HS Series 3:1 Shrink Ratio Made of thermally stabilized cross-linked polyolefin, enabling a recovered wall thickness greater than that of the cable jacket replaced Withstands severe mechanical requirements of U.R.D., submersible, and direct burial installations Tubing, featuring an internally applied sealant, offers protection against moisture, and may be used over lead, steel, aluminum, copper, standard plastic and elasmeric insulating materials Shrink temperature of 120 C High-impact, abrasion, corrosion and chemical resistance Rated for 600V, 90 C continuous use Thermoplastic adhesive liner provides complete environmental protection and insulation Meets: UL and CSA standards, ANSI C119.1, Western Underground Guide Numbers 2.4, 2., ICEA and NEMA insulation thickness requirements Continuous operating temperature: - C 110 C HS Series Specifications T&B recommended up 1 kv AS D412, ISO 37 ELONGATION 600% ELONGATION AFTER HEAT AGING (168 HRS. AT 10 O C) 00% AS D2671 LONGITUDINAL CHANGE +1%, -10% LOW TEMPERATURE FLEXIBILITY (4 HRS. AT - O C) SPECIFIC GRAVITY AS D792 1.1 HARDNESS (SHORE D) AS D2240 0D DIELECTRIC STRENGTH AS D149 00 V/Mil (20kV/mm) DIELECTRIC VOLTAGE WITHSTAND (00V, 600HZ, 1 MIN.) UL 486D No Breakdown, 24kV 1 min., 1kV 4 hrs. VOLUME RESISTIVITY AS D7 1016 ohm-cm FLUID RESISTANCE MIL-DTL-2303 Good Excellent FUNGUS RESISTANCE AS G21 No growth COPPER CORROSION AS D2671 No corrosion WATER ABSORPTION AS D70 0.1% ADHESIVE LAP SHEER (1 IN./MIN. AT 23 O C) AS D1002 1 psi (0.87 MPa) ADHESIVE SOFTENING POINT AS E28 90 o C± o C AS D 1000 WATER PENETRATION S 706 No penetration after 236 hrs. of continuous immersion C4
HS Series Black I.D. I.D. Order multiple is std. pkg. All lengths have facry-applied sealant **UL not applicable Red Order multiple is std. pkg. All lengths have facry-applied sealant Nom. Wall Fits any listed or certified AL or CU splice with dia. no larger than O.D. Heavy-Wall Tubing ( ft. rolls) Black Cable Range HS16-12 3 #14 AWG HS16-12L 0.3 0.12 0.07 6 0.27 1.00 HS16-12-4 48 #10 AWG HS12-6 3 #8 AWG HS12-6L 0.1 0.16 0.08 6 0.38 1.7 HS12-6-4 48 #6 AWG HS6-1 4 #6 AWG HS6-1L 0.7 0.24 0.12 8 0.63 2.0 HS6-1-4 48 #2 AWG HS4-30 #1 AWG 20 HS4-30L 1.10 0.3 0.12 9 0.7 3. 10 HS4-30-4 48 3/0 AWG HS40-400 8 2/0 kcmil HS40-400L 1.0 0.47 12 10 HS40-400-4 48 30 kcmil HS00-1000 9 0 kcmil HS00-1000L 2.00 0.63 0.16 1 HS00-1000-4 48 00 kcmil HS12-30** 12 800 kcmil 2 HS30-30** 3.4 1.18 30 HS30-4** 48 10 kcmil HS12-40** 12 100 kcmil HS30-40** 4.72 1.7 0.17 30 1 HS40-4-TB 48 00 kcmil I.D. I.D. For 2-Way Connecr Cable Sizes HS12-6LR 0.1 0.16 6 #8 6 AWG HS6-1LR 0.7 0.24 8 #6 2 AWG HS4-30LR 1.10 0.3 9 #1 3/0 AWG 10 Pkg. Qty. I.D. I.D. Nom. Wall Order by reel, not by feet. ft. reels not supplied with facry applied sealant For 2-Way Connecr Cable Sizes HS16-12- 0.3 0.12 0.07 #14 10 AWG HS12-6- 0.1 0.16 #8 6 AWG 0.08 HS6-1- 0.7 0.24 #6 #2 AWG HS4-30- 1.10 0.3 0.12 #1 3/0 AWG HS40-400- 1.0 0.47 2/0 30 kcmil 0.16 HS00-1000- 2.00 0.63 0 00 kcmil 1 C
