APPENDIX T: Off Site Ambient Tests

Similar documents
Acoustics `17 Boston

Wind farm infrasound Are we measuring what is actually there or something else?

Complex Sounds. Reading: Yost Ch. 4

Structure of Speech. Physical acoustics Time-domain representation Frequency domain representation Sound shaping

SAMPLING THEORY. Representing continuous signals with discrete numbers

Music 171: Amplitude Modulation

Signals and Systems Lecture 9 Communication Systems Frequency-Division Multiplexing and Frequency Modulation (FM)

ME scope Application Note 01 The FFT, Leakage, and Windowing

The quality of the transmission signal The characteristics of the transmission medium. Some type of transmission medium is required for transmission:

Outline. Communications Engineering 1

Department of Electronic Engineering NED University of Engineering & Technology. LABORATORY WORKBOOK For the Course SIGNALS & SYSTEMS (TC-202)

Signals, systems, acoustics and the ear. Week 3. Frequency characterisations of systems & signals

Impulse Response as a Measurement of the Quality of Chirp Radar Pulses

Sound is the human ear s perceived effect of pressure changes in the ambient air. Sound can be modeled as a function of time.

Acoustics, signals & systems for audiology. Week 3. Frequency characterisations of systems & signals

Speech, music, images, and video are examples of analog signals. Each of these signals is characterized by its bandwidth, dynamic range, and the

Acoustics, signals & systems for audiology. Week 4. Signals through Systems

CHAPTER 6 INTRODUCTION TO SYSTEM IDENTIFICATION

3D Intermodulation Distortion Measurement AN 8

Linear Frequency Modulation (FM) Chirp Signal. Chirp Signal cont. CMPT 468: Lecture 7 Frequency Modulation (FM) Synthesis

Signal Characteristics

Signals A Preliminary Discussion EE442 Analog & Digital Communication Systems Lecture 2

AMPLITUDE MODULATION CASE STUDY AT THE LEONARDS HILL WIND FARM, VICTORIA, AUSTRALIA

Introduction to Telecommunications and Computer Engineering Unit 3: Communications Systems & Signals

UNIT-3. Electronic Measurements & Instrumentation

Theory of Telecommunications Networks

2.1 BASIC CONCEPTS Basic Operations on Signals Time Shifting. Figure 2.2 Time shifting of a signal. Time Reversal.

IEEE 802.3aq Task Force Dynamic Channel Model Ad Hoc Task 2 - Time variation & modal noise 10/13/2004 con-call

Introduction. In the frequency domain, complex signals are separated into their frequency components, and the level at each frequency is displayed

Response spectrum Time history Power Spectral Density, PSD

(i) Sine sweep (ii) Sine beat (iii) Time history (iv) Continuous sine

Musical Acoustics, C. Bertulani. Musical Acoustics. Lecture 14 Timbre / Tone quality II

3D Distortion Measurement (DIS)

Linear Time-Invariant Systems

Transfer Function (TRF)

Communication Engineering Prof. Surendra Prasad Department of Electrical Engineering Indian Institute of Technology, Delhi

Local Oscillator Phase Noise and its effect on Receiver Performance C. John Grebenkemper

Musical Acoustics, C. Bertulani. Musical Acoustics. Lecture 13 Timbre / Tone quality I

3.2 Measuring Frequency Response Of Low-Pass Filter :

Chapter 3. Amplitude Modulation Fundamentals

ALTERNATING CURRENT (AC)

Spectrum. The basic idea of measurement. Instrumentation for spectral measurements Ján Šaliga 2017

Copyright 2009 Pearson Education, Inc.

Fundamentals of Music Technology

An Investigation into the Effects of Sampling on the Loop Response and Phase Noise in Phase Locked Loops

Laboratory Assignment 4. Fourier Sound Synthesis

Lecture 6. Angle Modulation and Demodulation

Chapter 2. Fourier Series & Fourier Transform. Updated:2/11/15

Compensating for speed variation by order tracking with and without a tacho signal

Lecture 7 Frequency Modulation

Introduction. Chapter Time-Varying Signals

Signals & Systems for Speech & Hearing. Week 6. Practical spectral analysis. Bandpass filters & filterbanks. Try this out on an old friend

Chapter 2. Meeting 2, Measures and Visualizations of Sounds and Signals

Chapter 2. Signals and Spectra

ECE 201: Introduction to Signal Analysis

Signal Detection with EM1 Receivers

UNIT I AMPLITUDE MODULATION

Advanced Audiovisual Processing Expected Background


Gear Transmission Error Measurements based on the Phase Demodulation

A new methodology for investigating ILFN complaints

Spectrum. Additive Synthesis. Additive Synthesis Caveat. Music 270a: Modulation

14 fasttest. Multitone Audio Analyzer. Multitone and Synchronous FFT Concepts

Laboratory Assignment 5 Amplitude Modulation

Continuous time and Discrete time Signals and Systems

ADC Clock Jitter Model, Part 1 Deterministic Jitter

Outline. EECS 3213 Fall Sebastian Magierowski York University. Review Passband Modulation. Constellations ASK, FSK, PSK.

