The Ultimate 4D QA Solution A 4D isotropic cylindrical detector array for arc delivery QA and Dosimetry.

Similar documents
ArcCHECK. The Ultimate 4D QA Solution. Your Most Valuable QA and Dosimetry Tools

ArcCHECKTM. The Ultimate 4D QA Solution. Your Most Valuable QA and Dosimetry Tools. VMAT RapidArc TomoTherapy Pinnacle 3 SmartArc Conventional IMRT

3D Diode Array Commissioning: Building Confidence in 3D QA Technology

SRS MapCHECK. SRS Patient QA, No Film. Your Most Valuable QA and Dosimetry Tools

ArcCHECK, ein neuartiger QS-Ansatz bei der Rotationsbestrahlung

SRS MapCHECK. SRS Patient QA, No Film. Your Most Valuable QA and Dosimetry Tools

Commissioning. Basic machine performance MLC Dose rate control Gantry speed control End-to-end tests

Emerging Technology: Real-Time Monitoring of Treatment Delivery EPID Exit Dose QA

PHYSICS QUESTIONNAIRE FORM

SUN NUCLEAR. EPIDose : An Overview of EPIDose and the EPIDose Process and Algorithm. corporation. Your Most Valuable QA and Dosimetry Tools

Evaluation of a diode array for QA measurements on a helical tomotherapy unit

Development of the Use of Amorphous Silicon (ASi) Electronic Portal Imaging Devices as a Physics Tool for Routine Linear Accelerator QA

7/23/2014. Acknowledgements. Implementing a new digital medical accelerator. New Generation of Medical Accelerators

The Current State of EPID-Based Linear Accelerator Quality Assurance. Disclosures. Purpose of this First Talk 8/3/2017

Characterization, Commissioning and Evaluation of Delta 4 IMRT QA System. Ram Sadagopan 1 UTMD Anderson Cancer Center Houston, TX.

Isocenter and Field of View Accuracy Measurement Software for Linear Accelerator

A Generalized Strategy for 3D Dose Verification of IMRT/VMAT Using EPID-measured Transit Images

ISPFILMQATM STATE-OF-THE-ART RADIOTHERAPY VERIFICATION SOFTWARE. Supports all major radiotherapy technologies! FilmQA TM

COMPREHENSIVE TG-142 IMAGING AND MACHINE QA

8/3/2017. Use of EPIDs for Non-Routine Linac QA. Disclosure. Learning Objectives. Parts of this project received support from Varian Medical System.

Monica Kishore. Medical Physics Graduate Program Duke University. Approved: Jennifer O Daniel, Co-Supervisor. Fang-Fang Yin, Co-Supervisor

Volumetric Modulated Arc Therapy. David Shepard Swedish Cancer Institute Seattle, WA

IMRT Delivery System QA. IMRT Dose Delivery. Acceptance testing. Why: specific tests for IMRT? Accuracy of leaf positioning (gaps) MLC Alignment

Sensitivity study of an automated system for daily patient QA using EPID exit dose images

IQM Detector Characteristics: Signal reproducibility

Commissioning and Calibrating a Linear Accelerator State-of-the-Art in 2010

The most Comprehensive, Reliable, Economical and Easy to use GAFCHROMIC film based RT QA system Updated Feb 08 BUSINESS UNIT OF ISP

Initial Experience with a Commercial System for Volumetric Analysis of Patient Specific QA. Katja Langen Mariana Guerrero Shifeng Chen Shh..

