FDM Medium Voltage Controller

Similar documents
How to maximize reliability using an alternative distribution system for critical loads

Power Processor - Series 700F 10KVA to 150KVA

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

Ampgard The name motor applications rely on

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

ULTRA-K Series 600K - he

Power-Sure 700. Technical Data TD158001EN. Contents

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK

AC Magnetic Starters (GE)

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)

Generator Speed Controller Model GSC 1

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

NEMA Contactor and Starter Specifications

PowerGard Series C 18-Pulse Enclosed Drive Controllers

TOSHIBA International Corp

Liebert Datawave. GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

StatiVolt. Inverter UPS Systems. Features. Contents

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System

3/4/2015. Basic relay construction. Shading coil in AC relays. Timothy L. Skvarenina and William E. DeWitt Electrical Power and Controls, 2e

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

AF91 Adjustable Frequency Drives Series B

On-Load Tap Changer Type M

and START pushbutton mounted on the enclosure and a RESET button on the front wiring is as illustrated in the wiring diagram on Page 6-3.

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

MODEL 421 Over/Under Motor Load Monitor

ECET 211 Electrical Machines and Controls

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

MEDIUM VOLTAGE COMPACT STARTER TYPE KAE

Medium Voltage Switchgear

Explosion Proof Page/Talk Paging Amplifier

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

LA-5000 SERIES LINEAR VALVE ACTUATORS

Distribution/Substation Transformer

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

Design Specifications Low Voltage Active Harmonic Filter

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

SECTION PANELBOARDS

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

Sarasota CM200 Sarasota HME900 Density Converter Electronics

FOXCART 400 MARK II OPERATION AND SERVICE MANUAL FOXTRONICS LOVE FIELD - DALLAS TEXAS MODEL PR APPROX. 550POUNDS THE POWER CART WITH MUSCLE

MAJORSINE Power Inverter

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

SECTION 16322B SUBSTATION TRANSFORMERS DRY-TYPE

PowerFlex 400 Submittal

Transformer Trainer. Electrical Power Systems PSL20. Learning Outcomes. Key Features. Key Specifications

Transformer Questions & Answers

S10N06P02P 2KVA 1PH 120/240V 16/32V Buck Boost Transformer. Descriptions


UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

S11 Adjustable Speed Drive Engineering Specification

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

General Specifications for Unit Substations

Metering Devices, Protective Relays, Software and Connectivity

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

SITRANS T measuring instruments for temperature

REDKOH INDUSTRIES SWITCH MODE POWER SUPPLY DEMO UNIT

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

SECTION AUTOMATIC TRANSFER SWITCH

Variable Frequency Drives

LST400 Ultrasonic level / open channel flow transmitter

Variable Speed Brushed DC Motor Drive

Quality Control Checklist - Design Drawings

B850 Boiler House Energy Monitor

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

Electrical Wiring: Commercial, Seventh Canadian Edition

MODEL INFORMATION. Model AWRMS TM 200. Automated Winding Resistance Measurement System

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

VMX CONFIGURED SOFT STARTER SERIES... 8 VMX-S Configured Series... 9 VMX-H Configured Series... 10

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

Page/Talk Weatherproof Wall Stations Models MLW80 and MLW85

N. TEST TEST DESCRIPTION

T S 15KVA 1PH 240/480 Transformer

Variable Transformers Product Design & Engineering Data

Transformer Questions & Answers

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

N. TEST TEST DESCRIPTION

Transcription:

