AMPLIFIER RESEARCH... APPLICATION NOTE: 19

Similar documents
AMPLIFIER RESEARCH... APPLICATION NOTE: 20

AMPLIFIER RESEARCH... APPLICATION NOTE: 23

Model AS08010, M1 AR System 10kHz 8GHz

Specification for Radiated susceptibility Test

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

CONDUCTED RF EQUIPMENT POWER AMPLIFIERS. Practical RF Immunity System Design Considerations

pel.com Microwave & RF, March 23 rd, 2016.

Advanced Test Equipment Rentals ATEC (2832)

EMC Test Facility Sale

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

Model AS18071, M1, M2 AR System 10kHz 18GHz

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

We re In The Business Of Making Your Life Easier

Application Note #38B Automotive 600V/m Radar Pulse Test Solution

EMC ANECHOIC CHAMBERS 5-METER CHAMBERS

Test and Measurement for EMC

RIGOL Presents: New Solutions for Affordable Pre- Compliance Testing

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

Test specification: Section (e)(1), Radiated emissions below 40 GHz Test procedure: ANSI C63.4, Sections 8.3.2, 13.2, 13.4 Test mode: Compliance

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

Failing EMC testing? > 50% of products fail EMC testing first time around

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to

How will the third edition of IEC affect your test facility?

Electromagnetic Compliance: Pre-Compliance Test Basics October 19, 2017

Future In Radiated Immunity Testing

Semi Anechoic Chamber (SAC)

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

RADIOMETRICS Midwest Corporation

Large E Field Generators in Semi-anechoic Chambers for Full Vehicle Immunity Testing

CHAPTER 6 EMI EMC MEASUREMENTS AND STANDARDS FOR TRACKED VEHICLES (MIL APPLICATION)

Modulated Wideband Power Amplifier

FISCHER CUSTOM COMMUNICATIONS, INC.

Sunlight Supply, Inc.

Trees, vegetation, buildings etc.

LS200 TEST DATA IEC61000 SERIES

Keysight Technologies Essential Capabilities of EMI Receivers. Application Note

Shielding Effectiveness Summary Results for RadiaShield Technologies, Inc. RadiaShield Fabric

RADIATED EMISSIONS MEASUREMENTS IN AN OPEN AREA TEST SITE

Ave output power ANT 1(dBm) Ave output power ANT 2 (dbm)

RF Test Accessories. Antenna Coupler. TC-93010C fitted with F930102A TC-93013A. Frequency Range : 820 ~ 960 MHz. Frequency Range : 0.

Measurement Notes. Note 63. March Automated and Adaptive RF Effects Testing

PARALLEL ELEMENT ANTENNA MODEL PEA-30

Advanced Test Equipment Rentals ATEC (2832)

LOG PERIODIC ANTENNA MODEL LPA MHz - 1 GHz

EMC LAB EQUIPMENT CALIBRATION SCHEDULER

CS114 + CS115 + CS116

Qualtest, Inc. Report: REPORT REVISION RECORD

Application Note #41A Update on the latest release of IEC , Edition 3

E M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m

INSTRUCTION MANUAL TRI-PLATE LINE MODEL EM-7310

Application Note #60 Harmonic Measurement for IEC And other Radiated Immunity Standards

EMC Near-field Probes + Wideband Amplifier

Main features. System configurations. I Compact Range SOLUTION FOR

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

E-Field Uniformity Test Volume In Gtem Cell Based On Labview

Regarding RF Isolation for small Enclosures

Accredited calibration of field strength meters

LTE Band 7. Channel

DTE Power via MDI Task Force P802.3af

L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI

An Introduction to EMC Testing (what can be done with scopes) Vincent Lascoste EMC Product Manager - RSF

REVERBERATION CHAMBER FOR EMI TESTING

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

E MC Ane c hoi c Chambers

No. 1. BROADBAND RF-POWER-AMPLIFIERS 10 khz - 6 GHz. For immunity tests according to IEC, EN, ISO, SAE, MIL

Software. Equipment. Add-ons. Accessories. Services

EMC & Electrical Test Laboratory EMC LAB EQUIPMENT RESOURCES PER OEM TEST METHOD EQUIPMENT DCX FORD GM

Advanced Compliance Solutions, Inc FAU Blvd, Suite 310 Boca Raton, Florida (561)

GTEM cells. Emissions and immunity testing in a single, shielded environment

EMC TEST EQUIPMENT & E M C PRODUCT OVERVIEW

TEST REPORT... 1 CONTENT...

