specification display & lighting hera spectrometer

Similar documents
specification display applications hera spectrometer

specification light bulb cronus bhaskar spectrometer & colorimeter for light bulb measurements

specification cylon colorimeter

operating manual iliad for Windows & Mac OS X software application rc81

LED Lighting Flux and Color Measurement System (LFC)

Broadbandradiometer specbos 1211

Chameleon Spectroradiometer

Spectroradiometer specbos 1201

Miniaturized Spectroradiometer

LED Tester BTS256-LED

We bring quality to light. MAS 40 Mini-Array Spectrometer

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

Microscope-Spectrometer

The Art of Light Measurement. Avantes BV Apeldoorn, The Netherlands

JETI Specbos Instruments

INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

NVLAP LAB CODE:

GL spectis 1.0 Touch The world s first smart spectrometer.

Horticultural Lighting Test Report

LED Tester BTS256-LED

Photometry and Light Measurement

We bring quality to light. CAS 120 CCD Array Spectrometer

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

illumia Plus Temperature Controlled Light Measurement Systems

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0.

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

Photometric Indoor Test Report

GL SPECTIS 1.0 Touch The world s first smart spectrometer

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0.

BTS2048-VL-CP-ILED-B-IS-1.0-HL

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P20-L360-C27-B25 tel: fax: lm x 0.

NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

LEADING THE WAY in Light Measurement Systems

Gamma Scientific Display Measurement Systems

AvaLight-DHc Full-range Compact Light Source

Measuring colour in a world of light

High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc.

NVLAP LAB CODE:

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE:

NVLAP LAB CODE:

NVLAP LAB CODE:

OtO Photonics. Light Source Datasheet. Description. Balance Light Series LS-BA. Halogen Light Series LS-HA

NVLAP LAB CODE:

Photometric Test Report

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

CAS 120. CCD Array Spectrometer. Two Global Leaders. One Complete Solution.

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

Imaging Photometer and Colorimeter

71332 LED Dusk To Dawn (Area Light)

Luminous Flux (lumens) System LM-ISP-XXXX

Report No.: HZ c

MK350 Portable Spectrometer

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Checked X.CAO

Dark Sky Wallpack 50W. General ACD12 Aluminum Heat Sink High Light Transmittance Polycarbonate, Anti-UV and Fire Resistant Finish:

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

We bring quality to light. CAS 140CT Array Spectrometer

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

Photometric Test Report

Report No.: HZ a. 60 mins Note. 4000K, frosted lens Table 1: Executive Data Summary

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

Report No.: EASZE Page 2 of 14

High-Accuracy Luminance & Chromaticity Measurement Comparable to Many Spectroradiometers

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

Photometry for Traffic Engineers...

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

PT39 LEDs. Thermally Enhanced. PT39-TE Product Datasheet. PT39-TE Product Datasheet. Features: Table of Contents. Applications

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

PGS Family Plane Grating Spectrometer from ZEISS

Photometric Test Report

Photometric Test Report

AvaLight-HAL-S-MINI Tungsten-Halogen Light Source

Miniature Spectrometer Technical specifications

Application Note (A16)

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

Checked X.CAO

LM-79 Test Report. GE Infusion M1000/830/W/N. Electrical and Photometric tests as required by IESNA LM-79 test standard

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

NVLAP LAB CODE LM Test Report. For EIKO GLOBAL, LLC W 84th St., Shawnee, KS

Optical Sensor Systems from Carl Zeiss CORONA PLUS. Tuned by Carl Zeiss. The next generation in the compact class

Transport Canada Standard for LED Signal Modules at Highway/Railway Grade Crossings. TC E-14 (October 10, 2003)

NVLAP LAB CODE LM Test Report. For LIGHT EFFICIENT DESIGN. (Brand Name: N/A) 188 S. Northwest Highway Cary, IL 60013

LZ1-00WW05. LedEngin, Inc. High Luminous Efficacy Warm White LED Emitter. Key Features. Typical Applications. Description

