DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

Similar documents
DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DPS 100 DPS 100. Gauge- / Differential- / Absolute Pressure Transmitter

PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

TT2780. Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B, BUZ, BUZ-H

Submersible pressure sensor For oils and fuels Model LF-1

Flush pressure transmitter For viscous and solids-containing media Model S-11

ED701 General Industry Pressure Transmitter

Submersible pressure sensor For water and wastewater Model LW-1

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Pressure transmitter For general industrial applications Model A-10

OEM pressure transmitter For mobile working machines Model MH-3

Electronic temperature switch with display Model TSD-30

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Pressure transmitter For general industrial applications Model A-10

Submersible pressure sensor For superior applications Model LF-1

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Resistance thermometer Model TR30, compact design

TPFADA FLUSH DIAPHRAGM PRESSURE TRANSMITTER WITH DIGITAL AUTOZERO & SPAN

High-quality pressure transmitter For general industrial applications Model S-10

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

Resistance thermometer Model TR30, compact design

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

High-quality pressure transmitter For general industrial applications Model S-20

Materials (other materials see WIKA diaphragm seal program) Model S-10

Electronic Pressure Switch Type MEP

Pressure Transmitter SIL

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

ATM.ECO - Analog Pressure Transmitter with Temperature Compensation

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

NAT Applications. Features

NAT Applications. Features

Resistance thermometer Model TR31, miniature design

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Resistance thermometer Model TR30, compact design

Miniature resistance thermometer Model TR33, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Pressure transmitter AKS 32 and AKS 33

CTE7000 Series Miniature pressure transmitters

SALES SERVICE +358 (0)

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

CTE8000 Series OEM pressure transmitters for industrial media

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature Transmitters TMT 136, TMT 137

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital inductive conductivity transmitter

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

Relative and absolute pressure transmitter type 528

Features. Picture. Specifications. Pressure Transmitter 4-20mA 2-wire MPG Type: MPGxxxxxxxx for level measurement Order No.: see Table 1 / Page 4

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

SATRON VB Pressure Transmitter

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

U5300 Industrial Pressure Transducer

... for hydraulic and general applications in hazardous areas

DTM.OCS.S/N - Modbus Level Transmitter

Temperature Transmitter itemp RTD DIN rail TMT 127

Digital flow transmitter for continuous flow measurement

Operating Instructions

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Inductive sensor slot-type SI2-K08-AP7

Mechatronic pressure measurement. Applications. Special features. Description

Technical Data Measuring principle Thick-film-on-ceramic 25 C typ. ± 0.3 % FS typ. (± 0.5 % FS typ., ± 1 % FS typ.)

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

This kind of information is useful to make reliable automatic control diagnostic and supervision systems. IS VS. Diameter of cylindrical types

VTM Local Display Unit with Frequency and Analogue Output

Positioner with HART Communication Type 3780

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Inductive Standard Displacement Transducers

XPC10 High temperature miniature pressure sensor

Pressure transmitter For sanitary applications Model SA-11

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

Relative and absolute pressure transmitter type 528

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

Non-Submersible Industrial Pressure Transducer

KFS. Flap-type flow meter. Design and range of application

Screw-in resistance thermometers with plug connector

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

General Specification

Low Pressure NSL Applications. Features

ECT Applications. Features

Transcription:

GmbH Postal address: House address Fon (+49) 0 22 42-870-0 Postbox 26 Löhestr. 7 Fax (+49) 0 22 42-870-20 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de Data Sheet Page /5 Intelligent Electronic Pressure Switch Completely in Stainless Steel piezoresistive stainless steel sensor Description The electronic pressure switch is the successful combination of up to 2 independent contacts, configurable optional: - analogue output - Ex-protection (for 2-wire) nominal pressure range from 0... 00 mbar up to 0... 600 bar intelligent pressure switch digital display and is suitable for universal usage. As standard the offers a PNP contact and is optionally available with a second, independent contact. Additionally the device could be equipped with an analogue output, which has a turn-down-possibility of :6 for the -wire-version. The 2-wire version is also available with Ex-protection. So BD SENSORS is one of the few competitors on the world market offering intelligent, intrinsically safe electronic pressure switches for the use in explosion hazard areas. Operating The display module, which is mounted rotatable in the ball housing, shows the system pressure and allows programming. The configuration is menu controlled and easy to handle without previous knowledge. Applications machine and plant engineering test benches environmental engineering Characteristics indication of measured values on a 4-digit LED display rotatable and configurable display module configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay) option analogue output: - -wire version: 4... 20 ma or 0... 0 V with turn-down :6-2-wire version: 4... 20 ma Ex-protection optionally special functions (access protection, min. / max. value memory) industrial standard in view of accuracy, thermal behaviour and long term stability Electronic Pressure Switch

