The new Yaskawa Varispeed G7 Inverter

Similar documents
AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

Fan and Pump AC Inverter

ADJUSTABLE SPEED DRIVES. AS1 Drive

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

S11 Adjustable Speed Drive Engineering Specification

VF-nC1 Adjustable Speed Drive Engineering Specification

FUJI Inverter. Standard Specifications

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

Variable Frequency Drive / Inverter (0.4 ~ 280kW)

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

Manual Overview...1 2

E3 Adjustable Speed Drive Engineering Specification

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

6.9 Jump frequency - Avoiding frequency resonance

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

SX (400V) System configuration

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

General Specifications FECA-TE /2010. Phone: Fax: Web:

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

This Chapter contains:

PowerFlex 400 Submittal

Inverter Drive /Vector Drive Motors & Controls

SX (690 V) System configuration

ACH550 HVAC Drive Submittal

Operating Instructions

AF91 Adjustable Frequency Drives Series B

ADJUSTABLE SPEED DRIVES FS1

[ 4 ] Using pulse train input (F01 = 12)

Application Note. Applicable Product: AC Drives

SX (400 V) System configuration

NEWPCC VARIABLE FREQUENCY DRIVES Section LAB RENOVATION BID OPPORTUNITY NO PAGE 1 OF SCOPE

AF-300 G11 Specifications. GE Industrial Systems. Product Specifications AF-300 G11

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

SYSDRIVE 3G3FV Series

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

TOSVERT TM VF-nC3 Parameter List

Phoenix DX Clean Power (18 Pulse) AC Drive

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

A Subsidiary of Regal-Beloit Corporation. AC Inverter Terminology

EFC 3600 Frequency converter for higher energy efficiency and improved process control

Multi-function, Compact Inverters. 3G3MV Series

SJ700 series High performance with Many useful Functions and, yet User Friendly. WJ200 series Pursuing the Ideal Compact Inverter NEW

Medium Voltage VFD. Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV 600kVA ~ 11,000kVA

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

Softstarters. Specification guide. Type PST. Low Voltage Products & Systems

BOSTON GEAR CONTROLLERS. ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers. MTY (81)

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

CHAPTER 8 PARAMETER SUMMARY

Design Specifications Operator Keypad Environmental and Operating Conditions

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Frequency Inverters. SJ700B Series. Powerful Inverter for General Purpose Use. SJ700B Series

PowerFlex 400 AC Drive Guide Specification

G+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini

EN 50178, IEC

MV1000 MEDIUM VOLTAGE AC DRIVE 175 HP TO 16,000 HP

Intelligent Drive Systems, Worldwide Services SK 700E F 3070 GB

CTi Automation - Phone: Fax: Web: -

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

Frequency Converter Fv vector control converters for universal applications

Inverter MICROMASTER 410

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

WDG 61 - Technical Data Sheet

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

Before you operate the inverter, the parameters that you must first program are the basic parameters.

NX Series Inverters. HVAC Pocket Programming Guide

WDG 51 - Technical Data Sheet

HPVFP High Performance Full Function Vector Frequency Inverter

WJ200 series Pursuing the Ideal Compact Inverter

Variable frequency drives; 1-/3-phase 230 V; 10.5 A; 2.2 kw; EMC filters; braking transistor

AV-300i Specifications. GE Industrial Systems. Product Specifications. A New Concept in Automation. AV-300i

WDG 12 - Technical Data Sheet

WDG 12 - Technical Data Sheet

WDG 83 - Technical Data Sheet

Siemens OPERATING INSTRUCTIONS FOR MICROMASTER ECO & MIDIMASTER ECO V1.19. Variable speed drive for Fans and Pumps (HVAC) from 0,75kW to 315kW

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

General Purpose Drives

NX series Constant and variable torque Variable Speed Drives for induction motors

GS1 Parameter Summary Detailed Parameter Listings...4 9

Product description. At a glance. Customer benefits

Orbital GFI Inverter Series

Frequency converter. Frequency Converter Fe

INTER PLANT STANDARD STEEL INDUSTRY VARIABLE VOLTAGE VARIABLE FREQUENCY SYSTEM (V.V.V.F.) V/F, VECTOR CONTROL / TORQUE CONTROL