Mobius3D. Software based IMRT QA

DOSELAB TOMOTHERAPY TG-148 QA QUICK GUIDE TG-148 RECOMMENDED TESTS 1. V.B.1.C. - Y-JAW DIVERGENCE/BEAM CENTERING

Monte Carlo study on a new concept of a scanning photon beam system for IMRT

Evaluation of dosimetry parameters of photons and electron beams using a linear ionization chamber array

Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method

8/3/2016. The EPID Strikes Back. Novel Applications for Current EPID Technology. Joerg Rottmann, PhD. Disclosures and acknowledgements

When small things matter. Small Field Dosimetry Application Guide

A 2-D diode array and analysis software for verification of intensity modulated radiation therapy delivery

Installation und Kommissionierung des Viewray MRIdian Linac Hamburg, 28. Mai 2018 Sebastian Klüter

Aperture Based Inverse Planning AAPM Summer School 2003

CHAPTER 2 COMMISSIONING OF KILO-VOLTAGE CONE BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED RADIOTHERAPY

A positioning QA procedure for 2D/2D (kv/mv) and 3D/3D (CT/CBCT) image matching for radiotherapy patient setup

QA Considerations. QA for LGK Perfexion : : Follow NRC licensing guidelines (10( CFR ) Leksell Gamma Knife Perfexion

Pixel response-based EPID dosimetry for patient specific QA

Four-dimensional in vivo dosimetry by dose reconstruction using continuous EPID images and phase sorting method. JiHyung Yoon.

Performance evaluation of the RITG148 + set of TomoTherapy quality assurance tools using RTQA 2 radiochromic film

Beam Commissioning and Annual QA Phantoms, Detectors & Accessories. iba-dosimetry.com

GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications

Beam Production, Characteristics and Shaping

Intensity-modulated radiation therapy dose verification using fluence and portal imaging device

A diagnostic tool for basic daily quality assurance of a tomotherapy Hi Art machine

A proposed method for linear accelerator photon beam steering using EPID

TOMOTHERAPY H SERIES TomoH, TomoHD and TomoHDA Systems Technical Specifications

Phantoms in Medical Physics (RT) U. Oelfke. Division of Radiotherapy & Imaging

Gantry angle determination during arc IMRT: evaluation of a simple EPID-based technique and two commercial inclinometers

The evaluation of minimum detectable phantom thickness change using a scanning liquid filled ion chamber EPID dose response

Stability of the Helical TomoTherapy Hi Art II detector for treatment beam irradiations

Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy

Comparison of peripheral dose measurements using Ionization chamber and MOSFET detector

Cylindrical Ion Chambers

Cylindrical Ion Chambers Victoreen Model 550 Series

CyberKnife Iris Beam QA using Fluence Divergence

ISO Cube Daily QA Package

Nuclear Associates

A Guide to Radiochromic Film Dosimetry with EBT2 and EBT3

Impact of energy variation on Cone Ratio, PDD10, TMR20 10 and IMRT doses for flattening filter free (FFF) beam of TomoTherapy Hi-Art TM machines

Effect of slit scan imaging techniques on image quality on radiotherapy electronic portal imaging

SCINTILLATING FIBER DOSIMETER ARRAY

Conflict Disclosure. Rotational IMRT. Arc therapy. Dynamic Arc therapy. Intensity Modulated Arc Therapy Principles and Perspectives

State of the Art Film Dosimetry

QUALITY CONTROL PHANTOMS FOR RADIOTHERAPY AND MEDICAL IMAGING

Electronic Brachytherapy Sources. Thomas W. Rusch

DETECTORS UNCOMPROMISING QUALITY. The standard in dosimetry measurements for over 40 years. EXRADIN DETECTORS

Nathan Childress, Ph.D., DABR

An Introduction to TG-142 Imaging QA Using Standard Imaging Products. Mark Wiesmeyer, PhD, DABR Technical Product Manager Standard Imaging, Inc.

