Fuse Finder 2 User Manual

Similar documents
2011 / Circuit Tracer

POWER TRACE TM TASCO, INC.

UR200SI / UR200WE ENGLISH

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

R9999 ROBERTS. PLL Synthesised 3 band radio with station name display. Sound for Generations. Please read this manual before use

TAG5000 WIRELESS PHASER. Instruction Manual HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS U.S.A.

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

Model: TP380 User Manual

PRECISION PIPE AND CABLE LOCATION. Instruction Manual Function Checker

Model: 5301P INSTALLATION AND OPERATION INSTRUCTIONS

Model: 5001 INSTALLATION AND OPERATING INSTRUCTIONS

User s Guide. Schooners II. Wireless 900MHz Speaker System. Schooners II 900MHz Wireless Speaker System Model: GDI-AQSHR200 /AQSHR21

A WORLD OF LISTENING WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE.

INDEX POWER SOURCES OPERATING ON BATTERY BATTERY REPLACEMENT

RD-21 ROBERTS. FM RDS/DAB digital radio. Sound for Generations. Please read this manual before use

PR-D5 中文 GB. Version 1

R9939 ROBERTS. PLL Synthesised 3 band mains battery radio. Sound for Generations. Please read this manual before use

SURETRACE CIRCUIT TRACER YOUR IDEAL TROUBLESHOOTING SOLUTION. DESIGNED TO FIND EVERYTHING, WHILE SAVING YOU TIME AND MONEY.

R PROFLAME Instruction Book Collection

PR-D9CL. GB Version 1

Cat. No. H8861 Model: RCL-S-STAT

CS-8000 Circuit Seeker. Circuit Tracer Rastreador de circuito Détecteur de circuit INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES MANUEL D INSTRUCTIONS

Pair of PMR446 Two-Way Personal Radios Model: TP391

GETTING STARTED. Radio layout. LCD display with icons

AT Advanced Wire Tracer. Users Manual

CHANCE Proximity Voltage Indicator

Cable I.D. Live. Primary or Secondary In or Out of the Trench TX-Former to TX-Former TX-Former to Meter Energized or Grounded.

DM 800H Twin Handheld UHF System (863.0Mhz-865.0Mhz)

ENVIRONMENTAL PROTECTION

Controls. LCD display A B C D E F

returned to your distributor for attention. 14. Do not operate the function switch while the instrument is connected to a circuit.

AT-4000 Advanced Tracer User s Manual

4. BASIC OPERATION AND DESCRIPTION

INFORMATION FOR YOUR SAFETY!

THANK YOU! Crush Micro PiX. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

Dawson DDM190. Digital Multimeter User s Manual

R9954 ROBERTS. 3 Band Mains Battery Portable Radio. Sound for Generations. Please read this manual before use

Operating Instructions

impact VC-500LR Monolight INSTRUCTIONS

Product Information and Instructional Presentation

POCKET READER AND POCKET READER EX. Operator s Manual

H201 中文 GB Version 1

3301 INSTALLATION AND OPERATING INSTRUCTIONS

Model 77 Series IV. Digital Multimeter. Users Manual

IMPORTANT SAFETY INSTRUCTIONS

OWNER S MANUAL FRS RADIO

SP980. Cordless Stereo 863MHZ. Speaker System. User s Manual INTRODUCTION FEATURES. Please read before using the equipment

Schooners II. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQSHR200 / AQSHR21

Important safety instructions

This manual applies to the WT-RC-Ex receiver when used to locate all makes and models of 22 Hz and Wavetrak coded transmitters.

Heritage MedCall. Sentry E-Call Model HM-527 Resident Host Panel

MultiMeter-Pocket CAT III 1000 V

SAFETY INFORMATION IMPORTANT FCC LICENSING INFORMATION

400Amp True RMS AC/DC Clamp Meter Model EX613

Always there to help you. Register your product and get support at AE2430. User manual

Pathfinder. Instruction Manual for: PF620 Circuit Tracer Kit

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Contents. Controls Stereo / Mono setting - FM Battery operation Scan sensitivity setting - FM Using the AC adaptor...