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

PT54 LEDs. PT54 Product Datasheet. Features: Table of Contents. Applications

NVLAP LAB CODE LM Test Report. For ATG ELECTRONICS CORP. (Brand Name: N/A) th Street Rancho Cucamonga, CA 91730

Company synopsis. MSU series

Transcription:

specification display & lighting hera spectrometer

Contents 1 Hera: cost effective spectrometer... 3 2 Highlights... 3 3 Speed & ease of use... 4 1 General specification Hera... 4 2 Hera series specifications... 5 3 Integrating spheres, fibers and OD filters... 6 4 Speed & performance Hera 01 with AIS 75... 7 5 Speed & performance Hera 01 with AIS 150... 8 6 Speed & performance Hera 01 with AIS 250... 9 7 Hera lens and fiber specifications... 10 8 Hera M8 fiber dimensions... 11 9 Hera cosine corrector dimensions... 12 10 Hera 20mm dimensions... 13 11 Hera 10mm dimensions... 14 12 Hera 5mm dimensions... 15 2

1 Hera: cost effective spectrometer for display & lighting measurements The Hera Series spectrometers is ideal for display and LED measurements where ease of use, stability, performance and price are key factors. Available in various spectral ranges. VIS spectrometers ranging from 380 to 780nm (Hera 01) and 360 to 830nm (Hera 02). A UV spectrometer with a range from 190 to 435nm (Hera 03) and UV-NIR with a range of 200 to 1100nm (Hera 04). For measurements of light sources Admesy offers a range of integrating spheres which can be connected through M8 fiber connections. A fixed position fiber connector has been developed to connect the optical fiber in a fixed and uniform way from calibration to final use. Due to this fixed position measurement results are more stable. Furthermore, the Hera series is available in a variety of optical systems: 5, 10 or 20mm collimating lens for display measurements or a 1cm 2 cosine corrector. 2 Highlights Various spectral ranges including UV, VIS and NIR Determines both spectral output and colour values Auto-range function Excellent linearity over entire dynamic range Dark current compensated, virtually zero over entire integration range Holographic grating for low stray light USBTMC compliant, SCPI command set, high speed device USB, RS232, Ethernet connections and trigger in & out for ideal system integration All calculations are carried out inside the device, saving processing power in production environments Robust housing, optimized for mounting and protection in harsh production environments 3

3 Speed & ease of use Admesy strongly believes in developing and manufacturing devices where ease of use and speed are key factors. In order to achieve these aspects, Admesy considers the following aspects of spectrometers to be taken care of. Wavelength calibration Dark current Linearity Absolute calibration Calculations and compensations are done in a staggering 14ms. All this is possible due to the high speed processor inside the Hera combined with algorithms developed for this specific device. In production processes, no external calculation power is needed from computers. Data can be used directly in production settings without any delay of processing data afterwards. This saves time and processing power of the operating system of a production line. When for example setting the integration time to 10ms, full calibrated spectral data is processed within 24ms. This includes transferring data through high speed USB. This makes the Hera series an ideal LED sorting device where speeds up to 50 LEDs per second can be achieved. 1 General specification Hera Hera 01 Model Hera 01 VIS Spectral range 380-780nm Operating temperature 10-35 C Wavelength accuracy +/- 0.5nm Stray light <0.03% Luminance accuracy *2 +/-4% Chromaticity accuracy *2 +/- 0.002 Non - Linearity < 1% Integration time 2.5ms 20s Spectral resolution Selectable 0.5nm-1nm-2.5nm-5nm-10nm Interfaces High speed USB, RS232, Ethernet, Trigger connections Measurement parameters Spectral output, radiometric data or colour data (Lumen, x,y, DWL, PWL, CRI, CCT, etc.) Data processing time 14ms Size (LxWxH) 95 x 81 x 61mm (without optical system) Weight 650 gram Operating temperature 10-35 C Power consumption 1250mW Wavelength accuracy +/-0.5nm Luminance accuracy +/-4% (measured at standard illuminant A) Colour accuracy +/-0.002 (measured at standard illuminant A) 4

