REE series digital interpolators

Similar documents
RGH25F encoder system

rotary encoder system

TONiC DOP (dual output) encoder system

DSi dual readhead rotary encoder system

QUANTiC series encoder system

RGH24 encoder system. Data sheet L C. RGH24 readhead: RGS20 scale:

RGH45 encoder system. Data sheet L A. Uses RTLR40 and RTLR40-S highaccuracy. steel tape scale. Unique filtering optics and DC light servo

QUANTiC series encoder system

RGH34 encoder system. Data sheet L A. RGH34 readhead and RGI34 interface: RGS40 scale:

RGH22 encoder system. Data sheet L B. RGH22 readhead. RGS20 scale

RGH41 encoder system. The Renishaw RGH41 series is a non-contact optical encoder system, providing highly-reliable positional feedback.

TONiC encoder system. Data sheet L C

TONiC DOP (dual output) encoder system

Installation guide M A. RGH20 RSLR linear encoder system

TONiC encoder system. Data sheet L B

Installation guide M A. RGH20 RESR angle encoder system

TONiC UHV encoder system

EVOLUTE absolute optical encoder with Yaskawa serial communications

Installation guide M A. RGH34 RGS40 linear encoder system

Installation guide M C

Functional safety supplement L B. SiGNUM angle and linear analogue encoder systems

VIONiC series encoder system

Installation guide M B. RGH22 RGS20 linear encoder system

absolute optical encoder for Panasonic serial communications

Installation guide M B. VIONiC RSLM20 / RELM20 high accuracy linear encoder system

Installation guide M B. RGH40 RESR40 angle encoder system

Installation guide M B. RSU10 USB interface

Installation guide M D. VIONiC RSLM / RELM high accuracy linear encoder system

Installation guide M C

RELM20 high accuracy linear scale

RESOLUTE ETR (Extended Temperature Range) absolute encoder

Installation and user s guide H A. NCi-5 non-contact tool setting interface

RESOLUTE FS absolute optical encoder with Siemens DRIVE-CLiQ serial communications

Laser scale axis referencing with controllers with low bandwidth sine and cosine inputs

EVOLUTE RTLA50-S absolute linear encoder system

RESOLUTE absolute optical encoder with Siemens DRIVE-CLiQ serial communications

RTLC20 high accuracy incremental linear scale

RELA absolute high accuracy Invar scale

RTLA50 absolute linear encoder scale system for EVOLUTE

Installation guide M D. QUANTiC. linear encoder system. accuracy linear encoder

RM22 rotary magnetic modular encoder

RSLA absolute high accuracy stainless steel scale

RM36 series non-contact rotary encoders

RESOLUTE UHV absolute optical encoder

Application and installation addendum - high power optical system

Veratus Series Encoders

RTLA high accuracy absolute linear encoder scale system

RE22 series rotary encoders

RE36 rotary magnetic shaft encoders

LMA10 absolute magnetic encoder system

RM36. Rotation sensors RM36 Absolute rotary encoder

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

LMA10 absolute magnetic encoder system

Motor Encoders. With Motor encoders Series M - Optimal control of motor feedback -

Retrofit desk assembly instructions

Absolute Encoders - Singleturn

LM13 magnetic ring encoder system

DS Absolute Position, Rotary Electric Encoder

RM08 super small non-contact rotary encoder

Low Profile. 3 Year Warranty

Agilent AEDA-3300 Series Ultra Miniature, High Resolution Incremental Kit Encoders Data Sheet

QR12. Output. A = Line Driver B = Line Driver ABZ/ Open Collector UVW C = Sin/Cos/ Line Driver UVW D = Sin/Cos/Open Collector UVW

Speed and Key Monitor Specifications

Rotational Absolute Magnetic Kit Encoder Version 33 LP and HP Displacement Sensor

Absolute Encoders Multiturn

Absolute Encoders - Singleturn

PEOPLE IN CONTROL OF MOTION

Absolute encoders - SSI

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Rotary Measurement Technology Absolute Encoders, Multiturn

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders 18 bit ST / 12 bit MT

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

Absolute encoders - SSI Solid shaft with clamping or synchro flange Optical multiturn encoders up to 14 bit ST / 16 bit MT

Shaft Absolute Vibration Monitor Specifications

IF30. User's manual. Description. Table of contents IF30

LM13 linear magnetic encoder system

EY-EM 527: Remote I/O module, ecolink527

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.

