AMERICAN NATIONAL STANDARD

Similar documents
Iam sure everyone would agree that the standards

American National Standard

American National Standard for Electric Power Systems and Equipment Voltage Ratings (60 Hertz)

ISO 5-3 INTERNATIONAL STANDARD. Photography and graphic technology Density measurements Part 3: Spectral conditions

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Graphic technology Spectral measurement and colorimetric computation for graphic arts images

American National Standard. For Wet Process Porcelain Insulators Indoor Apparatus Type ANSI/NEMA C (R2002, R2012)

ISO 5-4 INTERNATIONAL STANDARD. Photography and graphic technology Density measurements Part 4: Geometric conditions for reflection density

Graphic technology Spectral measurement and colorimetric computation for graphic arts images

American National Standard For Roadway and Area Lighting Equipment Wireless Networked Lighting Controllers

ISO INTERNATIONAL STANDARD. Graphic technology Colour and transparency of printing ink sets for fourcolour

ISO 2471 INTERNATIONAL STANDARD. Paper and board Determination of opacity (paper backing) Diffuse reflectance method

This document is a preview generated by EVS

This document is a preview generated by EVS

American National Standard. Physical Aspects of Watthour Meters Safety Standard. ANSI C Revision of ANSI C

ANSI/IEC American National Standard for Environmentally Conscious Design for Electrical and Electronic Products

TOLERANCES AND CLEARANCES FOR COMMERCIAL HOLLOW METAL DOORS AND FRAMES

HMMA 841 TOLERANCES AND CLEARANCES FOR COMMERCIAL DOORS AND FRAMES HOLLOW METAL -07 MANUAL AMERICAN NATIONAL STANDARD ANSI/ NAAMM METAL DOORS & FRAMES

ISO 5-2 INTERNATIONAL STANDARD. Photography and graphic technology Density measurements Part 2: Geometric conditions for transmittance density

ISO/IEC INTERNATIONAL STANDARD. Information technology Automatic identification and data capture techniques Bar code master test specifications

ISO 5-2 INTERNATIONAL STANDARD. Photography and graphic technology Density measurements Part 2: Geometric conditions for transmittance density

DENSITOMETRY. By Awadhoot Shendye

American National Standard. For Electric Connectors Non-Sealed, Multiport Connector Systems Rated 600 Volts or Less for Aluminum and Copper Conductors

ISO CIE S 014-2/E

Graphic technology Colour and transparency of printing ink sets for four-colour printing. Part 1:

Part 6: Flexographic printing

ISO/IEC TS TECHNICAL SPECIFICATION

Spectro-Densitometers: Versatile Color Measurement Instruments for Printers

Running head: AN ANALYSIS OF ILLUMINANT METAMERISM FOR LITHOGRAPHIC SUBSTRATES AND TONE REPRODUCTION 1

T 519 om-96 SUGGESTED METHOD 1970 OFFICIAL STANDARD 1978 OFFICIAL TEST METHOD 1980 REVISED 1986 REVISED 1991 REVISED TAPPI

ISO/IEC TS TECHNICAL SPECIFICATION. Information technology Office equipment Test charts and methods for measuring monochrome printer resolution

ISO 5-2 INTERNATIONAL STANDARD. Photography Density measurements Part 2: Geometric conditions for transmission density

Graphic technology Process control for the production of halftone colour separations, proof and production prints. Part 2:

American National Standard for Portable Cells and Batteries Environmental

Calibration of reflectance standards for hemispherical geometry

INTERNATIONAL STANDARD

SURFACE VEHICLE STANDARD

Application Note (A11)

Graphic technology Prepress data exchange Preparation and visualization of RGB images to be used in RGB-based graphics arts workflows

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

Substrate Correction in ISO

ISO INTERNATIONAL STANDARD

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

Problems in Color Proofing from the Colorimetric Point of View

An Analysis of Illuminant Metamerism for Lithographic Substrates and Tone Reproduction

Measurement of reflection and retroreflection

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Photography Root mean square granularity of photographic films Method of measurement

CGATS RECOMMENDED INDUSTRY PRACTICE. Color characterization data set development Press run guidelines

This document is a preview generated by EVS

Imaging Photometer and Colorimeter

ISO 3664 INTERNATIONAL STANDARD. Graphic technology and photography Viewing conditions

ISO INTERNATIONAL STANDARD

ST-53-X-ISO Dynamic Range Film Target Product Specifications

Progressing Cavity Pump Systems for Artificial Lift Surface-drive Systems

ISO INTERNATIONAL STANDARD

This document is a preview generated by EVS

This document is a preview generated by EVS

IAPMO IGC a Crimp-Style Metal Insert Fittings for SDR 9 PEX and PE-RT Tubing

ISO 3664 INTERNATIONAL STANDARD. Graphic technology and photography Viewing conditions

This document is a preview generated by EVS

Standard Test Method for Brightness of Pulp, Paper, and Paperboard (Directional Reflectance at 457 nm) 1

Predicting Color of Overprint Solid

Photography and graphic technology Extended colour encodings for digital image storage, manipulation and interchange. Part 4:

ISO 13655:2009 demystified

Diogen Lighting,Inc 14 Inverness Drive East,Ste.E-128 Englewood, CO T8L W BEST Test Service Shenzhen Co., Ltd.

