Designing 100kHz, flyback transformers for input voltage vdc and power up to 500W

Similar documents
How should one design a 250kHz, 120W forward transformer with voltage controller, for input voltage range 200V to 350V, as per IEC 61558?

How should one design a 50kHz, 1200VA transformer as per IEC 61558?

Technical specification relevant only to design. Electrical data and diagram. Frequency. Nominal output voltage. Nominal output current

Topic 4 Practical Magnetic Design: Inductors and Coupled Inductors

DESIGN AND TECHNOLOGY OF THE MAINS SINGLE PHASE, LOW POWER TRANSFORMER

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

Magnetics Design. Specification, Performance and Economics

Designers Series XIII

Designing a 50W Forward Converter Transformer With Magnetics Designer

Iron Powder Cores for High Q Inductors By: Jim Cox - Micrometals, Inc.

Iron Powder Core Selection For RF Power Applications. Jim Cox Micrometals, Inc. Anaheim, CA

Glossary of Common Magnetic Terms

Wide ouput range power supply

R. W. Erickson. Department of Electrical, Computer, and Energy Engineering University of Colorado, Boulder

Low AC Resistance Foil Cut Inductor

Renco Electronics, Inc.

Transformers for Offline Flyback Converters

HP1, HPH1 HP2, HPH2 HP3, HPH3 HP4, HPH4 HP5, HPH5 HP6, HPH6. Winding Layout. Middle 11. Inner

Magnetics. Selection guide for a coupled inductor used in Sepic DC/DC Converter. Application Note. BI Technologies

Basic High Voltage / Horizontal Deflection

Windings for High Frequency

West Coast Magnetics. Advancing Power Electronics FOIL WINDINGS FOR SMPS INDUCTORS AND TRANSFORMERS. Weyman Lundquist, CEO and Engineering Manager

Transformer and Inductor Design for Optimum Circuit Performance

Switch Mode Power Supplies and their Magnetics

Telemetrie-Messtechnik Schnorrenberg

Flyback transformer design considerations for efficiency and EMI

LEAKAGE FLUX CONSIDERATIONS ON KOOL Mµ E CORES

Laminate Transformer Testing

Optimizing Custom Magnetics for High-Performance Power Supplies

DESIGN TIPS FOR L6561 POWER FACTOR CORRECTOR

The Ins and Outs of Audio Transformers. How to Choose them and How to Use them

What is an Inductor? Token Electronics Industry Co., Ltd. Version: January 16, Web:

Planar Transformer Prototyping Kit. Designer s Kit C356

Switching Frequency and Efficiency: A Complex Relationship

Use of inductive heating for superconducting magnet protection*

HOME APPLICATION NOTES

The Flyback Converter

Practical Tricks with Transformers. Larry Weinstein K0NA

LM78S40 Switching Voltage Regulator Applications

Experience the Power of Confidence

Bridgeport Magnetics Design Guide

Improved High-Frequency Planar Transformer for Line Level Control (LLC) Resonant Converters

DUAL STEPPER MOTOR DRIVER

CITY UNIVERSITY OF HONG KONG

Lecture 6 ECEN 4517/5517

Shielded Power Inductors

Ferrite Transformer Testing

Large Kool Mµ Core Shapes

800 W PFC evaluation board

Outcomes from this session

ELEC4240/ELEC9240 POWER ELECTRONICS

Differential-Mode Emissions

Inductors & Resonance

Large Kool Mµ Core Shapes

The Reliable Source... FERROPERM. Inductors. Transformers

Lecture 16 Transformer Design

Impact of Fringing Effects on the Design of DC-DC Converters

Switching Power Supplies

SHARDA Make Harmonics Filter

Achieving Higher Efficiency Using Planar Flyback Transformers for High Voltage AC/DC Converters

Leakage Flux Recovery Coil for Energy Harvesting Using Magnetoplated Wire

AN1606 APPLICATION NOTE A BRIDGELESS P.F.C. CONFIGURATION BASED ON L4981 P.F.C. CONTROLLER.