2 Hera series specifications Hera type 01 02 03 04 Spectral range 380 780nm 360 830nm 190 435nm 200 1100nm Optical resolution 2.3nm 2.3nm 0.7nm 1.7nm (FWHM) Order sorting filter 2 nd order sorting on chip 2 nd order sorting No order sorting filter Linear variable filter Wavelength accuracy +/-0.5nm +/-0.5nm +/-0.5nm +/-0.5nm Stray light <0.03% <0.03% <0.03% <0.03% Lumen accuracy +/-4% +/-4% +/-5% +/-4% Chromaticity accuracy +/-0.002 +/-0.002 +/- 0.003 +/- 0.002 Luminous flux (AIS 75)¹ 1m 60lm 1m 60lm TBD 1m 60lm Luminous flux (AIS 150)¹ 5m 300lm 5m 300lm TBD 5m 300lm Luminous flux (AIS 250)¹ 10m 600lm 10m 600lm TBD 10m 600lm Note: Specification is subject to change without notification, no legal rights can be derived from this specification. Note: Specification of models which are not in production can change. Note: Typical value, contact us for different FWHM values. Note: After calibration to the calibration standard, UV model is checked with 400nm LED s. Note: OD filters can be incorporated for higher ranges into the spheres. 5

3 Integrating spheres, fibers and OD filters Admesy offers three integrating sphere sizes. Besides, Admesy can help with customizing integrating spheres for production processes or (re)calibrate integrating spheres. Admesy uses a special M8 fiber connection which has been developed to connect the optical fiber in a consistent way to ensure best possible repeatability. A higher measurement range can be achieved by implementing neutral density filters (OD filters) in the measurement setup. Admesy offers several OD filters to optimize the Hera for any measurement setup. Model Diameter Auxiliary lamp Application Type of DUT AIS 75 75mm No Production Standard single LEDs AIS 150 150mm Yes Production Laboratory Standard single LEDs High power LEDs AIS 250 250mm Yes Laboratory, CIE 127 compliant for 2π measurements Standard single LEDs High power LEDs Small LED modules 6

4 Speed & performance Hera 01 with AIS 75 Measurement conditions Used light source White LED Integrating sphere size 75mm (AIS 75) Spectral resolution 1nm Averaging 1 Autorange Off Temperature 24º Repeatability at 60lm +/-80% 2.5 <0.2% +/-0.003 16.5 Repeatability at 15lm +/-80% 10 <0.2% +/-0.0003 24 +/-40% 5 <0.3% +/-0.0004 19 +/-20% 2.5 <0.4% +/-0.0008 16.5 Repeatability at 5lm +/-80% 32 <0.2% +/-0.0003 46 +/-40% 16 <0.3% +/-0.0004 30 +/-20% 8 <0.4% +/-0.0008 22 +/-10% 4 <0.7% +/-0.0012 18 Repeatability at 1lm +/-80% 160 <0.2% +/-0.0003 174 +/-40% 80 <0.3% +/-0.0004 94 +/-20% 40 <0.4% +/-0.0008 54 +/-10% 20 <0.7% +/-0.0012 34 Repeatability at 0.1lm +/-80% 1600 <0.2% +/-0.0003 1614 +/-40% 800 <0.3% +/-0.0004 814 +/-20% 400 <0.4% +/-0.0008 414 +/-10% 200 <0.7% +/-0.0012 214 Measurements are real life taken and may vary slightly from device to device. 7

