LPR WIRELESS TRANSMITTER

Similar documents
ER WIRELESS TRANSMITTER

MICROCOR ER WIRELESS TRANSMITTER

ER WIRELESS TRANSMITTER

MICROCOR WIRELESS TRANSMITTER

Field Wireless Access Point

Wireless Multi Discrete Input Transmitter Series XYR 6000, Model STXW500 Specifications

Rosemount 708 Wireless Acoustic Transmitter

Wireless Acoustic Transmitters Series XYR 5000, Model WN571 Specifications - Americas

Rosemount 702 Discrete Input Transmitter

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

Wireless Dual Discrete Input Transmitter Series XYR 5000, Model WW59x Specifications - Americas

Roxar CorrLog Wireless

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Wireless Base Radio. Wireless Transmitters

Rosemount 648 Wireless Temperature Transmitter

XYR 6000 Wireless High Level Analog Input Transmitter Model STIW600 0 to 5 Volts 1 to 5 Volts 0 to 20 ma 4 to 20 ma

Rosemount 648 Wireless Temperature Transmitter

Rosemount 705 Wireless Totalizing Transmitter

XYR 6000 Wireless Temperature/Discrete Input Transmitter Series 400 Specifications

Wireless Temperature Transmitters Series XYR 5000, Model WT5xx/WT5xxR/WT5xxT Specifications - Americas

Accutech RT10. Wireless RTD temperature field unit

Process display RIA 261

Rosemount 3051 Pressure Transmitter and Rosemount 3051CF DP Flowmeters

SmartPower Solutions. Product Data Sheet February , Rev AD

Rosemount 648 Wireless Temperature Transmitter

Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter

Accutech TC10. Wireless thermocouple temperature field unit

The Rosemount 848T Wireless Temperature Transmitter

Wireless Transmitter Gauge Pressure Models Series XYR 6000 Specifications

Wireless Transmitter Series XYR 6000 Absolute Pressure Model STAW94L 0 to 500 psia 0 to 35 bara Specifications

iant101 Zone 1 Omni Directional Antenna

Accutech DP20. Wireless differential pressure field unit

Coriolis Mass Flow Meter Model TM

Rosemount 702 Wireless Discrete Transmitter

Rosemount 248 Wireless Temperature Transmitter

Model 6081-C. Product Data Sheet PDS C/rev.D July 2010 FEATURES AND APPLICATIONS

CORRATER E-9020 DIGITAL TRANSMITTER. Reference Manual

Full Metal Variable Area Flowmeter and Counter Model BGF

Magnetic Inductive Flowmeter

Submersible pressure sensor For superior applications Model LF-1

XYR 5000 Wireless Temperature Transmitters Model WT530 Specifications - Europe

Rosemount 3101, 3102, and 3105

Accutech AP10. Wireless absolute pressure field unit

Wireless Transmitter for Contacting Conductivity

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Accutech GP10. Wireless gauge pressure field unit

Submersible pressure sensor For oils and fuels Model LF-1

Condumax CLS21 and CLS21D

Armstrong Intelligent Monitoring Installation and Operation Manual

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting

Wireless Pressure Transmitter Differential Pressure Models Series XYR 6000 Specifications

User Guide. Keysight N6850A Broadband Omnidirectional Antenna

WIRELESS TRANSMITTER for ph and ORP

Model E-9020 Corrater Digital Transmitter

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Submersible pressure sensor For water and wastewater Model LW-1

Level Measurement Continuous level measurement Radar transmitters

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Temperature Input Module for Zone 1 Series 9482/32

RoamAbout Outdoor Antenna Site Preparation Guide

Electro-Magnetic Flowmeters COPA-XE

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Field indicator for current loops with HART communication Models DIH50, DIH52

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

Accutech FL10. Wireless float level field unit

WIRELESS TRANSMITTER for ph and ORP

WRZ-RMT10K-0 Wireless Remote Temperature Transmitter

OPTIWAVE 1010 Technical Datasheet

Specification and Model Selection Guide. Introduction 34-XY /14/07. Figure 1 XYR6000 Temperature Transmitters

Electrodynamic Velocity Sensor

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

Rosemount 248 Wireless Temperature Transmitter

Condumax CLS15 and CLS15D

Tower Light with Wireless Switch Control Box

Condumax CLS15 and CLS15D

IP26 Series Current to Pneumatic Converter

This Antenna Basics reference guide includes basic information about antenna types, how antennas work, gain, and some installation examples.

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.

