Single Channel Loop Detector

Similar documents
Single Channel Loop Detector

Single Channel Loop Detector

Single Channel Loop Detector

Single Channel Loop Detector

RME1-RME1BT INSTRUCCIONES DE INSTALACION INSTALLATIEVOORSCHRIFTEN INSTRUCTIONS D INSTALLATION ИНСТРУКЦИИ ПО УСТАНОВКЕ ISTRUZIONI DI INSTALLAZIONE

FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR

Short form User Manual

AGP-0230 USER MANUAL AMANO

USER MANUAL ULD 910. October 2003 Revision: 03. Single Channel Vehicle Detector ULD 910. Part Number: MIC

PD132 Loop Detector Specification

Dual Channel Vehicle Detector ULD 920 USER MANUAL Part Number: MIC ULD 920

BEA s digital inductive single loop solution

USERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS

USERS GUIDE MATRIX P/N SINGLE DIGITAL INDUCTIVE LOOP SENSOR

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

ULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

MD12-2 Metal Loop Detector

Single Channel Loop Vehicle detector User Manual

ULT-DIN O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

601/602 Series Inductive Loop Detector

Operating Instructions

TECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM

DSP-10 Vehicle Detector

SMARTSCAN INFORMATION

DSP-21 Directional Counting Detector

MODEL T-110 SERIES OPERATION MANUAL

DSP-20 Dual Channel Vehicle Detector With Directional Logic

MATRIX INDUCTIVE LOOP CONTROL BOX

Operating Instructions

With Audible Detect Signal

PD230 Enhanced Vehicle Detector USER MANUAL

Operations Manual. Model NT11 & NT11-E. June 18 th 2002

FG2 TWO-CHANNEL DETECTOR

LMD622 and LMD624 Series

Four Channel Inductive Loop Detector

Inductive Loop Detector

SPECIAL SPECIFICATION 6004 Digital Card Rack Inductive Loop Detector Assembly

Dual Channel Traffic/Parking Detector User Guide

SOUTH DUBLIN COUNTY COUNCIL Traffic Management Centre Roads (Traffic and Transportation) Department

Underground Loops and Loop Detectors. DoorKing Plug-In Loop Detectors and Loop Accessories Single Channel CH1

Single Channel Loop Detector

Double Channel Loop Detector

FACTORY AUTOMATION. MANUAL LC10-* Laying loops for Loop detector LC10-1 and LC10-2

MODEL C-1000 SERIES OPERATION MANUAL

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

MODEL L-1200 SERIES OPERATION MANUAL

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

INSTRUCTION MANUAL DAAB LOOP DETECTOR DB402

SET Installation and Operating Instructions. Level switch for two sensors

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL

Loop Installation. Manual

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

REPAIRING THE RM KL400 LINEAR AMPLIFIER.

OPERATING INSTRUCTION

ECM3 EARTH CONTINUITY RELAY

BlockMon Block Monitor LongMon Long Monitor

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

Using the EVM: PFC Design Tips and Techniques

USER'S MANUAL DMR-6700

T25-35SA Subaudible Tone Decoder

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

ITS specification Inductive loops and feeder cables (ITS-03-01)

ENCOUNTER AMPLIFIER MANUAL EN-1502 EN-3001 EN-3004

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

05/09/2012

NEXUS Metal Detectors. Telephone +44(0) User Manual

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

MODEL P-1400 OPERATION MANUAL Firmware Version 4.02

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

User and Reference Guide Hy5B Vehicle Detector: MX4125

Bi-Directional DC Motor Speed Controller 5-32Vdc (3166v2)

E-STOP relays, safety gate monitors

SLIM COMPACT SAFETY RELAY

ULTRA LOW PROFILE 2 A POLARIZED RELAY. mm inch. Initial breakdown voltage

Inductive Proximity Sensor

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Ness MCR Multi-Channel Radio Receiver

Level Lance Model 5100

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

The wireless alternative to expensive cabling...

USER MANUAL D-CLASS AMPLIFIER CA-DA12250 CA-DA41400 CA-DA Specifications and design are subject to change without notice

Track Circuit Systems Products

Mat 100w/150w/200w LIFETIME INSTALLATION MANUAL WARRANTY

12V MINI AUDIO-FREQUENCY INDUCTION LOOP AMPLIFIER

BARRETT. 911 Automatic antenna tuner Installation instructions. General. Specifications COMMUNICATIONS

Proximity Sensor Terminology

Impulse system MPT 700. Manual Edition GB

DEIF A/S. Insulation monitor. Type SIM-Q

Solid State Relays Industrial, 1-Phase ZS, Standard Range Types RA /RA /RA

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

BL0932. BL0932 Application Note

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

USERS GUIDE EAGLE SMR MOTION SENSOR

E-STOP relays, safety gate monitors

Loop Installation. Manual.