Rotating Machinery Fault Diagnosis Techniques Envelope and Cepstrum Analyses

Solution to Chapter 4 Problems

Music 270a: Modulation

Measurement of Amplitude Modulation AN 6

Pulse Code Modulation (PCM)

Dynamic Generation of DC Displacement AN 13

Amplitude Modulation Effects in Cardiac Signals

Standard Octaves and Sound Pressure. The superposition of several independent sound sources produces multifrequency noise: i=1

Sound pressure level calculation methodology investigation of corona noise in AC substations

Michael F. Toner, et. al.. "Distortion Measurement." Copyright 2000 CRC Press LLC. <

3.1 Introduction to Modulation

Spectrum Analysis: The FFT Display

FFT 1 /n octave analysis wavelet

Kent Bertilsson Muhammad Amir Yousaf

ENGR 210 Lab 12: Sampling and Aliasing

Fourier Transform Analysis of Signals and Systems

Module 3 : Sampling and Reconstruction Problem Set 3

9LEUDWLRQ 0HDVXUHPHQW DQG $QDO\VLV

Data and Computer Communications Chapter 3 Data Transmission

4.1 REPRESENTATION OF FM AND PM SIGNALS An angle-modulated signal generally can be written as

Lecture 2: SIGNALS. 1 st semester By: Elham Sunbu

two computers. 2- Providing a channel between them for transmitting and receiving the signals through it.

HRV spectrum bands & single peak Coherence

Discrete Fourier Transform

ELEC3242 Communications Engineering Laboratory Amplitude Modulation (AM)

Frequency Domain Analysis

Definition of Sound. Sound. Vibration. Period - Frequency. Waveform. Parameters. SPA Lundeen

COMP 546, Winter 2017 lecture 20 - sound 2

CMPT 368: Lecture 4 Amplitude Modulation (AM) Synthesis

Experiment 1 Design of Conventional Amplitude Modulator

Measurement Procedure & Test Equipment Used

EC 554 Data Communications

ECMA-108. Measurement of Highfrequency. emitted by Information Technology and Telecommunications Equipment. 4 th Edition / December 2008

Transcription:

Appendix T1 APPENDIX T: Off Site Ambient Tests End of Blowholes road Substation access Surf Club East end of Blowholes Road

Appendix T2 West end of Blowholes Road

Appendix T3 West end of Blowholes Rd west end of Blowholes Rd, to sea (Real) west end of Blowholes Rd, to sea (Real) 1 8 5 1 15 2 25 3 35 45

Appendix T4 west end of Blowholes Rd, to turbine (Real) west end of Blowholes Rd, to turbine (Real) 1 8 5 1 15 2 25 3 35 45 Blowholes road and substation road entrance

Appendix T5 Blowholes Rd and road to substation, above ground (Real) Blowholes Rd and road to substation, above ground (Real) 1 8 5 1 15 2 25 3 35 45 Blowholes Rd and road to substation, ground plane (Real) Blowholes Rd and road to substation, ground plane (Real) 9 8 7 5 1 15 2 25 3 35 45

Appendix T6 east end of Blowholes Rd, above ground (Real) east end of Blowholes Rd, above ground (Real) 1 8 5 1 15 2 25 3 35 45

Appendix T7 east end of Blowholes Rd, ground plane (Real) east end of Blowholes Rd, ground plane (Real) 9 8 7 3 5 1 15 2 25 3 35 45

Appendix T8 Surf Club (Real) [db(a)/2u Pa] 65 62.5 57.5 Surf Club (Real) Surf Club (Real) 7 1 2 3 [s] (Relative Time) 2 8 1 12 1 1 18 2

Appendix T9 Surf Club (Real) Surf Club (Real) 3 4 8 12 16 2 24

Appendix T1 Cape Discovery car park Cape Bridgewater Lakes car park Shelly Beach carpark Turbine CBW 1

Appendix T11 Cape Discovery Cape Discovery Car Park (Real) Cape Discovery Car Park (Real) 1 9 8 7 2 8 1 12 1 1 18 2

Appendix T12 Cape Discovery Car Park (Real) Cape Discovery Car Park (Real) 9 8 7 4 8 12 16 2 24 Cape Discovery Car Park (Real) [db(a)/2u Pa] 65 55 1 2 3 [s] (Relative Time)