Characterization and evaluation of an integrated quality monitoring system for online quality assurance of external beam radiation therapy

Characterization of an in vivo diode dosimetry system for clinical use

X3D in Radiation Therapy Procedure Planning. Felix G. Hamza-Lup, Ph.D. Computer Science Armstrong Atlantic State University Savannah, Georgia USA

Comparative performance evaluation of a new a-si EPID that exceeds quad high-definition resolution

LINEAR ACCELERATOR. Buyer's Guide. Version 1.1

2010 Philips BrightView XCT SPECT/CT

The Versatile and Powerful ACLxy. ACLxy

TOMOHD. Product Specifications

Clinical experience with EPID dosimetry for prostate IMRT pre-treatment dose verification

Improvements in dose calculation accuracy for small off-axis targets in high dose per fraction tomotherapy

Beam Analysis BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers. Disruptive Technology

An Activity in Computed Tomography

University of Wollongong. Research Online

2D, 3D CT Intervention, and CT Fluoroscopy

Initial setup and subsequent temporal position monitoring using implanted RF transponders

Accuracy of rapid radiographic film calibration for intensity-modulated radiation therapy verification

Nuclear Associates , , CT Head and Body Dose Phantom

Distributed source x-ray tube technology for tomosynthesis imaging

Devices & Services Company

C a t p h a n. T h e P h a n t o m L a b o r a t o r y. Ordering Information

A new approach to film dosimetry for high energy photon beams: Lateral scatter filtering

Laser Systems for Patient Alignment

QC Testing for Computed Tomography (CT) Scanner

A feasibility study of using conventional jaws to deliver IMRT plans in the treatment of prostate cancer *

Data Acquisition Systems design for Quality Assurance in advanced radiation dosimetry

Beam Delivery Techniques: Passive Scattering Proton Beams. Zuofeng Li and Roelf Slopsema University of Florida Proton Therapy Institute

Department of Physics, State University of New York at Buffalo, Buffalo NY, USA

Transcription:

The Ultimate 4D QA Solution A 4D isotropic cylindrical detector array for arc delivery QA and Dosimetry. U.S.Patent No. 8,044,359; 6,125,335 Your Most Valuable QA and Dosimetry Tools

2 Y o u r M o s t V a l u a b l e Q A a n d D o s i m e t r y T o o l s

Benefits 4D Patient plan QA RapidArc, VMAT, TomoTherapy, and SmartArc Conventional IMRT and 3D Conformal 4D array worldwide market share leader Patient Dose and Dose Volume Histogram analysis (3DVH Option) Machine QA in rotational mode Tests for MLC, flatness, symmetry, starshot SunPoint Diode Detectors Smallest detector (0.0000019cm) Highest sensitivity Proven stability Consistent BEV for all gantry angles Measure composite dose, and control point ranges ArcCHECK is the world s first true 4D detector array, cylindrical detector array, and electronic array designed specifically for rotational dosimetry. Compatible With FFF Beams TomoTherapy VMAT Pinnacle 3 SmartArc RapidArc Conventional IMRT Testimonial We are using the ArcCHECK for about a year now for QA of our clinical IMRT plans. On the basis of our experiences we can conclude that the ArcCHECK is not only suitable for the QA of Elekta Linacs, but also for small stereotactic fields (up to 3x3 mm 2 ) from a Novalis Linac (Brainlab). Dr. Paul Rietveld, Ph.D. Radiotherapiecentrum The Netherlands Measurement of every pulse Versatile cavity for detector inserts Ease Of Use Single power/data cable Manages all power and data in one connection Integrated electronics ArcCHECK is self-contained with no electronics to setup separately; and unlike 2D arrays, a separate phantom is not needed Lightweight (16kg) ArcCHECK is easily portable for daily use without the need for a separate cart Easy setup Leveling LED s provide real-time feedback on device rotation and tilt for a precise and easy setup Patented user calibration Clinically proven wide field calibration (WFC) takes only 30 minutes and does not require disassembly of the ArcCHECK device No pre-irradiation No pre-irradiation or warm-up required for absolute dose measurements www.sunnuclear.com 3