Capacitance Level Switch

Transcription:

Single Channel Loop Detector Model - LD106 Series The LD106 is an ultra low power single channel inductive loop detector designed for parking and access control applications. The LD106 can be configured for low power for operation from a battery or solar panel. The detector consumes less than 2mA of supply current when there is no vehicle on the loop. The detector is connected to an inductive loop mounted in the road surface. When vehicles pass over the loop the detector switches on an output. The use of microprocessor and surface mount technology enables a large number of functions to be incorporated into a small package. The LD106 is easy to set-up and install. Applications Typical applications in the parking and access control environments are safety loops for barriers or gates, arming loops for activating card dispensers, entry or exit loops and vehicle counting. Features Reset Switch. Pressing the reset switch enables the detector to be manually reset during commissioning and testing. This results in the detector re-tuning the sensing loop and becoming ready for vehicle detection. The reset switch should be operated every time any of the switch settings are changed. Switch selectable Sensitivity. The detect sensitivity is the minimum change in inductance required to produce a detect output. (%ΔL/L). Four sensitivity settings are available on the switches to allow flexibility in configuration. Switch selectable Frequency. The frequency of the loop is determined by the inductance of the loop and the frequency switch setting. If the frequency switch is on, the frequency is reduced. It may be necessary to change the frequency to prevent cross-talk between adjacent loops on different detectors. Sensitivity Boost. This feature sets the undetect level to maximum sensitivity and is used to prevent loss of detection of high-bed vehicles. Filter Option. This option is used to provide a delay of 2 Seconds between detection of the vehicle and switching of the output relay. This delay is normally used to prevent false detection of small or fast moving objects. 1

Permanent Presence. This feature ensures detection of the vehicle will be maintained when the vehicle is parked over the loop for extended periods. Not enabled in low power mode. Pulse Relay Selection. The Presence relay may be configured as a pulse relay and to energise on detection of a vehicle or to energise when the vehicle leaves the loop. Selectable Pulse Time. This feature sets the length of time that the pulse relay will be energised. 1 Second or 0.2 Second. Low Power Option. When switched on this feature puts the detector into low power mode. Indicators Detect Indicator. This LED Indicator is illuminated when there is a vehicle over the loop or the loop is faulty. This LED can also be used to determine the loop frequency. On reset, count the number of times the LED flashes. Multiply this number by 10KHz.For example: if the LED flashes 6 times, then the loop frequency is between 60KHz and 70KHz. The detect led will periodically flash on for short period of time to indicate that the detector is operating correctly. Technical Specifications Power supply Supply Current (Approximate values) 10 50 VDC 8 35 VAC 50/60Hz Normal mode: Low Power mode: Un detect 11mA In Detect 15mA Un detect 1.5mA In Detect 6mA Relay Response time Indicators Detector tuning range Loop Frequency Environmental tracking Protection Connector Dimensions Operating Temperature Storage Temperature Change over contact 0.5A/220VAC (normally energized) Normal mode: Approximately 120ms after vehicle enters loop. Low power mode: Approximately 1sec after vehicle enters loop. LED indicators show: Power/ Detect state. 15-1500uH Approx. 23 130KHz Automatic Compensation Loop isolation transformer with zener diodes and gas discharge tube. 8 Way Screw terminal block. 105mm X 90mm X 22mm -40 C to +80 C -40 C to +85 C 2

Switch Settings LD113 Switch Settings Switch No. Function ON OFF 10 Frequency Low High 8,9 Sensitivity Hi (0.02%) - S8/S9 8,9 Sensitivity Med Hi (0.05%) S9 S8 8,9 Sensitivity Med Lo (0.1%) S8 S9 8,9 Sensitivity Lo (0.5%) S8/S9-7 Pulse Mode Undetect Detect 6 Relay Mode Pulse Presence 5 ASB On Off 4 Filter 2 Sec Off 3 Pulse Time 1 Sec 0.2 Sec 2 Permanent Presence On Off 1 Power Mode Low Normal Relay Functionality RELAY VEHICLE PRESENT NO VEHICLE LOOP FAULTY NO POWER PRESENCE RELAY PULSE RELAY N/O CLOSED OPEN OPEN OPEN N/C OPEN CLOSED CLOSED CLOSED N/O PULSE CLOSED OPEN OPEN OPEN N/C PULSE OPEN CLOSED CLOSED CLOSED 3