Appendix T13 Bridgewater Lakes Car Park (Real) Bridgewater Lakes Car Park (Real) 9 8 7 3 2 8 1 12 1 1 18 2 Bridgewater Lakes Car Park (Real) Bridgewater Lakes Car Park (Real) 8 7 4 8 12 16 2 24

Appendix T14 Bridgewater Lakes Car Park (Real) [db(a)/2u Pa] 57.5 55 52.5 47.5 1 2 3 [s] (Relative Time)

Appendix T15 Shelly Beach Shelly Beach (Real) Shelly Beach (Real) 1 8 2 8 1 12 1 1 18 2

Appendix T16 Shelly Beach (Real) Shelly Beach (Real) 9 8 7 4 8 12 16 2 24 Shelly Beach (Real) [db(a)/2u Pa] 65 62.5 57.5 1 2 3 [s] (Relative Time)

Appendix T17 Gullen House PW4 (Real) Gullen House PW4 (Real) 8 7 3 2 2 8 1 12 1 1 18 2 Gullen House PW4 (Real) Gullen House PW4 (Real) 8 7 3 2 4 8 12 16 2 24

Appendix T18 Gullen House PW34 (Real) Gullen House PW34 (Real) 8 7 3 2 1 2 8 1 12 1 1 18 2 Gullen House PW34 (Real) Gullen House PW34 (Real) 8 7 3 2 4 8 12 16 2 24

Appendix T19 Capital House G16 (Real) Capital House G16 (Real) 11 1 9 8 7 2 8 1 12 1 1 18 2 Capital House G16 (Real) Capital House G16 (Real) 9 8 7 4 8 12 16 2 24

Appendix T2 Collector House V (Real) Collector House V (Real) 1 9 8 7 3 2 1 2 8 1 12 1 1 18 2 Collector House V (Real) Collector House V (Real) 9 8 7 3 2 4 8 12 16 2 24

Appendix T21 Bocco Road - Monastery Outside (Real) Bocco Road - Monastery Outside (Real) 8 7 3 2 2 8 1 12 1 1 18 2 Bocco Road - Monastery Outside (Real) Bocco Road - Monastery Outside (Real) 8 7 3 4 8 12 16 2 24

Appendix T22 Bocco Road - Monastery Guest House Outside (Real) Bocco Road - Monastery Guest House Outside (Real) 45 35 3 25 2 15 1 5 2 8 1 12 1 1 18 2 Bocco Road - Monastery Guest House Outside (Real) Bocco Road - Monastery Guest House Outside (Real) 36 32 28 24 2 16 12 4 8 12 16 2 24

Appendix T23 Hallett Hill Wind Farm - External Residents 52 (Real) Hallett Hill Wind Farm - External Residents 52 (Real) 9 8 7 3 2 2 8 1 12 1 1 18 2 Hallett Hill Wind Farm - External Residents 52 (Real) Hallett Hill Wind Farm - External Residents 52 (Real) 8 7 4 8 12 16 2 24

Appendix T24 Waterloo West outside (Real) Waterloo West outside (Real) 3 2 1 2 8 1 12 1 1 18 2 Waterloo West outside (Real) Waterloo West outside (Real) 3 2 4 8 12 16 2 24

Appendix T25 Waterloo West inside (Real) Waterloo West inside (Real) 35 3 25 2 15 1 5-5 2 8 1 12 1 1 18 2 Waterloo West inside (Real) Waterloo West inside (Real) 35 3 25 2 15 1 5 4 8 12 16 2 24

Appendix T26 Lobbs Road Waubra Bedroom (Real) Lobbs Road Waubra Bedroom (Real) 8 7 3 2 1-1 2 8 1 12 1 1 18 2 Lobbs Road Waubra Bedroom (Real) Lobbs Road Waubra Bedroom (Real) 7 3 2 1 4 8 12 16 2 24

Appendix T27 Lobbs Road Waubra Outside (Real) Lobbs Road Waubra Outside (Real) 9 8 7 3 2 2 8 1 12 1 1 18 2 Lobbs Road Waubra Outside (Real) Lobbs Road Waubra Outside (Real) 9 8 7 3 4 8 12 16 2 24

Appendix T28 Coal Mine in Hunter Valley (Real) Coal Mine in Hunter Valley (Real) 7 3 2 2 8 1 12 1 1 18 2 Coal Mine in Hunter Valley (Real) Coal Mine in Hunter Valley (Real) 8 7 3 2 4 8 12 16 2 24

Appendix U1 APPENDIX U: Resident s Hot Spots House 87 Ambient Vibration on Living Room floor adjacent Bedroom Wall (vertical)