Digital Fiber-Optic Switches

JR12 Jam Nut Mount Optical Encoder

Multifunctional counter tico 772/773/774

Rotary Encoder System Compact Model Range

UniStream Uni-I/O Modules

LENORD. +BAUER... automates motion. MiniCoder GEL 2444K Speed and position sensor with metal housing and sin/cos output

Model 140 Inline Amplifier

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Online data sheet AFS60E-S1AA AFS/AFM60 SSI ABSOLUTE ENCODERS

RM08 super small non-contact rotary encoder

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

UniStream Uni-I/O Modules

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

CMM cable listings and pin out diagrams

Absolute Encoders Singleturn

Online data sheet AFS60A-BJPA AFS/AFM60 SSI ABSOLUTE ENCODERS

LMA10 absolute magnetic encoder system

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

WSE22 - Magnetic shaft encoder

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

UCC AI installation guide

Transcription:

Data sheet L-957-939-0-B REE series digital interpolators The REE digital series of interpolators is designed to accompany the RG ( µm) and RG (0 µm) encoder systems by offering a wide range of interpolation factors. Industry standard Vpp differential input analogue signals are interpolated to industry standard RS-A digital quadrature output signals. These interpolators can be used with any standard Vpp differential output encoder system to enable easy integration with industry standard digital controller inputs. When interfaced with 0 µm pitch systems such as the RGH3, RGH0 and RGH, the interpolators give resolutions down to 0 nm. When used with µm pitch systems such as the RGH, RGH and RGH, the interpolators will resolve down to 5 nm. The REE interpolators are fully RoHS compliant and feature user selectable AGC (Auto Gain Control) that is operational at all speeds. These interpolators are capable of operational speeds of over 3 m/s at 00 nm resolution from a µm encoder signal period. The REE interpolators feature a tri-coloured setup LED indicating incremental signal strength. This allows ease of setup for optimum performance. A proportional external setup signal and calibration cycle also help to simplify installation. The REE interpolators have a low cyclic error less than 50 nm from µm signal period at low speed. This is achieved by active offset, balance and gain control which is operational, when selected, at all speeds. Using µm scale REE000-5 µm resolution REE00 - µm resolution REE000-0.5 µm resolution REE000-0. µm resolution REE00-0. µm resolution REE000-50 nm resolution REE000 - nm resolution REE00-0 nm resolution REE000-5 nm resolution Using 0 µm scale REE000-0 µm resolution REE00 - µm resolution REE000 - µm resolution REE000-0. µm resolution REE00-0. µm resolution REE000-0. µm resolution REE000-0 nm resolution REE00 - nm resolution REE000-0 nm resolution Tri-colour integral set-up LED Compatible with all standard Vpp analogue output readheads Industry standard RSA output Interpolation factors from x to x000 Binary interpolation factors from x to x096 available on request. User selectable automatic gain control (AGC) Low cyclic error Automatic offset and balance control (AOC and ABC) Clock speeds from to 50 MHz

Data sheet REE digital series interpolators REE installation drawing Optional mounting brackets (A-9539-8) Note: Remove washers when installing brackets Max. screw size M 7 00 Dimensions and tolerances in mm 0.35 Nm torque 9. 33.3 Input 5 way D type socket 6. Calibrate button Set up LED CAL /AGC LED Output 5 way D type plug Operating and electrical specifications Power supply 5V -5% +0% 30 ma current consumption (interface only). The interface will be fully active <300 ms after power is applied. Provision is given for remote sensing via two cores of the customers cable. NOTE: Current consumption figures refer to unterminated interfaces. A further 5 ma per channel pair (eg A+, A-) will be drawn when terminated with Ω. Renishaw encoder systems must be powered from a dc supply complying with the requirements for SELV of standard EN (IEC) 60950. The interface and readhead are protected from reverse voltage and overvoltage up to V. Ripple 0 mvpp maximum @ frequency up to 500 khz maximum Acceleration Operating 500 m/s² BS EN 60068--7:993 (IEC 68--7:983) Shock non-operating 000 m/s², 6 ms, ½ sine BS EN 60068--7:993 (IEC 68--7:987) Vibration operating 00 m/s² max @ 55 to 00 Hz BS EN 60068--6:996 (IEC 68--6:995) Temperature Storage - C to +70 C Operating 0 C to +55 C Humidity Storage 95% maximum relative humidity (non-condensing) Operating 80% maximum relative humidity (non-condensing) Sealing Mass IP0 95g EMC compliance BS EN 6000 BS EN 550 Connectors (input/output) 5-way D type socket/plug Maximum analogue input frequency (khz) Interpolation (option) x (000) x (00) x0 (000) x00 (000) 8. 3 56 Minimum recommended counter clock frequency (MHz) 5 0 0 6 5 5 8 6 65 0 8 5 90 35 5 6 0 50 Maximum cable length Interface to receiving electronics Recommended clock frequency (MHz) 5 Maximum cable length (m) 50 x0 (00). 3 0 5 67 8 35 6 x00 (000). 5.6 0 6 33 0 67 8 x000 (000) 0.8..5 6.5 8. 9 3 6 7 3 x00 (00) 0... 3..5 6.7 8. 3 6 x000 (000) 0. 0.5..6. 3. 6.7 8.

