Contents Frenchwood Gliding Patio Doors Basic Unit Details Two and Four Panel...9-2 Sidelight...9-5 Options / Accessories Ramped Insert - Interior and Exterior...9-6 Grilles...9-7 Anchoring Methods...9-9 Joining Details... 9-10 Suggested Product Applications... 9-11 Low-maintenance, durable exterior available in White, Sandtone, Terratone or Forest Green colors Natural wood interior in pine, oak, maple or prefinished white Smooth, easy operation 20/10 year limited warranty, fully transferable non-prorated High-Performance Low-E tempered or High-Performance Sun Low-E tempered glass is standard A R C H I T E C T U R A L D E T A I L F I L E 9-1
Basic Unit Details - Two and Four Panel Basic Unit gliding insect screen. Retractable insect screen also available for two panel doors. 1-5/16" (33) 4-9/16" (116) End bumper beyond 1" (25) 13/16" (21) 5-13/16" (148) depending on panel adjustment 3-3/4" (95) Clear Opening Height oak or maple 1/4" (6) 10-9/16" (268) depending on panel adjustment 5/16" (8) metal sill support 1-13/16" (46) 5/8" (17) 9-2 A R C H I T E C T U R A L D E T A I L F I L E
Basic Unit Details - Two Panel Basic Unit Active Panel Stationary Panel 5- (137) 3-1/8" (79) 3-1/8" (79) 5- (137) 1- (35) 1-3/4" (44) 4-9/16" (116) 1-5/16" (33) Meeting Stile 50**=2' 5-5/8" (752) 80**=3' 11-5/8" (905) LC 50**=2' 5-5/8" (752) 80**=3' 11-5/8" (905) (10) Unit Dimension Width Rough Opening Width (10) Horizontal Section A R C H I T E C T U R A L D E T A I L F I L E 9-3
Basic Unit Details - Four Panel Basic Unit Stationary Panel Stationary Panel 1-3/4" (44) 5- (137) 3-1/8" (79) 3-1/8" (79) 3-1/8" (79) 3-1/8" (79) 5- (137) 1-3/4" (44) auxiliary foot lock auxiliary foot lock 4-9/16" (116) 1-5/16" (33) Meeting Stile Meeting Stile 10**=2' 5-11/16" (754) 12**=2' 11-11/16" (906) 16**=3' 11-11/16" (1211) LC LC 10**=2' 5-11/16" (754) 12**=2' 11-11/16" (906) 16**=3' 11-11/16" (1211) Active Panel 4-5/8" (117) 4-5/8" (117) Active Panel Astragal 10**=2' 4-13/16" (732) 12**=2' 10-13/16" (884) 16**=3' 10-13/16" (1189) LC 10**=2' 4-13/16" (732) 12**=2' 10-13/16" (884) 16**=3' 10-13/16" (1189) Horizontal Section 9-4 A R C H I T E C T U R A L D E T A I L F I L E
Basic Unit Details - Sidelight Basic Unit 1-5/16" (33) 4-9/16" (116) 1" (25) 13/16" (21) 4" (102) 5-13/16" (148) depending on panel adjustment Clear Opening Height 10-9/16" (268) oak or maple 1/4" (6) 5/16" (8) metal sill support 1-13/16" (46) 5/8" (17) 5-7/16" (138) 5-7/16" (138) 1-3/4" (44) 1-3/4" (44) 4-9/16" (116) 1-5/16" (33) Unit Dimension Width (10) (10) Rough Opening Width Horizontal Section A R C H I T E C T U R A L D E T A I L F I L E 9-5
Options / Accessories Ramped Insert - Interior and Exterior Exterior Ramp Track Cover Center Ramp 8 1 5/16" (8) (depending on roller adjustment) 1-9/16" (40) 1-7/16" (37) 1/4" (6) 1/4" (6) Flashing 5/8" (17) by others 10-1/8" (257) 10-7/8" (276) maximum. Cut to fit height. 5/16" (8) Note: Gliding insect screen cannot be used with ramped sill. Retractable insect screen can be used on 2 panel doors only. 5/8" (17) with Retractable Insect Screen (2 panel doors only) 9-6 A R C H I T E C T U R A L D E T A I L F I L E
Options / Accessories Divided Light Grilles Available now Available only with glass through the Andersen Divided Light program Please check with Andersen for availability Casement & Awning Casement Picture Window Gliding Window Woodwright Double-Hung & Transom Woodwright Picture Window Woodwright Archtop & Unequal Leg Archtop Andersen 400 Series Windows Woodwright Springline Single-Hung Tilt-Wash Double-Hung & Transom Tilt-Wash Picture Window Circle Top & Quarter Round Arch Springline Flexiframe Elliptical Circle & Oval Gothic 200 Series Narroline Double-Hung & Transom Andersen 400 Series Doors Frenchwood Gliding Frenchwood Hinged Inswing Frenchwood Hinged Outswing Frenchwood Patio Door Sidelights & Transoms Glass Patterns Interior Type Width Exterior Color White Sandtone Terratone Forest Green 3/4" 7/8" 1-1/8" 2-1/4" With Spacer Without Spacer Maple Oak Prefinished Pine Colonial Modified Colonial Modified Col W/Check Rail Prairie A Short Fractional Short Fractional W/Check Rail Tall Fractional Tall Fractional W/Check Rail Victorian Renaissance Sunburst Specified Equal Light Custom HP/HP Tempered HP Sun/HP Sun Temp Low-E/Temp Single-Pane Impact A R C H I T E C T U R A L D E T A I L F I L E 9-7
