HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

Similar documents
HYDROFIRM (T) Cables. for use in Ground Water and Drinking Water

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

kv: medium voltage reeling cable with fibreoptics

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813

Medium Voltage Power Cables

SUBMERSIBLE PUMP CABLES

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

H07RN-F BS EN Flexible Rubber Cable

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

FLEXIBLE MULTI CORE CABLES

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

Armoured Power and Control Cables Fire Resistant

Electric cables. Cranes

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Caledonian. VG Series. Caledonian Navy Cables.

DB EN valid from: Application SERVO LK SMS FX8PLUS SIGNAL

Selection table for flat & ribbon cables

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

ABOUT US ABOUT US 1 CRANE CABLES

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

Welding Cables Rubber Insulated

Kerman & Kavian Cable Industries ( KCI )

INSTRUCTIONS FOR THE SAFE APPLICATION OF CABLES

Power Cables and their Application

Armoured Power and Control Cables to BS7917

Marine Cables General Catalogue

FieldLink MC at 20 x outer diameter Torsion

Measuring current transformers of the W, W series

NETWORK CONNECTIVITY SYSTEMS

CUSTOM DESIGN COAXIAL CABLES BY SICAB

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

Innovative Eldra Solar Cabling System SOLINQ total system for solar cabling Sustainability

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Armoured Power and Control Cables to BS6883

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

a Nexans company Catalogue 2009

MarineLine YOZp 0,6/1 kv

Armoured Instrumentation Cables to BS6883

a Nexans company Catalogue 2012

UNIRAIL D RS485 and BUS cables

PRODUCT INFORMATION UNITRONIC BUS PB

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Cable Solutions for Servo and Variable Frequency Drives (VFD)

High Temperature Flexible Control Cable

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

CIR (Crush & Impact Resistant) VFD Power Cable

a Nexans company Catalogue 2012

Caledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017

TRAXLINE CABLES FOR MOTION

IEC Standard Caledonian Offshore & Marine Cables

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

Railway products. Edition 2014

TIGER BRAND MINING CABLES

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

Measuring current transformers of the W AB(P) series

REPORT OF PERFORMANCE TIC

The Quality Connection. Cable and Systems for Rolling Stock Business Unit Rolling Stock

Optical Ground Wires (OPGW)

INTERNATIONAL STANDARD

CERTIFICATE OF CONFORMANCE

MINI-PS AC/24DC/1.3

Nexans Network Solutions Div. Euromold

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

All the standards referred to the most current issue, including all amendment supplements. as of the date of the bid.

Contents. Introduction 3 Cable Components 4 Cable Handling 8 Health, Safety and Environment 9 Quick Reference Guide 10 Underground Mining - Coal 12

Installation Recommendations

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

MULTIMEDIA CABLE H6091ZHB

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

non-sheathed cables for fixed Wiring integrity is doing the right thing, even if nobody is Watching JiM stovall

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.

ECOFLEX 10 Characteristics Diameter 10,2 mm. ECOFLEX 15 Characteristics Diameter 14,6 mm. AIRCOM PLUS Characteristics Diameter 10,3 mm

CABLES AND WIRES

MEDIUM VOLTAGE

Safety Warning. Installation

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

METRATESTER 5+ Tester for DIN VDE /6.15

Fireproof Cables (Fire Resistant LSOH Sheathed Cables) КИФнг(A)-HF for RS485

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

BENDING RADIUS. DIAMETER TOLERANCE Cable outer diameter, mm. Tolerance CORE IDENTIFICATION TECHNICAL INFORMATION 8/2010

Measuring current transformers of the W B series

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

GEXOL WORLD CLASS OIL & GAS CABLES

This Certificate consists of 75 pages in total.

UPA 150C. 50 Hz. Applications. Submersible Borehole Pumps for Well Diameters of 150 mm (6 inches) Operating Data. Design. Designation (Example)

Tri-Rated Flexible PVC Equipment Wire

Conductix-Wampfler Cables for Festoon Systems, Energy Guiding Chains & Others

THE WORLD OF LAPP. Cables for power chains

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

Transcription:

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY Exclusive Authorised UK Distributor