REE interpolator features Self-tuning active correction The REE interpolator corrects for input signal imperfections to optimise system accuracy. Corrections are made for the following: Automatic Offset Control (AOC) adjusts offset independently for the sine and cosine signals Automatic Gain Control (AGC) ensures consistent Vpp signal amplitude Automatic Balance Control (ABC) adjusts the gain to equalise the sine and cosine signals These correction mechanisms operate over the full working speed range of the readhead. The user can disable/enable the AGC by pressing the calibrate button for greater than 3 seconds. LED indicators The tri-coloured SETUP LED provides visual feedback of signal strength and error condition for setup and diagnostic use. Flashing Purple indicates high signal alarm condition >35% Purple indicates high signal >0% and <35% Blue indicates optimum signal >90% and <0% Green indicates acceptable signal >70% and <90% Orange indicates low signal >50% and <70% Red indicates unacceptable signal >% and <50% Flashing Red indicates unacceptable signal alarm condition <% Flashing Blue indicates overspeed alarm condition Flashes Off momentarily to indicate a reference mark, up to 00 mm/s only The Yellow CAL/AGC LED indicates when the REE is in a calibration routine and whether or not AGC is active LED on indicates AGC active LED off indicates AGC inactive LED slow flashing indicates calibration routine LED fast flashing indicates calibration failure Alarm output The REE interpolator asserts the alarm output (E) for the following conditions:- Incremental signal level below % of nominal Incremental signal level above 35% of nominal Readhead speed in excess of specification Signal offset compensation of sine and cosine excessive Signal balance compensation excessive Calibration procedure The calibration procedure is required to optimise the gain, balance and offset of the analogue input signals in the REF interface. These settings are then stored and recalled for initial use at startup. To calibrate the system, the following sequence should be carried out: } Prior to calibration, AGC should be off. To switch AGC on or off, the calibrate button should be pressed for more than 3 seconds. When AGC is on, the CAL/AGC LED will be on and when AGC is off, the CAL/AGC LED will be off. } Install the readhead and set up to obtain optimum ( Vpp) signal amplitude } Enter calibration routine by pressing the CALIBRATE button momentarily. The calibration routine is indicated by slow flashing of the CAL/AGC LED. } Traverse the readhead slowly past the scale until the CAL/AGC LED stops flashing. The calibration cycle is now complete. If calibration fails, the CAL/AGC LED will flash quickly instead of switching off. If this happens the CALIBRATE button should be pressed momentarily to exit the calibration routine. The calibration procedure should then be re-tried. If the unit continues to fail calibration, factory default settings should be restored by powering down, then pressing the CALIBRATE button as power is re-applied. The calibration procedure should then be repeated. NOTE: To exit the calibration routine at any time, the CALIBRATE button should be pressed momentarily.

Data sheet REE digital series interpolators Input signals REE interpolators are designed to be used with industry standard Vpp readheads. Cos (V ), Sin (V ) and reference mark (V 0 ) differential input signals should have nominal signal amplitude of Vpp developed across R input termination resistor. One or two open collector limit switch signals, active high or active low can also be input. 5 way D type socket Pin number Signal name Description V - Cosine -ve 3 V - V 0 + Sine -ve Reference mark +ve REE input power supply 5 power supply 6 Not connected 7 V x /V p Setup signal/second (P) limit switch on dual limit readheads 8 V q First (Q) limit switch 9 V + Cosine +ve 0 V + Sine +ve V 0 - Reference mark-ve power supply 3 power supply Do not connect 5 Inner Cable s inner shield connection to Output signals 5 way D type plug Pin number Signal name Description X External setup signal 3 E- power supply Alarm -ve REE output Z- Reference mark -ve 5 B- Quad B -ve 6 A- Quad A -ve 7 power supply 8 power supply 9 power supply 0 Q Q limit switch E+/P Alarm +ve/p limit switch Z+ Reference mark +ve 3 B+ Quad B +ve A+ Quad A +ve 5 Not connected

