Shrink temperature of 120 C. High-impact, abrasion, corrosion and chemical resistance. Rated for 600V, 90 C continuous use

Similar documents
Heat-Shrinkable Tubing

Shrink temperature of 120 C. Rated for 600V, 90 C continuous use. T&B recommended up to 1kV. HS Series Specifications

Heatex Identification System. The Heatex Product Programme Offers:

DETAIL SPECIFICATION SHEET INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, POLYOLEFIN, DUAL-WALL, OUTER WALL CROSSLINKED

3 Heat Shrinkable Products

FTZ New Products COOL SEAL CLEAR SEAL EXTREME SEAL CORRECT CONNECT MPC CRIMP TOOL SEAMLESS COPPER LUGS. Qua lity Sta tement

Heat Shrinkable Tubing SA47, SA47-LA, SA47-HT

Suflex Astra 703/105. Features. Product Description. Suggested Applications VW-1 Rated Mechanical Tubing

CABLE JOINTING KITS &

Resist water & condensation Resist salt & other contaminants Resist wire pull out & current leakage

CIR (Crush & Impact Resistant) VFD Power Cable

Low Voltage Splices, 1000 V or less

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

SPEC 55 Wire and Cable High-performance wire and cable insulation system for 65 C to 200 C

JCN cables. The. splice is an

END CAP & HEAT SHRINK SLEEVE

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

Low Voltage Splices 0-600V (1000V rated) Cold Shrink Splices (0-1000V)

Drexan Energy Systems Inc.


BURNDY EC&M TYPE YGA HYLUG Terminals. TYPE YGHA HYLUG Terminals. TYPE YGIB GROUNDLINK Connector. TYPE YGHS HYLINK Ground Splice

AEE. Canada. Australia

LGH High Voltage Connectors

Interconnect and Termination Devices

NiAc Terminals and Splices

8 to 32 AWG Solid Round Copper ranges from to ranges from to C. Polyester/Polyamideimide

14 AWG 2 AWG: 600 Volt

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Model Color Wire Combination Range Wire Combination Range (mm) Quantity Cat. No. Box of V. Carton of 1, Gray.

Glenair s Series 80 ASAP Cordsets for High-Speed Ethernet, USB and Firewire Applications

COPPER MAGNET WIRE GP/MR C

DUPONT KAPTON POLYIMIDE FILM

Carton of 1, B. Min. 2-,34mm 2 Max. 3-1,5mm V 22 to 14 AWG Min. 2 #22 Max. 3 #16. ,34mm 2 to 2,5mm 2. Min.

SECTION ELECTRICAL IDENTIFICATION

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

Wire-to-Wire Splicing

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

Medium Voltage Power Cables

QSLVM2500 QSLV-M Cold Shrink Insulator

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

3 Splices. Splices. 5700A-MT Trifurcating Accessory Kit pg. 302 MT-C pg. 302 MT-E pg. 302

Wire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3

Interconnect and Termination Devices

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

insulate seal protect EquipmEnt insulation and ConnECtion products

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

ElectroSeal Conductive Elastomer Material

DLO Flexible Power Cable

Instrumentation Cables

SEALED CRIMP CONNECTORSTM

Precision Thermistor Sensors

Ground Clamps Cable Tray

JUN FEATURE 2014 PRODUCT OF THE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

tion sula usb Low Voltage Switchboard Equipment

GEXOL WORLD CLASS OIL & GAS CABLES

Interconnect and Termination Devices. A Comprehensive Range of INTERCONNECTION DEVICES

Connecting Systems for Cable Repair (Cable Splices)

H e a t s h r i n k N o r t h A m e r i c a n

Heatshrink. Moulded Shapes. HellermannTyton. North American Product Guide

SPEC 44. Wire and cable

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

Thru Wall Floor Seals For New Installation

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

SLEEVING (CONVOLUTED) SLEEVING (SPLIT CONVOLUTED) SLEEVING (PVC) 56 AUTO MARINE PRODUCT CATALOGUE 2018/19 VISIT:

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

Spec wire. Performance Wire and Cable

UR Awg Butt Connector Box

DETAIL SPECIFICATION INSULATION SLEEVING, ELECTRICAL, HEAT SHRINKABLE, GENERAL SPECIFICATION FOR

Polyolefin, cross-linked (POX) Shrink Ratio 3:1 Longitudinal change +5%/-10% max. Minimum Shrink Temperature Operating Temperature +90 C

Mongoose PT Platform Shale Shaker

General Information...SA1-SA4

Portable Hacksaws for Tough Duty

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Creating. There is one basic question every customer needs to address when creating custom

High Temperature Flexible Control Cable OLFLEX

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

APR FEATURE PRODUCT OF THE MONTH. Prices good through August 31, 2015

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

Color-Keyed. Compression Connector System. Table of Contents

3M Scotchlok Insulated Electrical Spring Connector B (Blue)

Portable Hacksaws for Tough Duty

CITY OF TACOMA Transmission & Distribution

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

A S J ASJ PTE LTD LEAD FREE THIN FILM CHIP RESISTOR SPECIFICATION. Reference No. : SYS-ENG-209. Revision No. : D

TIGER BRAND MINING CABLES

SUBMITTAL COVER SHEET

Airport Cables & Connectors

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

Psi casing ENd seals type Kt type du type KG/Ko type HA type stm

FIT Sleeving for Rugged Applications

Non-Submersible Industrial Pressure Transducer

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)

Wire and Cable Heat-shrink Tubing Non-shrink Tubing Braided Sleeving Screening Braids Moulded Parts Terminals and Splices Wire and Cable Markers

Transcription:

HS Series 3:1 Shrink Ratio Made of thermally stabilized cross-linked polyolefin, enabling a recovered wall thickness greater than that of the cable jacket replaced Withstands severe mechanical requirements of U.R.D., submersible, and direct burial installations Tubing, featuring an internally applied sealant, offers protection against moisture, and may be used over lead, steel, aluminum, copper, standard plastic and elasmeric insulating materials Shrink temperature of 120 C High-impact, abrasion, corrosion and chemical resistance Rated for 600V, 90 C continuous use Thermoplastic adhesive liner provides complete environmental protection and insulation Meets: UL and CSA standards, ANSI C119.1, Western Underground Guide Numbers 2.4, 2., ICEA and NEMA insulation thickness requirements Continuous operating temperature: - C 110 C HS Series Specifications T&B recommended up 1 kv AS D412, ISO 37 ELONGATION 600% ELONGATION AFTER HEAT AGING (168 HRS. AT 10 O C) 00% AS D2671 LONGITUDINAL CHANGE +1%, -10% LOW TEMPERATURE FLEXIBILITY (4 HRS. AT - O C) SPECIFIC GRAVITY AS D792 1.1 HARDNESS (SHORE D) AS D2240 0D DIELECTRIC STRENGTH AS D149 00 V/Mil (20kV/mm) DIELECTRIC VOLTAGE WITHSTAND (00V, 600HZ, 1 MIN.) UL 486D No Breakdown, 24kV 1 min., 1kV 4 hrs. VOLUME RESISTIVITY AS D7 1016 ohm-cm FLUID RESISTANCE MIL-DTL-2303 Good Excellent FUNGUS RESISTANCE AS G21 No growth COPPER CORROSION AS D2671 No corrosion WATER ABSORPTION AS D70 0.1% ADHESIVE LAP SHEER (1 IN./MIN. AT 23 O C) AS D1002 1 psi (0.87 MPa) ADHESIVE SOFTENING POINT AS E28 90 o C± o C AS D 1000 WATER PENETRATION S 706 No penetration after 236 hrs. of continuous immersion C4