Data Sheet Page 2/5 Input pressure range Nominal pressure gauge [bar] -... 0 0. 0.25 0.4 2.5 4 0 25 40 Nominal pressure abs. [bar] - 0. 0.25 0.4 2.5 4 0 25 40 Permissible overpressure [bar] 6 20 60 60 00 Nominal pressure gauge [bar] 00 250 400 600 Nominal pressure abs. [bar] 00 250 400 600 Permissible overpressure [bar] 40 600 600 000 measurement starts with ambient pressure Number, type standard: PNP contact option: 2 independent PNP contacts Max. switching current 2-wire: contact rating 25 ma, short-circuit resistant; V switch = V S 2V -wire: contact rating 500 ma, short-circuit resistant Accuracy of contacts IEC 60770 BFSL standard: nominal pressure > 0.4 bar: nominal pressure 0.4 bar: ± 0.5 % FSO ± 0.50 % FSO ± 0.75 % FSO ± 0.250 % FSO option: nominal pressure > 0.4 bar: ± 0.25 % FSO ± 0.25 % FSO Repeatability ± 0, % FSO Switching frequency 2-wire: max. 0 Hz / -wire: 50 Hz Switching cycles > 00 x 0 6 Delay time 0... 00 sec. with Ex-protection max. contact possible 2 Analogue output (optionally) / Supply 2-wire current signal 4... 20 ma / V S = 8... 4 V DC = [(V S V S min ) / 0.02] Ω response time: < 0 ms 2-wire current signal with Ex-protection 4... 20 ma / V S = 7... 28 V DC = [(V S V S min ) / 0.02] Ω response time: < 0 ms -wire current signal 4... 20 ma / V S = 24 V DC ± 0 % adjustable (turn-down of span :6) = 500 Ω response time: < 0 ms -wire voltage signal 0 0 V / V S = 24 V DC ± 0 % adjustable (turn-down of span :6) permissible load: R min = 0 kω response time: < 0 ms Accuracy IEC 60770 4 BFSL Without analogue output V S = 5... 6 V DC standard: nominal pressure > 0.4 bar: nominal pressure 0.4 bar: ± 0.5 % FSO ± 0.50 % FSO ± 0.75 % FSO ± 0.250 % FSO option: nominal pressure > 0.4 bar: ± 0.25 % FSO ± 0.25 % FSO with turn-down of span the analogue signal is adjusted automatically to the new measuring range 4 accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal errors (offset and span) / Permissible temperatures Nominal pressure P N [bar] -... 0 0. 0.25 0.4 > Tolerance band [% FSO] ± 0.75 ± 2 ±.5 ± ± ± 0.75 TC, average [% FSO / 0 K] ± 0.07 ± 0. ± 0.2 ± 0.4 ± 0. ± 0.07 in compensated range [ C] 0... 70 0... 50 0... 70 Permissible temperatures medium: -25... 25 C electronics / environment: -25... 85 C storage: -40... 85 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 626 Mechanical stability Vibration 5 g RMS (20... 2000 Hz) Shock 00 g / msec. Materials Pressure port stainless steel.457 (6Ti) Housing stainless steel.40 (04) Viewing glass laminated safety glass Seals (media wetted) standard: P N 40 bar: FKM / P N > 40 bar: NBR option: welded version for pressure ports according to EN 87 with pressure ranges P N between 0.25 bar and 40 bar; others Diaphragm stainless steel.445 (6L) Media wetted parts pressure port, seals, diaphragm

