INDEPENDENT CONTROL OF MULTI-TERMINAL VOLTAGE SOURCE CONVERTER-BASED HIGH-VOLTAGE DIRECT CURRENT LINK ANALYZING FOR DIRECT CURRENT FAULTS

Similar documents
A New Network Proposal for Fault-Tolerant HVDC Transmission Systems

Fundamental Concepts of Dynamic Reactive Compensation. Outline

Real and Reactive Power Control by using 48-pulse Series Connected Three-level NPC Converter for UPFC

U I. HVDC Control. LCC Reactive power characteristics

29 Level H- Bridge VSC for HVDC Application

CONVERTERS IN POWER VOLTAGE-SOURCED SYSTEMS. Modeling, Control, and Applications IEEE UNIVERSITATSBIBLIOTHEK HANNOVER. Amirnaser Yazdani.

High Voltage DC Transmission 2

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

Improvement of Rotor Angle Stability and Dynamic Performance of AC/DC Interconnected Transmission System

Introduction to HVDC Transmission. High Voltage Direct Current (HVDC) Transmission

Power Quality enhancement of a distribution line with DSTATCOM

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

ATC s Mackinac Back-to-Back HVDC Project: Planning and Operation Considerations for Michigan s Eastern Upper and Northern Lower Peninsulas

IMPORTANCE OF VSC IN HVDC

Design Strategy for Optimum Rating Selection of Interline D-STATCOM

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Reactive Power and AC Voltage Control of LCC HVDC System with Digitally Tunable Controllable Capacitors

ANALYSIS OF MULTI-TERMINAL HVDC TRANSMISSION SYSTEM FEEDING VERY WEAK AC NETWORKS

ELEMENTS OF FACTS CONTROLLERS

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

Investigation of D-Statcom Operation in Electric Distribution System

B.Tech Academic Projects EEE (Simulation)

VSC Based HVDC Active Power Controller to Damp out Resonance Oscillation in Turbine Generator System

Operation of a Three-Phase PWM Rectifier/Inverter

Intelligence Controller for STATCOM Using Cascaded Multilevel Inverter

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 07, 2014 ISSN (online):

Voltage Control and Power System Stability Enhancement using UPFC

ANFIS based 48-Pulse STATCOM Controller for Enhancement of Power System Stability

SIMULATION OF D-Q CONTROL SYSTEM FOR A UNIFIED POWER FLOW CONTROLLER

Joe Warner, Electric Power Industry Conference (EPIC), November 15, 2016 Advances in Grid Equipment Transmission Shunt Compensation

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Analysis the Modeling and Control of Integrated STATCOM System to Improve Power System

Power Upgrading of Transmission Line by Injecting DC Power in to AC Line with the help of ZIG-ZAG Transformer

Designing Of Distributed Power-Flow Controller

AEIJST - July Vol 3 - Issue 7 ISSN A Review of Modular Multilevel Converter based STATCOM Topology

HVDC CAPACITOR COMMUTATED CONVERTERS IN WEAK NETWORKS GUNNAR PERSSON, VICTOR F LESCALE, ALF PERSSON ABB AB, HVDC SWEDEN

Improved Transient Compensation Using PI-SRF Control Scheme Based UHVDC For Offshore Wind Power Plant

Dynamic Stability Improvement of Power System with VSC-HVDC Transmission

A NOVEL APPROACH ON INSTANTANEOUS POWER CONTROL OF D-STATCOM WITH CONSIDERATION OF POWER FACTOR CORRECTION

Interline Power Flow Controller: Review Paper

Copyright 2012 IEEE. Paper presented at 2012 IEEE Workshop on Complexity in Engineering 11 June, Aachen,

Enhancement of Voltage Stability & reactive Power Control of Distribution System Using Facts Devices

VSC Transmission. Presentation Overview. CIGRE B4 HVDC and Power Electronics HVDC Colloquium, Oslo, April LCC HVDC Transmission