HS Series Black I.D. I.D. Order multiple is std. pkg. All lengths have facry-applied sealant **UL not applicable Red Order multiple is std. pkg. All lengths have facry-applied sealant Nom. Wall Fits any listed or certified AL or CU splice with dia. no larger than O.D. Heavy-Wall Tubing ( ft. rolls) Black Cable Range HS16-12 3 #14 AWG HS16-12L 0.3 0.12 0.07 6 0.27 1.00 HS16-12-4 48 #10 AWG HS12-6 3 #8 AWG HS12-6L 0.1 0.16 0.08 6 0.38 1.7 HS12-6-4 48 #6 AWG HS6-1 4 #6 AWG HS6-1L 0.7 0.24 0.12 8 0.63 2.0 HS6-1-4 48 #2 AWG HS4-30 #1 AWG 20 HS4-30L 1.10 0.3 0.12 9 0.7 3. 10 HS4-30-4 48 3/0 AWG HS40-400 8 2/0 kcmil HS40-400L 1.0 0.47 12 10 HS40-400-4 48 30 kcmil HS00-1000 9 0 kcmil HS00-1000L 2.00 0.63 0.16 1 HS00-1000-4 48 00 kcmil HS12-30** 12 800 kcmil 2 HS30-30** 3.4 1.18 30 HS30-4** 48 10 kcmil HS12-40** 12 100 kcmil HS30-40** 4.72 1.7 0.17 30 1 HS40-4-TB 48 00 kcmil I.D. I.D. For 2-Way Connecr Cable Sizes HS12-6LR 0.1 0.16 6 #8 6 AWG HS6-1LR 0.7 0.24 8 #6 2 AWG HS4-30LR 1.10 0.3 9 #1 3/0 AWG 10 Pkg. Qty. I.D. I.D. Nom. Wall Order by reel, not by feet. ft. reels not supplied with facry applied sealant For 2-Way Connecr Cable Sizes HS16-12- 0.3 0.12 0.07 #14 10 AWG HS12-6- 0.1 0.16 #8 6 AWG 0.08 HS6-1- 0.7 0.24 #6 #2 AWG HS4-30- 1.10 0.3 0.12 #1 3/0 AWG HS40-400- 1.0 0.47 2/0 30 kcmil 0.16 HS00-1000- 2.00 0.63 0 00 kcmil 1 C

HSHR Series 6:1 Shrink Ratio High Shrink Ratio Accommodates a wide variety of connecr shapes and configurations Thermoplastic adhesive liner for complete environmental protection and insulation Continuous operating temperature: - C 110 C Shrink temperature: 120 C Flame retardant HSHR Series Specifications I.D. I.D. Nominal Wall Code Cable Size Standard HSHR70-4 0.7 0.13 0.10 #22 #46 AWG HSHR1300-4 1.30 0.22 0.12 #8 700 AWG HSHR170-4 1.7 0.29 #4 1000 AWG 0.13 HSHR2000-4 2.00 0.33 #2 10 AWG 48 HSHR270-4 2.7 0.46 0.14 1/0 100 kcmil 1 HSHR300-4 3.0 0.8 3/0 170 kcmil 10 0.1 HSHR4700-4 4.70 0.78 300 2000 kcmil AS D412, ISO 37 ELONGATION 600% ELONGATION AFTER HEAT AGING (168 HRS. AT 10 O C) AS D2671 LONGITUDINAL CHANGE +1%, -10% LOW TEMPERATURE FLEXIBILITY (4 HRS. AT - O C) 00% SPECIFIC GRAVITY AS D792 1.1 HARDNESS (SHORE D) AS D2240 0D DIELECTRIC STRENGTH AS D149, IEC 243 00 V/Mil (20kV/mm) DIELECTRIC VOLTAGE WITHSTAND (00 V, 60HZ, 1 MIN.) UL 486D No Breakdown, 1kV 4 hrs. VOLUME RESISTIVITY AS D7 1016 ohm-cm FLUID RESISTANCE MIL-DTL-2303/1 Good Excellent FUNGUS RESISTANCE AS G21 No growth COPPER CORROSION AS D2671 No corrosion WATER ABSORPTION AS D70 0.1% ADHESIVE LAP SHEER (1 IN./MIN. AT 23 O C) AS D1002 1 psi (0.87 MPa) ADHESIVE SOFTENING POINT AS E28 90 o C± o C AS D 1000 ADHESIVE BLOCKING (30 O C) AS D1146 No blocking WATER PENETRATION S 706 No penetration after 236 hrs. of continuous immersion C6

