Harmonic Filters for Single Phase Equipment

Similar documents
Low Pass Harmonic Filters

Economical Solutions to Meet Harmonic Distortion Limits[4]

Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions

Effective Harmonic Mitigation with Active Filters

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Electromagnetic Harmonic Filters Technical Guide

POWER SYSTEMS QUALITY Topic 5: Principles for Controlling Harmonics

2.10. Adjustable Frequency Drives. Clean Power Drives. Clean Power Drives

Thyristorised Automatic Power Factor

THE COMPREHENSIVE APPROACH TO FACILITY POWER QUALITY

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

Owner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:

Harmonics White Paper

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

APPLICATION NOTE. Applying Type DD60 Capacitors in Harmonic Filter Applications. Total Power Factor PF = cosine ɸ

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

Dynamic Harmonic Mitigation and Power Factor Correction

General Description & Features Selection Charts Definition of Terms... 42

Understanding Harmonics

Effects of Harmonic Distortion I

How adjustable speed drives affect power distribution

PART 1 OWNER/APPLICANT INFORMATION

Harmonic Power. A VFDs.com Whitepaper Written by Ernesto Jimenez

NJWA - Harmonics and Drives Proper System Design

VARIABLE FREQUENCY DRIVE OPERATION AND APPLICATION OF VARIABLE FREQUENCY DRIVE (VFD) TECHNOLOGY

Understanding Input Harmonics and Techniques to Mitigate Them

ENERGY SAVING WITH OPTIMIZATION OF VOLTAGE AND CURRENT QUALITY

Understanding Harmonic Suppression Systems

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

Harmonic Distortion and Variable Frequency Drives

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Technical Paper. Harmonic Distortion in Data Centers

Power Quality Solutions

The power to work. Power conditioning products. Harmonic correction unit Sag ride-through power conditioner

PQ01. Harmonic Solutions for VFD s. Review of Power Control Harmonics, Power Factor, Distortion & Displacement

Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7

Drives 101 Lesson 5. Power Input Terminology for a VFD

Fundamentals of Power Quality

HARMONIC MITIGATIONCASE STUDY

Power Factor. Power Factor Correction.

Presents. Harmonics Years

LINEATOR. Advanced Universal Harmonic Filter

Guide to Harmonics. Reactive Power and Harmonic Compensation POWER QUALITY. The Basics of Harmonics

Advanced Harmonic Solutions For Harmonic Current Distortion MOTION CONTROLS

3/29/2012 MAIN TOPICS DISCUSSED ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K ELECTRIC RATES POWER COMPUTATION FORMULAS.

Alternating Current Power

VARIABLE FREQUENCY DRIVE

How Harmonics have led to 6 Power Factor Misconceptions

Alternator winding pitch and power system design

Section 11: Power Quality Considerations Bill Brown, P.E., Square D Engineering Services

Load Isolation Transformers

POWER CORPORATION. Power Quality. Specifications and Guidelines for Customers. Phone: Fax:

An easy-to-use Precision Power Analyser. The touch of a button gives direct readout of true power and a host of other useful measurements.

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

Reducing Total Harmonic Distortion with Variable Frequency Drives

Review of Electrical Noise on 120/240 volt Power Systems. Dec 12,

McGill Power Sales & Engineering, INC.

Open-Delta Systems Affect Variable Frequency Drives

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

BUFFALO ENERGY SCIENCE AND TECHNOLOGY GROUP

SWF DV/DT Solutions Sinewave Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

PowerMonitor 5000 Family Advanced Metering Functionality

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

World Academy of Science, Engineering and Technology International Journal of Electrical and Computer Engineering Vol:7, No:6, 2013

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

Dry Type Distribution Transformers NON-LINEAR TRANSFORMER PRESENTATION

CASE STUDY. Implementation of Active Harmonic Filters at Ford Motor Company SA Silverton Plant

Welcome to the rd. Annual Northern Ohio. 3 rd Energy Management Conference September 30, 2008

Power Quality. Answering Today s Power Challenges. Why Your Existing Transformer May Be Inadequate. How Harmonics Affect Transformers

BALLAST HANDBOOK. Basic Reference Manual. Integral Ballast Characteristics and Performance Data High Pressure Sodium Metal Halide HL-301 5/03

Harmonic Design Considerations for Wind Farms

Control of Power Converters for Distributed Generation

Harmonics I Harmonics White Paper. Power Protection Products, Inc. by Dan Maxcy l 2018 Update

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Strategies for design 600V large modular UPS for critical power applications