Implementation of D-STACTOM for Improvement of Power Quality in Radial Distribution System

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

REDUCTION OF THD IN POWER SYSTEMS USING STATCOM

Simulation Study of a Monopole HVDC Transmission System Feeding a Very Weak AC Network with Firefly Algorithm Based Optimal PI Controller

PUBLICATIONS OF PROBLEMS & APPLICATION IN ENGINEERING RESEARCH - PAPER CSEA2012 ISSN: ; e-issn:

Dynamic Performance Evaluation of an HVDC Link following Inverter Side Disturbances

Design and Simulation of Fuzzy Logic controller for DSTATCOM In Power System

Power Quality and the Need for Compensation

Power Converter Systems

Harmonic Immunity And Power Factor Correction By Instantaneous Power Control Of D-STATCOM

Acknowledgements Introduction p. 1 Electric Power Quality p. 3 Impacts of Power Quality Problems on End Users p. 4 Power Quality Standards p.

Power Transmission of AC-DC Supply in a Single Composite Conductor

Enhancement of Power Quality in Distribution System Using D-Statcom

ASPECTS OF REAL-TIME DIGITAL SIMULATIONS OF ELECTRICAL NETWORKS

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

MATLAB Implementation of a Various Topologies of Multilevel Inverter with Improved THD

DC Chopper Based Test Circuit for High Voltage DC Circuit Breakers

FUZZY CONTROLLED DSTATCOM FOR HARMONIC COMPENSATION

A NEW APPROACH FOR MODELING COMPLEX POWER SYSTEM COMPONENTS IN DIFFERENT SIMULATION TOOLS

Enhancement of AC System Stability using Artificial Neural Network Based HVDC System

Design of Shunt Active Power Filter by using An Advanced Current Control Strategy

Voltage Source Converter Modelling

IMPROVEMENT OF POWER QUALITY USING CUSTOM POWER DEVICES

IJEETC. InternationalJournalof. ElectricalandElectronicEngineering& Telecommunications.

A Generic Point-to-Point MMC-VSC System for Real-Time and Off-Line Simulation Studies

The University of Nottingham

Size Selection Of Energy Storing Elements For A Cascade Multilevel Inverter STATCOM

A cost effective hybrid HVDC transmission system with high performance in DC line fault handling

Performance of Indirectly Controlled STATCOM with IEEE 30-bus System

Fuzzy Logic Based Control of Wind Turbine Driven Squirrel Cage Induction Generator Connected to Grid

USE OF HVDC MULTI TERMINAL OPTIONS FOR FUTURE UPGRADE OF THE NATIONAL GRID

Increasing Dynamic Stability of the Network Using Unified Power Flow Controller (UPFC)

factors that can be affecting the performance of a electrical power transmission system. Main problems which cause instability to a power system is vo

New Converter Topologies for High-Voltage Dc Converters. Prof. Ani Gole University of Manitoba, Canada

HVDC Transmission Using Artificial Neural Networks Based Constant Current and Extension Angle Control

New HVDC Interaction between AC networks and HVDC Shunt Reactors on Jeju Converter Stations

[Kumar*, 4.(7): July, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Static Synchronous Compensator (STATCOM) for the improvement of the Electrical System performance with Non Linear load 1

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

Highgate Converter Overview. Prepared by Joshua Burroughs & Jeff Carrara IEEE PES

Modelling of VSC-HVDC for Slow Dynamic Studies. Master s Thesis in Electric Power Engineering OSCAR LENNERHAG VIKTOR TRÄFF

Steady State Fault Analysis of VSC- HVDC Transmission System

Chapter-5 MODELING OF UNIFIED POWER FLOW CONTROLLER. There are a number of FACTS devices that control power system

Effects and Mitigation of Post-Fault Commutation Failures in Line-Commutated HVDC Transmission System