FCC 15B Test Report. : BTv4.0 Dual Mode USB Dongle. Address : Thompson Ave. / Lenexa, Kansas / / USA

Test Laboratory No Accredited by CAI for Electromagnetic Compatibility, Electrical Safety and Electrical Cable Tests

Double-Ridged Waveguide Horn Antennas

Essential Capabilities of EMI Receivers. Application Note

TEST REPORT: ELECTROMAGNETIC COMPATIBILITY - ESA Regulation Consolidated to Supplement 2 (Revision 4 Amendment 2)

Laird Attn: Bill Steinike W66 N220 Commerce Ct. Cedarburg, WI Report Constructed by: Zach Wilson, EMC Technician Signature: Date: June 21, 2017

2620 Modular Measurement and Control System

GTEM For emission and immunity testing according to IEC/EN Introduction

We ve Bent The Rules. AR s Bent-Element Approach Provides A Size Reduction Of Up To 75%, Along With Great Performance.

EMC Evaluation at Green Bank: Emissions and Shield Effectiveness

Electromagnetic Compatibility ( EMC )

RF Conducted Immunity and Automotive Transient Generator Test Systems

ENGINEERING TEST REPORT #: A LSR JOB #: C-2411

Characterization of a Photonics E-Field Sensor as a Near-Field Probe

Mhow (MP) PIN c/o 56 APO RFI : PROCUREMENT OF FAST TRANSIENT RESPONSE ELECTROMAGNETIC PULSE (EMP) SIMULATOR

Date: ESPOO Page: 1 ( 10) Appendices - Transceiver. SATELLINE-EASy Pro 35W SATEL-TA18 SATEL Oy, Finland

Reverberation Chambers Design and Construction Considerations for Aerospace and Military Test Requirements

Title: Test on 5.8 GHz Band Outdoor WiFi (802.11b/g) Wireless Base Station

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

System description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7

Practical Considerations for Radiated Immunities Measurement using ETS-Lindgren EMC Probes

Martec/Wayne Dalton Transmitter Model(s): 3977

FCC Part 22/24 Compliance Test Report

Electromagnetic Effects, original release, dated 31 October Contents: 17 page document plus 13 Figures. Enclosure (1)

Table of Contents 1. GENERAL INFORMATION SYSTEM TEST CONFIGURATION CONDUCTED EMISSIONS TEST RADIATED EMISSION TEST...

DARE!! Instruments Application Note GHz Radiated RF Immunity Testing

RADIATED IMMUNITY TEST SYSTEM 6 GHz

Calibration and Validation for Automotive EMC

Transcription:

AMPLIFIER RESEARCH... APPLICATION NOTE: 19 AMPLIFIER RESEARCH PRODUCTS THAT PROVIDE 10 V/m CW OR PM AT A DISTANCE OF 1 METER 1 The Amplifier / Antenna / Cell combinations shown in Table 1 provide various means of generating 10 V/m, CW or Pulse Modulated, inside a TEM Cell or ARCell, between the elements of an E-field generator, or at a distance of one meter from a radiating antenna, from 10kHz to 18GHz. This table is used in conjunction with the enclosed product selection flow chart and system diagrams. The appropriate combination of products is determined by first noting the physical size of the Device Under Test (DUT). The size of the test object determines the appropriate path taken on the flow chart. Follow the path that accommodates the maximum expected DUT size. As an example, to test a device 16 inches or less on a side across the entire frequency band from 10kHz to 18GHz, select items 13, 14, 15, 16, and 17. If the test object were greater than 39 inches, items 1, 2, 3, 4, and 5 would be appropriate. When testing small objects, a TEM cell offers an economical solution in that it is used in lieu of both a radiating antenna and a shielded enclosure. For a test object 4 inches or less in height, select items 21 and 22. If the DUT is 2 inches or less in height, then items 23 and 24 can be used. The TC1000A, TC2000C, TC3000A, and TC4000A ARCells offer semi-anechoic performance and also include built in field generators. ARCells offer convenient, cost effective alternatives to conventional susceptibility test systems consisting of a shielded room or anechoic chamber. With four enclosures to choose from, one can test devices from 12 /side to 39 /side from 10kHz to 4.2GHz. The maximum field level, frequency range, and test volume is cell dependent. See the Know Before You Go ARCell brochure and Application Note 34 for details. To accurately determine field strength in the area of the DUT, a field monitor such as the Amplifier Research FM5004 and an appropriate field probe are required. Contact the factory for specific recommendations. The power amplifier recommendations that follow provide sufficient margin and should prove adequate to accommodate nominal system losses. Rev090401