Introduction to Harmonics and Power Quality

APPLICATION FOR INTERCONNECTION & OPERATIONS OF MEMBER-OWNED GENERATION

HARMONICS CAUSES AND EFFECTS

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

Electric Power Quality: Voltage Sags Momentary Interruptions

Harmonic Mitigating Transformer - Technical Guide

ECET Modern Power

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

CHAPTER 4 PV-UPQC BASED HARMONICS REDUCTION IN POWER DISTRIBUTION SYSTEMS

APPLICATION GUIDE. Harmonics in HVAC applications

POWER QUALITY SPECIFICATIONS AND GUIDELINES FOR CUSTOMERS ENGINEERING STANDARDS CITY OF LETHBRIDGE ELECTRIC

Electromagnetic Harmonic Filters Technical Guide

Challenges of Parallel Operations

Unit 29 Three-Phase Transformers

GE Energy. Matrix Harmonic Filter Series D

Non-Linear Load Transformers

1C.4.1 Harmonic Distortion

Principles for Controlling Harmonics

Sizing the neutral wire cross-section and minimization of neutral currents using microgeneration in low voltage networks

Any wave shape can be reproduced by the sum of sine waves of the appropriate magnitude and frequency.

Tuningintobetter power quality

Harmonic Distortion Evaluations

Power Factor & Harmonics

PowerGard Series C 18-Pulse Enclosed Drive Controllers

Transcription:

POWER QUALITY Harmonic Filters for Single Phase Equipment Agriculture Call Centers Casino Slot Machines Computer Centers Distributed Generation Electronic Power Converter Oil & Gas On-Line UPS Power Electronics Equipment Lighting Variable Speed Motor Drives Water Pumping Wind Turbines

POWER QUALITY What is Harmonic Distortion? Harmonic distortion is the continuous deformation of the voltage or current waveforms and is generally caused by equipment that converts AC to DC, namely power electronics equipment. Harmonics are caused by common commercial and industrial loads such as: AC and DC motor drives, Motor soft starters, Welders, Computers, Slot machines UPS systems, Robotics, and Other power electronic loads. AC to DC rectifiers do not draw current from the power source as a continuous sine wave, but rather in short, rapid bursts. These (non-linear) loads draw what appears to be a chopped up current waveform through the electrical system all the way back to the power source (transformer, utility system, generator). As more and more power electronics loads are added to the electrical system, the magnitude of harmonic distortion increases.. Because harmonics flow at frequencies higher than the normal 60hz, special harmonic analyzers are required to measure the magnitude of harmonic distortion. Total Harmonic Distortion (THD) is normally expressed as a percentage with respect to the value of fundamental current or voltage. Why are harmonics a problem? Harmonic distortion increases the total rms current that flows from a power source (transformer) to a load, and the harmonic currents flow at frequencies which are higher than the supply frequency. Problems caused by harmonics include: Increased heating of transformer and motors, Increased power losses, Failure of power factor capacitors, Distorted system voltage, Reduced transformer life, Increased motor heating, Increased energy demand from power sources. Arteche solves harmonics problems! Generally speaking, the best place to solve harmonics problems is as close to their point of generation as possible. The most common solutions for harmonic distortion tend to divert harmonic energy to an alternative path to keep it off the common power system and away from the power sources. By solving harmonics close to the load, all points upstream of the harmonic filter will benefit and experience a higher level of power quality. The electric utility system will benefit regardless where the filters are connected in a customer s facility, however, in order for the facility electrical system to benefit, harmonic filtering equipment must be applied close to the non-linear loads. Arteche offers a complete range of harmonic mitigating equipment. We can recommend the best solutions to meet your power quality goals.