Geometrical product specifications (GPS) Geometrical tolerancing Profile tolerancing

A Statistical analysis of the Printing Standards Audit (PSA) press sheet database

IESNA LM-79: Measurement and Test Report for Jiawei Technology (USA) Limited Lincoln Ave.Hayward, CA USA.

NEMA XR X-ray Equipment for Interventional Procedures User Quality Control Mode

E/ECE/324/Rev.1/Add.64/Rev.2/Amend.2 E/ECE/TRANS/505/Rev.1/Add.64/Rev.2/Amend.2

This document is a preview generated by EVS

Part 6: Flexographic printing

DRAFT EAST AFRICAN STANDARD

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

Idealliance ISO/PAS Certification Program Program Description v5 1. Introduction

Diffuse opacity of paper (d/0 paper backing) (Revision of T 519 om-02)

The World s Most Trusted Name In Color Quality. HunterLab

Optics and photonics Test methods for telescopic systems. Part 6: Test methods for veiling glare index

IGPG Car Wash Round Robin Test Procedure

ISO/TS TECHNICAL SPECIFICATION

OIML R 130 RECOMMENDATION. Edition 2001 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Octave-band and one-third-octave-band filters

Part 3: Image quality classes

NEMA Standards Publication ICS Adjustable Speed Electrical Power Drive Systems

EIA STANDARD TP-27B. Mechanical Shock (Specified Pulse) Test Procedure for Electrical Connectors EIA B ELECTRONIC INDUSTRIES ASSOCIATION

A Model of Visual Opacity for Translucent Colorants

Provläsningsexemplar / Preview TECHNICAL REPORT. Cables, cable assemblies and connectors Introduction to electromagnetic (EMC) screening measurements

Sýnishorn. Leather Tests for colour fastness Colour fastness to migration into polymeric material

Computer Generated Holograms for Testing Optical Elements

Disclosure to Promote the Right To Information

Band Class Specification for cdma2000 Spread Spectrum Systems

Keysight Technologies Optical Power Meter Head Special Calibrations. Brochure

Remote Director Version 2.6 with the Apple 20 LCD Display

ISO/PAS Graphic technology Printing from digital data across multiple technologies. Part 1: Principles

ETSI EN V1.1.2 ( ) Harmonized European Standard

Color Matching with ICC Profiles Take One

Viewing Environments for Cross-Media Image Comparisons

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

Guidance Note 7/17. Choosing the right photometer/illuminance meter

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

Transcription:

ANSI CGATS.5-2003 Supplement - 2005 AMERICAN NATIONAL STANDARD Graphic technology Graphic arts transmission densitometry Terminology, equations, image elements and procedures Supplement SECRETARIAT NPES THE ASSOCIATION FOR SUPPLIERS OF PRINTING, PUBLISHING AND CONVERTING TECHNOLOGIES APPROVED NOVEMBER 29, 2005 AMERICAN NATIONAL STANDARDS INSTITUTE, INC. CGATS 899 PRESTON WHITE DRIVE RESTON, VIRGINIA 209-4367 TEL: 703/264-7200 FAX:703/620-0994 www.npes.org

AMERICAN NATIONAL STANDARD Approval of an American National Standard requires verification by ANSI that the requirement for due process, consensus, and other criteria for approval have been met by the standards developer. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made toward their resolution. The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. Requests for interpretations should be addressed to the secretariat whose name appears on the title pate of this standard. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard periodically. Copyright 2005 by NPES The Association for Suppliers of Printing, Publishing and Converting Technologies All rights reserved. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher.

ANSI Supplement to CGATS.5-2003 Contents Foreword...iv Annex F (informative) Aperture size in reflectance measurements...v Annex G (informative)...vii NPES 2005 - All rights reserved iii