time/angle/dose The ArcCHECK detector geometry is that of a cylinder, where the detectors spiral down the cylinder. ArcCHECK s 3D shape is unique among detector arrays and offers three key benefits: Maximize detector distribution for each beam angle Minimize detector shadowing for each beam angle Minimize angular dependence for each beam angle time/angle/dose 7.20 Single Diode Reading 186.0 185.5 6.20 185.0 dose [cgy] 5.20 4.20 angle dose 184.5 184.0 183.5 183.0 angle [deg] 3.20 182.5 2.20 182.0 181.5 time/angle/dose 1.20 200 250 300 350 400 450 500 550 600 650 700 750 time [ms] 181.0 The ArcCHECK measures each pulse and records all measurement data in 50ms intervals. There is no measurement dose limit and measurement resolution is better than 0.2% in a low dose rate rotational delivery. The correlation of time with ArcCHECK s 3D measurement data equates to a 4D dosimetry system which offers three key benefits: Detect delivery errors as a function of beam, gantry angle, and control point in real time Optimize treatment plans or number of control points Verify gantry angle with entrance and exit dose ray tracing 4 Y o u r M o s t V a l u a b l e Q A a n d D o s i m e t r y T o o l s

A Cylindrical Design is Most Appropriate for Arc Delivery Applications Coherent ArcCHECK detectors and their angle of incidence remain coherent to the delivery beam regardless of angle. The BEV detector geometry does not change based on angle. When a 2D array is irradiated obliquely, the 2D array degrades to 1D. Even if there is no detector shadowing effect, significant information is lost on a 2D array. 2D Variable 3D Shape Phantoms are ideally shaped like a patient. The cylindrical design of ArcCHECK intentionally emulates patient geometry to better match reality. Geometry Detectors are arranged on a HeliGrid which increases the sampling rate and reduces Beams Eye View (BEV) detector overlap and shadowing, compared to 2D systems. The central 10x10cm of the ArcCHECK contains approximately 221 detectors, the same as the MapCHECK 10x10cm Entrance and exit dose are measured, effectively doubling the detector density in the measurement field Entrance and exit dose can be correlated with time to determine gantry angle Cavity ArcCHECK features a versatile central cavity for capturing dose in multiple locations including isocenter, if desired. With the cavity empty the ArcCHECK weighs only 16kg making it very easy to move and setup A cavity plug is available and may be used to accommodate different detectors and inserts The empty cavity and available inserts tests the TPS inhomogeneity planning MultiPlug See page 7 www.sunnuclear.com 5

With ArcCHECK, See the Entire Picture Below is what a 2D array and ArcCHECK will see for the same plan measurement. ArcCHECK highlights areas that would not normally be seen with a 2D array. Measure and correlate gantry angle, leaf end position, absolute dose and time (4D) to identify the source of the error. Error sources include a TPS, delivery system, imaging system, setup, and MLC. What you see with a 2D array 2D Array Measured With a 2D array, only a fraction of dose information is available, this is inherent with all available 2D arrays. What you see with ArcCHECK 0 o 180 o ArcCHECK Measured ArcCHECK displays BEV dose distribution throughout the entire arc delivery. More data is available to perform a more thorough QA analysis. Beam Delivery ArcCHECK Detector BEV (Beams Eye View) 10 x 10cm 230 Detectors 21 x 21cm 1386 Detectors 6 Y o u r M o s t V a l u a b l e Q A a n d D o s i m e t r y T o o l s

Stringent Interior Measurements ArcCHECK measures entry and exit dose for every angle. Measuring completely around the isocenter in a uniform manner for each angle is a more stringent measurement than a simple composite dose at the isocenter. Errors visible in the isocenter can also be visible in the surrounding dose measurements, but in more detail.* For each beam angle, ArcCHECK measures high dose regions at the entrance and low dose regions at the exit, detecting potential delivery and TPS modeling errors for both high and low dose levels. For those who would like to measure the dose at isocenter or elsewhere within the cavity, Sun Nuclear offers the versatile MultiPlug, and CavityPlug with detector insert. Features Hounsfield conversion testing Precision fitted to ArcCHECK cavity ArcCHECK shown with the optional MultiPlug for measuring dose at up to 25 locations including the isocenter. Inhomogeneity insert options: Muscle Bone Lung Adipose Titanium Dose in cavity center Dose in up to 25 unique locations including the isocenter Film cassette insert Bezel angle indicator for rotation within cavity PMMA (acrylic) construction Included precision milled detector holder Included solid insert for completely solid cavity ArcCHECK shown with the optional CavityPlug for measuring dose at isocenter. Acrylic insert Features Precision fitted to ArcCHECK cavity Dose in cavity center PMMA (acrylic) construction Included precision milled detector holder Included solid insert for completely solid cavity Detector holder *Photons only www.sunnuclear.com 7