Output specifications Form - Square wave differential line driver to EIA RSA (except open collector limit and external set-up signal X) Incremental channels A and B in quadrature (90 phase shifted) Signal period Resolution Set-up A voltage at X B 0 0 signal level 00% * Reference Z * Wide reference (option C) Z Repeatability of position (uni-directional) is determined by the readhead specification. NOTE: The set-up LED on the REE interpolator cannot be used for reference mark set-up. Only the readhead LED (on Renishaw readheads) should be used for this purpose. NOTE: Wide reference mark option useful when using long cable lengths and/or high speed operation to overcome effects of skew *Limit RGH, RGH0 and RGH only Open collector output Single limit Q Length of actuating magnet Asynchronous pulse Q Termination P, Q to R # Repeatability <0. mm typical Synchronised pulse Z, duration as resolution Synchronised pulse Z, duration as signal period Dual limit P, Q Repeatability <0. mm typical Length of actuating magnet Asynchronous pulse P, Q # Select R so that the maximum current does not exceed ma. Alternatively use a relay or opto-isolator. Actuation device A-953-05, A-953-5, A-953-5. Setup signal voltage proportional to signal amplitude Alarm E Asynchronous pulse > ms NOTE: 3-state alarm option available Recommended signal termination REE A B Z E+ A B Z E- Cable Z 0 = R Standard RSA line receiver circuitry. #Only required on alarm channel E for fail safe operation. REE alarm asserted for: - Incremental signal <% of nominal - Incremental signal >35% of nominal - Readhead speed in excess of specification - Signal offset excessive *The presence of a reference mark and limit signal is dependent on the specification of the installed readhead. Inverse signal not shown for clarity k R k 5V 0V # # Customer electronics Electrical connections Grounding and shielding Vpp readhead Inner shield REE interpolator (if fitted) Extension cable Customer electronics power Output signals Outer shield Pin 5 Note: Extension cable inner shield must be connected to 0V at customer electronics only IMPORTANT: The outer shield should be connected to the machine earth (Field Ground). The inner shield should be connected to. Care should be taken to ensure that the inner and outer shields are insulated from each other. If the inner and outer shields are connected together, this will cause a short between and earth, which could cause electrical noise issues.

Renishaw plc New Mills, Wotton-under-Edge, Gloucestershire GL 8JR United Kingdom T + (0)53 55 F + (0)53 590 E uk@renishaw.com www.renishaw.com EMC compliance The REE interpolator conforms to the relevant harmonised European standards for electromagnetic compatibility as detailed below. BS EN 6000 BS EN 550 Patents Features of Renishaw s encoder systems and similar products are the subjects of the following patents and patent applications: US9595 US9796 US96566 EP038390 US50889 JP96396 EP038853 US5063685 JP83783 EP0508 US573 JP336 EP05353 US5308 JP58895 EP07836 US586953 EP8638B US60597 JP367689 EP0930 US685 US6588333 B EP7377 JP03-5,6 US67753 GB39700 CN585685 WO 03/0905 JP05-508,760 US05-007999 CN6353 WO 03/0689 EP69969 JP05-55,077 US05-005586 EP555 WO 0/008079 EP558 WO 0/008076 Further information For further information relating to the installation of REE systems, see also related readhead installation guides. These can be downloaded from our website www.renishaw.com/encoder and are also available from your local representative. This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means without the written prior permission of Renishaw. The publication of material within this document does not imply freedom from the patent rights of Renishaw plc. Disclaimer Considerable effort has been made to ensure that the contents of this document are free from inaccuracies and omissions. However, Renishaw makes no warranties with respect to the contents of this document and specifically disclaims any implied warranties. Renishaw reserves the right to make changes to this document and to the product described herein without obligation to notify any person of such changes. Interpolator part numbers REE 000 E 5 NOTE: Not all combinations are valid. Check valid options online at www.renishaw.com/epc A Options A - Dual limit switch B - Single limit switch C - Wide reference mark Clocked output 50-50 MHz customer clock 0-0 MHz customer clock 5-5 MHz customer clock - MHz customer clock - MHz customer clock 0-0 MHz customer clock 08-8 MHz customer clock 06-6 MHz customer clock 05-5 MHz customer clock 03-3 MHz customer clock 0 - MHz customer clock Alarms Standard alarm E A - All alarms B - High and low signal alarms only C - High and low signal, and overspeed alarms only 3 - state alarms E- All alarms F - High and low signal alarms only G - High and low signal, and overspeed alarms only Interpolation factor* 000 00 000 000 00 000 000 00 000 Interpolator series *Binary interpolation factors from x to x096 also available For worldwide contact details, please visit our main website at www.renishaw.com/contact RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS DOCUMENT IS CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY, HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT. RENISHAW and the probe emblem used in the RENISHAW logo are registered trademarks of Renishaw plc in the UK and other countries. apply innovation is a trademark of Renishaw plc. 07-08 Renishaw plc All rights reserved Issued 0808 *L-957-939-0*