Operating Manual. isolate501

CSI 9420 Wireless Vibration Transmitter

Coriolis Massflowmeter

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Rosemount TGU 65 Tank Radar Gauge, Still Pipe Antenna

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

SITRANS T measuring instruments for temperature

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Technical Information Condumax CLS21D/CLS21

Sure Cross Radio Certifications

Field indicator for current loops with HART communication Models DIH50, DIH52

SPECIAL SPECIFICATION 6574 Low Power Wireless Modem

AN0509 swarm API Country Settings

Rosemount 248 Wireless Temperature Transmitter

General Specifications

TABLE OF CONTENTS APPENDIX A... 8 APPENDIX B... 9 APPENDIX C... 12

General Specifications

Guide. Installation. Wilson Electronics, Inc. In-Building Wireless Amplifi er. Contents:

Transcription:

LPR WIRELESS TRANSMITTER LPR-310 / LPR-320 The LPR 310 / LPR 320 wireless transmitter is designed for online corrosion monitoring of water systems in electrically hazardous areas. Instantaneous corrosion rate measurements are made using linear polarization resistance (LPR) measurement technology. The LPR 310 / LPR 320 has the same patented high frequency measurement on two electrodes for compensation of solution resistance as the E 9020 wired transmitter, providing the highest accuracy and widest range of operation*. The most common use of the transmitter is for corrosion rate and pitting tendency in water systems. However with a set galvanic electrode, the transmitter may be operated in a galvanic monitor mode, which is particularly useful in high pressure water injection systems for detection of low levels of oxygen in the parts per billion range (ppb), where conventional dissolved oxygen meters cannot be used. The LPR 310 / LPR 320 power module has a typical life of 3 years and is hazardous location certified to allow change out in the hazardous area. Typical wireless range is 1000 ft. (300 m) or 1500 ft. (450 m) in optimal conditions with a clear line of sight from transmitter to transmitter or transmitter to gateway/management station, with multiple hops permissible from any transmitter back to its gateway/management station. The LPR 310 / LPR 320 is available with the option of WirelessHART 7 or ISA100 Wireless communications protocol for seamless integration with Emerson, Yokogawa, and numerous other wireless process systems. For outline of a Cosasco Wireless System, and details of each product, see Cosasco Wireless System ISA100 and Cosasco Wireless System WirelessHART7 data sheets. Specification WirelessHART 7 Communication Option ISA100 Wireless Wireless Range (clear line of sight) 1000 ft (300 m) 1500 ft (450 m) Transmitter Battery Life 3 Years 3 Years Wireless Devices Supported Per Gateway Up to 100 Up to 500 Network Type Inherently Mesh Mesh or Star Topology System Integration Certifications Emerson, Endress & Hauser, Siemens, and ABB Wireless Networks Hazardous Area Locations (Class I, Zone 1) Yokogawa, Honeywell, and GE Wireless Networks Hazardous Area Locations (Class I, Zone 1) *For reference, see ASTM G96 90(2001) e1 Standard Guide for On Line Monitoring of Corrosion in plant equipment (Electrical and Electrochemical Methods).

Operating Specifications Measurement Ranges: Corrosion Rate: 0 to 200 mpy 0 5,000 µm/y 0 5 mm/y Physical Specifications Enclosure Rating: IP66 Materials: Housing: 6061 T6 Aluminum with Polyester Enamel over Epoxy Primer or 316 Stainless Steel Imbalance (Pitting Index): 0 to 200 pitting units Potential Measurement: 0 to 2 volts Potential Input Impedance: >20 Mohms Galvanic/Current Measurement: 0 to 500 μa Power supply 7.2 V Lithium Power Module Power Module life: 3 years (Typical) Hazardous Area Location Certified. (replacement okay in hazardous locations). Resolution: 0.1% of ranges 0 1%, 1 10%, 10% 100% of full scale Operating Range: See graph next page Data Transmit Rate 10 to 60 minutes (15 minutes for 3 year battery life) Weight Aluminum Housing: Stainless Steel Housing: Dimensions See below 7.5 lbs. (3.4 kg) with Lithium Power Module Installed 15.3 lbs. (6.9 kg) with Lithium Power Module Installed Communication: 2.4 GHz IEEE 802.15.4. WirelessHART 7 Protocol (CWT 9020 0 0) ISA100 Wireless Protocol (CWT 9020 0 2) Ambient Temperature Range 40C to +70C ( 40F to +158F) Antenna Integrated Omni directional Antenna Impedance: 50 Ω Gain: +2dBi Maximum SWR: 3:1 Maximum radio power output: 10 mw Product Certifications Optional Pole or Wall Mounting Metal Bracket for direct wall mount and adjustable U Bolt mounting for 2 pipe size vertical or horizontal pole mounting. Probe Mounting Directly to probe via Probe Adapter (P/N 710973 or P/N 710972). For remote locations probe can be directly connected to LPR via a probe to instrument cable). Telecommunication Compliance All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification. Cosasco is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage. The LPR is currently certified with the governmental agencies of Angola, Azerbaijan, Australia, Canada, China, Colombia, Ecuador, European Union, Egypt, India, Indonesia, Kazakhstan, Kuwait, Malaysia, Mexico, Oman, Qatar, Russia, Saudi Arabia, Thailand & Tobago, UAE, United States and Venezuela. Additional country approvals are in currently in progress and will be posted as soon as certification is verified. Please contact Cosasco or visit our website for the latest country certifications. FCC and Industry Canada (IC) This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions. This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons.