SunPoint Diode Detectors: The Right Choice for QA & Dosimetry Smaller detectors provide pinpoint sized sampling of dose data proven to detect errors over an entire field, both in and out of gradient. Attempts to measure the entire field by increasing the detector size creates a blurred measurement in dose gradients. Such measurements are counter-productive to accurate and useful dose sampling. Chambers Ion chamber measurements lack high-resolution, resulting in a blurred measurement EPID/Film EPIDs and film have good density and resolution, however absolute dose, accuracy, uniformity and reproducibility need to be verified Diodes Diodes are capable of accurate, reproducible high-resolution measurements. ArcCHECK uses SunPoint Diode Detectors 2 x 2cm field profile measurements with various detectors Small size = more precision, less averaging 8 Y o u r M o s t V a l u a b l e Q A a n d D o s i m e t r y T o o l s

Hardware that is Easy to Setup and Use Leveling LED s ArcCHECK contains a sophisticated yet easy to use leveling system that ensures setting up for measurement is quick and easy. With built in rotation and tilt inclinometers, the ArcCHECK can relay setup status to the user in real-time. Power/Data Cable Calibration Array ArcCHECK utilizes a patented wide field calibration method (US Patent No. 6,125,335) that typically requires calibration every one to three years. The process takes approximately 30 minutes. In clinical use since 1996, Sun Nuclear s calibration method offers several key benefits: The instrument does not need to be returned to the factory for re-calibration The user may independently verify the accuracy of the calibration The calibration does not require a flat beam Calibration files are not Linac specific The unit does not need to be disassembled Dose ArcCHECK absolute dose calibration is similar to the proven MapCHECK method. The ArcCHECK is positioned with it s axis coincident to SAD, utilizing the coronal and sagittal lasers. A 200 MU beam with a 10x10cm field is delivered to the device. Known dose at the detector location (89.6cm SDD) is entered to arrive at an absolute dose correction, applicable to all ArcCHECK detectors. The process takes approximately one minute to complete prior to arc delivery QA. www.sunnuclear.com 9

Virtual Inclinometer Charted gantry angle as a function of time For any delivery, ArcCHECK will calculate the gantry angle independently using a unique Virtual Inclinometer. This enables correlation of dose and time with angle (4D). The Virtual Inclinometer is accurate to ±0.5, and avoids additional inclinometer cables and mounting to the delivery system. Automatic gantry angle calculation display Control Point Analysis Scrutinize arc plans via ArcCHECK s Control Point Analysis feature. Individual control points and user defined arc sections can be analyzed for a full arc or sub-arc. Measured Planned A unique polar graph with movie playback offers a 360 presentation of pass, low, and high dose summary for the defined control point range and sub-arcs. Control Point Analysis 10 Y o u r M o s t V a l u a b l e Q A a n d D o s i m e t r y T o o l s