1-1 LMR PLUS Product Description For over 50 years, EATON Corporation has been the industry leader in Medium Voltage Motor Control. The FDM Medium Voltage Fire Pump Controller is based on the AMPGARD controller design which incorporates Eaton's industry leading Cutler-Hammer TRITON SL Series Medium Voltage Vacuum Contactor. The SL Contactor utilizes Eaton s Cutler- Hammer vacuum interrupters that exhibit both a long electrical life and a high interruption capacity. Product Microprocessor Control The FDM Medium Voltage controller incorporates LMR Plus technology, which is an enhanced version of the original microprocessor-based LMR Series. Programming remains straightforward due to the retention of the core firmware and similar menu structure present in previous models. The use of an embedded web page for retrieving diagnostics and history reports, along with USB and Ethernet communication ports for downloading data, make the LMR Plus Series of controllers easy to troubleshoot and maintain. As well, critical information can be easily accessed and used for report generation and analysis, which aids in providing effective, reliable fire protection. LMR Plus Door Mounted Membrane Keypad displays Pressure, Voltage, Amperage, Time & Date, Frequency, Alarms & Timers and Custom Messages Alarm & Status LED Indication Last 5000 plus Messages Embedded Webpage Custom Message Display Custom Inputs & Outputs Communication via RS485 or Ethernet Information can be saved to USB Drive Optional Output Relay Boards Accessibility The LMR Plus controller section has it's own separate entrance door and is segregated from the medium voltage section. Power connections are accessible through the front of the controller and are fully isolated from the medium voltage contactor. Isolation A positive mechanical isolating switch with visible disconnect, completely grounds and isolates the contactor from the line connectors. This is achieved using a mechanically driven isolating shutter, which eliminates access to exposed high voltage components and wiring. Maintenance Since all components are front accessible, routine inspection or parts replacement is easily achieved. Design Simplicity Component-to-component direct connection reduces the number of electrical wire connections by over half, making troubleshooting faster and easier. Space Heater Included as standard is an internal space heater, which is powered from the test plug circuit. It is not necessary to apply medium voltage power to turn on the heater. Operating Devices The two external operating devices are EATON Cutler-Hammer 10250T Series NEMA Rated, Oil-Tight pushbuttons and provide the following functions: Start: Allows for local (manual) starting of the motor. The "Local Start" LED illuminates on the membrane. Stop: De-energizes the SL-400 Vacuum main run contactor. Mechanically Locked Since the medium voltage door is mechanically locked with the disconnect switch, access to the MV component section is prevented while medium voltage power is applied to the unit. Power Fuses The FDM controller incorporates fatique proof Current Limiting fuses. When properly applied, the element of the fuse will not age, become brittle or deteriorate under the most severe duty cycling. Storage space for power fuses is provided within the medium voltage section of the controller. Enclosure The FDM comes standard with a NEMA Type 2 (IEC IP11) drip-proof, powder baked finish, freestanding enclosure. A NEMA 4, 4X enclosure is available as an option. Grounding A tin-plated copper bus is provided in the incoming / load section of the FDM controller for grounding purposes. Fuses Control Transformer fuse protection is provided by primary and secondary fuses. Contactor The TRITON SL 400 contactor uses three Axial Magnetic (A-M) coils at the fixed end of the vacuum interrupters. The A-M coils establish a magnetic field within the interrupter during fault conditions. The field disperses the arc during fault current interruption, allowing the contactor to interrupt a very high fault current.

1-2 Easy Installation Current limiting fuses, contactor assembly and isolating switch assembly are easily removed from the enclosure; line and load terminals are completely accessible from the front. Wire Termination The line and load terminal connection points are located on either side of the medium voltage section and are accessible through gland plates in the bottom of the enclosure. Technical Data and Specifications Interrupt Ratings Motor Horsepower Line Voltage Interrupting Ratings 3-Phase Symmetrical MVA Approx. Weight Lbs. (Kg) 100-1000 2200-2400V 200 850 100-1250 3000V 400 (386) 100-1500 3300-3600V 400 100-2000 4160V 400 100-2250 4800V 570 100-2750 100-3000 100-3250 5500V 6000-6300V 6600-7200V 570 570 570 Altitude Ratings Fuse Interrupting Rating Contactor Short Circuit Rating Impulse Voltage Crest Line to Ground Low -3500 to -1001 meters Standard -1000 to +2000 meters 50KA Symmetrical 6000A - 1 second 60KV - 2200-7200V 80KA Asymmetrical 63KA Peak 8.7ms (0.5 Cycles) High +2001 to +4000 meters Standards & Certification The FDM Medium Voltage Fire Pump Controllers meet or exceed the requirements of Underwriters Laboratories, Underwriters Laboratories Canada, Factory Mutual, the Canadian Standards Association, New York City building code, CE mark requirements and are built to NFPA 20 standards. N. Y. C. APPROVED

1-3 Dimensions Standard Enclosure - Type NEMA 2 N. Y. C. APPROVED NOTES: 1. All enclosures finished in FirePump red. 2. Cable Entrance through bottom gland plates. 3. Standard Enclosure type NEMA 2.

1-4 Dimensions Standard Enclosure - Type NEMA 4 / 4X N. Y. C. APPROVED NOTES: 1. All enclosures finished in FirePump red. 2. Cable Entrance through bottom gland plates. 3. Standard Enclosure type NEMA 4 / 4X.