Data Sheet Page /5 Explosion protection (for 2-wire current signal with Ex-protection) Approval AX4- zone 0: II G EEx ia IIC T4 Safety techn. maximum values U i = 28 V, I i = 9 ma, P i = 660 mw Max. switching current 5 70 ma Permissible temperatures for in zone 0: -20... 60 C with p atm 0,8 bar up to, bar environment in zone : -25... 70 C Connecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 60 pf/m cable inductance: signal line/shield also signal line/signal line: µh/m 5 the real switching current in the application depends on the power supply unit Miscellaneous Display Current consumption (without contacts) Ingress protection IP 67 Installation position any 6 Weight approx. 400 g Operational life > 00 x 0 6 cycles 4-digit, 7-segment-LED display, visible range 7.2 x mm; digit height 0 mm, range of indication -999... +9999; accuracy 0, % ± digit; digital damping 0. 0 sec (programmable); measured value update 0.0 0 sec (programmable) 2-wire signal output current: max. 25 ma -wire signal output current: approx. 0 ma + signal current -wire signal output voltage: approx. 0 ma 6 Pressure switches are calibrated in a vertical position with the pressure connection down. If this position is changed on installation there can be slight deviation in the zero point for pressure ranges bar. Wiring diagrams 2-wire-system (current) p -wire-system (current / voltage) p V S V S Signal + A/V I Contact Contact I/U RL Pin configuration Electrical connection M2x metal (5-pin) cable colours (DIN 4700) Signal + (only -wire) Contact 2 4 5 white brown green grey pink Ground plug housing / pressure port yellow / green (shield) Electrical connection (dimensions in mm) M2x (5-pin) cable outlet 7 7 different cable types and lengths available Designs 8 side display 45 display () top display () 8 all designs in horizontal rotatable housing as standard

Data Sheet Page 4/5 Mechanical connections (dimensions in mm) G/2 EN 87 G/4 DIN 852 G/4 EN 87 M20x.5 M0x; M2x; M2x.5 (up to 00 bar) G/2 DIN 852 /2 NPT /4 NPT M20x.5 Optional for P N from 0. up to 40 bar G/2 flush DIN 852 M20x.5 G/4 flush DIN 852 () Total length of devices with nominal pressure range P N > 40 increases by 4 mm! Total length of devices with Ex-protection increases by 0 mm (with welded version by 20 mm)! This data sheet contains product specification, properties are not guaranteed. Subject to change without notice.

Data Sheet Page 5/5 Ordering code - - - - - - - - - Pressure Input Design (side display) (45 display) (top display) Analogue output without 4 20 ma / 2-wire 0 0 V / -wire, adjustable 4 20 ma / -wire, adjustable gauge absolute 7 A 0 7 A [bar] 0,0 0 0 0 0,25 2 5 0 0 0,40 4 0 0 0,0 0 0 2,5 2 5 0 4,0 4 0 0 0 0 0 2 25 2 5 0 2 40 4 0 0 2 00 0 0 250 2 5 0 400 4 0 0 600 6 0 0-0 X 0 2 9 K H K 4 K V 0 7 Intrinsic safety 4 20 ma / 2-wire 2 E Contact contact 2 contacts 2 2 Accuracy standard for P N > 0,4 bar 0,5 % standard for P N 0,4 bar 0,5 % 5 option for P N > 0,4 bar 0,25 % 2 Electrical connection M2x (5-pin) / metal version N 0 Cable outlet TA0 Mechanical connection G/2" DIN 852 G/2" EN 87 G/4" DIN 852 G/4" EN 87 0 0 2 0 0 0 0 4 0 0 G/2" DIN 852 with 4 flush senso F 0 0 G/4" DIN 852 with 4 flush senso K 0 0 /2" NPT /4" NPT N 0 0 N 4 0 Seals for P N 40 bar: FKM without (welded version) 5 2 for P N > 40 bar: NBR 5 Special version standard 0 0 0 from 00 bar: measurement starts with ambient pressure 2 with Ex version max. contact is possible different cable types and lengths deliverable (not encluded in the price); code for PVC cable without ventilation tube 4 not possible for nominal pressure P N > 40 bar; also not possible for vacuum ranges 5 welded version only with pressure ports according to EN 87; not available with pressure ranges 0. bar and > 40 bar This ordering code contains product specification; properties are not guaranteed. Subject to change without notice.