Appendix U2 Vibration on Living Room floor adjacent Bedroom Wall (vertical) walking on floor Eastern verandah on footing - vertical

Appendix U3

Appendix U4 House 88 Bedroom Noise 4145 (Real) 7 3 2 4 8 12 16 2 24 Floor vibration 836 x (Real) 836 y (Real) [m/s²] u 2u 1u u 2u 1u 5u 2u 1u n 2n 1n 4 8 12 16 2 24 Fridge ON

Appendix U5 Fridge on, bedroom (Real) 45 35 3 25 2 15 1 5-5 -1-15 2 8 1 12 1 1 18 2 Fridge on, Vertical Axis (Real) [m/s²] 5m 3m 2m 1.5m 1m 7u u 3u 2u 1u 1u 7u 2 8 1 12 1 1 18 2 Fridge OFF

Appendix U6 Fridge off, bedroom (Real) 45 35 3 25 2 15 1 5-5 -1-15 2 8 1 12 1 1 18 2

Appendix U7 Outside East/West Accelerometer 1 Minute Sample Dominate impulse resonance frequency calculated 83Hz

Appendix U8 1 Minute sample at end of previous 1 minute sample Frequency Analysis of above 1 minute sample

Appendix U9 Outside North/South Accelerometer 1 Minute Sample 1 Minute sample at end of previous 1 minute sample

Appendix U1 Frequency Analysis of above 1 minute sample [m/s²] 1u 1u 7u u North-South Axis (Real) North-South Axis (Real) 3u 2u 15u 1u 7u 5u 3u 2u 2 8 1 12 1 1 18 2 1/3octave horizontal 1 minute Leq versus AS267-2 base curve

Appendix U11 Outside Vertical Accelerometer Dominate impulse resonance frequency calculated 47Hz

Appendix U12! minute sample from end of ten minute sample Frequency Analysis of above 1 minute Leq sample

Appendix U13 1/3 octave Leq versus base curve of AS267.2 House 89 Ground vibration spectra (Leq 1 minute) external to dwelling (north side)

Appendix V1 APPENDIX V: FFT Synthesis In the initial stages the subject study utilised constant percentage bandwidth analysis to examine the acoustic signatures obtained at residential properties. A refinement of the analysis to provide an increased level of frequency resolution was undertaken by the use of narrowband analysis. Narrowband analysis is normally presented in the linear frequency domain to identify discrete frequencies associated with operation of the turbines at Cape Bridgewater. Originally acoustical analysers for narrow band analysis used a limited bandwidth tracking filter that swept across the analogue signal range of concern. Since the mid 198 s with the advent of digital techniques for both constant percentage bandwidth and narrow bandwidth assessments there are different mathematical techniques used to derive the resultant data. In the context of this study the narrow band analysis has used mathematical tools incorporated in the analysers that are based upon a Fast Fourier Transform ( FFT ). In considering the relevance of the FFT results with respect to the operation of the turbines this Appendix presents a basic analysis concept (on a theoretical basis) of the FFT as applied to different time signals on a theoretical basis using an analysis package similar to the National Instruments Labview program that is embedded in the B & K Pulse and Reflex programs. Basic Frequency Analysis of Periodic Signals The common tool used for frequency analysis is the Fast Fourier Transform (FFT). A technical explanation of the FFT when applied to a time signal is that it deconstructs the signal into its equivalent frequency domain components. A generalised concept of the application of the FFT in acoustic analysis is to extract periodic patterns that occur in time domain that are then shown as discrete frequencies (in the frequency domain). Figure V1 show the time signal of a pure sinusoid at.8hz with Figure V2 showing the corresponding FFT.

db re (Max Signal Level) db re (Max signal level) The Results of an Acoustic Testing Program Cape Bridgewater Wind Farm Appendix V2 1.5 Pure sinusoidal tone - Frequency =.8Hz FFT of Pure Sinusoidal Tone - Frequency =.8Hz 1.5 - -.5-1 -1-1.5 1 2 3 4 5 6 7 8 9 1 Time (s) Figure V1: Pure tone sinusoid at a frequency of.8hz -1 5 1 15 2 25 3 35 45 Frequency (Hz) Figure V2: FFT of Figure V1 The underlying theory of the FFT (re a Fourier series) states that any periodic function can be reconstructed with sinusoidal, pure tone signals. A non-sinusoidal periodic signal at a particular frequency can be reconstructed by adding together pure tones at integer multiples (harmonics) of the signal frequency. The nature of the dynamic wind forces across the turbine blades can be described as generating pressure pluses. Figure V3 shows a square wave at.8hz with its FFT shown in Figure V4. 1 Square Wave: Freq =.8, Duty = % FFT of Square Wave; Freq =.8, Duty = %.8-1.6-2.4.2-3 - -.2 - -.4 - -.6 -.8-1 1 2 3 4 5 6 7 8 9 1 Time (s) Figure V3: Square wave at.8 Hz -7-8 5 1 15 2 25 3 35 45 Frequency (Hz) Figure V4: FFT of square wave in Figure V3