POWER QUALITY Harmonics in Single Phase Systems Harmonic distortion from 1-phase power electronics equipment are typically worse than for 3-phase loads. Besides the higher total harmonic current distortion (THD-i), 1-phase systems also experience the cumulative effect of the 3rd, 9th and 15th harmonics on a shared neutral conductor (4-wire or 3-wire 120/240 systems). When harmonics flow on the neutral conductor; Neutral current increases Neutral to ground voltage increases at the load Fire hazard and liability increases NEC requires larger neutral conductors and K-factor transformers The 3 rd harmonic alone may be as high as 90% of the fundamental current. Since the neutral has no over current protection, this can lead to severe overheating and a dangerous situation. Excessive 3rd harmonic (180hz) current can cause equipment interference, reduction of useful equipment life and has been known to cause electrical fires. Arteche Offers Two Types of Single Phase Harmonic Filters Our Single Phase Harmonic Filters solve problems caused by 1-phase power electronics loads such as switch mode power supplies, motor drives and power converters. We offer two basic types of filters to solve a wide variety of applications: 3rd Harmonic Filters, Low Pass Harmonic Filters. Rather than absorb the unwanted harmonics at the distribution panel, switchboard or upstream supply transformer, our single phase harmonic filters can be applied right at the loads (single load or group of loads). Solving for harmonics near to the culprit loads reduces the burden on your upstream electrical system and keeps your facility electrical system cleaner, more efficient, more reliable and safer. 3 rd Harmonic Filters Our 3 rd Harmonic Filters are ideal for plug-in type electronic equipment such as personal computers, laptops, slot machines and other office equipment. To accommodate multiple loads, they can either be supplied with duplex receptacles, or field wiring terminals for direct wiring into the branch circuit. Not only does our 3rd Harmonic Filter reduce third harmonic current by as much as 80%, it also reduces the 5 th, 7 th and 9 th harmonics. 3 rd Harmonic Filters typically reduce the triplen (harmonics which are multiples of 3) harmonic currents flowing on the neutral to a fraction of the phase current. 3 rd Harmonic Filters are designed for use where shared neutrals are common, and where many single phase power electronics loads are present. They focus on removing most of the 3rd harmonic, which is considered the worst for single phase systems. Our 3rd Harmonic filters allow fundamental (50hz or 60hz) current to flow easily from the supply to the load, but insert very high impedance at the 3rd harmonic frequency, effectively blocking most of the 3rd harmonic current. 3rd Harmonic Filters can reduce 3rd harmonic currents by as much as 80 percent, while reducing some higher order harmonics but by 25% to 50%. Low Pass Harmonic Filters Arteche s single phase Low Pass Harmonic Filter is generally considered the most effective of all passive harmonic filters. Often they are used in medium and high power applications such as: Electronic motor drives, Uninterruptible power supplies (UPS), Wind turbine inverters Photovoltaic power converters Arteche Low Pass Harmonic Filters significantly reduce all frequencies of harmonic current, but allow the fundamental current to pass relatively unimpeded. While in 3-phase systems, our Low Pass Harmonic Filters achieve residual levels of total harmonic current distortion (THD-i) of 5% or less, the single phase version can achieve levels as low as 5% to 10% THD-i. The Low Pass Harmonic filter includes series impedance to protect the loads from transient over voltage, so no additional reactors are needed for motor drive applications.

3 rd Harmonic Filters Plug-In Style Filters Typical Applications Office Buildings Compute r Centers Schools & Universities Call centers Casinos Photo depicts plug-in style filter with optional transient voltage protection. The basic function of 3rd harmonic filters is to impede the flow of third harmonic current (180Hz for 60Hz systems) in a circuit with little to no attenuation of the fundamental frequency (60Hz) current. The filter combines inductors and capacitors in a way that offers nearly infinite impedance to the unwanted harmonic (3rd) frequency. Separate versions of the 3rd harmonic filters are available for either 60Hz or 50Hz systems. Easy to Select Plug-In style 3rd Harmonic Filters are supplied with one or more duplex receptacles, based on their maximum ampere rating. Select the correct filter based on the total connected load. The Plug-In style 3rd Harmonic Filter has internal over current protection. Consult factory if you need other ratings. 120V 60Hz - Selection Table (Amps) Number of Outlets 3 2 THF 60 0003 120 N1 5 4 THF 60 0005 120 N1 10 6 THF 60 0010 120 N1 15 8 THF 60 0015 120 N1 Typical Performance - 3rd Harmonic Filters 120 100 80 NO Filter With Filter 60 40 20 0 Fund 3 5 7 9 11 Harmonics The harmonic spectrum (left) illustrates the magnitudes of individual harmonic currents for single phase loads for two conditions - without a filter (often more than 100% THD-i) and with a 3rd harmonic filter (often < 30% THD-i). POWER QUALITY

3 rd Harmonic Filters Branch Circuit Rated Filters POWER QUALITY Typical Applications Photo (right) illustrates internal components for 20 amp branch circuit rated filter. Includes terminal block for easy in-circuit wiring. Filter is suitable for single or multiple loads up to its maximum current rating. Office Buildings Computer Centers Schools & Universities Call centers Casino slot machines Lighting circuits Easy to select Branch Circuit Rated 3rd Harmonic Filters may be selected based on the current rating of the nearest upstream branch circuit protective device. This filter does not include internal fuses and therefore requires coordinated upstream over current protection. Consult factory if you need other ratings. 120V 60Hz - Selection Table (Amps) 20 THF 60 0020 120 N1 30 THF 60 0030 120 N1 40 THF 60 0040 120 N1 50 THF 60 0050 120 N1 60 THF 60 0060 120 N1 100 THF 60 0100 120 N1 The basic function of 3rd harmonic filters is to impede the flow of third harmonic current (180Hz for 60Hz systems) in a circuit with little to no attenuation of the fundamental frequency (60Hz) current. The filter combines inductors and capacitors in a way that offers nearly infinite impedance to the unwanted harmonic (3rd) frequency. Separate versions of the 3rd harmonic filters are available for either 60Hz or 50Hz systems. The harmonic spectrum at the illustrates the typical magnitudes of individual harmonic currents for single phase loads for two conditions - without a filter (often more than 100% THD-i) and with a 3rd harmonic filter (often < 30% THD-i). Typical Performance - 3rd Harmonic Filters 120 100 80 NO Filter With Filter 60 40 20 0 Fund 3 5 7 9 11 Harmonics