SNC Patient Software The ArcCHECK interface is SNC Patient software; a powerful and proven patient QA and analysis tool with over 2000 clinical installations. The same analysis and workflow options from MapCHECK are available in ArcCHECK For larger fields, two ArcCHECK measurements may be concatenated All data files from ArcCHECK are an open format for easy export, including raw data ArcCHECK QA plans are in three dimensions. DICOM RT Dose is imported and a 3D dose grid corresponding to detector locations is extracted for comparison to measured. Angle of measurement indication measured planned compare profiles, histograms, more... 1. Compare. Measure, then click compare to see the results against the planned file 2. TH. Isodose percentage line that defines the dose area to evaluate 3. % Diff. Percent acceptance criterion between Set 1 and Set 2 dose values 4. mm. Distance-to-agreement criterion 5. % Pass. Percentage of detector points that passed within the defined threshold with a pass/fail indication With a single mouse click, SNC Patient Software compares measured dose points to planned dose points. Users can compare normalized data or absolute dose data using distance to agreement (DTA) or Gamma ( ). Three adjustable criteria guarantee maximum flexibility and are easily adjusted. Measured points that do not fit within the acceptance criteria are highlighted red for high dose and blue for low dose. 6. Calc Shift. Determines a misalignment between measured & planned dose maps and automatically corrects if accepted by the user www.sunnuclear.com 11

DVH Analysis (3DVH) 3DVH is a patented (U.S.Patent No. 7,945,022) method that enables the comparison of measured and planned patient DVH s without the complications of a secondary dose algorithm. The planned DVH is extracted from the DICOM patient plan file, then compared to the ArcCHECK measured DVH result. Measured ArcCHECK dose differences perturb the original planned dose, allowing comparison of original planned and as measured planned. DICOM RT structures are presented for DVH analysis, giving a clinically significant analysis of the impact of measured dose differences. 3DVH Independent Publications Per-beam, planar IMRT QA passing rates do not predict clinically relevant patient dose errors Benjamin E. Nelms et al, Med. Phys. 38, 1037 (2011) Moving from gamma passing rates to patient DVH-based QA metrics in pretreatment dose QA Heming Zhen et al, Med. Phys. 38, 5477 (2011) Evaluation of the accuracy of 3DVH software estimates of dose to virtual ion chamber and film in composite IMRT QA Arthur J. Olch, Med. Phys. 39 (1), 81-6 (2012) VMAT QA: Measurement-guided 4D dose reconstruction on a patient Benjamin E. Nelms et al, Med. Phys. 39, 4228 (2012) 12 Y o u r M o s t V a l u a b l e Q A a n d D o s i m e t r y T o o l s

Machine QA Save time and improve accuracy. Use ArcCHECK for a wide variety of machine QA tests in dynamic and rotational mode. Dynamic Gantry Rotation QA* Dynamic Gantry Angle QA* Dynamic Gantry Speed QA Dynamic Symmetry and Flatness* MLC QA Treatment Reproducibility QA *Also available with static angles www.sunnuclear.com 13

FAQ Does ArcCHECK measure the isocenter dose? ArcCHECK measures entry dose before the isocenter, and exit dose after the isocenter at two effective depths for every angle. Measuring completely around the isocenter in a uniform manner for each angle is a more stringent measurement than a simple composite dose at the isocenter. Errors visible in the isocenter will also be visible in the surrounding dose measurements, but in more detail. For those who would like to measure the dose at isocenter or target, Sun Nuclear offers cavity plug options with detector inserts. Does ArcCHECK perform comparisons in 3D? Yes. Can the ArcCHECK measure in absolute dose? SunPoint Diode Detector based instruments measure the absolute dose accurately with the dose calibration of the reference detector to the standard accelerator output, exactly as an ion chamber device would do. What is the purpose of the ArcCHECK cavity? 1. The cavity may always be filled with the ArcCHECK Cavity Plug, however if left empty the cavity tests the ability of the TPS to calculate plans with air cavities and inhomegenities. This approach offers another way of doing QA on the TPS/ delivery system. All modern treatment planning systems should be capable of creating a plan on the ArcCHECK without the cavity plug option inserted. Without the cavity plug inserted, there are still several cm s of scatter material above and below the detectors. What is the angular dependence of ArcCHECK? ArcCHECK offers an angular compensation feature which results in negligible dependence (<±1.0%). Even with this feature disabled, angular dependence varies from 0 to a maximum of 8% seen only when the beam is incident on the diode at 90 o. Axial angular dependence rapidly diminishes as the beam approaches central axis. Due to the detector geometry, coronal angular dependence is negligible. Within a 10x10 field the effect of the angular dependence is completely negligible. Every multi-channel detector array has some form of angular dependence. An advantage of ArcCHECK over 2D arrays is angular dependence is not variable by gantry angle, but variable by detector location. For any given angle, the majority of the array has negligible angular dependence. Can ArcCHECK be used for IMRT? Yes. Although the ArcCHECK was designed specifically for rotational delivery QA, it is an excellent tool for both composite and field by field IMRT QA. The key advantage of ArcCHECK for IMRT QA is that the radiation can be delivered at the prescription gantry angle without the need to position the array in a gantry attachment to keep the detectors perpendicular to the beam. What is the largest field ArcCHECK can measure? The length and diameter of the ArcCHECK array is 21cm. Although with beam divergence, a 22cm diameter is effective. 2. Easy to transport/lightweight. 3. Flexibility of inserts: for dose measurements for inhomogeneity measurments 14 Y o u r M o s t V a l u a b l e Q A a n d D o s i m e t r y T o o l s