db re (Max Input Level) The Results of an Acoustic Testing Program Cape Bridgewater Wind Farm Appendix V3 The FFT shows a component at the fundamental frequency (of the square wave.8hz) and components at integer multiples of the fundamental. In this case the odd harmonics (identifying 1.6Hz as the second harmonic) are lower in magnitude, since the square wave has a duty cycle of % (i.e. % on, % off). NB: In dealing with the description of harmonics which is described as integral multiples of the fundamental frequency there are two definitions that may be applied. Australian Standard AS1633 Acoustic Glossary of terms and related signals notes in the definition of harmonics: Of a periodic quality: a sinusoidal component of the periodic quality having a frequency which is an integral multiple of the fundamental frequency. NOTE: In science, the nth harmonic implies a frequency equal to n times the fundamental frequency; in music the nth harmonic usually implies a frequency equal to (n+1) times the fundamental. The scientific definition of harmonic has been used in the study. Figure V5 shows a pulse wave with a 2% duty cycle at.8hz, being a smaller duty cycle than the previous example. The corresponding FFT shown as Figure V6 reveals a similar result to Figure V4, however the relationships between the harmonic peaks is different. 1 Square Wave; Freq =.8, Duty = % X:.8 Y: -.5757 Square Wave FFT; Freq =.8, Duty = 2%.8.6-1.4-2.2 -.2 -.4 -.6 -.8-1 1 2 3 4 5 6 7 8 9 1 Time (s) -3 - - - -7-8 5 1 15 2 25 3 35 45 Frequency (Hz) Figure V5: Pulse wave at.8hz (2% Duty cycle) Figure V6: FFT of Figure V5

Appendix V4 Standard FFT plots for acoustic assessments, as shown here, are typically concerned with representing the magnitude of the frequency components, corresponding only to the amplitude of the sinusoid. The result of an FFT is in fact a complex value with real and imaginary components for each frequency line. This can be written in the form: Ae iφ Where: A = Amplitude of the sinusoid φ = Phase of the sinusoid The FFT plots present the amplitude of the signal at the various frequencies determined as a function of the analysis of the time signal. If one were to reconstruct the original signal using the FFT result as described by the Fourier series the phase φ should be included, where phase is with respect to the effective zero time point of FFT analysis. Changing the duty cycle causes changes in the harmonic components in terms of their phase and amplitude. This is demonstrated when comparing Figure V4 and Figure V6 where it is noted only the magnitude is shown. By taking the fundamental and first 3 harmonics of the FFT in Figure V6 as sinusoidal waves having the application shown Figure V7, an approximation of the Figure V5 pulse wave can be made. Figure V7 shows the relative relationships between the first four harmonic tones given from the FFT (Figure V6) of the 2% duty cycle pulse wave shown in Figure V5.

Appendix V5.5 First Harmonic (.8Hz).5 2nd Harmonic (1.6Hz) -.5 2 4 6 8 1 Time (s) -.5 2 4 6 8 1 Time (s).5 3rd Harmonic (2.4Hz).5 4th Harmonic (3.2Hz) -.5 2 4 6 8 1 Time (s) -.5 2 4 6 8 1 Time (s) Figure V7: Harmonic components from Figure V6 FFT (Fundamental, 2 nd, 3 rd and 4 th harmonics) The linear addition of the fundamental and first three harmonics of the 2% duty cycle pulse wave is shown in Figure V8..8 4th Harmoic Approx. of Pulse Wave.6.4.2 -.2 -.4 -.6 -.8 1 2 3 4 5 6 7 8 9 1 Time (s) Figure V8: 4 th harmonic approximation to 2% duty cycle pulse wave

db The Results of an Acoustic Testing Program Cape Bridgewater Wind Farm Appendix V6 By adding higher order harmonics the approximation of the pulse wave will become more accurate. The FFT shown in Figure V9 (of the signal in Figure V8) demonstrates that the Figure V8 signal can be deconstructed into the sinusoidal terms used to create it. FFT of 4th Harmoic Pulse Wave Approximation -2 - - -8-1 -12 5 1 15 2 25 3 35 45 Frequency (Hz) Figure V9: FFT of 4 th harmonic approximation to 2% duty cycle pulse wave The material above shows that, when using the FFT as a tool for signal analysis, that the analysis method (by design) breaks a signal into discrete frequency components. However the result shown in Figure V9 identifies that the time signal in Figure V8 can be created from the four pure tones in Figure V7 being generated separately (by mechanisms which are not related) and existing at the point of measurement as sound pressures simultaneously. The resulting sound pressure measurement then in the time domain would be that shown in Figure V8 (blue) and its FFT in Figure V9. However it is also possible that the signal shown in Figure V8 be generated acoustically by a single mechanism creating a pulse like pressure disturbance at a rate of.8hz.