POWER QUALITY Low Pass Harmonic Filters For Distributed Generation Power Sources Single-Phase This unique version of our single phase Low Pass Harmonic Filter is specially designed for Distributed Generation (D-G) applications where an inverter is used as a power source to feed both linear and nonlinear loads. This filter serves as a buffer between the power source and the utility grid or between the power source and the loads and will typically enable the D-G equipment to comply with electric utility interconnect standards such as IEEE-1547. A front mounted D-G Interconnect Relay is available as an option for those applications where demanded by the local electric utility. Benefits of Arteche D-G Harmonic Filters Filter harmonics Absorb transients Reduce KVA burden on D-G power sources Photo illustrates single phase D-G harmonic filter in Nema 1 enclosure and with optional electric utility inter-connect relay. Consult factory for other ratings. Typical Applications Wind Turbines Photovoltaic systems Micro Turbines Fuel Cells Generators UPS inverter output Optional Features: Interconnect relay Capacitor cutout contactor Current sensing relay Various enclosure styles Selection is easy! Make the proper selection by determining the single phase line to line voltage and the load rating (KW, KVA, HP) of the D-G system. 240V 60Hz - Selection Table ( KVA ) 5 DGF 0005 216 N3R 7.5 DGF 007.5 216 N3R 10 DGF 0010 216 N3R 15 DGF 0015 216 N3R 20 DGF 0020 216 N3R 25 DGF 0025 216 N3R 30 DGF 0030 216 N3R 480V 60Hz - Selection Table ( KVA ) 5 DGF 0005 416 N3R 7.5 DGF 007.5 416 N3R 10 DGF 0010 416 N3R 15 DGF 0015 416 N3R 20 DGF 0020 416 N3R 25 DGF 0025 416 N3R 30 DGF 0030 416 N3R

Low Pass Harmonic Filters For motor drives, UPS input, pumps Single-Phase POWER QUALITY Selection is easy! Make the proper selection by determining the single phase line to line voltage and the maximum rating (HP) of the connected load. 240V 60Hz - Selection Table 480V 60Hz - Selection Table ( KVA ) ( KVA ) 5 LPF 0005 216 N3R 7.5 LPF 007.5 216 N3R 10 LPF 0010 216 N3R 15 LPF 0015 216 N3R 20 LPF 0020 216 N3R 25 LPF 0025 216 N3R 30 LPF 0030 216 N3R 5 LPF 0005 416 N3R 7.5 LPF 007.5 416 N3R 10 LPF 0010 416 N3R 15 LPF 0015 416 N3R 20 LPF 0020 416 N3R 25 LPF 0025 416 N3R 30 LPF 0030 416 N3R Without Filter Input Current Waveform Current Wave Form Amps 40 30 20 10 0-10 -20-30 -40 12:44:59.83 12:44:59.84 12:44:59.85 12:44:59.86 12:44:59.87 12:44:59.88 CHA Amps With Filter Input Current Waveform Current Wave Form Amps 75-75 10:47:59.85 10:47:59.87 10:47:59.89 10:47:59.84 10:47:59.86 10:47:59.88 10:47:59.90 CHA Amps 50 25 0-25 -50 Typical Applications Agricultural Recreational water Dairy farm Residential water pumps Methane wells Motor drives/inverters Arteche Low Pass Harmonic Filters reduce harmonic distortion to such low levels that the input current waveform is returned nearly to a perfect sine wave. The residual amount of input harmonic current distortion can be reduced to as low as 5% THD-I to 10% THD-i. Consult factory for other ratings. Photo shows internal components of single phase low pass harmonic filter.

We can solve all of your Power Factor Correction and Harmonic Distortion problems! Analysis Engineering Products Low Voltage Medium Voltage High Voltage POWER QUALITY Arteche PQ, Inc. 16964 W. Victor Road New Berlin, WI 53151 Phone: 1-262-754-3993 Fax: 1-262-754-3883 www.artechepq.com