HSHR Series 6:1 Shrink Ratio High Shrink Ratio Accommodates a wide variety of connecr shapes and configurations Thermoplastic adhesive liner for complete environmental protection and insulation Continuous operating temperature: - C 110 C Shrink temperature: 120 C Flame retardant HSHR Series Specifications I.D. I.D. Nominal Wall Code Cable Size Standard HSHR70-4 0.7 0.13 0.10 #22 #46 AWG HSHR1300-4 1.30 0.22 0.12 #8 700 AWG HSHR170-4 1.7 0.29 #4 1000 AWG 0.13 HSHR2000-4 2.00 0.33 #2 10 AWG 48 HSHR270-4 2.7 0.46 0.14 1/0 100 kcmil 1 HSHR300-4 3.0 0.8 3/0 170 kcmil 10 0.1 HSHR4700-4 4.70 0.78 300 2000 kcmil AS D412, ISO 37 ELONGATION 600% ELONGATION AFTER HEAT AGING (168 HRS. AT 10 O C) AS D2671 LONGITUDINAL CHANGE +1%, -10% LOW TEMPERATURE FLEXIBILITY (4 HRS. AT - O C) 00% SPECIFIC GRAVITY AS D792 1.1 HARDNESS (SHORE D) AS D2240 0D DIELECTRIC STRENGTH AS D149, IEC 243 00 V/Mil (20kV/mm) DIELECTRIC VOLTAGE WITHSTAND (00 V, 60HZ, 1 MIN.) UL 486D No Breakdown, 1kV 4 hrs. VOLUME RESISTIVITY AS D7 1016 ohm-cm FLUID RESISTANCE MIL-DTL-2303/1 Good Excellent FUNGUS RESISTANCE AS G21 No growth COPPER CORROSION AS D2671 No corrosion WATER ABSORPTION AS D70 0.1% ADHESIVE LAP SHEER (1 IN./MIN. AT 23 O C) AS D1002 1 psi (0.87 MPa) ADHESIVE SOFTENING POINT AS E28 90 o C± o C AS D 1000 ADHESIVE BLOCKING (30 O C) AS D1146 No blocking WATER PENETRATION S 706 No penetration after 236 hrs. of continuous immersion C6
HSFR Series Flame-Retardant Heavy-Wall Insulates and protects electrical splices and terminations High-impact and abrasion resistance Thermoplastic adhesive liner Rated for 600V, 90 C continuous use. Continuous operating temperature: - C 110 C Shrink temperature of 120 C Meets: UL and CSA standards, ANSI C119.1, Western Underground Guide Nos. 2.4, 2., MIL-DTL-2303/1, IEEE 383 Vertical Flame Test, ANSI C37.20.2, ICEA S-19-8 and NEMA insulation thickness requirements 3:1 Shrink Ratio HSFR Series Specifications I.D. I.D. Order multiple is std. pkg. Standard colour: black Nominal Wall Code Cable Size HSFR16-12-4 0.3 0.12 0.07 #14 #10 AWG HSFR12-6-4 0.1 0.16 #8 #6 AWG 0.09 HSFR6-1-4 0.7 0.24 #6 #2 AWG HSFR4-30-4 1.10 0.3 0.12 #1 3/0 AWG HSFR40-400-4 1.0 0.47 2/0 30 kcmil 0.16 HSFR00-1000-4 2.00 0.63 0 00 kcmil Standard 48 AS D412, ISO 37 ELONGATION 600% LONGITUDINAL CHANGE AS D2671 +1%, -10% SPECIFIC GRAVITY AS D792 1.2 ELONGATION AFTER HEAT AGING (168 HRS. AT 17 O C) AS D2671, ISO 37 00% AS D2671 LOW TEMPERATURE FLEXIBILITY (4 HRS. AT - O C) or splitting HARDNESS (SHORE D) AS D2240 0D OXYGEN INDEX AS D2863 27.00 FLAMMABILITY AS D2671 Flame Retardant DIELECTRIC STRENGTH AS D149 00 V/Mil (20kV/mm) DIELECTRIC VOLTAGE WITHSTAND (00 V, 60HZ, 1 MIN.) UL 486D No Breakdown, 24kV 4hrs, 1kV 4 hrs. VOLUME RESISTIVITY AS D7 1016 ohm-cm FLUID RESISTANCE MIL-DTL-2303/ Good Excellent FUNGUS RESISTANCE AS G21 No growth COPPER CORROSION AS D2671 No corrosion WATER ABSORPTION AS D70 0.2% ADHESIVE LAP SHEER (1 IN./MIN. AT 23 O C) AS D1002 1 psi (0.87 MPa) ADHESIVE SOFTENING POINT AS E28 90 o C± o C AS D 1000 ADHESIVE BLOCKING (30 O C) AS D1146 No blocking ADHESIVE WATER ABSORPTION AS D70 Less than 0.3% WATER PENETRATION S 706 No penetration after 286 hrs. of continuous immersion C7
HSC Series 3:1 Shrink Ratio Provides effective method for sealing cable ends, pipe conduit, etc. Extra thickness at the tip of the end cap prevents sharp ends of the cable from puncturing the seal Flame retardant Rated from 600/1000V, 90 degrees continuous use Shrink temperature of 120 C Resistant common fluids and solvents liner provides complete environmental protection and insulation Heat indicating lines. Continuous operating temperature: - C 110 C Heat-Shrinkable End Caps HSC Series Specifications I.D. I.D. Wall Order multiple is std. pkg. *Not UL Listed or CSA Certified Code Cable Size Nom. HSC8-4 0.1 0.16 #8 #6 AWG 0.09 2.0 100 HSC2-20 0.7 0.24 #6 #2 AWG HSC30-0 1.10 0.3 0.12 #1 3/0 AWG 3.00 HSC300-600 1.0 0.47 2/0 30 kcmil 3. 0 HSC700-1000 2.00 0.63 0 00 kcmil 3.0 0.16 HSC70 2.70 0.87 600 1000 kcmil 4.00 10 HSC300* 3.0 1.18 800 10 kcmil 4.0 HSC00* 4.70 1.7 0.17 100 00 kcmil.0 ELONGATION AS D412, ISO 37 0% ELONGATION AFTER HEAT AGING (168 HRS. AT 10 O C) 00% LONGITUDINAL CHANGE ON RECOVERY AS D2671 +1%, -10% LOW TEMPERATURE FLEXIBILITY (4 HRS. AT - O C) SPECIFIC GRAVITY AS D792 1.1 HARDNESS (SHORE D) AS D2240 0D DIELECTRIC STRENGTH AS D149, IEC 243 00 V/Mil (20kV/mm) DIELECTRIC VOLTAGE WITHSTAND (00 V, 60HZ, 1 MIN.) UL 486D No Breakdown, 1kV 4 hrs. VOLUME RESISTIVITY AS D7 1016 ohm-cm FLUID RESISTANCE MIL-DTL-2303 Good Excellent FUNGUS RESISTANCE AS G21 No growth COPPER CORROSION AS D2671 No corrosion WATER ABSORPTION AS D70 0.1% ADHESIVE LAP SHEER (1 IN./MIN. AT 23 O C) AS D1002 1 psi (0.87 MPa) ADHESIVE SOFTENING POINT AS E28 90 o C± o C AS D 1000 (mod.) ADHESIVE BLOCKING (30 O C) AS D1146 No blocking WATER PENETRATION S 706 No penetration after 236 hrs. of continuous immersion ROOM TEMPERATURE 168 hrs./40 psi TEMP. CYCLING (-40 O C TO 60 O C) 0 cycles/1 psi No leaks BURST PRESSURE 100 psi (0.70 MPa) C8
HSB Series Heat-Shrinkable Breakout Boots Boots for 2-, 3- and 4-way cable breakouts Thermoplastic adhesive liner provides complete environmental protection and insulation Meets ESI 09-11 Strain relief and mechanical protection Continuous operating temperature: - C 100 C Shrink temperature of 13 C TB TL Wall Thickness of Body Wall Thickness of Leg D d L Heat-Shrinkable Breakout Boots Order multiple is std. pkg. No. Legs HSB Series Specifications Dia. (min.) D d L TB TL Dia. (max.) Dia. (min.) Dia. (max.) (nom.) Wall Thickness of body (nom.) Wall Tickness of legs (nom.) Application Legs 600V Conducr AWG/kcmil HSB200-7-2 2 1.97 0.90 0.83 0.30 4.69 0.13 0.13 #3 300 HSB120-0-3 1.0 0.0 0.6 0.16 4.47 0.11 0.11 #8 3/0 HSB170-82-3 3 2.20 0.89 1.20 0.3 7.09 0.12 0.12 #1 600 HSB240-112-3 2.83 1.38 1.46 0.69 7.01 0.16 0.12 300 1000 HSB1-0-4 1.83 0.47 0.9 0.12 3.74 0.10 0.08 #12 2/0 HSB17-82-4 4 2.36 0.90 1.18 0. 7.9 0.16 #4 600 0.13 HSB26-120-4 3.10 1.40 1.0 0.49 9.4 0.13 3/0 1000 HSB30-138-3 3.4 1.34 1.38 0. 7.87 0.12 0.08 4/0 1000 HSB430-17-3 3 4.33 1.38 1.7 0.69 7.01 0.16 0.12 300 1000 HSB490-200-3 4.92 2.32 2.00 1.00 11.14 0.1 0.1 40 1000 HSB20-13-4 4. 3.00 1.3 0. 10.02 0.13 0.16 4/0 1000 10 ULTIMATE ELONGATION AS D412, ISO 40 600% ELONGATION AFTER HEAT AGING (168 HRS. AT 17 O C) 20% No dripping, cracking, flowing AS2671 LOW TEMPERATURE FLEXIBILITY (- O C) FLAMMABILITY AS D630 Self ext. within 1.97 sec. DIELECTRIC STRENGTH AS D2671 280 V/Mil (11kV/mm) WATER ABSORPTION AS D70 0.03% C9