Appendix V7 Amplitude Modulation The term amplitude modulation (AM) generally refers to the technique used in telecommunications to transmit information using radio frequency electromagnetic waves by modulating the amplitude of a high frequency carrier wave (that is much higher than signal of information e.g. an audio tone of 1Hz added to a carrier frequency of 72,Hz). Figure V1: Typical representation of AM for a radio wave For telecommunications the information signal is embedded in the carrier wave by modulation of its amplitude using a modulation circuit containing a multiplier. The embedded signal is extracted using a demodulation circuit. However, the term amplitude modulation in a broad sense can apply to any tone which changes its amplitude (generally on a periodic basis) over time. For example if the volume of a pure tone issued from loudspeaker is turned up and down on a periodic basis over the entire sample time, then the resultant tone could be described as being amplitude modulated.

Appendix V8 Common notation for amplitude modulation is; c(t) = A c sin(2πf c t) [Carrier Signal] m(t) = A m sin(2πf m t) [Modulation Signal] Where: f c = The carrier frequency f m = The modulation frequency A c = The carrier amplitude A m = The modulation amplitude The modulated signal is created by adding an offset to the modulation and multiplying this by the carrier wave. y(t) = [1 + m(t)] c(t) [Amplitude modulation signal] y(t) = [1 + A m sin(2πf m t) ] A c sin(2πf c t) Equation V1 It can be shown that y(t)can be represented by the sum of three sinusoids. y(t) = A c sin(2πf c t) + A ca m [sin(2π(f 2 m + f c )t) + sin(2π(f m f c )t) ] Equation V2 The result frequency content of the AM signal can be deconstructed into a tone at the carrier frequency f c and two tones at (f m + f c ) and (f m f c ) known as sidebands. In dealing with modulation of audio frequencies including infrasound associated with the turbines, the difference between the signal and the carrier is much smaller (than the radio wave) such that in many cases the amplitude modulation of the time signal is not that obvious. For a theoretical application of amplitude modulation, when restricted to the acoustic frequencies of concern for a wind turbine assessment, the following analysis considers the application of a carrier tone of 31.5Hz and a modulation tone of.8hz as shown in Figures V11 and V12.

Appendix V9 1.5 31.5Hz Tone.5.8Hz Tone 1.4.3.5.2.1 -.5 -.1 -.2-1 -.3 -.4-1.5 2 4 6 8 1 Time (s) Figure V11: 31.5Hz carrier tone [c(t): f c = 31. 5; A c = 1] -.5 2 4 6 8 1 Time (s) Figure V12:.8Hz modulation tone [c(t): f c = 31. 5; A c = 1] The analysis of the modulation and the carrier signals in Figure V11 and Figure V12, results in the modulated time signal (and the expanded view) shown in Figure V13 with the corresponding FFT in Figure V14..8 AM: Carrier = 31.5Hz; Modulation =.8Hz AM: Carrier = 31.5Hz; Modulation =.8Hz (Zoomed).8.6.6.4.4.2.2 -.2 -.2 -.4 -.4 -.6 -.6 -.8 2 4 6 8 1 Time (s) -.8 5 5.5 6 6.5 7 Time (s) Figure V13: AM signal [y(t): (f c = 31. 5; A c = 1) (f m =. 8; A m =. 2)]

db re (Max signal level) db re (Max signal level) The Results of an Acoustic Testing Program Cape Bridgewater Wind Farm Appendix V1 FFT of AM: Carrier = 31.5Hz, Modulation =.8Hz FFT of AM: Carrier = 31.5H - - -1-1 -1 1 2 3 Frequency (Hz) Figure V14: FFT of AM signal [y(t): (f c = 31. 5; A c = 1) (f m =. 8; A m =. 2)] -1 3 3.5 31 Freq The 31.5Hz tone was used as a carrier wave and modulated by the.8hz tone. This results in a time signal as shown in Figure V13 which shows the amplitude of the 31.5Hz tone is modulated at the.8hz rate. This corresponds to the following time signal from Equation V1; y(t) = [1 + A m sin(2πf m t) ] A c sin(2πf c t) = [ 1 + (.2) sin(2π(.8)t) ] sin(2π(31.5)t) 2 Or by substituting the modulation and carrier signal values into Equation V2; y(t) = sin(2πf c t) + A ca m 2 [sin(2π(f m + f c )t) + sin(2π(f m f c )t) ] = sin(2π(31.5)t) +.2 [sin(2π((.8) + (31.5))t) + sin(2π((.8) (31.5))t) ] 2 = sin(2π(31.5)t) +.1[sin(2π(32.3)t) + sin(2π(3.7)t) ] = sin(2π(31. 5)t) +. 1 sin(2π(32. 3)t) +. 1 sin(2π(3. 7)t)