HSFR Series Flame-Retardant Heavy-Wall Insulates and protects electrical splices and terminations High-impact and abrasion resistance Thermoplastic adhesive liner Rated for 600V, 90 C continuous use. Continuous operating temperature: - C 110 C Shrink temperature of 120 C Meets: UL and CSA standards, ANSI C119.1, Western Underground Guide Nos. 2.4, 2., MIL-DTL-2303/1, IEEE 383 Vertical Flame Test, ANSI C37.20.2, ICEA S-19-8 and NEMA insulation thickness requirements 3:1 Shrink Ratio HSFR Series Specifications I.D. I.D. Order multiple is std. pkg. Standard colour: black Nominal Wall Code Cable Size HSFR16-12-4 0.3 0.12 0.07 #14 #10 AWG HSFR12-6-4 0.1 0.16 #8 #6 AWG 0.09 HSFR6-1-4 0.7 0.24 #6 #2 AWG HSFR4-30-4 1.10 0.3 0.12 #1 3/0 AWG HSFR40-400-4 1.0 0.47 2/0 30 kcmil 0.16 HSFR00-1000-4 2.00 0.63 0 00 kcmil Standard 48 AS D412, ISO 37 ELONGATION 600% LONGITUDINAL CHANGE AS D2671 +1%, -10% SPECIFIC GRAVITY AS D792 1.2 ELONGATION AFTER HEAT AGING (168 HRS. AT 17 O C) AS D2671, ISO 37 00% AS D2671 LOW TEMPERATURE FLEXIBILITY (4 HRS. AT - O C) or splitting HARDNESS (SHORE D) AS D2240 0D OXYGEN INDEX AS D2863 27.00 FLAMMABILITY AS D2671 Flame Retardant DIELECTRIC STRENGTH AS D149 00 V/Mil (20kV/mm) DIELECTRIC VOLTAGE WITHSTAND (00 V, 60HZ, 1 MIN.) UL 486D No Breakdown, 24kV 4hrs, 1kV 4 hrs. VOLUME RESISTIVITY AS D7 1016 ohm-cm FLUID RESISTANCE MIL-DTL-2303/ Good Excellent FUNGUS RESISTANCE AS G21 No growth COPPER CORROSION AS D2671 No corrosion WATER ABSORPTION AS D70 0.2% ADHESIVE LAP SHEER (1 IN./MIN. AT 23 O C) AS D1002 1 psi (0.87 MPa) ADHESIVE SOFTENING POINT AS E28 90 o C± o C AS D 1000 ADHESIVE BLOCKING (30 O C) AS D1146 No blocking ADHESIVE WATER ABSORPTION AS D70 Less than 0.3% WATER PENETRATION S 706 No penetration after 286 hrs. of continuous immersion C7