Helical Grid (HeliGrid) Geometry 1386 SunPoint Diode Detectors 1.0cm Detector Spacing 21.0cm Array Length Central Cavity 21.0cm Array Diameter Specifications Detector type: SunPoint Diode Detectors Detector quantity: 1386 Detector spacing (cm): 1.0 Array diameter (cm): 21.0 Array length (cm): 21.0 Cavity diameter (cm): 15.0 Inherent buildup (g/cm 2 ): 3.2 Inherent backscatter (g/cm 2 ): 3.2 Detector physical depth (cm): 2.9 Array geometry: Helical Grid (HeliGrid) 1cm offset Phantom Material: PMMA (Acrylic) Active detector area (mm 2 ): 0.64 2.9cm Physical Detector Depth Detector volume (cm 3 ): 0.000019 Detector stability: 0.5%/kGy at 6MV Dose rate dependence: ± 1%, 75-250cm SSD Update frequency (ms): 50 Radiation measured: Photons, Co-60 to 25 MV Number of connection cables: Single power/data cable Dimensions (cm 2 ) / Weight (kg): 27.0 x 43.0 / 16.0 Operating system: Windows XP, Vista, 7 (32 or 64 bit) 4GB RAM, 1 available USB 2.0 port, Dual-core Computer Requirements: processor (2.4GHz or higher), 5GB hard disk space, 32MB VRAM video card, 32-bit color depth, OpenGL hardware accelerated Novel dosimetric phantom for quality assurance of volumetric modulated arc therapy Daniel Létourneau, Julia Publicover, Jakub Kozelka, Douglas J. Moseley and David A. Jaffray, Med. Phys. 36 (5), 1813-1821 (2009) Modeling the instantaneous dose rate dependence of radiation diode detectors J. Shi, W.E. Simon, T.C. Zhu, Med. Phys. 30 (9), 2509-2519 (2003) Optimizing the accuracy of a helical diode array dosimeter: A comprehensive calibration methodology coupled with a novel virtual inclinometer Jakub Kozelka et al., Med. Phys. 38 (9), 5021 5031 (2011) "The ArcCHECK diode array for dosimetric verifcation of HybridArc" A L Petoukhova et al., Phys. Med. Biol. 56, 5411 5428 (2011) Available outside of US. US pending 21CFR892.5050 reclassification. All data used is best available at time of publication. Data is subject to change without notice. All Content 2013, Sun Nuclear Corporation. All Rights Reserved. Elekta, VMAT and its logo are all trademarks of Elekta AB. TomoTherapy and its logo are all registered trademarks or service marks of TomoTherapy Inc. RapidArc and its logo are all trademarks of Varian Medical Systems, Inc. www.sunnuclear.com 15

1220W050313 Corporate Headquarters 3275 Suntree Blvd. Melbourne, Florida 32940 tel: + 1 321 259 6862 www.sunnuclear.com