Supplement to CGATS.5-2003 ANSI Foreword This Supplement to CGATS.5-2005 corrects errors in Annex F (Table F.) and Annex G of that standard, and adds a new Informative Annex I that defines a method for correcting measured colorimetric data for differences in backing material. The Committee for Graphic Arts Technologies Standards (CGATS) was accredited by the American National Standards Institute in 989 to serve as the coordinator of graphic arts standards activities. CGATS identifies areas in which standards are needed and desired, respecting the established activities of existing accredited standards committees and industry standards developers. CGATS writes standards only where need exists and no other committee is undertaking the writing. This edition of CGATS.9 updates and replaces the 994 version of this document. It includes no substantial technical changes but has been reorganized to make the information more readily accessible and to bring some nomenclature into closer agreement with that used in ISO. CGATS recommends the voluntary implementation and use of this standard by all segments of the graphic arts industry. Requests for interpretation must be sent in writing to the CGATS Secretariat. This request will be forwarded to the appropriate committee, which will respond in writing. A statement, written or oral, that is not processed in accordance with the procedures noted above will not be considered the official position of CGATS, and should not be relied upon as a Formal Interpretation. Suggestions for improving this standard are welcomed. They should be sent to the CGATS Secretariat, NPES The Association for Suppliers of Printing, Publishing and Converting Technologies, 899 Preston White Drive, Reston, Virginia 209-4367, USA; Fax: 703-620-0994; E-mail: standards@npes.org. iv NPES 2005 - All rights reserved

ANSI Supplement to CGATS.5-2003 Annex F (informative) Aperture size in reflectance measurements Target elements on print control strips are seldom larger than 5 mm square and small spot 45/0 and 0/45 geometry spectrophotometers are available to read them. The small size of the targets and the small aperture required to read them requires special consideration of variations due to translucent blurring (lateral scattering) error. When a sample is translucent, some of the illuminating light penetrates the sample and scatters laterally to points outside of the area viewed by the instrument detector, causing the reported reflectance values to be lower than they would be if all the reflected light were collected. The interaction between the translucency of the sample and optical configuration of the instrument is called translucent blurring, and the difference in the reflectance factor measured on the translucent sample compared to the corrected reflectance factor is called translucent blurring error [7,23]. White glass reflectance standards and pressed powder pellets often used to calibrate large aperture spectrophotometers are generally translucent. Graphic arts proofing and printing substrates are translucent to some degree. To minimize translucent blurring error, large uniform samples are measured by illuminating a spot larger than the measurement aperture (over-illumination). ISO 5-4 requires that the "irradiated area of the specimen shall be greater than the sampling aperture, and its boundary shall lie at least 2 mm beyond the boundary of the sampling aperture." Based on the principle of optical reciprocity, equivalent measurements can be made with the viewing area larger than the irradiated area (over-collection). For targets 5 mm and smaller it is not practical to over-illuminate (or over-collect) with a 2 mm annular ring since the measurement aperture would be mm or less. For graphic arts applications it is recommended that the boundary of the irradiated area should be at least 0.5 mm outside the boundary of the sampling aperture. To minimize errors due to translucent blurring (light laterally spreading within the specimen beyond the limits of the aperture), it is important to use opaque calibration reference materials with low internal light scattering properties. This eliminates one source of translucent blurring error. Compared to white glass reference materials, targets on paper are relatively opaque and the use of black backing further reduces the scattering that causes translucent blurring error. Where the material being measured is translucent, it is desirable to have the illuminating beam significantly smaller or larger than the viewing beam. ASTM E 64 [5] specifies an annular ring approximately equal to the depth of penetration of the light into the specimen. This spreading within the specimen may occur as the result of coarse texture, translucency, or creped construction. Another factor that must be considered in the selection of instrument aperture when measuring halftone images is the relationship to screen ruling. Table F. shows the minimum recommended aperture size as a function of common screen rulings. NPES 2005 - All rights reserved v

Supplement to CGATS.5-2003 ANSI Table F. Minimum and recommended aperture size and sampling area Nominal screen frequency Round sampling aperture (mm) Non-round sampling area (mm 2 ) lines/inch lines/cm Minimum Recommended Minimum Recommended 65 26 3.8 5.7.3 25.5 85 33 3.0 4.5 7. 5.9 00 39 2.6 3.9 5.3.9 20 47 2. 3.2 3.5 7.8 33 52.9 2.9 2.8 6.4 50 59.7 2.6 2.3 5. 75 69.4 2..5 3.5 200 79.3 2.0.3 3.0 NOTE These sampling aperture sizes are valid for instruments that are not moving relative to the target and have a round aperture. For scanning instruments or instruments with apertures that are not round, the equivalent measurement area should be covered. Area can be achieved using either a single measurement, or by averaging multiple measurements in random or adjacent locations on the sample. This includes the use of scanning type instruments that make continuous measurements from a sample. vi NPES 2005 - All rights reserved