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

FACTS devices in Distributed Generation

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

Real and Reactive Power Coordination for a Unified Power Flow Controller

Experience with Connecting Offshore Wind Farms to the Grid

OVERVIEW OF SVC AND STATCOM FOR INSTANTANEOUS POWER CONTROL AND POWER FACTOR IMPROVEMENT

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

Multiconverter Unified Power-Quality Conditioning System: MC-UPQC T.Charan Singh, L.Kishore, T.Sripal Reddy

POWER UPGRADATION AND POSSIBILITY OF SMALL POWER TAPPING FROM COMPOSITE AC- DC TRANSMISSION SYSTEM

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

Power System Reliability and Transfer Capability Improvement by VSC- HVDC (HVDC Light )

HVDC High Voltage Direct Current

Transcription:

Vol 4, Issue 4, 2016 ISSN - 2347-1573 Review Article INDEPENDENT CONTROL OF MULTI-TERMINAL VOLTAGE SOURCE CONVERTER-BASED HIGH-VOLTAGE DIRECT CURRENT LINK ANALYZING FOR DIRECT CURRENT FAULTS KARISHMA BENAZEER SHAIK 1 *, NOOR CHESHMA PHATAN 2, SREEDEVI JINKALA 2, JAWAHAR ANNABATTULA 1 1 Department of Electrical and Electronics Engineering, Koneru Lakshmaiah University, Guntur, Andhra Pradesh, India. 2 Power Systems Division, Central Power Research Institute, India. Email: benazeerkarishma@yahoo.in ABSTRACT Received: 22 August 2016, Revised and Accepted: 24 August 2016 The ability to control the active power, reactive power, alternating current (AC) voltage, and direct current (DC) voltage has provided the optimum utilization of the power system. This paper presents the modeling of multi-terminal voltage source converter (VSC)-based high-voltage direct current (HVDC) system. The reactive power by a particular terminal can be maintained constant or controlled. The DC bus voltage and AC voltage are controlled by separate terminal; the active power flow is maintained by another terminal. Each terminal can control up to two parameters depending on the requirement. Each controlled parameter requires tuning of PI controller gains to achieve satisfactory performance. The analysis of VSC-based HVDC is carried out using vector control. The multi-terminal response of a VSC-HVDC system during load changes, power reversal, and line to ground fault on DC cable are analyzed. Simulation is carried out in RSCAD/RTDS software, and the performance of the system is presented. Keywords: Alternating current voltage controller, Direct current fault, Direct current voltage controller, Multiterminal, Neutral point diode clamped converter, Voltage source converter-high-voltage direct current. INTRODUCTION The common direct current (DC) voltage made parallel connections easy to build and control for a multi-terminal voltage source converter (VSC)-based high-voltage direct current (HVDC) system when compared to the current source converter or conventional thyristor-based HVDC systems as shown in Fig. 1. VSC-based HVDC systems are finding an important place in the transmission systems. Some of the advantages of VSC-HVDC that made this technology more attractive are: 1. Due to its modular, compact, and standardized construction, the converter can be easily and rapidly installed/commissioned at the desired site [1]. 2. Commutation with VSCs permits black start [2]. 3. VSC technology provides rapid and independent control of active and reactive power [3] without need of extra compensating equipment. The reactive power can be controlled independent of active power [1-4]. 4. The VSC-HVDC system connection for a weak AC network or to a network where the short circuit level is low, i.e. absence of generation source [4,5]. Due to the advantages, the VSC-based HVDC transmission suits very well in certain applications. The applications are: 1. Remote islands can be supplied by submarine cables using VSC-HVDC transmission. An example of this application is the Gotland Island system. 2. Offshore application using VSC technology is flexible and new units can be easily added if the expansion of the farm is desired. 3. Mainly due to right-of-way and land constraints, the compact VSC-based HVDC technology represents a feasible solution to feed the city centers. Thus, the underground transmission circuits are placed to bring in power as well as to provide voltage support. This process is realized without compromising reliability, and it is an economical way to power supply. Other applications of VSC-based HVDC transmission system is asynchronous interconnection. The control block diagram shown in Fig. 2 can control four parameters active power, reactive power, DC voltage, and alternating current (AC) voltage. The method of control depends on whether the VSC-HVDC is utilized for unified power flow control (UPFC) or static synchronous compensator (STATCOM). If it is used as a UPFC [6], then to derive the reference quadrature component of current (IQref), AQR in Table 1 is used, and if it is used as an STATCOM, then AC-AVR is used for stiff voltage at that terminal. Both DC-AVR and active power control (APR) are used in case of UPFC or STATCOM for the direct component of current (IDref). To control the active power flow, APR is used [7]. This paper is organized in different sections. Section 2 explains the RTDS software used for simulation purpose. Section 3 briefly describes the VSC-HVDC system and the performance of the proposed system. Finally simulation results are explained in Section 4. Conclusions are discussed at the end of the paper. REAL TIME DIGITAL SIMULATOR - RTDS A wide range of studies are possible with the modular fully digital power system simulator RTDS. It is a combination of hardware and software, which permits the simulation of power systems in real time. Simulations performed by the RTDS simulator are of electromagnetic transient s class. RSCAD A software package that comprises the graphical user interface used by the RTDS simulator. The functions available are file management, circuit layout, operator s console, and data analysis. Compiler The compiler is a software program which takes picture data input representing the user-defined circuit from RSCAD and produces the executable code required by the RTDS to perform the simulation of the output. Giga processor card (GPC) The GPC is a computational unit which is used for solving the overall network solution. The GPC contains RISC processors. The GPC is used to solve the network solution or various component models. Signal exchange between the GPC cards is accomplished through a common backplane for which all cards within a rack are connected.

