterization, Commissioning and Evaluation of Delta 4 IMRT QA System. Ram Sadagopan 1 UTMD Anderson Cancer Center Houston, TX.

HAPTICS AND EXTENSIBLE 3D IN WEB-BASED ENVIRONMENTS FOR E-LEARNING AND SIMULATION

The Ultimate 4D QA Solution A 4D isotropic cylindrical detector array for arc delivery QA and Dosimetry.

Web3D Consortium Medical WG Update. Nicholas F. Polys, PhD Virginia Tech Web3D Consortium

Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA

8/3/2017. Use of EPIDs for Non-Routine Linac QA. Disclosure. Learning Objectives. Parts of this project received support from Varian Medical System.

7/23/2014. Acknowledgements. Implementing a new digital medical accelerator. New Generation of Medical Accelerators

Isocenter and Field of View Accuracy Measurement Software for Linear Accelerator

Distributed source x-ray tube technology for tomosynthesis imaging

A Generalized Strategy for 3D Dose Verification of IMRT/VMAT Using EPID-measured Transit Images

SRS MapCHECK. SRS Patient QA, No Film. Your Most Valuable QA and Dosimetry Tools

Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

MOVING LASER SYSTEMS IN RT

ArcCHECK, ein neuartiger QS-Ansatz bei der Rotationsbestrahlung

Addressing Limitations of a Spatially Sensitive Large-Area Ion Chamber for Real-Time Verification of Intensity Modulated Radiation Therapy.

A diagnostic tool for basic daily quality assurance of a tomotherapy Hi Art machine

University of Wollongong. Research Online

160-slice CT SCANNER / New Standard for the Future

QUALITY CONTROL PHANTOMS FOR RADIOTHERAPY AND MEDICAL IMAGING

Accuracy of SRS dose delivery using the TomoTherapy Hi-Art System

specifications Novalis Tx image-guided radiosurgery linear accelerator

Beam Commissioning and Annual QA Phantoms, Detectors & Accessories. iba-dosimetry.com

Aperture Based Inverse Planning AAPM Summer School 2003

CyberKnife Iris Beam QA using Fluence Divergence

Laser Systems for Patient Alignment

IN THE UNITED STATES DISTRICT COURT FOR THE DISTRICT OF DELAWARE ) ) ) ) ) ) ) ) ) ) ) COMPLAINT FOR PATENT INFRINGEMENT

SRS MapCHECK. SRS Patient QA, No Film. Your Most Valuable QA and Dosimetry Tools

Four-dimensional in vivo dosimetry by dose reconstruction using continuous EPID images and phase sorting method. JiHyung Yoon.

Phantoms in Medical Physics (RT) U. Oelfke. Division of Radiotherapy & Imaging

IMRT Delivery System QA. IMRT Dose Delivery. Acceptance testing. Why: specific tests for IMRT? Accuracy of leaf positioning (gaps) MLC Alignment

Diagnostic X-Ray Shielding

BRANDON RICE UNIVERSITY OF FLORIDA

Commissioning and Calibrating a Linear Accelerator State-of-the-Art in 2010

Characterization of an in vivo diode dosimetry system for clinical use

The VARIAN 250 MeV Superconducting Compact Proton Cyclotron

ArcCHECKTM. The Ultimate 4D QA Solution. Your Most Valuable QA and Dosimetry Tools. VMAT RapidArc TomoTherapy Pinnacle 3 SmartArc Conventional IMRT

Nancy G. Leveson and Clark S. Turner, An Investigation of the Therac-25 Accidents. Computer 26(7), pp , Jul Presented by Dror Feitelson

DOSELAB TOMOTHERAPY TG-148 QA QUICK GUIDE TG-148 RECOMMENDED TESTS 1. V.B.1.C. - Y-JAW DIVERGENCE/BEAM CENTERING

Application of STPA in Radiation Therapy: a Preliminary Study

Table 1: Available X-ray Beam Energy Combinations (MV) 6 10/ Yes Yes 6 16/15 6 Yes No 6 23/18 6 Yes No 6 25/20 6 Yes No

Gantry design and experience at PSI

Evaluation of a diode array for QA measurements on a helical tomotherapy unit

An Activity in Computed Tomography

3D Brachytherapy with Afterloading Machines

CHAPTER 6 QUALITY ASSURANCE OF VARIAN ON-BOARD IMAGER

TOMOTHERAPY H SERIES TomoH, TomoHD and TomoHDA Systems Technical Specifications

HITACHI Proton Therapy System with Spot Scanning

Quality Control for Stereotactic Breast Biopsy. Robert J. Pizzutiello, Jr., F.A.C.M.P. Upstate Medical Physics, Inc

Determination of the tube voltage from clinic mammographic system using two types of detectors

Commissioning. Basic machine performance MLC Dose rate control Gantry speed control End-to-end tests

A feasibility study of using conventional jaws to deliver IMRT plans in the treatment of prostate cancer *

A Guide to Radiochromic Film Dosimetry with EBT2 and EBT3

Performance evaluation of the RITG148 + set of TomoTherapy quality assurance tools using RTQA 2 radiochromic film

END-TO-END TESTING OF THE LEKSELL GAMMA KNIFE ICON SYSTEM

Automated dose control in multi-slice CT. Nicholas Keat Formerly ImPACT, St George's Hospital, London

International Journal of Advance Engineering and Research Development

X-RAD SmART (Small Animal RadioTherapy) IMAGE GUIDED BIOLOGICAL IRRADIATOR Technical Specifications (updated March 2015)