Electrical Wiring Schematic - 120V Supply / 2200-4160V Operation 1-5 LEGEND: CPT - CONTROL POWER TRANSFORMER CT - CURRENT TRANSFORMER CUST RCPT - CUSTOMER RECEPTACLE GND - GROUND ISW - ISOLATION SWITCH M - RUN CONTACTOR MSH - MANUAL START HANDLE(EMERGENCY) MICRO SWITCH PF - POWER FUSE PT - POTENTIAL TRANSFORMER RCPT- RECEPTACLE TB - TERMINAL BLOCK TR - 1.5 KVA CONTROL TRANSFORMER (240/120VAC) - INTERNAL TERMINAL BLOCK(S) N. Y. C. APPROVED Note: If 240V supply voltage is requested, a transformer will be added to the control circuit. Refer to the factory for details.

1-6 - 120V Supply / 4800-7200 Operation Electrical Wiring Schematic LEGEND: CPT - CONTROL POWER TRANSFORMER CT - CURRENT TRANSFORMER CUST RCPT - CUSTOMER RECEPTACLE GND - GROUND ISW - ISOLATION SWITCH M - RUN CONTACTOR MSH - MANUAL START HANDLE(EMERGENCY) MICRO SWITCH PF - POWER FUSE PT - POTENTIAL TRANSFORMER RCPT- RECEPTACLE TB - TERMINAL BLOCK TR - 1.5 KVA CONTROL TRANSFORMER (240/120VAC) - INTERNAL TERMINAL BLOCK(S) N. Y. C. APPROVED Note: If 240V supply voltage is requested, a transformer will be added to the control circuit. Refer to the factory for details.

1-7 Main Terminal Block: TB1 Legend Legend 8CR CPT CT CUST RCPT GND ISW M MSH PF PT RCPT SF TB TR Line Voltage Start Relay Control Power Transformer Current Transformer Customer Receptacle Ground Isolation Switch Run Contactor Mechanical Start Handle Power Fuse Potential Transformer Receptacle Secondary Fuse Terminal Block Control Transformer Internal Terminal Block(s) Catalog Number Selection Catalog Numbering System FDM Medium Voltage A = Built-in Alarm System F.P. Controllers Starting Type 30 = Across the Line B = Alarm Bell C1 = Extra Contacts "Pump Run" (Two Form-C) C2 = Extra Contacts "AC Power Failure" (Two Form-C) C3 = Extra Contacts "Phase Rev." (Two Form-C) C4 = Remote Contacts (Two Form-C) Low Reservoir C5 = Remote Contacts (Two Form-C) High Reservoir Horsepower 100 400 1000 2400 E1 = NEMA 3R - Raintight Enclosure 125 450 1200 2500 E2 = NEMA 4 - Watertight Enclosure 150 500 1250 2750 E3 = NEMA 12 - Industrial Dust Tight Enclosure 175 600 1500 3000 E5 = NEMA 4X - Stainless Steel Enclosure 200 700 1750 3250 E8 = Tropicalization 250 750 1900 3500 E9 = NEMA 4X - Painted Steel 300 800 2000 4000 E10 = NEMA 4X - 316 Stainless Steel Enclosure 350 900 2250 EX = Export Crating F = Floor Stand (Standard c/w floor mounted enclosures) Voltage F2 = Floor Stand - 2 Inch Height 60 HERTZ 50 HERTZ P7 = Low Suction Pressure Switch c/w Pilot Light A = 2200-2400V M = 2200-2400V P8 = Low Suction Shutdown (Requires P7) B = 3000V N = 3000V P10 = Pressure Transducer - Sea Water Rated C = 3300V P = 3300V R2 = Space Heater c/w Thermostat D = 3600V Q = 3600V R3 = Space Heater c/w Humidistat E = 4160V R = 4160V R4 = Low Pump Room Temperature Switch and Pilot Light F = 4800V S = 4800V X1 = Printer G = 5500V T = 5500V H = 6000V U = 6000V J = 6300V V = 6300V Language K = 6600V W = 6600V L1 = English L = 6900-7200V X = 6900-7200V L2 = French L5 = Spanish L6 = Portuguese Options Note: If the supply voltage to the controller is different than 120V 50/60Hz, the factory must be notified at time of order. Failure to indicate the proper voltage and Hz, can cause damage to the controller.