db re (Max signal level) The Results of an Acoustic Testing Program Cape Bridgewater Wind Farm Appendix V11 This is shown in the FFT result in Figure V14. Figure V15 shows the time signal result of a similar exercise, that is, amplitude modulating a 31.5Hz tone using the signal shown in Figure V8 (spectrum shown in Figure V9) for modulation. The FFT (Figure V16) shows multiple side bands corresponding to the spectrum of the modulated signal centred around the 31.5Hz tone. 1.5 AM: Carrier = 31.5Hz; Modulation =.8Hz w/harmoics (Pulse) 1.5 -.5-1 -1.5 1 2 3 4 5 6 7 8 9 1 Time (s) Figure V15: AM signal [y(t): (f c = 31. 5; A c = 1) ] FFT of AM: Carrier = 31.5Hz; Modulation =.8Hz w/harmonics (Pulse) - -1-1 -2-2 -3 5 1 15 2 25 3 35 45 Frequency (Hz) Figure V16: FFT of AM signal [(f c = 31. 5; A c = 1) ] (modulation using Figure V8)

Appendix V12 In the case of AM modulation where a tone is modulated, frequency analysis will show the spectrum of the modulation signal as side bands around the carrier frequency. This is well described by detailed AM modulation theory and analysis not shown here. However the result of the outcome is demonstrated by the preceding quantitative analysis. Signals & Systems Basic Concept A fundamental result when dealing with linear systems is that, for a single sinusoidal signal at a particular frequency, the steady state output will be a sinusoid at the same frequency as the input tone, with an amplitude scaling and phase shift associated with the system. Any combination of sinusoidal signals at discrete frequencies passed through a linear system will result in an output containing those particular discrete frequencies with amplitude scaling and phase shift associated with the system. This result can be extended to any signals passed through linear systems and importantly in this context, to signals which are perhaps not sinusoidal but periodic in nature and can be deconstructed into discrete sinusoidal tones. No intermodulation tones are created by passing signals through linear system e.g. no intermodulation tones are created by passing two tones into an RLC filter circuit (operating linearly) simultaneously. If a system has nonlinearities, intermodulation (e.g. sideband terms) are created (note the multiplication in the AM discussion is a nonlinear operator). For example if the two tones used to create amplitude modulation in Figure V11 and Figure V12 are added together (i.e. linearly combined) the FFT will show simply the two discrete tones (Figure V17).

db re (Max singal level) db re (Max singal level) The Results of an Acoustic Testing Program Cape Bridgewater Wind Farm Appendix V13 1.5 Addition: 31.5Hz;.8Hz 1.5 AM: Carrier = 31.5Hz; Modulation =.8Hz 1 1.5.5 -.5 -.5-1 -1-1.5 2 4 6 8 1 Time (s) -1.5 2 4 6 8 1 Time (s) 1.5 Addition: 31.5Hz;.8Hz (Zoomed) 1.5 AM: Carrier = 31.5Hz; Modulation =.8Hz (Zoomed) 1 1.5.5 -.5 -.5-1 -1-1.5 5 5.5 6 6.5 7 Time (s) -1.5 5 5.5 6 6.5 7 Time (s) FFT of Addition: 31.5Hz;.8Hz FFT of AM: Carrier = 31.5Hz; Modulation =.8Hz - - -1-1 -1 1 2 3 Frequency (Hz) -1 1 2 3 Frequency (Hz) Figure V17: Two signals added linearly (Left) vs. AM Modulation (Right) Figure V17 shows a time signal and frequency analysis comparison between signals which are linearly added and those which are modulated (i.e. non-linearly combined). The left-hand side graphs show the addition of the signals shown in Figure V11 and Figure V12 i.e. 31.5Hz and.8hz tones. The right-hand side shows the AM modulation of the same signals. No intermodulation terms are created when the two signals are added. The FFT of the addition of the signals shows only the discrete tones at 31.5 and.8hz. Whereas the AM modulation shows the carrier frequency 31.5Hz with side bands of the modulation at.8hz. Importantly for considering turbines the AM shows no.8hz tone.