RCR-24 中文 GB. Version 1

Reaction Chromatic Tuner Instruction Manual

TW-82 TW-82 ACCESSORIES. Operating Manual Revision Level 1 DIGITAL LINE TRACER

TW-82. Operating Manual DIGITAL LINE TRACER. Revision Level 1

TOP SERVO SIGNAL 5 SERVO SIGNAL 3 SERVO SIGNAL 4 SERVO SIGNAL 6 T B T B T B T B T B SERVO TRIGGER 1 BOTTOM

STAFF User Manual. Manual Part #

TW-82 DIGITAL LINE TRACER. Operating Manual

HAWK5000 Operators Manual

INSTRUCTION MANUAL VHF FM TRANSCEIVER TK-7102H UHF FM TRANSCEIVER TK-8102H KENWOOD CORPORATION B (M)

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

DE1103 PLL FM STEREO/SW.MW.LW DUAL CONVERSION SYNTHESIZED WORLD RECEIVER OPERATION MANUAL

WIRELESS STEREO WOODEN PANEL SPEAKER SYSTEM

1410T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

a Loop System LA240 User manual ACCESS TO SOUND

Instruction Manual CXL Locator DXL Locator MXL Locator SGA Signal Generator SGV Signal Generator MXT Transmitter

PIN/PINLESS DEEP SENSING MOISTURE METER WITH SPHERICAL SENSOR AND REMOTE PROBE

Multi-Function Installation Tester MEGGER CM500. User Guide MEGGER

Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS

MEGGER CM300 MK II, CM400 MK II & CM500

C I R R U S EMERGENCY DESCRIPTION A. Emergency Locator Transmitter (ELT)

The Smallest, Quietest & Safest Garage Door Operator in the World!

CAUTION. RXM5010 Touchscreen Remote Installation and Operation Manual MODEL: RXM5010

AZATOM SONANCE T1 Digital Radio. DAB+/DAB/FM Radio Alarm Clock. User Manual. This manual is available to download online at

F I S H E R R E S E A R C H L A B O R A T O R Y

RU210. Dual Multi-UHF Wireless System. Item ref: UK, UK User Manual. Version 1.0

200Amp AC Clamp Meter + NCV Model MA250

400Amp True RMS AC Clamp Meter + NCV

TW-82 TW-82 ACCESSORIES. Operating Manual DIGITAL LINE TRACER F I S H E R R E S E A R C H L A B O R A T O R Y

79/26 Series III Multimeter

Current Clamp TP-CC80. User s manual. Rev. 1.1

Radio BMR100 INSTRUCTION MANUAL. ENGLISH (Original instructions)

Installation & User Manual Radio Remote RCS-10E

Compact MultiMeters + Voltage Detector

User s Guide. Rock Sounder Wireless 900MHz Outdoor Speaker System. Model: GDI-AQRCK400 / AQRCK41

OWNER S MANUAL FM HANDHELD TRANSCEIVER

R/C SMD Tweezers Multimeter Model RC200

TW Operating Manual F I S H E R R E S E A R C H L A B O R A T O R Y. Digital Line Tracer

Installation Manual REbus Beacon. Part of the Pika Energy Island M

RF (RADIO FREQUENCY) WIRELESS PENDANT

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

Transcription:

Fuse Finder 2 User Manual

1. Safety Warning The Kewtech Fuse Finder 2 is designed for use by suitably qualified personnel familiar with electrical supply systems. Before using your Fuse Finder 2 please read these instructions and safety warnings. Failure to comply with the safety warnings or use of the unit in a manner not specified by Kewtech may result in serious injury or damage to equipment. When testing at light fittings or bare wires, using a fused test lead set (not included): If at all possible switch off the power. Take care not to touch unshielded contacts when using the test lead adaptor. Connect RED or BROWN lead to live and BLACK or BLUE lead to neutral. 2. Battery installation The Fuse Finder 2 receiver is powered by a 9V Alkaline battery (not supplied) type PP3/MN 1604/6F22 or equivalent. To install a battery remove the screw (take care not to lose it!) and the battery compartment cover on the rear of the receiver enabling access to the battery compartment. Fit the 9V battery observing correct polarity. Replace the cover and screw. The transmitter is mains powered and does not require a battery. When fitted with a new battery and turned on the RCVR ON LED will be solidly lit GREEN. When the battery power becomes low the RCVR ON LED will flash. The battery will have approximately 20% of its capacity left at this stage and will shortly require replacement. When in use in this almost discharged state all of the signal strength LEDs will also flash rather than being solidly lit as they are with a fresh battery. Switch the power back on and test. USE EXTREME CAUTION. Only use in dry conditions (see specification section). Always prove that the transmitter and receiver are functioning before use (see pre-use check). IMPORTANT: Switch off your mobile phone when using Fuse Finder as its signal could intefere with the correct operation. www. www.

3. Principles of use The Kewtech Fuse Finder 2 enables the speedy identification of which breaker or fuse is protecting a circuit. The transmitter uses the mains supply to generate a modified high frequency signal into the live conductor that can be detected by the Fuse Finder receiver. The signal will not adversely affect other equipment but is powerful enough to work over cable runs of several hundred metres. The scanning head uses a ferrite transducer to detect the signal and when placed on breakers that are connected to the live supply under test will indicate the presence of the signal. To obtain the best results from your Fuse Finder 2 it is helpful to understand that the signal strength indicator is comparative rather than absolute. This means that each press of the ON/RESET button resets the sensitivity to maximum and the receiver will respond when placed in close proximity to any breaker or cable carrying the signal. During a test the receiver will auto tune its sensitivity to the strongest signal encountered since the reset button was last pushed. It is therefore necessary to ensure that all of the breakers that could be protecting a circuit are scanned at least twice and that you do not stop as soon as a maximum strength signal is indicated. 4. Switch functions Transmitter There is no switch for the transmitter. It will automatically start the injection of the test signal upon connection to a mains supply. Receiver The membrane switch on the receiver has 3 functions On/Reset/Off. Push and immediately release the switch when the receiver is off this will turn the unit on with a steady bleeping and green RCVR ON LED indicating that the scanning function is in progress. Push and immediately release the switch when the receiver is on this will reset all scanning function memories to zero, ready to start again, with a steady beeping and RCVR ON LED. Always use the reset function away from the distribution board so that no signal is present during reset. Push and hold switch down for over 1 second this will turn the receiver off. Note: To maximize battery life an auto-power off function is incorporated in the receiver which will turn the receiver off after three minutes of inactivity. To resume testing after this period just turn the unit on as described above. 5. Pre-use check Before each use of your Fuse Finder 2 you should prove that the unit is functioning correctly. To do this switch the receiver on and firstly check that the bottom LED is GREEN and a steady beeping tone is emitted. If either of these functions is not present replace the battery in the receiver before proceeding. Connect the transmitter to the mains and move the receiver scanning head over the face label of the transmitter. There will be hotspots on the transmitter label where the frequency of the beeping will become very rapid or change to a continuous tone and all 5 of the signal strength LEDs will light. If this indication can not be obtained the unit should be withdrawn from service and returned to Kewtech for examination.

6. Fuse finding process Plug the transmitter into the socket under test and switch the socket on. The red LED on the transmitter should light. Go to the consumer unit or fuse box. Turn on the receiver. A steady beeping tone will be emitted and the RCVR ON LED on the receiver will light GREEN to indicate automatic scanning mode. Place the scanning head in contact with the face of the circuit breakers or fuses at a right angle to the direction of the breaker body and run the scanning head steadily along the row(s) of circuit breakers. When the receiver detects a stronger signal the frequency of the beeping will increase to a very rapid or continuous tone, the pitch of the beeper will increase and the signal strength LEDs will light, climbing the bar graph. Ensure that you place the scanning tip on the circuit side rather than the supply side of the breaker switch. Important: Because the scanning technology used is comparative, on the first scan of the breakers or fuses on a board the MAX SIGNAL CORRECT FUSE FOUND LED will often light for several different breakers. This is indicating that the signal detected is the strongest found so far. Do not stop scanning at this point as it may not be the strongest signal there is. It is essential to continue scanning all of the breakers that may protect the outlet under test. Repeat the scan of the row of breakers without pressing the reset button. With each sweep the receiver will automatically adjust its sensitivity and disregard weaker signals. Continue scanning until the MAX SIGNAL CORRECT FUSE FOUND LED is lit only when the scanning head is over one breaker or fuse. This is the breaker protecting the circuit that the transmitter is plugged into. 7. Advice for best performance The scanning head uses a ferrite transducer to detect the signal and, like a portable radio, varying the angle at which the receiver is held in relation to the breaker will affect the strength of the signal received. As the receiver works by comparing the strength of signal received from one breaker with another it is essential to compare like with like. Observe the following for best results. Do not let the scanning head wander around. To operate well the automatic scanning memory needs a consistent signal so keep it in touch with the breakers as you scan and keep the position of the scanning head a similar distance from the breaker switch. Keep the black scanning head at the same angle relative to the breakers or fuses for the duration of the test. Due to the differing designs of circuit breakers it may sometimes be unclear from the above procedure which of two breakers the strongest signal comes from, particularly if the maximum strength signal appears to come from a boundary area between two adjacent breakers. In the event of this occurring one of the following variations should enable clear identification. a) Rotate the receiver (without resetting) through 360º to identify the orientation in which the strongest signal is found. Reset and re-scan the row of breakers. b) Reset the receiver and test at the opposite (to the common boundary) edge of each breaker. The strongest signal should come from the correct breaker. Turn the circuit in question off and the signal strength LEDs will extinguish leaving only the RCVR ON LED lit and a slow steady beeping tone. Confirm the correct breaker has been selected by checking that the red LED on the transmitter is no longer lit.

Kewtech Corporation Limited Midas House, Unit 2b, Stones Courtyard, High Street, Chesham, Bucks HP5 1DE T: 01494 792 212 F: 01494 791 826 E: sales@