HSC Series 3:1 Shrink Ratio Provides effective method for sealing cable ends, pipe conduit, etc. Extra thickness at the tip of the end cap prevents sharp ends of the cable from puncturing the seal Flame retardant Rated from 600/1000V, 90 degrees continuous use Shrink temperature of 120 C Resistant common fluids and solvents liner provides complete environmental protection and insulation Heat indicating lines. Continuous operating temperature: - C 110 C Heat-Shrinkable End Caps HSC Series Specifications I.D. I.D. Wall Order multiple is std. pkg. *Not UL Listed or CSA Certified Code Cable Size Nom. HSC8-4 0.1 0.16 #8 #6 AWG 0.09 2.0 100 HSC2-20 0.7 0.24 #6 #2 AWG HSC30-0 1.10 0.3 0.12 #1 3/0 AWG 3.00 HSC300-600 1.0 0.47 2/0 30 kcmil 3. 0 HSC700-1000 2.00 0.63 0 00 kcmil 3.0 0.16 HSC70 2.70 0.87 600 1000 kcmil 4.00 10 HSC300* 3.0 1.18 800 10 kcmil 4.0 HSC00* 4.70 1.7 0.17 100 00 kcmil.0 ELONGATION AS D412, ISO 37 0% ELONGATION AFTER HEAT AGING (168 HRS. AT 10 O C) 00% LONGITUDINAL CHANGE ON RECOVERY AS D2671 +1%, -10% LOW TEMPERATURE FLEXIBILITY (4 HRS. AT - O C) SPECIFIC GRAVITY AS D792 1.1 HARDNESS (SHORE D) AS D2240 0D DIELECTRIC STRENGTH AS D149, IEC 243 00 V/Mil (20kV/mm) DIELECTRIC VOLTAGE WITHSTAND (00 V, 60HZ, 1 MIN.) UL 486D No Breakdown, 1kV 4 hrs. VOLUME RESISTIVITY AS D7 1016 ohm-cm FLUID RESISTANCE MIL-DTL-2303 Good Excellent FUNGUS RESISTANCE AS G21 No growth COPPER CORROSION AS D2671 No corrosion WATER ABSORPTION AS D70 0.1% ADHESIVE LAP SHEER (1 IN./MIN. AT 23 O C) AS D1002 1 psi (0.87 MPa) ADHESIVE SOFTENING POINT AS E28 90 o C± o C AS D 1000 (mod.) ADHESIVE BLOCKING (30 O C) AS D1146 No blocking WATER PENETRATION S 706 No penetration after 236 hrs. of continuous immersion ROOM TEMPERATURE 168 hrs./40 psi TEMP. CYCLING (-40 O C TO 60 O C) 0 cycles/1 psi No leaks BURST PRESSURE 100 psi (0.70 MPa) C8

HSB Series Heat-Shrinkable Breakout Boots Boots for 2-, 3- and 4-way cable breakouts Thermoplastic adhesive liner provides complete environmental protection and insulation Meets ESI 09-11 Strain relief and mechanical protection Continuous operating temperature: - C 100 C Shrink temperature of 13 C TB TL Wall Thickness of Body Wall Thickness of Leg D d L Heat-Shrinkable Breakout Boots Order multiple is std. pkg. No. Legs HSB Series Specifications Dia. (min.) D d L TB TL Dia. (max.) Dia. (min.) Dia. (max.) (nom.) Wall Thickness of body (nom.) Wall Tickness of legs (nom.) Application Legs 600V Conducr AWG/kcmil HSB200-7-2 2 1.97 0.90 0.83 0.30 4.69 0.13 0.13 #3 300 HSB120-0-3 1.0 0.0 0.6 0.16 4.47 0.11 0.11 #8 3/0 HSB170-82-3 3 2.20 0.89 1.20 0.3 7.09 0.12 0.12 #1 600 HSB240-112-3 2.83 1.38 1.46 0.69 7.01 0.16 0.12 300 1000 HSB1-0-4 1.83 0.47 0.9 0.12 3.74 0.10 0.08 #12 2/0 HSB17-82-4 4 2.36 0.90 1.18 0. 7.9 0.16 #4 600 0.13 HSB26-120-4 3.10 1.40 1.0 0.49 9.4 0.13 3/0 1000 HSB30-138-3 3.4 1.34 1.38 0. 7.87 0.12 0.08 4/0 1000 HSB430-17-3 3 4.33 1.38 1.7 0.69 7.01 0.16 0.12 300 1000 HSB490-200-3 4.92 2.32 2.00 1.00 11.14 0.1 0.1 40 1000 HSB20-13-4 4. 3.00 1.3 0. 10.02 0.13 0.16 4/0 1000 10 ULTIMATE ELONGATION AS D412, ISO 40 600% ELONGATION AFTER HEAT AGING (168 HRS. AT 17 O C) 20% No dripping, cracking, flowing AS2671 LOW TEMPERATURE FLEXIBILITY (- O C) FLAMMABILITY AS D630 Self ext. within 1.97 sec. DIELECTRIC STRENGTH AS D2671 280 V/Mil (11kV/mm) WATER ABSORPTION AS D70 0.03% C9