Frequently Asked Questions (FAQs) MV1000 Drive

WDG 12 - Technical Data Sheet

Micro and Mini Inverters

Meduim Voltage Drives

WDG 13 - Technical Data Sheet

vacon nx all in one application manual ac drives Phone: Fax: Web: -

WDG 07 - Technical Data Sheet

Caution. Three-phase 400V series FRN0.4C1S-4A FRN0.75C1S-4A FRN1.5C1S-4A FRN2.2C1S-4A FRN3.7C1S-4A

Transcription:

The new Yaskawa Varispeed G7 Inverter Unique new 3-level PWM flux vector Constant or variable torque applications control method 0.4 kw to 300 kw power range Exceptional low speed/high torque control Quick and easy installation Low electrical and acoustic noise Autotuning - static or dynamic Low surge voltage Fieldbus compatible Energy saving Technical Specifications Superb new performance features Yaskawa s unique new 3-level control method sets a new global standard for AC variable speed control Extended open-loop speed control range, increased from 100:1 to 200:1 Smooth stable performance at ultra low speeds Full control at zero speed Accurate torque control in open loop Fantastic control and protection features Low acoustic noise Low electrical noise (reduced RFI) Reduces electrolytic corrosion in motor bearings caused by motor shaft voltages Eliminates micro surge problems due to reflected voltage waves Leakage current greatly reduced Can be used on existing standard motors, without the use of output chokes for cable runs of upto 300m Low cost of ownership Easy to install and simple to use - language LCD display fitted as standard High efficiency Low maintenance Global certification Global availability and interchangeability Global certification - CE, UL, cul

Main Features of Varispeed G7 Inverter Feature 1: 3-level Control Technology 400V frequency inverter solution The first 400V frequency inverter with 3-level control technology are now available to approach sinusoidal output voltage. This technology helps to solve problems such as stressing of the insulation of motor windings by overvoltages (caused by travelling waves), and electrolytic corrosion of the bearings (caused by leakage currents via the motor shaft). It also considerably reduces motor acoustical noise and leakage currents (particularly with long motor cables). Advantages of 3 level control technology 1 Low voltage peaks Lower voltage peaks increase the life of the motor by reducing the stress on the insulation of the motor windings. They also make operation with long cables readily possible. 2 Low level of radio interference Considerably reduced conducted emission caused by the inverter reduces the cost of line filters. 2-level control (Conventional technology) 3 Quiet motor operation The 3-level technology drastically reduces the noise due to magnetic transients in the motor. 3-level control (new technology) Suppression effect VPN VPN 0 0 Phase voltage + level Phase voltage level level level level Line voltage Line voltage Feature 2: Ecologically friendly Effective energy saving function The energy-saving control approaches the maximum efficiency, High efficient, energy-saving operations are achieved for any applications either in vector or V/f control. Suppression of harmonic distortion All inverters larger than 15kW are equipped with a DC bus reactor and second rectifier bridge as standard. In combination with a transformer with two secondary windings (star and delta), the harmonics can be suppressed using the 12 pulse method. Mains current without suppression of harmonic distortion Mains current with 12 pulse method

Feature 3: Highly Dynamic and Precise Control Excellent torque characteristic The new dual flux observation method improves the torque characteristic (150% at 0.3Hz for open loop vector control 2). 150% torque is available at 0rpm with pulse Accurate torque control The precision of the limiting function allows accurate control of the output torque in order to protect machines and materials against sudden changes in load. generator feedback. High torque with a speed control range of 1:200 (after rotating autotuning in open loop vector mode) [speed control range with pulse generator feedback 1:1000] Extremely fast response The model tracking control assures fast response even without PG (doubled in in-house comparison). With a PG you can make use of our unique high speed current vector, rapidly responses speed reference changes (speed response 40 Hz/motor unit). Speed keeps constant even if load fluctuates. Torque control (torque limiting set to 150%) Very fast speed search function This function reduces the recovery time after momentary power loss. Recovery is possible regardless of the direction of rotation. Input voltage (400V/div) Frequency reference (30Hz/div) Speed (12Hz/div) Output frequency (12Hz/div) Output voltage reference(40v/div) Output current, phase U (25A/div) Fast response to changes in speed (reference speed step response) Handles sudden changes in load (speed characteristic with change in load) Simple method of autotuning Another method of autotuning, with the motor shaft stationary, is now available as an alternative to the established rotating technique. This allows the performance of any make of motor to be optimised. Fast, smooth start (power loss ridethrough) Reliable protective function Very fast and accurate current regulation functions support continuos operation by preventing overcurrent tripping. Power loss ridethrough, motor stall prevention and automatic restart after fault also support the uninterruptible operation. A motor thermistor can be evaluated using an analog input and protects the motor against overheating.