Diagnostics SYMPTOM POSSIBLE CAUSE SOLUTION The detect led does not flash very slowly. No power supply voltage on the input. Check that the power supply is correctly wired to the detector. (Terminals 4 and 5) The DETECT LED flashes erratically. The DETECT LED randomly stays on. The DETECT LED is flashing. There may be a poor connection in the loop or loop feeder. The detector may be experiencing crosstalk with the loop of an adjacent detector. Faulty loop or loop feeder wiring. Movement of the loop in the ground. The loop inductance is to small or the loop is short circuit. Check all wiring. Tighten screw terminals. Check for broken wires. Try changing frequencies using the frequency switch. Put the detector with the larger loop onto low frequency and the detector with the smaller loop onto high frequency. Check the wiring. Tighten screw terminals. Check for pinched or bent wires. Is the feeder wire twisted? Check for cracks in the road surface near the loop. Check that there is no short circuit on the loop feeder wiring or the loop. If there is no short circuit then the inductance is to small and more turns of wire should be added to the loop. The loop inductance is too large or the loop is open circuit. Check that there is electrical continuity on the loop. This can be done using a multimeter on the ohms range (< 5 Ω). If the loop inductance is too large then try reducing the number of turns. 4

1 2 3 4 5 6 7 8 9 10 Wiring Diagram 8 7 RELAY OUTPUT 6 LOOP TWISTED 1 2 LOOP INPUT 12/24 VAC/DC EARTH 4 5 3 POWER INPUT Wiring Connections 1 LOOP TWISTED 2 LOOP WIRE 3 EARTH 4-12 TO 24VAC/DC SUPPLY 5 + 12 TO 24VAC/DC SUPPLY 6 Relay COM 7 Relay N.C. 8 Relay N.O. Mechanical Layout NOTE: To ensure correct operation of the LD106, the detector must be securely mounted using the 4 mounting holes. LD106 1 MODE SWITCH 94 mm 8 TERMINALS RESET SWITCH DETECT 42 mm 5

Loop Installation Guide 1. The detector should be installed in a waterproof housing as close to the loop as possible. 2. The loop and feeder should be made from insulated copper wire with a minimum cross-sectional area of 1.5mm 2. The feeder should be twisted with at least 20 turns per metre. Joints in the wire are not recommended and must be soldered and made waterproof. Faulty joints could lead to incorrect operation of the detector. Feeders which may pick up electrical noise should use screened cable, with the screen earthed at the detector. 3. The loop should be either square or rectangular in shape with a minimum distance of 1 metre between opposite sides. Normally 3 turns of wire are used in the loop. Large loops with a circumference of greater than 10 metres should use 2 turns while small loops with a circumference of less than 6 metres should use 4 turns. When two loops are used in close proximity to each other it is recommended that 3 turns are used in one and 4 turns in the other to prevent cross-talk. 4. Cross-talk is a term used to describe the interference between two adjacent loops. To avoid incorrect operation of the detector, the loops should be at least 2 metres apart and on different frequency settings. 5. For loop installation, slots should be cut in the road using a masonry cutting tool. A 45 o cut should be made across the corners to prevent damage to the wire on the corners. The slot should be about 4mm wide and 30mm to 50mm deep. Remember to extend the slot from one of the corners to the road-side to accommodate the feeder. 6. Best results are obtained when a single length of wire is used with no joints. This may be achieved by running the wire from the detector to the loop, around the loop for 3 turns and then back to the detector. The feeder portion of the wire is then twisted. Remember that twisting the feeder will shorten its length, so ensure a long enough feeder wire is used. 7. After the loop and feeder wires have been placed in the slot, the slot is filled with epoxy compound or bitumen filler. TRAFFIC DIRECTION 300mm 300mm ROAD SURFACE 1M ROAD EDGE SLOT SEALANT WIRES 30-50 mm 45 O CROSSCUT FEEDER 4mm Contact Details Refer to our web site for distributor details. Email: proconel@proconel.com Web: www.proconel.com 6