Appendix V14 Blade Pass Frequency Signal Using the theory presented in the analysis of wind turbine noise measurements an explanation is proposed of what is giving rise to the acoustic signature. Frequently measurements for turbines when operating show peaks in the infrasound region associated with the blade pass frequency and its harmonics. The blade pass frequency and harmonics suggest there is a periodic signal at the blade pass frequency which is not a pure tone (the fact it has harmonic content suggests this). Generally the spectra show the first 4-5 harmonics of the nominal blade pass frequency, depending on prevailing wind conditions, with the fundamental frequency at Cape Bridgewater being approx..85hz. An example of this concept is demonstrated in Figure V18 showing a linear averaged 1 minute FFT result of a measurement taken using a pressure detector in the living room of House 87. A sample of the time signal giving the FFT result in Figure V18 is shown in Figure V19. presdetec-22_5-53-on (Real) 7 3 1 2 3 4 5 6 7 8 9 1 Figure V18: House 87 Pressure Detector 22/5/14 5:3am (Turbines ON) - 1min FFT result

Pa Pa The Results of an Acoustic Testing Program Cape Bridgewater Wind Farm Appendix V15 Figure V19: House 87 Pressure Detector 22/5/14 5:3am (Turbines ON) Time signal sample By taking the amplitude at the peaks corresponding to the blade pass frequency and its harmonics an approximation to the underlying signal can be synthesised. In Figure V2 the first fundamental and first 5 harmonics have been added to produce an approximation of the pressure signal responsible for the harmonic peaks seen in Figure V18..5 Blade Pass Frequency Harmonics - Time Signal Synthesis.5 Blade Pass Frequency Harmonics - Time Signal Synthesis (Zoomed).4.4.3.3.2.2.1.1 -.1 -.1 -.2 -.2 -.3 -.3 -.4 -.4 -.5 1 2 3 4 5 6 7 8 9 1 Time (s) -.5.5 1 1.5 2 Time (s) Figure V2: Blade pass harmonics time signal synthesis - House 87 Pressure Detector 1/6/14 8:2pm

Appendix V16 As discussed regarding the FFT results, it is possible that each sinusoidal tone used to synthesis the time signal shown in Figure V2 is the result of the harmonic components being discretely generated simultaneously, producing the time signal and FFT result. However considering the mechanics of a wind turbine, another possibility is that the harmonics of the blade pass frequency shown in FFT analysis are the result of a pulse wave at the blade pass frequency. In many cases the FFT results that show the fundamental peak at the blade pass frequency is lower in magnitude than the magnitude of the harmonics. This is not explained by single pulse waves at the blade pass frequency, which would show the fundamental peak having the largest magnitude. However if one uses the hypothesis that a single turbine radiates a pulse like pressure disturbance at the blade pass frequency, then when considering measurements in the sound field of multiple turbines, one would need to consider phasing effects likely to occur due to the spacing of the turbines and the measurement position. The variation in the blade pass frequency and potentially the orientation of the turbines would also have an impact on the amplitude and phasing relationship of the harmonics. The BFP in Figure V19 is not as obvious as it is when represented in Figure V2. However, due to the stochastic nature of the way multiple turbines interact and operate under this hypothesis when viewed from a purely acoustic measurement perspective, it is unlikely that the patterns that appear in the FFT would be observed by looking at time signals. This is in fact the utility of the FFT analysis, in that it can extract underlying patterns in a signal which contain stochastic processes (or randomness) which in this case includes the general ambient noise and wind effects. However it should also be noted that using linear averaged FFT results will be affected by wind gusts, which may mask the blade pass harmonics. Variation in the speed of the turbines, phasing effects and turbine orientations further complicate the appearance of the time signal. These variations occur throughout the measurement period, causing any particular sample that is observed as a time signal to appear perhaps, as having random pressure fluctuations or no significance depending on the wind conditions and turbine operation. Nonetheless, Figure V19 shows a general pulse like signal similar to that which may be expected. The peak-peak variation over a small period (i.e. excluding the slow variation) in Figure V19 is close to the synthesised peak-peak level (.8Pa) in Figure V2.

Appendix V17 Figure V21: Turbine 13 Downwind Centre (9/7/214 3:46:19 PM) Time signal samples Figure V21 shows the results of the time signal recorded under CBW Turbine 13 where significant peak-peak pressure pulses similar in nature to those estimated in Figure V2. Not all of the time signals recorded around turbine CBW 13 exhibit the pulse characteristic shown in Figure V21 suggesting the infrasound noise source exhibits directionality. If measurements were made to establish the acoustical nature of a pressure pulse occurring from a turbine, it is suggested that the measurements were in the field of only a single turbine. The measurements should specifically identify any operational variation and directionality effects that occur, to ensure an accurate model is obtained.