ATEX Certification Ex d [ib] Class I, Zone 1, IIC, T4, Gb, Ta = 40C to +70C North American Certifications FM AEx d [ib] Class I, Zone 1, IIC, T4, Ta = 40C to +70C FMc Ex d [ib] Class I, Zone 1, IIC, T4, Ta = 40C to +70C IEC Ex Certification IEC Ex d [ib], Class I, Zone 1, IIC, T4, Gb, Ta = 40C to +70C All certifications based on IP66 enclosure and for use only with Power Module P/N 748400 Operating Range for Model LPR 310 /LPR 320

Dimensions 11.58 in (294 mm) 6.38 in (162 mm) Ø 4.40 in (112 mm) 7.59 in (193 mm) Transmitter Dimensions in inches, front view

Ordering Information for ISA100 Wireless LPR Wireless Transmitter ISA100 Wireless Model CWT-9020 Description LPR-320 Wireless Transmitter with ISA100 Radio 2 2.4 GHz ISA100 - Integral Antenna CWT-9020 0 2 Typical Order Number System Requirements Field Wireless Management Station See R Y410 Field Wireless Management Station Data Sheet. Field Wireless Access Point See R Y510 Field Wireless Access Point Data Sheet. LPR Probes See standard LPR Probes Data Sheets for ordering information. Probe Adapters Retractable/Fixed Probes P/N 710973 Retrievable Probes P/N 710972 Cables (Transmitter to Probe Cable with Transmitter Mounting Bracket) Retractable Retractable LPR Remote Mounting Kit P/N 710971 L (2 ft. up to 6 ft., in 1 ft. increments). Retrievable Part No. Description 748497 Retrievable LPR-320 Remote Mounting Kit Code Cable Type 3 Retrievable (armored) 2500 PSI 4 Retrievable (unarmored) 2500 PSI 5 Retrievable (armored) 10,000 PSI 6 Retrievable (unarmored) 10,000 PSI Code Cable Length L Length in Feet (15 ft max) 748497 3 5 Typical Order Number

Accessories Cosasco Wireless Extender Model Description MWT-3905-WE Cosasco Wireless Extender (includes mounting bracket) 2 2.4 GHz ISA100 Wireless - Integral Antenna MWT-3905-WE 0 2 Typical Order Number 7.2 V Lithium Power Module P/N 748400 LPR 320 Installation Kit ISA100 Wireless P/N 702406 CWT ISA (includes Wireless Field Tool for transmitter configuration) Ordering Information for WirelessHART 7 LPR Wireless Transmitter WirelessHART 7 Model CWT-9020 Description LPR-310 Wireless Transmitter with WirelessHART7 Radio 0 2.4 GHz WirelessHART7 - Integral Antenna CWT-9020 0 0 Typical Order Number System Requirements Wireless Gateways See R 1420 or R 1410 Data Sheets. Checkmate DL W Wireless Configurator P/N Checkmate DL W LPR Probes See standard LPR Probes Data Sheets for ordering information. Probe Adapters Retractable/Fixed Probes P/N 710973 Retrievable Probes P/N 710972

Cables (Transmitter to Probe Cable with Transmitter Mounting Bracket) Retractable Retractable LPR Remote Mounting Kit P/N 710971 L (2 ft. up to 6 ft., in 1 ft. increments). Retrievable Part No. Description 748497 Retrievable LPR-310 Remote Mounting Kit Code Cable Type 3 Retrievable (armored) 2500 PSI 4 Retrievable (unarmored) 2500 PSI 5 Retrievable (armored) 10,000 PSI 6 Retrievable (unarmored) 10,000 PSI Code Cable Length L Length in Feet (15 ft max) 748497 3 5 Typical Order Number Accessories Cosasco Wireless Extender Model Description MWT-3905-WE Cosasco Wireless Extender (includes mounting bracket) 0 2.4 GHz Wireless HART7 - Integral Antenna MWT-3905-WE 0 0 Typical Order Number 7.2 V Lithium Power Module P/N 748400 LPR 310 Installation Kit WirelessHART7 P/N 702406 CWT Cosasco 11841 Smith Avenue Santa Fe Springs, CA 90670, USA Tel: 1 562 949 0123 Email: sales@cosasco.com Web Site: www.cosasco.com Rohrback Cosasco Systems, Inc. All rights reserved The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described wherein or their use or applicability. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. Rohrback Cosasco Systems Corrosion Monitoring Equipment is manufactured and sold under one or more of the following US Patents: 4138878, 4238298, 4338563, 4514681, 4537071, 4587479, 4605626, 4625557, 4755744, 4839580, 4841787, 4882537 5243297 Bulletin #307-H Rev. Date: 03/16/2016