Fig. 1: Multi-terminal voltage source converter-based high-voltage direct current system Fig. 2: Block diagram of controllable parameters for an alternating current/direct current converter Giga bit transceiver workstation interface card (GTWIF) It is a printed circuit card whose primary function is to handle communication between the rack and the host computer. The communication medium used is a standard Ethernet-based local area network. GTWIF also synchronize the calculations performed by the processor cards within a rack. It also provides inter-rack communication. RACK A rack is a basic module of RTDS hardware that includes a card cage and backplane structure to GPC and GTWIF. Larger simulators can be created by connecting multiple racks. Advantages of RTDS simulator Expandability, conducting multiple studies simultaneously, interactive runtime interface. Multiple software installations, small time-step subnetwork (<3 µs with which frequencies more than that of processors frequencies can be accurately tested) [8]. SYSTEM DESCRIPTION VSC-HVDC system As shown in Fig. 3, the three terminals of VSC-based HVDC system described in Table 2 is connected between three AC systems of two different frequencies. AC systems of rectifier terminal 1 and 3 at inverter terminal 2 are represented by the Venin s equivalent of 93 and 44 kv, respectively. The rectifier and inverter terminals are connected Active power control Reactive power control DC voltage control AC voltage control AC current control Pulse width modulation Error Table 1: Terminology for controls AC: Alternating current, DC: Direct current AC system Terminal 1 Terminal 2 Terminal 3 Converter Transformer (Y/Y) VSC HVDC system DC cable Table 2: System data Rectifier Inverter Rectifier Rectifier Inverter DC V: 60 kv, Power: 200 MW 100 km APR AQR DC AVR AC AVR ACR PWM Reference value Actual value 93 kv, 60 Hz 44 kv, 50 Hz 93 kv, 60 Hz 93/44 kv, 100 MVA 44/44 kv, 100 MVA AC: Alternating current, DC: Direct current, VSC: Voltage source converter, HVDC: High voltage direct current by a DC cable. The phase reactors smoothen the current. The capacitors are used for voltage support and harmonic attenuation. The circuit 2