1-8 Catalog Number Selection Catalog Numbering System Catalog Number Selection Chart - 60Hz Catalog Number Selection Chart - 50Hz Catalog Number Voltage Hp Price Catalog Number Voltage Hp Price FDM-100A 2300-100 $26,050 FDM-100M 2300-100 $26,050 FDM-125A 2400V 60Hz 125 $26,050 FDM-125M 2400V 50Hz 125 $26,050 FDM-150A 150 $26,050 FDM-150M 150 $26,050 FDM-175A 175 $26,050 FDM-175M 175 $26,050 FDM-200A 200 $26,050 FDM-200M 200 $26,050 FDM-250A 250 $26,050 FDM-250M 250 $26,050 FDM-300A 300 $26,050 FDM-300M 300 $26,050 FDM-350A 350 $26,050 FDM-350M 350 $26,050 FDM-400A 400 $26,050 FDM-400M 400 $26,050 FDM-450A 450 $26,050 FDM-450M 450 $26,050 FDM-500A 500 $26,050 FDM-500M 500 $26,050 FDM-600A 600 $26,050 FDM-600M 600 $26,050 FDM-700A 700 $28,550 FDM-700M 700 $28,550 FDM-750A 750 $28,550 FDM-750M 750 $28,550 FDM-800A 800 $28,550 FDM-800M 800 $28,550 FDM-900A 900 $28,550 FDM-900M 900 $28,550 FDM-1000A 1000 $28,550 FDM-1000M 1000 $28,550 FDM-100B 3000V 60Hz 100 $26,050 FDM-100N 3000V 50Hz 100 $26,050 FDM-125B 125 $26,050 FDM-125N 125 $26,050 FDM-150B 150 $26,050 FDM-150N 150 $26,050 FDM-175B 175 $26,050 FDM-175N 175 $26,050 FDM-200B 200 $26,050 FDM-200N 200 $26,050 FDM-250B 250 $26,050 FDM-250N 250 $26,050 FDM-300B 300 $26,050 FDM-300N 300 $26,050 FDM-350B 350 $26,050 FDM-350N 350 $26,050 FDM-400B 400 $26,050 FDM-400N 400 $26,050 FDM-450B 450 $26,050 FDM-450N 450 $26,050 FDM-500B 500 $26,050 FDM-500N 500 $26,050 FDM-600B 600 $26,050 FDM-600N 600 $26,050 FDM-700B 700 $26,050 FDM-700N 700 $26,050 FDM-750B 750 $26,050 FDM-750N 750 $26,050 FDM-800B 800 $26,050 FDM-800N 800 $26,050 FDM-900B 900 $28,550 FDM-900N 900 $28,550 FDM-1000B 1000 $28,550 FDM-1000N 1000 $28,550 FDM-1200B 1200 $28,550 FDM-1200N 1200 $28,550 FDM-1250B 1250 $30,200 FDM-1250N 1250 $30,200 FDM-100C 3300V 60Hz 100 $26,050 FDM-100P 3300V 50Hz 100 $26,050 FDM-125C 125 $26,050 FDM-125P 125 $26,050 FDM-150C 150 $26,050 FDM-150P 150 $26,050 FDM-175C 175 $26,050 FDM-175P 175 $26,050 FDM-200C 200 $26,050 FDM-200P 200 $26,050 FDM-250C 250 $26,050 FDM-250P 250 $26,050 FDM-300C 300 $26,050 FDM-300P 300 $26,050 FDM-350C 350 $26,050 FDM-350P 350 $26,050 FDM-400C 400 $26,050 FDM-400P 400 $26,050 FDM-450C 450 $26,050 FDM-450P 450 $26,050 FDM-500C 500 $26,050 FDM-500P 500 $26,050 FDM-600C 600 $26,050 FDM-600P 600 $26,050 FDM-700C 700 $26,050 FDM-700P 700 $26,050 FDM-750C 750 $26,050 FDM-750P 750 $26,050 FDM-800C 800 $26,050 FDM-800P 800 $26,050 FDM-900C 900 $28,550 FDM-900P 900 $28,550 FDM-1000C 1000 $28,550 FDM-1000P 1000 $28,550 FDM-1200C 1200 $28,550 FDM-1200P 1200 $28,550 FDM-1250C 1250 $30,200 FDM-1250P 1250 $30,200 FDM-1500C 1500 $30,200 FDM-1500P 1500 $30,200