Feature 4: User friendly Easy to operate The 5 line, illuminated LCD display allows easy operation. The copy function provided by the removable operator makes it easy to copy a set of parameters from one inverter to another. The Quick Programming Mode makes start up easier. Parameters differing from the factory defaults can be read and altered by choosing Modified Constants from the menu. Easy maintenance and inspection The removable control terminal block allows the inverter to be replaced without disconnecting the control lines. The cooling fans can be changed without dismantling the inverter. The operating time of the inverter and individual fans can be recorded and displayed. A support tool using a PC is also available. All constants of inverter can be managed by a PC. Varispeed G7 Multi function I/O interfaces The analog inputs and outputs are supplemented with a pulse train input and a pulse train output. 10 digital multifunction inputs and 5 digital multifunction outputs are available. Positive or negative (NPN/PNP) logic can be chosen for the digital inputs.

Feature 5: Global Specification Support for global fieldbus standards All inverters support the Memobus/Modbus protocol via an RS422/485 interface as standard. Optional fieldbus cards can be fitted to allow the Varispeed G7 to communicate with host systems for central control of production with minimum wiring. Digital operator in seven languages The illuminated 5 line LCD display allows operation in 7 languages: German, English, French, Italian, Japanese, Portuguese and Spanish. Conformity with global standards for worldwide use Certified to UL/cUL and CE

Standard Specifications arispeed G7 Electrical Data 400V inverters Model CIMR-G7A 40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 Nominal Motor output in kw 0.55 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 185 220 300 Rated output in kva 1.4 2.6 3.7 4.7 6.9 11 16 21 26 32 40 50 61 74 98 130 150 180 210 250 280 340 460 Rated output current in A* 4 1.8 3.4 4.8 6.2 9 15 21 27 34 42 52 65 80 97 128 165 195 240 270 325 370 450 605 Max output voltage 3 phase 380 / 400 / 415 / 440 / 460 / 480V AC (proportional to input voltage) Max output frequency 400Hz Rated input voltage & frequency 3 phase 380 / 400 / 415 / 440 / 460 / 480V AC +10%, -15%, 50/60Hz ±5% DC bus reactor optional Provided 12 pulse input not available available (transformer necessary) Protective functions Control General Specification Control method Sinusoidal PWM with 3-level control (flux vector control with pulse generator feedback; open loop vector control 1 and 2 V/f control, V/f control with pulse generator feedback) Speed Response 10Hz (open loop vector control 2), 40Hz (vector control with PG) * 1 Speed Control Range 1:200 (open loop vector control 2) 1:1000 (flux vector control) Speed Control Accuracy ±0.2% (open loop vector control), ±0.02% (flux vector control) at 25 C ± 10 C Frequency Control Range 0.01 to 400Hz * 2 Frequency Accuracy Digital reference: ± 0.01%, -10 0 C to +40 0 C; Analog reference: ± 0.1%, 25 0 C ± 10 0 C Frequency Setting Resolution Digital reference: 0.01Hz; Analog reference: 0.03Hz/60Hz (11-bit + sign) Output Frequency Resolution 0.001 Hz Starting Torque 150% at 0.3Hz (open loop vector control 2) 150% at 0Hz (flux vector control with pulse generator feedback) Torque Response 20Hz (open loop vector control 2), 200Hz (vector control with PG) * 1 Torque Control Possible with open loop vector control 2 and flux vector control Overload Capacity 150% for 60 sec, 180% for 14 sec, 200% for 0.5 sec of the inverter rated current Accel/Decel Time 0.01 to 6000.0 sec (Accel/Decel time setting independently, 4 steps available) Braking Torque Approx. 20% (Approx. 125% when using braking resistor)* 3 Built-in braking transistor provided for inverters of 15kW or less Important Functions Power loss ridethrough, speed search, overtorque/undertorque detection, torque limits, 17 multi-step speed settings, 4 acceleration and deceleration times with ramp change, S-curve, autotuning (rotating and non-rotating), dwell function, cooling fan ON/OFF control, motor slip compensation, jump frequencies, High Slip Braking, energy saving function, PID controller (with sleep function), MEMOBUS communication (RS422/485), automatic restart after fault, copy function, droop control, torque control, changing between torque and speed control 2 switchable sets of motor parameters, etc Analog inputs 2 x -10 to 10V, 1 x 4-20mA, 1 x pulse train input (11 bit + sign) Analog outputs 2 x -10 to 10V, 1 x pulse train output Digital inputs 12 inputs (10 freely Programmable) Digital outputs 2 relay contacts, 4 open collector outputs (5 freely Pragrammable) RS422/485 Inbuilt, MEMOBUS protocol Digital operator Motor protection Overvoltage protection Undervoltage protection Earth fault Overheating protection Charging indicator Stall prevention 5 line LCD display with copy function Electronic thermal overload relay (PTC evaluation possible) Trips if the DC bus circuit voltage exceeds 820V Trips if the DC bus circuit voltage falls below 380V Protecting by electronic current monitoring Heat sink with thermistor monitoring Comes on if DC bus voltage exceeds 50V Stall prevention during acceleration and deceleration, and operation can be set seperately Braking transistor Upto 15kW standard, 18.5 to 300kW optional Ambient temperature 10 to +45ºC during operation (upto +60 0 C by deration) Relative humidity Maximum of 95% (non-condensing) Installation altitude Below 1000m (higher on request) Vibration 10 bis 20 Hz, 9.8m/s 2 max.; 20 to 50 Hz, 1.96 m/s 2 * 1 Specifications for open loop vector control and vector control with PG require dynamic auto-tuning. * 2 The maximum frequency is 60Hz for open-loop vector control 2. * 3 When using a braking resistor or braking resistor unit, set L3-04 = 0 (deceleration stall prevention). If not, motor may not stop at the set time. * 4 Current ratings declared at 45 0 C, Deration of 1.33% per degree above 45 0 C (Max upto 60 0 C)

