Model R8001. Instructionn Manual. Laser Distance Meter. reedinstruments. www. com

Similar documents
LazerTape 160. Lazer Distance Meter TRIPLETT. Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Laser Distance Finder Extech DT500

Laser Distance Finder Extech DT500

DISTANCE METER

USER MANUAL. Laser Distance Meter MODELS DT40M, DT60M, and DT100M

? 2 max 3 4 min

AX-DL100 - Laser Distance Meter

ed560l Laser Distance Meter User Manual

1. Brief Introduction

1 Symbols. 4 Foreseeable misuse Do not use the device as a laser pointer. Do not use the device in explosive or aggressive environments.

X2 LASER DISTANCE METER. Operating instruction

Table of Contents. Makita LD050P 1

DE EN FR IT ES RU PL DA NL NO SV

Table of Contents. Stabila LD 320 1

INSTRUCTION MANUAL MODEL SAS RS-7 LASER DISTANCE METER

421D. Users Manual. Distance Meter

User s Manual. hand-held laser distance meter

Model R2002. Instruction Manual. Infrared Thermometer. reedinstruments www.

Leica DISTO TM E7400x The original laser distance meter

P10 LASER DISTANCE MEASURE. IMPORTANT: Read before Using

User Manual InfraRed Thermometer With Laser Pointer and High/Low Alarms Model IR270

Manual Laser Range Finder PCE-LDM 44

Instruction Manual. Self-Leveling Cross-Line Laser Level Model No and

IR-829 Infrared Thermometer User Manual

Operator's Manual. 10-in. Digital Multi-function LEVEL with Laser Trac. Model No

Digital Target Locator. The smart way to measure.

STABILA laser distance measurer: The right product for every use.

Model. Instruction Manual. Digital ph Pen. reedinstruments. REED Instruments

Leica DISTO TM E7500. The original laser distance meter

Leica DISTO TM E7100i The original laser distance meter

Operating Instructions GEMINI R

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

User Manual. Safety Instructions. Contents. Symbols used. Use of the instrument. Prohibited use. English. Safety Instructions

Visit us at

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297

Leica DISTO D3 The Worlds Most Innovative and Smallest Hand Held Laser Distance Measurer

INSTRUCTION MANUAL INF Fax: (503)

Installation Instructions SKU# , Rated Voltage V~ 50Hz

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

DE EN FR ECOLINE EL 609 BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI EXACTLY WHAT YOU NEED.

OPERATIONS MANUAL DP-110 IN-DUCT DIGITAL PSYCHROMETER TABLE OF CONTENTS

PD-I. English Français Español Português

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

Geo EasyTrack Auto Tracking System for Line Lasers

Bedienungsanleitung Instruction Manual. testo 815 Sound Level Meter

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

USER MANUAL. UV AB Light Meter. Model UV505. Additional User Manual Translations available at

Pipe Laser Model No Instruction Manual

R/C SMD Tweezers Multimeter Model RC200

DW033 / DW055E User Manual

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

USER GUIDE. IR Thermal Scanner. Model IRT500

Laser LAX 300 G. Operating instructions

P20 Zoom Flash Zoom Flash P20 P20 Zoomblitz Flash con zoom P20 Flash externo P20 Flash Zoom P20

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

Laser distance measurers for real professionals: accurate, quick and reliable results for all applications

CONTENTS MS2033A. 1.Introduction Safety Information...01

Energate Foundation Meter Data Collector Installation Guide

Thermo Plus Bluetooth-enabled Thermo-Hygro Monitor Model: RAR213HG USER MANUAL

INSTRUCTION MANUAL LM192 LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

Infrared Gun. Perfect For. Easy To Use. Features. Get Professional Results Every Time! Battery Installation. Model: IN1022

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

Ricoh XR Speedlite 300P

Laser LA-4P. Operating instructions

Nuclear Associates

Photometer Maintenance Guide

ASSEMBLY AND INSTALLATION INSTRUCTIONS

IMPORTANT: Read Before Using. Operating/Safety Instructions 8601-RL

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

PD 5. English Français Español

3x Magnification. Digital Zoom to 6x. CAUTION: Do not point Infrared Emitter directly into eye at close range.

EXAMINER+ Manual V.1. ARROWHEAD FORENSICS Strang Line Road Lenexa, Kansas PHONE FAX

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Infrared Thermometer Remote Temperature Measurement ( Non-Contact ) 1327 INSTRUCTION MANUAL

LSC Radio User Guide Information and Guidelines

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Pocket Size Digital Multimeter with USB Model: A & A

600A Clamp Meters w/tightsight Display

FLS 90 floor line laser

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

USER GUIDE. Mini InfraRed Thermometer with Laser Pointer MODEL 42500

Laser LAX 300. Operating instructions

Owner s Manual BL

DVM1190 DIGITAL MULTIMETER

PLR 25. Robert Bosch GmbH Power Tools Division Leinfelden-Echterdingen Germany (2011.