Options / Accessories 400 Series Grille Options Andersen Divided Light Permanent Exterior Permanent Interior with Spacer Andersen Divided Light Permanent Exterior Permanent Interior Andersen Divided Light Permanent Exterior Removable Interior Removable Interior Andersen Finelight Grilles-Between-the-Glass Grille Profiles Scale = Full Dimensions include thickness of tape. Permanent Exterior Fibrex Material Grille Profiles (chamfer profile). Also used for pre-finished interior, except 400 Series Woodwright double-hung windows. 5/16" 7/16" 1/2" 1-13/16" 45 45 35 45 5/16" 5/16" 5/16" 5/16" 3/4" 7/8" 1-1/8" 2-1/4" Permanent Interior Wood Grille Profiles (chamfer profile). The Fibrex material exterior grille is used when a permanent prefinished grille is specified, except with 400 Series Woodwright double-hung windows. 1/2" 1-13/16" 5/16" 7/16" 53 53 35 7/16" 53 3/32" 7/8" 3/4" 1-1/8" 2-1/4" Removable Interior Wood Grille Profile (roman ogee profile). Removable Interior Wood Grille Profile (Chamfer profile). 400 Series Woodwright double-hung windows only. 1/2" 7/16" 3/4" 7/8" 1-1/8" 3/4" 7/8" 1-1/8" Permanent Full Divided Light Grille spacer location. 1/2" 1/2" 1/2" 1/2" 1/2" 1/8" 3/16" 5/16" 1/8" Andersen Finelight Grilles-Between-the-Glass. 3/4" 1/2" 1" 9-8 A R C H I T E C T U R A L D E T A I L F I L E
Anchoring Methods Installation Flange Patio door unit is secured in opening using threaded fasteners through the jamb (the installation flange itself cannot support the door). Installation Flange Reversed Patio door unit is secured in opening using threaded fasteners through the jamb (the installation flange itself cannot support the door). 4-9/16" (116) 4-3/16" (106) Installation flange in reverse position. Exterior sheathing Installation flange Threaded Masonr y Fastener / Expansion Sleeve Patio door unit is secured in opening by pre-drilling through side jamb into masonry. Make sure that the unit frame parts do not become bowed when using anchoring methods. Unit will not operate properly if frame parts are stressed. Threaded masonry anchor (by others) A R C H I T E C T U R A L D E T A I L F I L E 9-9
Joining Details Joining Materials 1/16" (1.5) 1-3/4" (44) 1-3/8 (35) 2-5/8" wood casing Andersen wood casing Andersen LVL reinforced joining strip 3/4" (19) 1-3/4" (44) 1-3/8 (35) 1/16" (1.5) exterior vinyl trim strip set in continuous bead of sealant each side Andersen trim strip set in continuous bead of sealant each side 3/4" (19) Non-Reinforced Mullion Andersen LVL Reinforced Mullion 1-3/4" (44) 2" (51) 1- (35) Structure by others 2" support mullion wood filler 2" (51) 2" support mullion trim strip set in continuous bead of sealant each side 2" Support Mullion Joining Compatibilty Many units are designed to be joined with other Andersen units in a variety of non-reinforced and reinforced combinations. Other combination types and joining methods can be viewed in the Product Guide for Professionals, in Andersen Window Studio software, and by visiting andersenwindows.com. Combination designs should always be checked for design pressure performance requirements to ensure the appropriate joining method is specified. 9-10 A R C H I T E C T U R A L D E T A I L F I L E
Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) Installation flange at head and jambs retractable insect screen (2 panel door only) Remove installation flange at head and jambs (10) Unit Dim. Width (10) Unit Dim. Width oak or maple insect screen oak or maple metal sill support 3/4" (19) Wood Siding / 2 x 4 Wood Stud Framing Brick Veneer / 2 x 6" Metal Stud Framing Importance of Proper Installation Proper installation and maintenance of products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer. Construction by Others Andersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others. NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the perimeter of the window. NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange. A R C H I T E C T U R A L D E T A I L F I L E 9-11
Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) Installation flange at head and jambs auxiliary casing insect screen Membrane flashing over installation flange (by others) (10) (10) Unit Dim. Width Unit Dim. Width insect screen oak or maple oak or maple E.I.F.S. / Concrete Masonr y Unit (CMU) Brick / Concrete Masonry Unit (CMU) Importance of Proper Installation Proper installation and maintenance of products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer. Construction by Others Andersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others. NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the perimeter of the window. NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange. 9-12 A R C H I T E C T U R A L D E T A I L F I L E
Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) auxiliary casing 1-3/16" (30) Installation flange at head and jambs rigid vinyl 3/4" (19) "h" channel Installation flange at head and jambs Existing frame wall (10) Unit Dim. Width vinyl trim board (10) Unit Dim. Width insect screen oak or maple insect screen oak or maple metal sill support Stucco / Concrete Masonry Unit (CMU) Inset Door Existing Stud Wall Importance of Proper Installation Proper installation and maintenance of products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer. Construction by Others Andersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others. NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the perimeter of the window. NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange. A R C H I T E C T U R A L D E T A I L F I L E 9-13
Suggested Product Applications Wall Types Scale 1-1/2" = 1'-0" (1:8) rigid vinyl 3/4" (19) "h" channel Existing masonry wall Installation flange at head and jambs Vinyl Trim Board (10) Unit Dim. Width insect screen oak or maple Existing Masonr y Wall Importance of Proper Installation Proper installation and maintenance of products are essential if optimum performance is to be fully attained. Written installation instructions which provide guidelines for proper installation are available for Andersen products from your local Andersen supplier or by writing to: Andersen Windows, Inc., Box 12, Bayport, MN 55003 or by visiting our website at www.andersenwindows.com. Remember that every installation is different. Andersen strongly recommends consultation with an Andersen product representative and with an experienced contractor, architect, or structural engineer prior to the installation of any Andersen product. Installation of Andersen products, including method of attachment, fastener selection, and code compliance is the sole responsibility of the architect, building owner, contractor, and/or consumer. Construction by Others Andersen Corporation is not responsible for the design of, conditions in, or performance of, adjacent wall or roof construction beyond the perimeter of the Andersen units. Proper integration of the Andersen units with the weather-repellent system of the building is the responsibility of others. NOTE: Where E.I.F.S. wall finish is adjacent to units, contact E.I.F.S. manufacturer for installation instructions, including the use of appropriate flashing, the proper use of sealant and backer rod, and the proper width of sealant joint around the perimeter of the window. NOTE: Leave adequate clearance between sill and masonry for caulking and dimensional change of framework. Installation flange may be removed where construction sequence/ detailing requires no flange. 9-14 A R C H I T E C T U R A L D E T A I L F I L E