Technical Data Trademark Type designation Specification Application HYDROFIRM(T) EMV FC S1BC4B F Design and tests according to Pirelli specification For making connections to electrical equipment used in water and subjected to medium mechanical stress. Especially for frequency converter controlled AC drives and if considerable demands in respect of electromagnetic compatibility (EMC) according to the EMC directive imposes. For an effective shielding both ends of cable must have a good shield contact to ground. The cables can also be used in drinking water, industrial water, cooling water, surface water, rainwater, ground water and sea water (salt water). These cables fulfil the requirements of health according to the German KTW Recoendation, the requirements of the growth of microorganisms according to the German DVGW Arbeitsblatt W270 and the Attestation de Confirmitè Sanitaire (ACS) according to French law. HYDROFIRM is further approved according WRAS (UK). The relevant certificates are available. If the water concerned is aggressive or composed of special substances, the cables resistance properties should be examined. These cables can be used indoors, outdoors, in industrial and agricultural plant, but not in explosion hazard areas. In other respects, DIN VDE 0298 300 / HD 516 applies. Electrical Rated voltage Maximum permissible operation voltage of plant and power system AC test voltage Uo/U = 0.6/1 kv Single phase and three phase AC operation Line Earth/ Line Line 0.7/1.2 kv DC operation Line Earth/ Line Line 0.9/1.8 kv 3 kv (test duration 15 min.) Current carrying capacity The s are valid for a cable in permanent operation with DC or AC with 50 up to 60 Hz in air at 30 C. In other respects, DIN VDE 0298 4 applies Thermal Maximum permissible operating temperature at conductor Maximum permissible shortcircuit temperature at conductor Minimum permissible temperatures Maximum permissible water temperature 90 C 250 C (max. 5s) when in motion 25 C when stationary 40 C 60 C (At higher water temperatures, a shortened cable service life is to be expected.) For applications in waters up to 80 C, please ask for our special cable HYDROFIRM TGH. Mechanical Tensile strength Minimum bending radii max. 15 N/², see selection table See selection table

Technical Data Special Water resistance Test according to DIN VDE 0282 16 (HD 22.16) Requirements of health No growth of microorganisms Acceptance in France Approval for UK: Test according to the German KTW Recoendation Test according to the German DVGW Arbeitsblatt W270 Test according to the Attestation de Conformité Sanitaire ACS Approved according Water Regulations Advisory Scheme (WRAS) file Nr. 0710527

Design features Conductor Copper, plain, finely stranded, Class 5 according to DIN VDE 0295 / HD 383 / IEC 60228 Insulation Ozone, water and weather resistant insulation compound, base EPR (Ethylene Propylene Rubber) Core identification Colour of cores according to DIN VDE 0293 308:2003 Sheath Shield Marking 2 layer sheath system: Inner layer: EPR special compound; according to KTW Recoendation; colour: blue Outer layer: EPR special compound; according to KTW, DVGW (W270), WRAS and ACS instructions; colour: blue Braiding of tinned copper wires between inner and outer sheath Maximum transfer impedance of 250 Ohm/km at 30 MHz HYDROFIRM(T) EMV FC S1BC4B F 3X10/10 KON 0,6/1 kv KTW DVGW W270 ACS WRAS

Selection and ordering data Number of cores and nominal cross sectional area ² Order No. Conductor guidance Diameter over shield guidance Overall of cable Min. Overall of cable Max. Minimum bending radii (fixed installation) Minimum bending radii (free movement and entry) Approx. net weight for 1000 m kg Tension force Max. N Currentcarrying capacity, touching surfaces, at 30 C, 3 cores loaded A Shortcircuit current 1 s ka HYDROFIRM(T) EMV FC S1BC4B F 3X1,5/1,5KON 5DH8 742 1,6 8,7 9,5 11,1 33 44 171 67 23 0,21 3X2,5/2,5KON 5DH8 743 2,0 9,7 10,5 12,1 48 61 225 112 30 0,36 3X4/4KON 5DH8 744 2,4 10,7 11,8 13,4 54 67 304 180 41 0,57 3X6/6KON 5DH8 745 2,9 12,2 13,6 15,2 61 76 382 270 53 0,86 3X10/10KON 5DH8 746 3,9 16,6 17,8 19,8 79 99 680 450 74 1,43 3X16/16KON 5DH8 747 5,0 19,4 20,9 22,9 92 115 1016 720 99 2,29 3X25+3G16/3 5DH8 748 6,3 24,5 25,3 28,3 113 142 1448 1125 131 3,58 3X35+3G16/3 5DH8 749 7,5 26,7 28,3 31,3 125 157 1845 1575 162 5,01 3X50+3G25/3 5DH8 750 8,9 31,0 33,2 36,2 145 181 2582 2250 202 7,15 3X70+3G35/3 5DH8 751 10,7 36,0 38,7 41,7 167 209 3560 3150 250 10,01 3X95+3G50/3 5DH8 752 12,3 41,5 43,7 47,7 191 239 4560 4275 301 13,59 3X120+3G70/3 5DH8 753 14,3 45,6 48,8 51,8 207 259 5685 5400 352 17,16 Technical data, dimension and weights are subject to change. Version: 1.0 Date: 2008 02 19 Anixter is a leading global supplier of counications products used to connect voice, video, data and security systems. Anixter is also a leading provider of electrical and electronic wire and cable, fasteners and other small components to build, repair, and maintain a variety of systems and equipment. We bundle our products with our innovative Supply Chain Services to cut costs out of our customers business processes, and ensure they get the right product, the first time. We look forward to being of service to you. For further information, please contact: Lee Bagnall Telephone Number: 0121 322 7149 Fax: 08717 146692 E-mail: lee.bagnall@anixter.com Anixter Brimington Road North Chesterfield Derbyshire S41 9BE www.anixter.co.uk