inside the rectifier box is simulated in small step time simulation and interfaced to the main circuit through the interface transformer. The rectifier side circuit of VSC-HVDC consists of interfacing transformer, smoothing reactor, VSC Bridge, and the DC line as shown in Fig. 4. The rectifier side of terminal 3 also has a similar configuration. The inverter side configuration is the mirror image of this. The VSC configuration used is having multi-level neutral point diode clamped converter (NPC). NPC NPC has been widely accepted among the multi-level converters. The desired output voltage levels can be achieved with a few numbers of capacitors and switches per phase, which is, therefore, more economical and reliable. The size of the capacitor is less since it is designed only for half the DC link voltage. The sinusoidal voltage with minimum or no filtering components can be achieved with optimum frequency of the converter switches [9]. Controls for multi terminals This paper implements DC-AVR and APR controls for obtaining reference IDref at terminal 1 and to obtain IQref, AC-AVR is used. At terminal 2, DC-AVR is used to obtain IDref and AC-AVR is used to derive IQref. At terminal 3, DC-AVR and AQR are used to obtain IDref and IQref, respectively. This makes the optimum utilization of the power system making two terminals as UPFC and the other terminal as STATCOM. Voltage margin and power reversal Voltage margin as shown in Fig. 5 is required for the terminal to supply power [10]. The intersection point of the terminal characteristics and the change in characteristics and intersection point by resetting the voltage margin and the reversal of power flow can be observed as shown in Fig. 6a and b, respectively. Controls at terminal 1 As shown in Fig. 7, the APR and AC voltage controller output is given to the inner current control loop. The Direct and Quadrature components of voltages obtained by the inner current controller [11] are used to generate firing pulses for the switches present in rectifier bridge circuit through pulse width modulation technique. Fig. 3: Line diagram of voltage source converter-based high-voltage direct current Fig. 4: Rectifier circuit of voltage source converter-based high-voltage direct current Fig. 5: Power-voltage characteristics of three terminals 3

a b Fig. 6: (a and b) Power flow characteristics of three terminals Fig. 7: Block diagram showing control at terminal 1 The actual power is compared with the reference power, and the error is passed through a PI controller which gives the command to the lower limit of the PI controller in DC voltage controller, which controls the active power at the terminal. In the AC voltage controller, the actual AC voltage is compared with reference value and the error is passed through PI controller, which gives IQref for the inner current controller. Controls at terminal 3 The controls, as shown in Fig. 8 at terminal 3, have the actual reactive power comparison with the reference reactive power, and the error is passed through a PI controller, which gives IQref for the inner current controller. IDref for the inner current loop is similar to the DC voltage controller at terminal 1. Controls at terminal 2 From Fig. 9, the DC voltage controller and AC voltage controller (Fig. 9) have a combination of controls from terminal 3. Inner current control loop The controls discussed above are outer controllers, and the ACR is the inner controller shown in Fig. 10, which is the inner current control loop. Where the currents derived from the PI controllers are compared with the d-q components of the transformer primary side currents. 4

Fig. 8: Block diagram showing controls at terminal 3 Fig. 9: Block diagram showing controls at terminal 2 Fig. 10: Inner current control loop The reference d-q component voltages for the modulation index of the control system are derived from this inner current loop [12]. SIMULATION RESULTS The simulation of VSC-HVDC is studied for steady state condition, sudden load change without change in reference value and change in reference value, power reversal, and DC fault condition. The normal operating condition of VS-HVDC system is simulated with ±60 kv and 200 MW. Steady state AC voltages of 93 and 44 kv are maintained at rectifiers and inverter, respectively. Case 1: Load at terminal 2 without change in reference power A load of 50 MW at 0.95 power factor is added at terminal 2 without the change in reference power at terminal 1, described in Table 3. Since there is no change in power and to maintain the DC link power at 200 MW power at terminal 3 is maintained. The power required by the load is supplied from terminal 2 and this can be observed from Fig. 11. The reactive power controller at terminal 3 is maintained irrespective Table 3: Terminology PSRCL Real power at terminal 1 PSRCL1 Real power at terminal 3 PSRCR Real power at terminal 2 QSRCL Reactive power at terminal 1 QSRCL1 Reactive power at terminal 3 QSRCR Reactive power at terminal 2 of load changes since reference reactive power is not changed. The AC and DC voltages are constant during load changes and the change in power is due to change in current and can be observed from Fig. 12. Case 2: Load at terminal 2 with change in reference power During this case, the change in reference power at terminal 1 is 50 MW, and now, the DC link power is 150 MW. To maintain the DC link power, the 50 MW power required by the load is supplied by terminal 2. The reactive power at terminal 3 is maintained. 5