DIMENSIONS (The Figure shows 400V class, inverters) Voltage Class (3-phase) kw 0.4 0.75 1.5 2.2 3.7 Dimensions in mm E nclosed Wall-mounted (NEMA 1) Open Chassis (IP00) W H D 140 280 Approx. Mass 157 3. 5 177 4. 5 Mounting Holes d* MS W H D Approx. Mass 5.5 7.5 200 300 197 7 11 240 350 207 10 15 M6 18.5 275 450 258 26 22 30 37 45 325 550 283 37 55 90 M10 450 725 348 75 91 90 109 500 850 358 110 127 132 165 575 916 378 160 M12 175 185 260 710 1305 413 220 280 300 916 1475 413 415 Mass in kg Sales Offices Mumbai New Delhi Chennai Kolkata Tel.: 022-28581191 Tel.: 011-51419521 Tel.: 044-28462050 Tel.: 033-22828418 Fax: 022-28581463 Fax: 011-51419600 Fax: 044-28462102 Fax: 033-22827587 Baroda Bangalore Hyderbad Jamshedpur Tel.: 0265-2341171 Tel.: 080-25020342 Tel.: 040-55720319 Tel.: 0657-2311872 Fax: 0265-2336184 Fax: 080-25583613 Fax: 040-23242356 Fax: 0657-2313881 Pune Durg Coimbatore Tel.: 020-4033409 Tel.: 0788-2322809 Tel.: 0422-2311872 Fax: 020-26124910 Fax: 0788-2210161 Fax: 0422-2313881 EBG - Control & Automation Business Unit Automation Systems Centre, TTC Electronic Zone, Shil Mahape Road, Navi Mumbai - 400 710 Tel: 91-22-55901401/27683511 Fax: 91-22-27611590 e-mail: cna-marcomm@asc.ltindia.com www.automation4me.com CNA-AC-G7-10/04 R2 Printed on 10/09/04