1-9 Catalog Number Selection Catalog Numbering System Catalog Number Selection Chart - 60Hz Catalog Number Selection Chart - 50Hz Catalog Number Voltage Hp Price Catalog Number Voltage Hp Price FDM-100D 3600V 60Hz 100 $26,050 FDM-100Q 3600V 50Hz 100 $26,050 FDM-125D 125 $26,050 FDM-125Q 125 $26,050 FDM-150D 150 $26,050 FDM-150Q 150 $26,050 FDM-175D 175 $26,050 FDM-175Q 175 $26,050 FDM-200D 200 $26,050 FDM-200Q 200 $26,050 FDM-250D 250 $26,050 FDM-250Q 250 $26,050 FDM-300D 300 $26,050 FDM-300Q 300 $26,050 FDM-350D 350 $26,050 FDM-350Q 350 $26,050 FDM-400D 400 $26,050 FDM-400Q 400 $26,050 FDM-450D 450 $26,050 FDM-450Q 450 $26,050 FDM-500D 500 $26,050 FDM-500Q 500 $26,050 FDM-600D 600 $26,050 FDM-600Q 600 $26,050 FDM-700D 700 $26,050 FDM-700Q 700 $26,050 FDM-750D 750 $26,050 FDM-750Q 750 $26,050 FDM-800D 800 $26,050 FDM-800Q 800 $26,050 FDM-900D 900 $26,050 FDM-900Q 900 $26,050 FDM-1000D 1000 $28,550 FDM-1000Q 1000 $28,550 FDM-1200D 1200 $28,550 FDM-1200Q 1200 $28,550 FDM-1250D 1250 $28,550 FDM-1250Q 1250 $28,550 FDM-1500D 1500 $28,550 FDM-1500Q 1500 $28,550 FDM-100E 4160V 60Hz 100 $26,050 FDM-100R 4160V 50Hz 100 $26,050 FDM-125E 125 $26,050 FDM-125R 125 $26,050 FDM-150E 150 $26,050 FDM-150R 150 $26,050 FDM-175E 175 $26,050 FDM-175R 175 $26,050 FDM-200E 200 $26,050 FDM-200R 200 $26,050 FDM-250E 250 $26,050 FDM-250R 250 $26,050 FDM-300E 300 $26,050 FDM-300R 300 $26,050 FDM-350E 350 $26,050 FDM-350R 350 $26,050 FDM-400E 400 $26,050 FDM-400R 400 $26,050 FDM-450E 450 $26,050 FDM-450R 450 $26,050 FDM-500E 500 $26,050 FDM-500R 500 $26,050 FDM-600E 600 $26,050 FDM-600R 600 $26,050 FDM-700E 700 $26,050 FDM-700R 700 $26,050 FDM-750E 750 $26,050 FDM-750R 750 $26,050 FDM-800E 800 $26,050 FDM-800R 800 $26,050 FDM-900E 900 $26,050 FDM-900R 900 $26,050 FDM-1000E 1000 $26,050 FDM-1000R 1000 $26,050 FDM-1200E 1200 $26,050 FDM-1200R 1200 $26,050 FDM-1250E 1250 $28,550 FDM-1250R 1250 $28,550 FDM-1500E 1500 $28,550 FDM-1500R 1500 $28,550 FDM-1750E 1750 $30,200 FDM-1750R 1750 $30,200 FDM-1900E 1900 $30,200 FDM-1900R 1900 $30,200 FDM-2000E 2000 $30,200 FDM-2000R 2000 $30,200 FDM-100F 4800V 60Hz 100 $26,050 FDM-100S 4800V 50Hz 100 $26,050 FDM-125F 125 $26,050 FDM-125S 125 $26,050 FDM-150F 150 $26,050 FDM-150S 150 $26,050 FDM-175F 175 $26,050 FDM-175S 175 $26,050 FDM-200F 200 $26,050 FDM-200S 200 $26,050 FDM-250F 250 $26,050 FDM-250S 250 $26,050 FDM-300F 300 $26,050 FDM-300S 300 $26,050 FDM-350F 350 $26,050 FDM-350S 350 $26,050 FDM-400F 400 $26,050 FDM-400S 400 $26,050 FDM-450F 450 $26,050 FDM-450S 450 $26,050 FDM-500F 500 $26,050 FDM-500S 500 $26,050 FDM-600F 600 $26,050 FDM-600S 600 $26,050 FDM-700F 700 $26,050 FDM-700S 700 $26,050 FDM-750F 750 $26,050 FDM-750S 750 $26,050 FDM-800F 800 $26,050 FDM-800S 800 $26,050 FDM-900F 900 $26,050 FDM-900S 900 $26,050 FDM-1000F 1000 $26,050 FDM-1000S 1000 $26,050 FDM-1200F 1200 $26,050 FDM-1200S 1200 $26,050 FDM-1250F 1250 $28,550 FDM-1250S 1250 $28,550 FDM-1500F 1500 $28,550 FDM-1500S 1500 $28,550 FDM-1750F 1750 $30,200 FDM-1750S 1750 $30,200 FDM-1900F 1900 $30,200 FDM-1900S 1900 $30,200 FDM-2000F 2000 $30,200 FDM-2000S 2000 $30,200 FDM-2250F 2250 $30,200 FDM-2250S 2250 $30,200