Fig. 11: Powers at terminal 1, 2, and 3 during case 1 Fig. 12: Terminal 2 voltages, currents, and powers during case 1 These changes can be observed from Fig. 13. To maintain AC and DC voltages by the controllers, the decrease in AC current and DC cable currents can be observed from Fig. 14 for the required amount of power at terminal 2. 6

Fig. 13: Powers at terminal 1, 2, and 3 during case 2 Fig. 14: Voltages, currents, and powers at terminal 2 during case 2 7

Case 3: Power reversal Instead of giving voltage reference for terminals 1 and 3, now the DC voltage reference is given to terminal 2 for power reversal case as shown in Fig. 6b. The terminals 1 and 3 are absorbing power, and now, they are inverters and terminal 2 is giving power. The 50 MW of power is absorbed by each inverter side terminal. The reactive Fig. 15: Powers at terminal 1, 2, and 3 during case 3 8

power at terminal 3 is maintained by AQR. These can be observed from Fig. 15. During power reversal, the DC and AC voltages are maintained by the respective controllers. The currents through the cable are interchanged from positive to negative and vice versa. The change in AC currents for the change of power can be seen from Fig. 16. Fig. 16: Voltages, currents, and powers at terminal 2 during case 3 9

Case 4: Load at terminal 2 during power reversal DC voltage at terminal 2 gives a DC link power of 100 MW. To maintain this DC link power without the change of reference value at terminal 1, the extra amount of power required by the load is supplied by the terminal 2. Now, the amount of power delivered by the terminal 2 is 150 MW. The reactive power controller at terminal 3 maintains at its Fig. 17: Powers at terminal 1, 2, and 3 during case 4 10

value. These changes can be observed from Fig. 17. The required change in AC and DC currents to maintain voltages can be observed from Fig. 18. Case 5: DC fault condition Once the system is reached to this steady state condition; DC fault is created at the positive pole by pushing the fault button for fault duration of 60 ms. The DC link capacitors are grounded at the converter. Capacitor discharging state Initially, when the fault occurs, the DC link capacitor discharges through the DC cable [13], thus resulting in large inrush of DC current and rapid decrease in DC voltage and a substantial increase in AC current [14,15]. The switches of the VSC have to be blocked immediately to protect them from the resulting over current as shown in Fig. 19. AC feeding over current stage When the DC capacitor voltage falls, the large DC current flows through the DC cable and the freewheel diodes effectively shortened. The absence of DC smoothing reactor in the VSC-HVDC results in the generation of large over current. The discharge of voltage results in AC current. Fig. 18: Voltages, currents, and powers at terminal 2 during case 4 11