5 Speed & performance Hera 01 with AIS 150 Measurement conditions Used light source White LED Integrating sphere size 150mm (AIS 150) Spectral resolution 1nm Averaging 1 Autorange Off Temperature 24º Repeatability at 300lm +/-80% 2.5 <0.2% +/-0.003 16.5 Repeatability at 75lm +/-80% 10 <0.2% +/-0.0003 24 +/-40% 5 <0.3% +/-0.0004 19 +/-20% 2.5 <0.4% +/-0.0008 16.5 Repeatability at 25lm +/-80% 32 <0.2% +/-0.0003 46 +/-40% 16 <0.3% +/-0.0004 30 +/-20% 8 <0.4% +/-0.0008 22 +/-10% 4 <0.7% +/-0.0012 18 Repeatability at 5lm +/-80% 160 <0.2% +/-0.0003 174 +/-40% 80 <0.3% +/-0.0004 94 +/-20% 40 <0.4% +/-0.0008 54 +/-10% 20 <0.7% +/-0.0012 34 Repeatability at 0.5lm +/-80% 1600 <0.2% +/-0.0003 1614 +/-40% 800 <0.3% +/-0.0004 814 +/-20% 400 <0.4% +/-0.0008 414 +/-10% 200 <0.7% +/-0.0012 214 Measurements are real life taken and may vary slightly from device to device. 8

6 Speed & performance Hera 01 with AIS 250 Measurement conditions Used light source White LED Integrating sphere size 250mm (AIS 250) Spectral resolution 1nm Averaging 1 Autorange Off Temperature 24º Repeatability at 600lm +/-80% 2.5 <0.2% +/-0.003 16.5 Repeatability at 150lm +/-80% 10 <0.2% +/-0.0003 24 +/-40% 5 <0.3% +/-0.0004 19 +/-20% 2.5 <0.4% +/-0.0008 16.5 Repeatability at 50lm +/-80% 32 <0.2% +/-0.0003 46 +/-40% 16 <0.3% +/-0.0004 30 +/-20% 8 <0.4% +/-0.0008 22 +/-10% 4 <0.7% +/-0.0012 18 Repeatability at 10lm +/-80% 160 <0.2% +/-0.0003 174 +/-40% 80 <0.3% +/-0.0004 94 +/-20% 40 <0.4% +/-0.0008 54 +/-10% 20 <0.7% +/-0.0012 34 Repeatability at 1lm +/-80% 1600 <0.2% +/-0.0003 1614 +/-40% 800 <0.3% +/-0.0004 814 +/-20% 400 <0.4% +/-0.0008 414 +/-10% 200 <0.7% +/-0.0012 214 Measurements are real life taken and may vary slightly from device to device. 9

7 Hera lens and fiber specifications The Hera series is available with several lens systems, available as fixed optics and optics with fibers. For fiber connections, Admesy uses M8 connectors. This connector has been developed to connect the optical fiber in a consistent way to ensure the best possible repeatability. 5, 10, 20mm lens systems IDMS system VMS system Model 1 2 3 4 5 Description 20mm lens 10mm lens 5mm lens IDMS VMS Target Display Display Display Display Variable message signs FOV¹ N/a N/a N/a +/-1º +/-1.5º Acceptance +/-0.3º +/-0.6º +/-0.6º +/-1º +/-0.5º angle Luminance 0.1 6000 0.1 6000 0.4 20,000 TBD TBD range (cd/m²) Working 100mm 100mm 100mm TBD TBD distance (WD) Spot size at WD 21mm 12.6 7.7 TBD TBD Spot size at WD 20.5mm 11.3 6.3 TBD TBD 50mm Spot size at WD +50mm 21.5mm 13.9 9.1 TBD TBD 1 Models 1, 2 and 3 are collimating lens systems and can be used closely to the display. 10

8 Hera M8 fiber dimensions 11

9 Hera cosine corrector dimensions 12

10 Hera 20mm dimensions 13

11 Hera 10mm dimensions 14

12 Hera 5mm dimensions 15

Admesy B.V. Branskamp 5 6014 CB Ittervoort The Netherlands T +31 (0)475 600 232 F +31 (0)475 600 316 www.admesy.com info@admesy.com The material in this document is subject to change. No rights can be derived from the content of this document. All rights reserved. No part of this document may be reproduced, stored in a database or retrieval system, or published in any form or way, electronically, mechanically, by print, photo print, microfilm or any other means without prior written permission from the publisher. Version 1.0.7 04/2016 16