1-10 Catalog Number Selection Catalog Numbering System Catalog Number Selection Chart - 60Hz Catalog Number Selection Chart - 50Hz Catalog Number Voltage Hp Price Catalog Number Voltage Hp Price FDM-100G 5500V 60Hz 100 $29,950 FDM-100T 5500V 50Hz 100 $29,950 FDM-125G 125 $29,950 FDM-125T 125 $29,950 FDM-150G 150 $29,950 FDM-150T 150 $29,950 FDM-175G 175 $29,950 FDM-175T 175 $29,950 FDM-200G 200 $29,950 FDM-200T 200 $29,950 FDM-250G 250 $29,950 FDM-250T 250 $29,950 FDM-300G 300 $29,950 FDM-300T 300 $29,950 FDM-350G 350 $29,950 FDM-350T 350 $29,950 FDM-400G 400 $29,950 FDM-400T 400 $29,950 FDM-450G 450 $29,950 FDM-450T 450 $29,950 FDM-500G 500 $29,950 FDM-500T 500 $29,950 FDM-600G 600 $32,100 FDM-600T 600 $32,100 FDM-700G 700 $32,100 FDM-700T 700 $32,100 FDM-750G 750 $32,100 FDM-750T 750 $32,100 FDM-800G 800 $32,100 FDM-800T 800 $32,100 FDM-900G 900 $32,100 FDM-900T 900 $32,100 FDM-1000G 1000 $32,100 FDM-1000T 1000 $32,100 FDM-1200G 1200 $32,100 FDM-1200T 1200 $32,100 FDM-1250G 1250 $32,100 FDM-1250T 1250 $32,100 FDM-1500G 1500 $32,100 FDM-1500T 1500 $32,100 FDM-1750G 1750 $33,500 FDM-1750T 1750 $33,500 FDM-1900G 1900 $33,500 FDM-1900T 1900 $33,500 FDM-2000G 2000 $33,500 FDM-2000T 2000 $33,500 FDM-2250G 2250 $33,500 FDM-2250T 2250 $33,500 FDM-2400G 2400 $33,500 FDM-2400T 2400 $33,500 FDM-2500G 2500 $33,500 FDM-2500T 2500 $33,500 FDM-2750G 2750 $33,500 FDM-2750T 2750 $33,500 FDM-100H 6000V 60Hz 100 $29,600 FDM-100U 6000V 50Hz 100 $29,600 FDM-125H 125 $29,600 FDM-125U 125 $29,600 FDM-150H 150 $29,600 FDM-150U 150 $29,600 FDM-175H 175 $29,600 FDM-175U 175 $29,600 FDM-200H 200 $29,600 FDM-200U 200 $29,600 FDM-250H 250 $29,600 FDM-250U 250 $29,600 FDM-300H 300 $29,600 FDM-300U 300 $29,600 FDM-350H 350 $29,600 FDM-350U 350 $29,600 FDM-400H 400 $29,600 FDM-400U 400 $29,600 FDM-450H 450 $29,600 FDM-450U 450 $29,600 FDM-500H 500 $29,600 FDM-500U 500 $29,600 FDM-600H 600 $29,600 FDM-600U 600 $29,600 FDM-700H 700 $31,300 FDM-700U 700 $31,300 FDM-750H 750 $31,300 FDM-750U 750 $31,300 FDM-800H 800 $31,300 FDM-800U 800 $31,300 FDM-900H 900 $31,300 FDM-900U 900 $31,300 FDM-1000H 1000 $31,300 FDM-1000U 1000 $31,300 FDM-1200H 1200 $31,300 FDM-1200U 1200 $31,300 FDM-1250H 1250 $31,300 FDM-1250U 1250 $31,300 FDM-1500H 1500 $31,300 FDM-1500U 1500 $31,300 FDM-1750H 1750 $31,750 FDM-1750U 1750 $31,750 FDM-1900H 1900 $31,750 FDM-1900U 1900 $31,750 FDM-2000H 2000 $31,750 FDM-2000U 2000 $31,750 FDM-2250H 2250 $33,225 FDM-2250U 2250 $33,225 FDM-2400H 2400 $33,225 FDM-2400U 2400 $33,225 FDM-2500H 2500 $33,225 FDM-2500U 2500 $33,225 FDM-2750H 2750 $33,225 FDM-2750U 2750 $33,225 FDM-3000H 3000 $33,225 FDM-3000U 3000 $33,225 FDM-100J 6300V 60Hz 100 $29,600 FDM-100V 6300V 50Hz 100 $29,600 FDM-125J 125 $29,600 FDM-125V 125 $29,600 FDM-150J 150 $29,600 FDM-150V 150 $29,600 FDM-175J 175 $29,600 FDM-175V 175 $29,600 FDM-200J 200 $29,600 FDM-200V 200 $29,600 FDM-250J 250 $29,600 FDM-250V 250 $29,600 FDM-300J 300 $29,600 FDM-300V 300 $29,600 FDM-350J 350 $29,600 FDM-350V 350 $29,600 FDM-400J 400 $29,600 FDM-400V 400 $29,600 FDM-450J 450 $29,600 FDM-450V 450 $29,600 FDM-500J 500 $29,600 FDM-500V 500 $29,600 FDM-600J 600 $29,600 FDM-600V 600 $29,600 FDM-700J 700 $31,300 FDM-700V 700 $31,300 FDM-750J 750 $31,300 FDM-750V 750 $31,300 FDM-800J 800 $31,300 FDM-800V 800 $31,300 FDM-900J 900 $31,300 FDM-900V 900 $31,300 FDM-1000J 1000 $31,300 FDM-1000V 1000 $31,300 FDM-1200J 1200 $31,300 FDM-1200V 1200 $31,300 FDM-1250J 1250 $31,300 FDM-1250V 1250 $31,300 FDM-1500J 1500 $31,300 FDM-1500V 1500 $31,300 FDM-1750J 1750 $31,750 FDM-1750V 1750 $31,750 FDM-1900J 1900 $31,750 FDM-1900V 1900 $31,750 FDM-2000J 2000 $31,750 FDM-2000V 2000 $31,750 FDM-2250J 2250 $31,750 FDM-2250V 2250 $31,750 FDM-2400J 2400 $31,750 FDM-2400V 2400 $31,750 FDM-2500J 2500 $33,225 FDM-2500V 2500 $33,225 FDM-2750J 2750 $33,225 FDM-2750V 2750 $33,225 FDM-3000J 3000 $33,225 FDM-3000V 3000 $33,225