Table 4: PI controller gains and time constants Terminals Outer controllers (PI) Inner controllers (PI) ID axis IQ axis ID axis IQ axis Gain Time constant Gain Time constant gain Time constant Gain Time constant 1 7.5 0.01 10 0.001 0.18 0.2 0.18 0.2 2 7.5 0.01 10 0.001 0.18 0.2 0.18 0.2 3 7.5 0.01 10 0.001 0.18 0.2 0.18 0.2 Fig. 22: Alternating current at converter bridge Fig. 19: Single voltage source converter after blocking of switches Fig. 23: Direct current cable Fig. 20: Capacitor recharging phase CONCLUSION Fig. 24: Current through the capacitor Fig. 21: Voltage across the capacitor Capacitor recharging stage As the DC cable current decays, the current in the capacitors changes which effectively recharges the capacitor as shown in Fig. 20. Capacitor discharging condition, AC overcurrent and cable current, and capacitor current can be observed from the Figs. 21-24, respectively. In this paper, design and analysis of the VSC-HVDC system are carried out. Active power, reactive power, DC voltage, and AC voltage controllers are implemented at rectifier and inverter as per requirement. Steady state simulation of VSC-HVDC system is achieved by modeling the detail system in RSCAD/RTDS software. The multi-level NPC converter in this study has reduced large capacitor requirement at the DC link. The high blocking capacity of the switch in the converter protected the system during positive pole to ground fault. The system is observed with the modeled controllers and tuned PI controller gains and time constants as shown in Table 4. This work can be analyzed for larger size wind farms connected to the grid. REFERENCES 1. Sood V. HVDC Facts Controllers Application of Static Converters in Power Systems. Boston: KLUWER Academic Publishers; 2004. 2. Bahrman MP. Overview of HVDC Transmission. Atlanta, GA: IEEE Power System Exposition, Conference Proceedings, October 12

29-November 1; 2006. 3. Bahrman MP. HVDC Transmission Overview. Chicago, IL: IEEE Power Energy Society Transmission Distribution Conference Proceedings, April 21-24; 2008. p. 1-7. 4. Flourentzou N, Agelidis V, Demetriades G. VSC-based HVDC power transmission systems, An overview. IEEE Trans Power Electron 2009;24:592-602. 5. Meier S. Novel Voltage Source Converter based HVDC Transmission System for Off-Shore Wind Farms. Stockholm, Sweden: Royal Institute of Technology; 2005. 6. Chida T, Sato Y, Sugawara J, Morikawa R, Tamura Y, Irokawa S. Simulation study of unified power flow controller. IEEJ Transactions on Power and Energy. Vol. 117. 1997. p. 960-6. 7. Sakamoto K, Yajima M, Ishikawa T, Sugimoto S, Sato T, Abe H. Development of a control system for a high-performance selfcommutated AC/DC converter. IEEE Transactions on Power Delivery. Vol. 13. 1998. p. 225-32. 8. RTDS Technologies Inc. Hardware Manual of RTDS TM. Canada: RTDS Technologies Inc.; 2012. 9. RTDS Technologies Inc. VSC Small Time - Step Modeling Manual of RTDS TM. Canada: RTDS Technologies Inc.; 2006. 10. Yazdani A, Iravani R. A generalized state-space averaged model of the three-level NPC converter for systematic DC-voltage-balancer and current-controller design. IEEE Transactions on Power Delivery. Vol. 20. 2005. p. 1105-14. 11. Sood VK. HVDC Transmission Power Conversion Applications in Power Systems. John Wiley & Sons, Asia, IEEE PRESS. 2009. p. 14. 12. Schauder C, Mehta H. Vector analysis and control of advanced static VAR compensators. IEEE Proceedings Conference. Vol. 140. 1993. p. 299-306. 13. Rafferty J, Xu L, Morrow DJ. DC fault analysis of VSC based multiterminal HVDC systems. IET 10 th International Conference Proceedings on AC DC Power Transmission. 2012. p. 1-6. 14. Rafferty J, Morrow DJ, Xu L. Analysis of VSC-based HVDC system under DC faults. IEEE Industrial Electronics Society, IECON 2013-39 th Annual Conference. 2013. p. 459-64. 15. Subramanyam Reddy RS. Harmonic reduction and power transmission enhancement in a grid interface of wind power using shunt-connected FACTS device. Int Electric Eng J 2015;6(8):1994-8. 13