ANSI Supplement to CGATS.5-2003 Annex G (informative) Procedures for widening the bandwidth of narrow bandpass instruments This standard describes procedures for tristimulus integration of spectral measurements taken with either 0 nm or 20 nm bandwidth instruments. The ASTM method for tristimulus integration assumes that the instrument bandwidth and sampling interval are approximately equal (20 nm bandwidth implies a 20 nm sampling interval). A triangular response function with the half-power point equal to the bandwidth is also assumed. Some laboratory instruments make measurements with bandwidths that are smaller than this. To make use of the 0 or 20 nm spectral weights in the standard such data, collected at narrower intervals, it must be integrated to either 0 or 20 nm effective bandwidth. The technique that is used to create the desired data is to successively apply a triangular weighting function, which is based on the desired (new) sampling intervals and bandwidth, to the existing data. This weighted data is then summed over the appropriate interval and normalized by the sum of the weights used. This process is repeated for each new data point required. The triangular weighting function is a linear function that is at the wavelength of interest and 0 at a point that is equal to one desired bandwidth greater and less than the wavelength of interest. As an example, assume that data is available at 2 nm intervals and that data is desired at 0 nm intervals (and 0 nm bandwidth).. The calculation of the estimated value at 450 nm uses data from 440 to 460 nm (plus and minus one bandwidth). The data points for the available 2 nm data are at 440, 442, 444. 458, 460, 462, etc nm. 2. A proper triangular function for these conditions would then be points, the wavelength of interest (because it occurs in both the 2 nm and the desired 0 nm data) and 5 points (0 nm) on either side of the wavelength of interest. Since the slope of the triangle is linear, the weights will be 0.0, 0.2, 0.4, 0.6, 0.8,.0, 0.8, 0.6, 0.4, 0.2, 0.0. 3. Because the sum of the weights must be normalized to unity (.0), and the sum of the weights is 5, the resultant summation must be divided by 5. The calculation of the estimated reflectance (Rf) at 450 nm for a 0 nm bandwidth is therefore: Rf 0 (450) = [/5] [0.0 Rf 2 (440) + 0.2 Rf 2 (442) + 0.4 Rf 2 (444) + 0.6 Rf 2 (446) + 0.8 Rf 2 (448) +.0 Rf 2 (450) + 0.8 Rf 2 (452) + 0.6 Rf 2 (454) + 0.4 Rf 2 (456) + 0.2 Rf 2 (458) + 0.0 Rf 2 (460)] This process would be repeated at 0 nm intervals over the wavelength range of 360 nm to 780 nm. Similar procedures would be used for other bandwidth and sampling intervals. NPES 2005 - All rights reserved vii

Supplement to CGATS.5-2003 ANSI viii NPES 2005 - All rights reserved

ANSI Supplement to CGATS.5-2003 ANNEX I (informative) Correcting measured colorimetric data for differences in backing material I. Introduction The question of which backing to use when making spectral reflectance measurements has many answers depending on the application and perspective of those using the data. The densitometry standards all call for a black backing to minimize the impact of back printing and to minimize variability due to translucency effects and local variations in opacity and backing uniformity. The color management world finds more consistent results between visual comparisons of proof and print when using profiles based on white or self backing. The following methodology, referred to as the tristimulus correction method, is provided to convert colorimetric data of halftone samples measured over one backing to approximate that measured over another backing. The only input used is the tristimulus values of the substrate alone over the second backing. The tristimulus correction method is based on the observation that when the deltas in X, Y, and Z between measurements made over two backing materials (i.e. black and white) are plotted vs. the X, Y, and Z values for measurements made over either material the best fit result is approximately a straight line. At the lowest value of each tristimulus value, the delta between measurements made over the two backings is at or near zero. The maximum difference in measurement due to backing material characteristics is always at the maximum tristimulus value that equates to a measurement of the substrate (usually paper) alone; i.e., in an area containing no printing. I.2 Calculation procedure Measurements over one backing can be used to estimate the measurements that would be made over another backing by simply adding (or subtracting) a correction factor in X, Y, and Z. This correction factor is simply a proportional amount of the difference between measurements of the substrate alone over the two backings where the proportion added is defined by the value of X (or Y, or Z) on the first substrate compared to the minimum value of X and the value of X for the substrate alone. This leads to a correction equation for X as follows: X(n) 2 = X(n) + (X(s) 2 X(s) ) (X(n) * (X(s) X X MIN MIN ) ) where X (n) = Measured value of X for sample n over backing X (n) 2 = Predicted value of X for sample n over backing 2 X (s) = Measured value of X of the substrate over backing X (s) 2 = Measured value of X of the substrate over backing 2 NPES 2005 - All rights reserved ix

Supplement to CGATS.5-2003 ANSI X MIN = Minimum value of X which generally corresponds to a 4-color solid, which is patch ID 24 of the IT8.7/3 data set or patch ID 286 of the IT8.7/4 data set. For computation this equation can be rearranged as follows: where: X(n) 2 = (X(n) * (+ C )) C2 C = X(s) 2 X(s) X X(s) MIN and C = 2 C * Xmin Corrections for Y and Z of the individual samples are accomplished in a similar manner and CIE L*, a* and b* values are computed from the new tristimulus values. x NPES 2005 - All rights reserved