1-11 Catalog Number Selection Catalog Numbering System Catalog Number Selection Chart - 60Hz Catalog Number Selection Chart - 50Hz Catalog Number Voltage Hp Price Catalog Number Voltage Hp Price FDM-100K 6600V 60Hz 100 $29,600 FDM-100W 6600V 50Hz 100 $29,600 FDM-125K 125 $29,600 FDM-125W 125 $29,600 FDM-150K 150 $29,600 FDM-150W 150 $29,600 FDM-175K 175 $29,600 FDM-175W 175 $29,600 FDM-200K 200 $29,600 FDM-200W 200 $29,600 FDM-250K 250 $29,600 FDM-250W 250 $29,600 FDM-300K 300 $29,600 FDM-300W 300 $29,600 FDM-350K 350 $29,600 FDM-350W 350 $29,600 FDM-400K 400 $29,600 FDM-400W 400 $29,600 FDM-450K 450 $29,600 FDM-450W 450 $29,600 FDM-500K 500 $29,600 FDM-500W 500 $29,600 FDM-600K 600 $29,600 FDM-600W 600 $29,600 FDM-700K 700 $29,600 FDM-700W 700 $29,600 FDM-750K 750 $29,600 FDM-750W 750 $29,600 FDM-800K 800 $29,600 FDM-800W 800 $29,600 FDM-900K 900 $29,600 FDM-900W 900 $29,600 FDM-1000K 1000 $29,600 FDM-1000W 1000 $29,600 FDM-1200K 1200 $29,600 FDM-1200W 1200 $29,600 FDM-1250K 1250 $29,600 FDM-1250W 1250 $29,600 FDM-1500K 1500 $29,600 FDM-1500W 1500 $29,600 FDM-1750K 1750 $30,900 FDM-1750W 1750 $30,900 FDM-1900K 1900 $30,900 FDM-1900W 1900 $30,900 FDM-2000K 2000 $30,900 FDM-2000W 2000 $30,900 FDM-2250K 2250 $30,900 FDM-2250W 2250 $30,900 FDM-2400K 2400 $30,900 FDM-2400W 2400 $30,900 FDM-2500K 2500 $30,900 FDM-2500W 2500 $30,900 FDM-2750K 2750 $32,900 FDM-2750W 2750 $32,900 FDM-3000K 3000 $32,900 FDM-3000W 3000 $32,900 FDM-3250K 3250 $32,900 FDM-3250W 3250 $32,900 FDM-100L 6900-100 $29,600 FDM-100X 6900-100 $29,600 FDM-125L 7200V 60Hz 125 $29,600 FDM-125X 7200V 50Hz 125 $29,600 FDM-150L 150 $29,600 FDM-150X 150 $29,600 FDM-175L 175 $29,600 FDM-175X 175 $29,600 FDM-200L 200 $29,600 FDM-200X 200 $29,600 FDM-250L 250 $29,600 FDM-250X 250 $29,600 FDM-300L 300 $29,600 FDM-300X 300 $29,600 FDM-350L 350 $29,600 FDM-350X 350 $29,600 FDM-400L 400 $29,600 FDM-400X 400 $29,600 FDM-450L 450 $29,600 FDM-450X 450 $29,600 FDM-500L 500 $29,600 FDM-500X 500 $29,600 FDM-600L 600 $29,600 FDM-600X 600 $29,600 FDM-700L 700 $31,300 FDM-700X 700 $31,300 FDM-750L 750 $31,300 FDM-750X 750 $31,300 FDM-800L 800 $31,300 FDM-800X 800 $31,300 FDM-900L 900 $31,300 FDM-900X 900 $31,300 FDM-1000L 1000 $31,300 FDM-1000X 1000 $31,300 FDM-1200L 1200 $31,300 FDM-1200X 1200 $31,300 FDM-1250L 1250 $31,300 FDM-1250X 1250 $31,300 FDM-1500L 1500 $31,300 FDM-1500X 1500 $31,300 FDM-1750L 1750 $31,300 FDM-1750X 1750 $31,300 FDM-1900L 1900 $31,300 FDM-1900X 1900 $31,300 FDM-2000L 2000 $31,300 FDM-2000X 2000 $31,300 FDM-2250L 2250 $31,300 FDM-2250X 2250 $31,300 FDM-2400L 2400 $31,300 FDM-2400X 2400 $31,300 FDM-2500L 2500 $31,300 FDM-2500X 2500 $31,300 FDM-2750L 2750 $32,900 FDM-2750X 2750 $32,900 FDM-3000L 3000 $32,900 FDM-3000X 3000 $32,900 FDM-3250L 3250 $32,900 FDM-3250X 3250 $32,900