Fundamentals of Power Electronics

TUTORIAL Inductor Loss Calculation in Thermal Module

Target Temperature Effect on Eddy-Current Displacement Sensing

Selecting the Best Inductor for Your DC-DC Converter Leonard Crane Coilcraft

Wire Wound Chip Inductors LPI0805FT Series

MICROCONTROLLER BASED BOOST PID MUNAJAH BINTI MOHD RUBAEE

SMA MAGNETICS. Efficient solutions for electrotechnical sector

ECONO-PAC /OCTA-PAC OCTA-PAC PLUS Power Inductors and Transformers

Application Note. Application for Precision Impedance Meters in a Standards Laboratory. Required Capabilities for Precision Measurements

COMPLIANT Common Mode Chokes - UU9.8 & UU10.5 Series

Inductor Glossary. Token Electronics Industry Co., Ltd. Version: January 16, Web:

The Future for SMPS Magnetics

MIC2171. General Description. Features. Applications. Typical Application. 100kHz 2.5A Switching Regulator

Large Kool Mµ Core Shapes

AT2596 3A Step Down Voltage Switching Regulators

An Interleaved Flyback Inverter for Residential Photovoltaic Applications

DC-to-DC Converter for Low Voltage Solar Applications

Conventional Single-Switch Forward Converter Design

7.2 SEPIC Buck-Boost Converters

Realisation of the galvanic isolation in customer-end DC to AC inverters for the LVDC distribution

LLC Resonance Power Transformers Using Magnetoplated Wire. and Shigeaki Tsuchiya b,

SMALLER-FASTER- OW R CO$T

HIGH FREQQUENCY TRANSFORMER DESIGN PROGRAM MANUAL V12.0

TL-W. Standard Flat Inductive Proximity Sensors. Ordering Information. Front and side facing surface IP67 DC 2-wire and DC 3-wire models

discontinued October 31, 2017 or until inventory is

Walchand Institute of Technology. Basic Electrical and Electronics Engineering. Transformer

Medium Power 137kHz Linear Power Amplifier G4JNT Sept 2010

TOPSwitch for Telecom and

SOME STUDIES ON HIGH FREQUENCY RESONANT INVERTER BASED INDUCTION HEATER AND THE CORRESPONDING CHOICE OF SECONDARY METALLIC OBJECTS

Volts Volts. Pout < 4.0W (See Fig 8/9) Pout < 11.5W (See Fig 8/9) EnablePin Threshold uamps In to/out of enable pin: Venable = 0-16V

By Hiroo Sekiya, Chiba University, Chiba, Japan and Marian K. Kazimierzuk, Wright State University, Dayton, OH

COMPONENTS MODULES CORES

Common Mode Filter Inductor Analysis

Reference Design EBC iw for 12V 600mA Network Adapter Design

TRAFTOR WINDINGS CHANGING THE RULES TOROIDAL INDUCTORS & TRANSFORMERS SOLUTIONS PROVIDER AND MANUFACTURER

Finite Element Analysis (FEA) software. Magnetic component design. 3D Electromagnetic Simulation Allows Reduction of AC Copper Losses

IEC Standard Caledonian Offshore & Marine Cables

Dry Type Distribution Transformers NON-LINEAR TRANSFORMER PRESENTATION

Transcription:

In the beginning Designing 100kHz, flyback transformers for input voltage125-700vdc and power up to 500W Thirty years ago, designers calculated transformers on their pocket calculators. The designer had to pencil in all the input and output fields onto a form and then feed them into the calculator. Today, he can forget the pencil, but he still has to enter the figures into spread-sheet programs such as Excel and Lotus 123 After the first economical 8-bit computer became available in 1978, professionals could begin to develop programs to design transformers and inductors. This development went in two directions: First, companies developed their own computer programs to meet their own specific requirements. These usually used already available algorithms and experience. After reaching acceptable levels to meet the company s needs both in technical capability and ease of use, further development ceased. Secondly, small companies began to develop professional computer programs which are sold or leased to the manufacturers of transformers and inductors. With continuous input from the various manufacturers, they were able to develop universal, powerful, easy-to-use tools for use throughout the industry. Designing with the Rale Design System The Rale Design system automatically calculates designs for transformers and inductors. Consequently, its data base incorporates all the necessary materials including cores, bobbins, wires, steels, etc. in both metric and USA units. This data base is totally user expandable. To use the programs, the designer needs only a basic knowledge of transformers or inductors and their operation mode. The designer does not need to use any complicated formulas, he only needs to follow two simple phases: The user only fills in the input mask with the global parameters (voltage, current, temperature rise, regulation, etc.) and runs the program. After the design is finished by the program the user can switch to the Test Mode and change by hand the parameters of the designed transformer (turns, wire sizes, steel,...) and run the program in order to redesign it. In this phase the user can also test his design, changing the input voltage, frequency, load, duty cycle,... The Operating Modes of a Flyback Transformer The following flyback transformer diagram illustrates only the parameters relating to its design. 1

2

With a flyback transformer, the distinction is drawn between two modes of operation: Mode with continuous secondary current ( Fig. 1, t3=0). Mode with intermittent DC secondary current (Fig. 2, t3>0). Continuous mode (Fig.1) In this mode, secondary current ripple is less than 100%: 3 Ripple = 100* (Ismax-Ismin)/(Ismax+Ismin) =(Bmax-Bmin)/(Bmax+Bmin) < 100 In the flyback transformer s continuous mode, the output voltage is "impressed" for practical purposes, and is not greatly dependent upon load. Because the variation of the duty cycle is not directly proportional to the variation of the input voltage, this mode is preferred for a wide range of the input voltages (min. 3:1). Secondly, the flyback transformer is larger with less ripple in the primary current. For that reason, the choice of ripple (10% to 100%) of the secondary current has to be harmonized between the transformer manufacturer and the electronics engineer. Intermittent mode (Fig.2) If the range of the input is not too wide (max. 3:1) then this is the most common operation mode because the flyback transformer is smaller than in the continuous operation mode: t1=t2 at minimal input voltage Ripple => 100%. Input only relevant to the design of a flyback Criterion for design Normally, high-frequency transformers have very low regulation and are designed according to the prescribed temperature rise. Since these transformers are manufactured almost exclusively using ferrite, the optimum operating temperature is around 100 C. Bobbin In order to protect the transistors, high-frequency transformers should be manufactured for low leaking reactance, with single-section bobbin units. For this reason, they often require bifilar or interleaved windings. Ferrite, Induction and Temperature rise Since the optimum operating temperature of ferrite for high-frequency transformers is around 100 C and their ambient temperature is 40 C, our design assumption must be for a temperature rise of 60 K. The program calculates both the active and the reactive core losses by hypothesizing the ferrite type, the frequency, the form of input voltage, induction and core temperature. The induction should be selected so that the transformer does not saturate at minimum input voltage, maximum duty cycle and maximum core temperature. If the core losses in relation to temperature rise are not economically acceptable, then the computer program will optimize or reduce the AC-

component (the ripple of the input current) of the induction automatically. But this indicates that the selected ferrite quality is not optimal. Copper additional losses With a high-frequency transformer, the distinctions are drawn between the following additional losses in a winding, over and above the dc-current losses: 1. Eddy current losses 2. Skin effect losses 3. Proximity effect losses 4. Losses due to circulating currents through the parallel-connected wires. Proximity losses are smaller in the case of a winding that takes up only 30-60% of the available winding space. For that reason, one should always set the input for the Space between 0.3 and 0.6 for purposes of automatic core selection by the program. The input for Rac/Rdc will limit the extent of additional losses. The computer program selects a high enough number of parallel-connected wires for the eddy current losses and skin effect losses to fall short of the prescribed value for Rac/Rdc. For that reason, the input for Rac/Rdc is also used for monitoring parallel-connected wires. The value is normally set between 1.25 and 3. Losses of circulating currents through the parallel-connected wires are not calculated. It is assumed that these additional losses have been eliminated by suitable design precautions. In particular, it should be ensured, for a given litz, that the twisting for the winding maintains the same position at the input and at the output of the winding for any given winding. Duty cycle at minimal input voltage 4

The duty cycle q is defined as follows: A flyback transformer with an automatic controller of output voltage and current ripple less than 100% is normally designed with the following parameters: "Nominal" input voltage Upnom= (Upmin*Upmax)1/2 = (125*700) 1/2= 296V. At this input voltage the duty cycle q nom will be 0.5. This flyback transformer has to be designed at the input voltage Upmin = 125V. At this input voltage the duty cycle will be: q max = Unom/(Umin + Unom) = 296/(125+296) = 0.7. Th duty cycle at the input voltage Upmax = 700V will be: q min = Upnom/(Upmax+Upnom) = 296/(700+296) = 0.3 Ripple of the input current at the minimal input voltage = 17% In order to have the ripple smaller than 100% at the maximal input voltage, you have to prescribe the ripple at the minimal input voltage as follows: Ripple min = Ripple max *(Upmin*q max /Upmax/q min )^2 = 100*(0.7*125/750/0.3)^2 < 17% 5

Procedure to design a 200W flyback transformer Normally the user loads the standard input file for the flyback transformer and fills in the input mask in accordance with the discussion above. Note that all other parameters (such as chassis, insulation, case, impregnation, ) are generally relevant to the transformer design and will not be discussed: Input voltage : U(V) = 125V Duty cycle : Formfactor = 0.7 Ripple of the primary current (induction) : di/io = 17% Output DC-voltage : Voltage = 2 x 24V Output DC-current ; Current = 2 x 4A Ambient temperature : Amb. Temp. = 40 C Temperature rise : Temp. rise = 60 K Induction = 0.275T 6

Single-section bobbin with the primary between 2 secondary : Bobbin = 11 Max. Build 50%: Space = 0.5 Factor for additional Cu-losses : Rac/Rdc = 3 If the core size is not prescribed by the user the input field Selection is set at 0. This means that the program should search for a suitable core for this application from your selected core family. In the system for automatic selection of the core from your prescribed core family, the program will offer you an adequately sized core for your application. On completion of the design work, the following design data will be available, which 7

can be saved and/or printed on 3 pages: 8

9

Checking the design However, there are two parameters, which relate exclusively to the flyback transformer: primary winding inductance (1.12 mh) and the gap (2x0.014") for calibration of the primary winding inductance at the nominal frequency. The winding filling factor :44%<100% 10

The maximum temperature of the windings is 40 C+57 K = 97 C < 115 C. The number of parallel-connected wires (litz) for the secondary only is 30 x WG 29. A copper foil can replace this litz. The foil thickness should correspond to the wire diameter of the litz (11.3 mill or less). The foil width should be matched to the width of the bobbin. The number of foils connected in parallel is determined in accordance with the following illustration. Using the Test Mode If the design data is not satisfactory, then you can access the test mode, modify the designed transformer manually (turns, wire size, steel, input voltage, load, duty cycle, ) and redesign the transformer by that means. The following output mask in the test mode shows the results by checking the output voltage for the maximal input voltage of 700V and the duty cycle of 0.3: Uin = 700/125 = 5.6. 11

The following table shows the summary of the most important parameters, calculated by the program in the test mode. Note that the duty cycle (q) was changed in order to get the nominal input voltage that a voltage controller would give. Ui V Iprms A 2xIsrms A 2xUodc V 2xIodc A Pcu W Pfe W Q Ripple % DTcu K 125 1.87 7.22 23.6 3.93 4.62 0.55 0.7 17.7 57.4 296 1.01 5.98 24.1 4.03 2.50 1.7 0.5 47.4 46.5 700 0.62 5.58 24.5 4.11 1.28 3.53 0.3 93 49.4 In order to get the constant total losses in the whole range of the input voltage, select the ferrite and the operation frequency at the nominal input voltage so that you get approximately Pfe = Pcu Technical specification common for all designs All flyback transformers in the following table were calculated under the same conditions: Input voltage : 125Vdc - 700Vdc Output voltages : 2 x 24Vdc Frequency : 100kHz Duty cycle : 0.7 at the input voltage 125V Ripple of the induction : 17% at the input voltage 125Vdc Peak induction : 0.25-0.28T Build of the windings : approx. 50% 12