Development of Embedded based Anti-Collision Technique for Medical LINAC (Linear Accelerator) Machine

Commissioning and validation of BrainLAB cones for 6X FFF and 10X FFF beams on a Varian TrueBeam STx

An Activity in Computed Tomography

A new approach to measure dwell position inaccuracy in HDR ring applicators quantification and corrective QA

Aim. Images for this section: Page 2 of 13

Virtual Reality: a way to prepare and optimize operations in decommissioning projects

Installation und Kommissionierung des Viewray MRIdian Linac Hamburg, 28. Mai 2018 Sebastian Klüter

MR3T LASER SYSTEMS IN RT ESSENTIAL FOR PRECISE PATIENT ALIGNMENT

State of the Art Film Dosimetry

Electronic Brachytherapy Sources. Thomas W. Rusch

SUBCHAPTER 14. THERAPEUTIC INSTALLATIONS

Characterization and evaluation of an integrated quality monitoring system for online quality assurance of external beam radiation therapy

A Fast Monolithic System for Proton Imaging. Fritz DeJongh ProtonVDA Inc October 2017

Laser Installation Engineers, CT Room Designers and Contractors

SUN NUCLEAR. EPIDose : An Overview of EPIDose and the EPIDose Process and Algorithm. corporation. Your Most Valuable QA and Dosimetry Tools

Imagine your future lab. Designed using Virtual Reality and Computer Simulation

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

Rotational total skin electron irradiation with a linear accelerator

High Energy Digital Radiography & 3D-CT for Industrial Systems

ISO Cube Daily QA Package

Transcription:

X3D in Radiation Therapy Procedure Planning Felix G. Hamza-Lup, Ph.D. Computer Science Armstrong Atlantic State University Savannah, Georgia USA

Outline 1. What is radiation therapy? 2. Treatment planning issues 3. Web-3D & the treatment plan 4. The 3DRTT web-based simulator 5. Assessment plan 6. Near future

What is Radiation Therapy? Radiation therapy is the careful use of highenergy radiation to treat cancer. About 50-60% of cancer patients are treated with radiation at some time during their disease (www.radiologyinfo.org) A radiation oncologist may use: radiation generated by a machine outside a patient's body (external beam radiation therapy) EBRT radioactive sources that are put inside the patient (brachytherapy)

Cell Killing By Ionizing Radiation Radiation destroys the cancer cells' ability to reproduce and the body naturally gets rid of these cells.

Planning Calibration of radiation sources Planning of patient procedures Calculation of patient dose (dosimetrists)

General Flow of External Radiation Therapy Treatments CT scanner Linac: external beam treatment CT Slices + Radiation Therapy (RT) info Treatment Planning System (TPS): dose calculation and visualization Record and Verify System (RV): makes sure all parameters are properly transferred to/from linac

LINACS (Novalis ) LINear ACcelerator main components

LINACS (Varian Trilogy ) KV Source KV Detector MV Detector

Planning issues Hardware Collisions Beam intersection with external objects

A typical situation from our clinic MD Anderson Cancer Center Orlando Novalis 7-field H&N RT needs a new paint job! Beam Parameters: In many cases the collimator is touching the couch, and re-planning is required Gantry = 245 o Couch = 350 o Collimator = 0 o VRT = 10.0 LAT = 0.0 LNG = 60

There are many add-ons we need to keep track off and avoid collision with stereotactic head frames breast boards head extensions wing boards

Motivation Most of the currently available treatment planning systems offer little or no information for the treatment planner on possible collision scenarios during the planning process Most collision scenarios are found by RTTs during visual treatment verification checks Computer Controlled Radiation Therapy (CCRT) requires precise knowledge of the relative positions of all linac components with respect to the patient and to each other. All motions must be verified before use

Motivation We would like to: 1. Generate a realistic 3D simulation of the treatment room with as much detail and resolution as possible? 2. Virtually move different linac components gantry, table, collimator,..etc as if you were in the room using a hand pendant? 3. Visualize the beam path, the lasers, and the actual patient external geometries/surfaces on the couch together with add-on/immobilization devices? If we can, then we have a tool that provides simulation of patient-specific external beam plans.

3DRTT Simulator - 3D Radiation Therapy Treatment: Varian Trilogy 23ix

Varian Trilogy & Novalis (BrainLab )

Patient specific data Patient specific CT data in the simulator

Implementation EcmaScript Java (JSP/servlet) X3D X3D Model response Server (JSP) (Tomcat) Web-page request Browser/X3D Player

3DRTT Simulator Features: 1. Web-based simulator (using latest X3D technology standards) 2. Friendly GUI (Graphical User Interface) 3. Easy setup and is platform independent 4. Uses freely available software components (web browser, x3d player) 5. To experience immersive 3D visualization use red/blue glass pair or shutter glasses

3DRTT Simulator - Assessment

More on accuracy Measurements (~ 1.5 cm) in the real environment in the virtual environment (simulator)

Conclusions The simulation tool allows for accurate 3D representation of the all linac components and allows the user to perform virtual 3D simulation of the delivery. The current version allows for visual detection of collision scenarios to within a few centimeters average accuracy With increased model resolution including add-on devices and patient-specific external contour volumetric data, the tool may serve as a verification check for CCRT deliveries. The tool can be used as a training tool for RTTs, dosimetrists, and physics residents

Acknowledgments Ivan Sopin, Dan Lipsa, Omar Zeidan M.D. Anderson Cancer Center Orlando, Florida.

Thank you hyperion.armstrong.edu:8080/3drtt