1-12 Catalog Number Selection Catalog Numbering - Options Catalog Number Option Selection Designation Description Price A Built-in Alarm System $350 B Alarm Bell $110 C1 Extra Contacts "Pump Run" (one N.O. std.) $90 C2 Extra Contacts "AC Power Failure" (two sets std.) $90 C3 Extra Contacts "Phase Rev." (two sets std.) $90 C4 Remote Contacts (2 Form C) Low Reservoir $90 C5 Remote Contacts (2 Form C) High Reservoir $90 CX Extra Contacts (2 Form C; Specify Function) $90 E1 NEMA 3R - Raintight Enclosure $380 E2 NEMA 4 - Watertight Enclosure $1,200 E3 NEMA 12 - Industrial Dust Tight Enclosure $25 E5 NEMA 4X - Stainless Steel Enclosure $2,000 E8 Tropicalization $275 E9 NEMA 4X - Painted Steel $1,600 E10 NEMA 4X - 316 Stainless Steel Enclosure $3,600 EX Export Crating $525 F Floor Stand (Standard c/w floor mounted enclosures) Std. F2 Floor Stand - 2 Inch Height $25 L1 Language - English N/ C L2 Language - French N/ C L5 Language - Spanish N/ C L6 Language - Portuguese N/ C LX Extra Light - (Specify Description) $90 P7 Low Suction Pressure Switch c/w Pilot Light $570 P8 Low Suction Shutdown (Requires P7) Std. P10 Pressure Transducer - Sea Water Rated $300 R1 Space Heater (120 / 220V) Std. R2 Space Heater c/w Thermostat $70 R3 Space Heater c/w Humidistat $70 R4 Low Pump Room Temperature Switch and Pilot Light $145 X1 Printer $1,075

This Page Intentionally Left Blank 1-13

FIRE PUMP CONTROLLERS Fire Pump Controller Family FD20 Limited Service Controller FD30 Across-the-Line FD40 Part Winding FD50 Primary Resistor FD60 Autotransformer FD70 WYE DELTA (Star-Delta) Open Transition FT SERIES Transfer Switches FD100 / 110 Diesel Engine Controllers FDM Medium Voltage Controllers FDF Foam Pump Controllers FDV Variable Speed Controllers FDR Residential Controllers FD80 WYE DELTA (Star-Delta) Closed Transition FDJP / JY Jockey Pump Controllers FD90 Soft Start FDAP-M Remote Alarm Panels For more information on Eaton Cutler-Hammer Fire Pump Controllers, email us at chcfirepump@eaton.com or call us at 1-877-860-7955. EATON Cutler-Hammer 2256-29th Street NE #10 Calgary, Alberta, T1Y 7G4 Canada tel: 403-717-2000 fax: 403-717-0567 www.chfire.com 2007 Eaton Corporation All Rights Reserved Printed in Canada Publication No.: