Grid Radar Installation Manual

Similar documents
WATTNODE Pulse Output Installation and Operation Manual

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

PRODUCT SAFETY SOLUTIONS MODEL HWI-01. Model HWI-01 Serial Number:

User's Guide. Wireless AC Circuit Identifier. Models RT30 and RT32

User Guide. AC/DC Mini Clamp Meter. Model Introduction. Large 3 3/4 digit LCD display with 40 segment bargraph

Pen Multimeter. Model

MaxLite Linear Strip ECO Series

User s Guide. Model MA A AC Mini Clamp-on Meter

Series NRX with PXR - Instructions for Neutral Current Sensor Type NF

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

Pen Multimeter. Model

Preliminary Revised [ ] NOsparc User Manual. GGXAC1F480, GGXAC1F277, GGXAC1F240, and GGXAC1F120

Table of Contents. Safety Notices

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Radio Remote Controls Manual K Series

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

VT1586A Rack Mount Terminal Panel Installation and User s Manual

Important Safety Information

Broadband Step-Up Transformer. User Manual

Field Hub Installation Guide. P/N Rev. C 05/15

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

Smart-UPS On-Line Isolation and Step-Down Transformer SRT5KTF

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

Broadband Current Probe Series Operation Manual

QuadroMAX. Installation Manual. QM Series. LED Outdoor Lighting Fixtures REV: 3/22/16

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394

A1000 ALPHA and A1200 ALPHA Meter Installation Instructions. General. Installation. For A1000 ALPHA Type R, A1000 ALPHA Type C, and A1200 ALPHA Meters

Wireless Z-Wave Control ZRP-100US Z-Wave Repeater USER MANUAL. Introduction

How to install your ecobee Switch+

NOsparc User Manual IMPORTANT NOTES Arc Suppression Technologies. All rights reserved.

For detailed specifications and ordering info go to

BC145 SIGNAL ISOLATOR BOARD

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

Model 935A Current Source Operation Manual

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

200Amp AC Clamp Meter + NCV Model MA250

TA MHz oscilloscope probe TA MHz oscilloscope probe

AT Advanced Wire Tracer. Users Manual

Instruction Manual Inductive Gauging Sensor

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470

DIGITAL AUDIO AMPLIFIER WITH BLUETOOTH. Model: DAA User Manual

User s Guide FM Transmitter

80i-600A AC Current Probe

Wireless Transceiver (TRV)

500S Smart Antenna Installation and Operation Manual. P/N Rev. A 09/17 E29808

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

User s Guide Instructions for Installation and Operation

USER S MANUAL VAF POWER METER TRINITY. VAF Operational Manual

True RMS AC / DC Power Clamp Meter Model

600A Clamp Meters w/tightsight Display

WattNode Pulse and. Electric Power Meter - Installation Manual. Continental Control Systems LLC. WattNode Revenue. WattNode Pulse Models.

Broadband Current Probe Series Operation Manual

Smart-UPS RT. Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004.

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

2015 RIGOL TECHNOLOGIES, INC.

POWER TRACE TM TASCO, INC.

HDTV Antenna. Contemporary Indoor. User s Guide

Single Flex and Double Flex Couplings (i)

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

NEXUS NX50-1, -2 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION

User s Guide. 400A AC/DC Clamp Meter. Model MA220

ALPHA meter. General. Installation instructions IL S

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

PHASE ROTATION METER. Operating and Instruction Manual. a n d A C C E S S O R I E S

Circuit Breaker Finder

Radio Remote Controls Manual K Series

M2/M2A AC-DC Power Supply Operator s Manual

User s Manual. Ground Resistance Clamp On Tester MODEL

Acu-Park TM. user s guide Directed Electronics, Inc. Vista, CA N9100T 09-04

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

MaxLite LED Self-Driven LiteBars

Keysight Series 654xA, 655xA, 664xA, 665xA GPIB DC Power Supplies

T-L 810-T TRANSMITTER GUIDE

INTELLIMETER REGISTER

ELECTROSURGICAL UNIT ANALYZER

User Manual. Smart-UPS On-Line. Uninterruptible Power Supply. Isolation Transformer Models: SURT001 and SURT002

Model DB Disc Caliper Brake AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

NOsparc! MHXAC1F120! MHXAC1F240! MHXAC1F480 PATENTS AND PATENTS PENDING. Contact Arc Suppressor

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

SERVICE MANUAL. GPIB DC Power Supplies Agilent Series 654xA, 655xA, 664xA, 665xA. For instruments with Serial Numbers:

SIR-WRR1. User's Guide SIRIUS Echo Antenna. Signal Repeater System Accessory

INSTRUCTION LEAFLET IL17553B IQ UNIVERSAL POWER SENTINEL TM INSTALLATION INSTRUCTIONS FOR THE IQ UNIVERSAL POWER SENTINEL TM INTERNAL CT

BATTERY SENSOR. User Manual. Manual Version: BMS

HELLROARING TECHNOLOGIES, INC. P.O. BOX 1521 POLSON, MT

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

A-16D A-Net Distributor

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

DA560D COMPACT SERIES. INSTALLATION / OWNER'S MANUAL Mobile Power Amplifiers

AIS 300 Installation Instructions

Copyright Teletronics International, Inc. Patent Pending

Schooners II. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQSHR200 / AQSHR21

RFTX-1 Installation Manual

HTA125A/250A. Power Amplifiers. Installation & Use Manual

User's Manual. Model f/1f Power Clamp-on Meter

Transcription:

Grid Radar Installation Manual MODELS GN-RD-001 120V Single Phase / Wye, 240V Single Phase, with Neutral GN-RD-002 277V 3-Phase Wye, with Neutral GN-RD-003 480V 3-Phase Delta, no Neutral GN-RD-004 208V / 240V Single Phase, no Neutral Grid Navigator 200 Varick St. Suite 508 New York, NY 10014 www.gridnavigator.com support@gridnavigator.com 866 654 8007 1

SYMBOLS Read, understand, and follow all instructions, including warnings and precautions before installing and using this product. Potential Shock Hazard from Dangerous High Voltage. PRECAUTIONS Only qualified personnel or licensed electricians should install the Grid Radar. Follow all applicable local and national electrical and safety codes. More than one disconnect switch may be required to de-energize the equipment before servicing. The terminal block screws are not insulated. Do not contact metal tools to the screw terminals if the circuit is energized. Verify that circuit voltages and currents are within the proper range for the Grid Radar model. Use only Grid Navigator supplied or recommended current transformers. Protect the line voltage conductors to the Grid Radar with fuses or circuit breakers (not needed for Neutral). Equipment must be disconnected from the hazardous live voltage before access. If the Grid Radar is not installed correctly, the safety protections may be impaired. 2

OVERVIEW Grid Navigator s Grid Radar device is a wireless three-phase sub-meter that accurately reports the energy consumption of a three-phase, or single phase load. The wireless feature allows easy installation and integration with Grid Navigator s HVAC and lighting systems. The Grid Radar includes current transformers that are factory calibrated to measure active energy over a wide range of current fluctuation with less than 1% error. The three-phase design allows system managers to measure the active, reactive, and apparent energy usage by monitoring each phase. When integrated with Grid Navigator s intelligent wireless control system, the Grid Radar provides facility managers with the critical information necessary to provide occupants comfort, to accurately program energy usage, and to ensure maximum energy savings. KEY FEATURES FEATURE Wireless Communication Digital Calibration Calibrated clamp-on current transformers 120VAC to 480VAC, Wye or Delta configurable Three phase system Simultaneous RMS calculation on six analog inputs: - 3 AC inputs - 3 current sensors LED Indicators BENEFIT Easy installation for new buildings or for retrofits. Wireless connection through Grid Navigator Bridge. Allows remote reporting and alerting. No wires to pull through walls or conduit. Accurate reporting with less than 1% error in active energy measurement over a wide current dynamic range. Radar package includes all parts required for a complete installation. Pre-testing ensures accuracy of the entire system. Suitable to a wide variety of HVAC, Lighting, or other installations. Supplies critical information by monitoring phase voltage from each phase to neutral: - Active energy - Reactive energy - Apparent energy Reports detailed system performance for: - Peak voltage and current detection - SAG line voltage detection - Reverse power detection (active and reactive) - Line period or frequency Displays status of the 3 voltage phases plus RF connection and RF activity. 3

ELECTRICAL SERVICE TYPES AND RADAR MODEL NUMBERS Electrical Service Type Line to Neutral (VAC) Line to Line (VAC) Radar Power Source Radar Model Number 1 Phase 2 Wire 120V with Neutral 108-132 n/a ØA and N GN-RD-001 1 Phase 3 Wire 120 / 240V with Neutral 108-132 216-264 ØA and N GN-RD-001 1 Phase 2 Wire 208V no Neutral n/a 187-229 ØA and ØB GN-RD-004 1 Phase 2 Wire 240V no Neutral n/a 216-264 ØA and ØB GN-RD-004 3 Phase 4 Wire Wye 120V with Neutral 108-132 187-229 ØA and N GN-RD-001 3 Phase 3 Wire Delta 208V no Neutral n/a 187-229 ØA and ØB GN-RD-004 3 Phase 4 Wire Wye 277V with Neutral 249-305 432-528 ØA and N GN-RD-002 3 Phase 3 Wire Delta 480V no Neutral n/a 432-528 ØA and ØB GN-RD-003 SPECIFICATIONS POWER Powered from Internal Power Supply connected to sensed line voltage. +/- 10% of nominal. 150mA max. OPERATING CONDITIONS -40 to +65 C 0% to 90% RH STORAGE CONDITIONS -40 TO +90 C RF INTERFACE 2.4GHz 802.15.4 +19dBm RF RANGE Up to 1000 ft. depending on architecture HOUSING Polycarbonate UL94-V0 UL508 Approved 5 LED INDICATORS 3-Phase Voltage Status, RF connection, RF activity DIMENSIONS 8.692" x 4.755" x 2.461 WEIGHT tbd INSTALLATION This device is to be installed by a qualified electrician, and must follow all applicable national and local regulations. This unit, and the associated current transformers, must be installed inside an electrical panel only, and will not be accessible during operation of the device. Use appropriate sheet metal screws, and mount the unit using the pre-drilled mounting flanges. Insure the device model number is appropriate for the intended installation with regard to the voltage and wye/delta configuration. Do not position the Grid Radar so as to make accessing the disconnect device difficult. The disconnecting device must be marked accordingly and easily reached. 4

CONNECTION Refer to the following diagrams for connecting the Grid Radar. 3-PHASE 4-WIRE WYE CONNECTION WITH NEUTRAL 3-PHASE 3-WIRE DELTA CONNECTION NO NEUTRAL 5

SINGLE PHASE 2-WIRE CONNECTION WITH NEUTRAL SINGLE PHASE 3-WIRE CONNECTION WITH NEUTRAL 6

INTERNAL CONNECTORS J2, J3, and J4 are for Grid Navigator in-house testing purposes only, and are not to be used by the end user. Never attempt to connect anything to these connectors when the unit is powered. CURRENT TRANSFORMERS Only the supplied current transformers, or those recommended by Grid Navigator may be used. The current transformer must be rated for the desired measurement voltage, and the ratio must be such that no more than 0.2A is supplied to the Grid Radar input when measuring the maximum current. Supplied transformer(s): LEM TT 100-SD Maximum current: 100A Output current at 100A: 0.033A Isolation: 300V (Note: Insulated wire must be used above this voltage) For more detailed information on the supplied current transformer(s), please refer to the included factory data sheet. LED INDICATORS LED CONDITION DEFINITION ØA ØB ØC RF ACT. RF OK ON BLINKING ON BLINKING ON BLINKING BLINKING ON No Voltage present on Phase A Voltage present on Phase A and within specs Voltage present on Phase A but not within specs No Voltage present on Phase B Voltage present on Phase B and within specs Voltage present on Phase B but not within specs No Voltage present on Phase C Voltage present on Phase C and within specs Voltage present on Phase C but not within specs No RF activity RF activity No RF signal detected from Bridge RF signal detected from Bridge 7

MAINTENANCE AND REPAIR The Grid Radar requires no maintenance or field calibration. It is not user serviceable and there are no replacement parts except the pluggable screw terminals. There are no diagnostic tests that can be performed by the user. In the event of any failure, the unit must be returned to Grid Navigator for service. An RMA must be obtained from Grid Navigator before the unit is returned. The shipping information will be supplied by Grid Navigator with the RMA number. Contact information: support@gridnavigator.com or 866 654 8007 Mailing Address: Grid Navigator 200 Varick St. #508 New York, NY 10014 RISK ASSESSMENT Risk Analysis Risk of electrical shock Risk of damage to the unit Risk of power fail event Risk of Overvoltage Condition Risk of unit failure Risk Mitigation The Grid Radar is only to be installed by a qualified electrician or installer. The Grid Radar product is not user serviceable. If the unit is hooked up incorrectly it will not report the proper power data. The unit will not be harmed under this condition due to the product design. If the power fails the unit is no longer functional. When power is restored the unit returns to normal operation. The unit is protected by varistors and resettable fuses. A sustained overvoltage condition will require that the unit be returned to the factory for repair. Return to factory for repair, unit is not user serviceable Risk Other factors to mitigate risk User manual is detailed and provides necessary safety warnings. User Manual provides proper instructions for correct installation. Robust product design ensures that the unit will return to normal operation when power has been restored to the unit. Product is designed to handle temporary overvoltage conditions. Factory serviceable only. Factory serviceable only. 8

FCC ID: W7OMRF24J40MDME The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARRANTY All products sold by GRID NAVIGATOR are guaranteed against defects in material and workmanship for a period of one year from the date of shipment. GRID NAVIGATOR responsibility is limited to repair, replacement, or refund, any of which may be selected by GRID NAVIGATOR at its sole discretion. GRID NAVIGATOR reserves the right to substitute functionally equivalent new or serviceable used parts. This warranty covers only defects arising under normal use and does not include malfunctions or failures resulting from: misuse, neglect, improper application, improper installation, water damage, acts of nature, lightning, or repairs by anyone other than GRID NAVIGATOR. Except as set forth herein, GRID NAVIGATOR makes no warranties, expressed or implied, and GRID NAVIGATOR disclaims and negates all other warranties, including without limitation, implied warranties of merchantability and fitness for a particular purpose. Some states or jurisdictions do not allow limitations on implied warranties, so these limitations may not apply to you. Limitation of Liability: In no event shall GRID NAVIGATOR be liable for any indirect, special, incidental, or consequential damages. Some states or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. 9