Ambient temperature : 40 C Temperature rise : 60 K Core family and ferrite : ETD, N27 or better Order of the windings : Primary between both secondary The parameters of the designs are core size, output power and eddy current losses (Rac/Rdc) / Primary Secondary Core Rac/Rdc Power W Inductance mh Turns Parallel x Wire Gauge Turns Parallel x Wire Gauge ETD 19 1.3 23 8.8 242 1x37 2x5 1x29 ETD24 2 38 5.54 185 1x33 2x16 1x25 1.20 48 4.47 1x33 10x34 ETD29 2.9 60 3.34 142 1x30 2x12 1x22 1.9 75 2.8 1x29 9x30 1.20 85 2.43 2x32 40x36 ETD34 1.65 95 2.26 117 1x28 2x10 30x32 1.25 110 1.91 3x33 65x36 ETD39 2,75 125 1.73 94 1x25 2x8 22x29 1.90 145 1.46 2x29 50x32 1.25 177 1.19 6x33 140x33 ETD44 1.80 230 0.89 71 5x29 2x6 90x33 1.25 280 0.75 15x34 300x38 ETD49 2.00 330 0.65 59 10x30 2x5 200x34 1.20 423 0.50 40x36 750x40 13

About Designing of Flyback Transformers About Rale Input In order to design a flyback transformer with the Rale Design Software you need the following inputs: 1. Min. input voltage and the duty cycle at this voltage 2. Dc-output voltages and dc-output currents 3. The ripple of the input current (induction) 4. Frequency In the following Figure are 2 typical operation modes: Continuous mod Bmin>0 Discontinuous mode Bmin=0 14

User Input Some of customers use other inputs for designing of a flyback. Here are some typical cases Inductance of the primary winding You know: 1. Min. input voltage and the duty cycle at this voltage 2. DC-output voltages and dc-output currents (output power) 3. Inductance of the primary winding 4. Frequency Then you need to calculate the ripple of the primary Pout = L x (Imax^2-Imin^2) x f / 2 = L x (Imax+Imin) x (Imax-Imin) x f /2 Where: Using: Pout Output power in W L Inductance in H F Frequency in Hz Imax Max. primary current (peak) Imin Min. primary current Ripple%= 100 x (Imax-Imin)/(Imax+Imin) Iav = (Imax+Imin)/2 Pout = Uin x Iav x q We can calculate: Pout = 2 x L x Iav^2 x (Ripple%/100) x f or Ripple% = 100 x Uin^2 x q^2 / L / Pout / f / 2 (<=100) Formfactor = 1 / 2 / q Where: Uin Min. input voltage q Duty cycle of the primary Ripple% Ripple of the primary current dio/i = 100 x (Imax-Imin)/(Imax+Imin) 15

Ration of the primary and secondary turns in continuous operation mode You know: 1. Min. input voltage 2. DC-output voltages and dc-output currents (output power) 3. Inductance of the primary winding 4. Frequency 5. Ratio of the primary and secondary turns (T1/T2) 6. Continuous operation mode (s=p, Bmin>0, see Figure) Now you need to calculate the duty cycle (Formfactor) and the input dio/i: (Uin x q) / (Uout x s) = (T1/T2) s= p = 1 - q q = A/(1+A) and Formfactor = 1 / 2 / q Ripple% = 100 x Uin^2 x q^2 / L / Pout / f / 2 (<=100) Where: A = (Uout/Uin) x (T1/T2 Ration of the primary and secondary turns in discontinuous operation mode You know: 7. Min. input voltage 8. DC-output voltages and dc-output currents (output power) 9. Inductance of the primary winding 10. Frequency 11. Ratio of the primary and secondary turns (T1/T2) 12. Discontinuous operation mode (s<p, Bmin=0, see Figure) Now you need to calculate the duty cycle (Formfactor) and the input dio/i: The ripple of the primary current is 100% and the primary duty cycle can be calculated: Ripple% = 100 x Uin^2 x q^2 / L / Pout / f / 2 (<=100) and q = (2 x L x Pout x f)^0.5 / Uin (q has to be <1) s = q x (Uin/Uout) / (T1/T2) (s <= 1 - q) and 16

dio/i = 100 x (1- q) / s Formfactor = 1 / 2 / q Home 17