10 V/m CW OR PM AT A DISTANCE OF 1 METER 1 ITEM 2 FREQUENCY AMPLIFIER ANTENNA or CELL DUT PLACEMENT 1 10kHz-100MHz 75A250 AT5000M3 1 meter 2 100MHz-1GHz 10W1000C AT1080 1 meter 3 1GHz-4GHz 1S1G4A AT4002A 1 meter 4 4GHz-8GHz 1 meter 5 8GHz-18GHz 1 meter 6 27MHz-1GHz 30W1000B TC4000A 3 meters 7 1GHz-2.7GHz 25S1G4A TC4000A 3 meters 8 27MHz-1GHz 30W1000B TC3000A >1 meter 9 1GHz-2.7GHz 25S1G4A TC3000A >1 meter 10 10kHz-250MHz TC2000C < 1 meter 11 250MHz-1GHz 10W1000C TC2000C <1 meter 12 1GHz-4.2GHz 10S1G4A TC2000C <1 meter 13 10kHz-100MHz AT3100 Between Elements 14 100MHz-1GHz 10W1000C AT1080 1 meter 15 1GHz-4GHz 1S1G4A AT4002A 1 meter 16 4GHz-8GHz 1 meter 17 8GHz-18GHz 1 meter 18 10kHz-250MHz TC1000A <1 meter 19 250MHz-1GHz 10W1000C TC1000A <1 meter 20 1GHz-2.7GHz 10S1G4A TC1000A <1 meter 21 10kHz-250MHz TC3020A Center of Cell 22 250MHz-375MHz 1W1000B TC3020A Center of Cell 23 10kHz-250MHz TC1510A Center of Cell 24 250MHz-750MHz 1W1000B TC1510A Center of Cell Table 1 1 The rf fields generated by the products recommended in this application note are either CW or pulse modulated, and occur at a distance of one meter unless otherwise noted. If the application mandates amplitude modulation, additional amplifier power is required to produce undistorted, linear fields. Call Application Engineering at 800-933-8181 for details.

2 The Item numbers match the Block numbers on the enclosed Product Selection Flow Chart. Rev090401

10V/m CW or PM @ 1M* Amplifier/Antenna/Cell Selection Chart >39 AT5000M3 75A250 1 AT1080 10W1000C AT4002A 1S1G4A 2 3 4 5 39 TC4000A 30W1000B TC4000A 25SIG4A 6 7 39 TC3000A 30W1000B TC3000A 25S1G4A 8 9 20 16 TC2000C AT3100 TC2000C 10W1000C AT1080 10W1000C TC2000C 10S1G4A 10 11 12 AT4002A 1S1G4A 13 14 15 16 17 12 TC1000A 18 TC1000A 19 TC1000A 20 10W1000C 10S1G4A 4 TC3020A 21 22 TC3020A 1W1000B 2 TC1510A TC1510A 1W1000B 23 24 10kHz 27MHz 100MHz 250MHz 1GHz 2.7GHz 4GHz 8GHz 18GHz * The numbered cells represent either Amplifier / Antenna or Amplifier / Cell combinations. The actual distance from the field generator to the DUT may vary from 1 meter. See Table 1 for details. Rev090401

TYPICAL PRE-COMPLIANCE SUSCEPTIBILITY TEST SYSTEMS (Use in applications that call for "Leveled" or "Real-Time" testing) RF Source Pre-Amplifier Power Amplifier (Optional) Radiating Antenna Personal Computer w/ GPIB Card Field Monitor Fiber Optic Cable Field Probe HARDWARE LEVELED SYSTEM DeviceUnder Test Anechoic or Shielded Room RF Source Power Amplifier Radiating Antenna Field Probe DeviceUnder Test Personal Computer w/ GPIB Card Field Monitor Fiber Optic Cable Anechoic or Shielded Room GPIB Cable FIELD LEVELED VIA SOFTWARE Figure 1 Rev122199 Rev090401

FULL COMPLIANCE SUSCEPTIBILITY TEST SYSTEM (Use in applications that call for "Substitution Method" testing) RF Source Power Amplifier Dual Directional Coupler Power Meter Radiating Antenna Fiber Optic Cable Field Probe DeviceUnder Test Personal Computer w/ GPIB Card Field Monitor Anechoic or Shielded Room GPIB Cable Figure 2 Rev122199 Rev090401