Not for Reproduction

Thermo Bluetooth-enabled Thermometer. Model: EMR211 USER MANUAL CONTENTS

INSTRUCTION MANUAL LM195 LED LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

INDEX POWER SOURCES OPERATING ON BATTERY BATTERY REPLACEMENT

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

Multifunction AC/DC Voltage Tester

CLAMP-ON METER 670. User Manual

USER MANUAL. LUX/FC Light Meter. Model LT505. Additional User Manual Translations available at

User s Manual. Ground Resistance Clamp On Tester MODEL

Owner s Manual PMR 446 Handheld transceiver G5

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Non-contact Forehead IR Thermometer

Transcription:

Model R8001 Laser Distance Meter Instructionn Manual reedinstruments com

Table of Contents Safety... 3 Features... 3 Specifications...3-4 Instrument Description... 5 Operating Instructions...6-10 Measuring Range... 6 Target Surfaces... 6 On and Off... 6 Clear Button... 6 Reference Level Setting... 6 Backlight... 7 Distance Unit Setting... 7 Single Distance Measurement... 7 Continuous (Tracking)/Max & Min Measurement... 7 Addition/Subtraction... 8 Area Measurement... 8 Volume Measurement... 8 Indirect Measurement... 9 Three Point Measurement... 9 Measurement Storage... 10 Troubleshooting... 10 Care... 10 Battery Replacement... 10 reedinstruments com 2

Safety Read and follow manual instructions before using this instrument Do not use this instrument outside the stated limits Do not deactivate the safety systems or remove explanatory and hazard labels Do not open this instrument with any tools unless specifically indicated to do so in this manual Do not modify or change the product in any way Do not use accessories from other manufacturers without the approval of CEM Technology Do not aim directly towards the sun Laser Class 2 products: Do not stare into the laser beam or direct it towards others Features Area and volume calculations Indirect measurement using Pythagoras Addition/subtraction continuous measurement Min/Max and distance tracking Display illumination and multi-line display Function beep Multifunctional end pieces Specifications Measuring Range: Measuring accuracy: Measuring units: Laser Class: 0.05 to 50m* (0.16 to 164 ft*) ±1.5mm** (±0.06in**), up to 10m (2σ, standard deviation) Meters, inches, feet Class II continued... reedinstruments com 3

Laser Type: 635nm, <1mW Dust/Splash proof: IP 54 Record count: 20 Keyboard Type: Super soft-touch (Long life) Operating Temperature: 0 C to 40 C (32 F to 104 F) Storage Temperature: -10 C to 60 C (14 F to 140 F) Laser auto off: 0.5 min Auto power off: 3 min of inactivity Power Consumption: Up to 4,000 measurements Power Supply: Two AAA (1.5V) batteries Dimensions: 115 x 48 x 28mm Weight: 135g * Use a target plate to increase the measurement range during daylight or if the target has poor reflection properties. ** In favourable conditions (good target surface properties, room temperature) up to 1 conditions, such as intense sunshine, poorly reflecting target surface or high temperature variations, the deviation over distances above 10 m (33ft) can increase by ± 0.15mm/m (± 0.0018in/ft). reedinstruments com 4

Instrument Description 1. On/Measure button 2. Area/Volume button 3. Indirect Measurement button 4. Single/Continuous Distance Measurement button 5. Plus (+) button 6. Minus (-) button 7. Storage button 8. Reference button 9. Backlight/Unit button 10. Clear/Off button Display Description 1. Laser is active 2. Reference level (front) 3. Reference level (rear) 4. Measurement indicator Area measurement Volume measurement Indirect measurement Indirect (second) measurement 5. Single distance measurement 6. Battery status 7. Memory history, call up values 8. Instrument error warning 9. Continuous/Max & Min measurement 10. Primary display 11. Secondary display 12. Previous result reedinstruments com 5

Operating Instructions Measuring Range The measuring range is limited to 50m. If measuring at night or dusk and the target is in a dark area, the measuring range will be increased (unless you use a target plate). To increase the measurement range during daylight or if the target has poor reflection properties you can use a target plate. Target Surfaces Measuring errors can occur when measuring toward colorless liquids (e.g. water) or dust free glass, Styrofoam or similar semi-permeable surfaces. Aiming at high gloss surfaces may deflect the laser beam and lead to measurement errors. When measuring against non-reflective and dark surfaces the measuring time may increase. On and Off The On/Measure button turns the instrument and laser on. Press the Clear button for a few seconds to turn the instrument and laser off. The instrument switches off automatically after three minutes of inactivity. Clear Button This button cancels the last action and clears the display. Reference Level Setting The default reference setting is from the rear of the instrument. Press the Reference button to take the selection from the top of the instrument. A special beep sounds whenever the reference setting is changed. After re-starting the instrument the reference returns automatically to the default setting. reedinstruments com 6

Backlight Press the Backlight/Unit button to turn the backlight on and off. Distance Unit Setting Hold down the Backlight/Unit button for a few seconds to change the unit of measure. Continue to press the button to toggle between all units of measure. You can choose between m, ft, in, and ft + in. Single Distance Measurement Press the On/Measure button to activate the laser. Press the button again to trigger the distance measurement. The measured value will be displayed immediately. Continuous (Tracking)/Max & Min Measurement The continuous measurement function (tracking) is used for the transferring of measurements (ie: from construction plans). In continuous measurement mode, the measuring tool can be moved to the target, whereby the measured value is updated approx. every 0.5 seconds. The corresponding max and min values are displayed dynamically in the first and second line. For example, the user can move from a wall to the required distance, while the actual distance can be read continuously. For continuous measurement, press the Max/Min button until the indicator for continuous measurements appears on the display. Press it again or press the On/Measure button to stop the function. The function is terminated after 100 continuous measurements. reedinstruments com 7

Addition/Subtraction Press the Plus button to add the current measurement to the previous measurement. Press the On/Measure button to add the second measured value; the result will automatically display. Press the Minus button to subtract the current measurement from the previous measurement. Press the On/Measure button for the result to be shown in the summary line and the previous measurement will be shown in the second line. Press the Clear button for the last step to be cancelled. Press the Max/Min button to return to single distance measurement mode. Area Measurement Press the Area/Volume button once to enter Area Measurement mode. The icon will appear on the display to confirm you are in the correct mode. Press the On/Measure button to take the first measurement (ie: length), press the On/Measure button again to take the second measurement (ie: width). Then the area/surface is automatically calculated and displayed in the summary line on the display. The previous measurement will be shown in the second line. Volume Measurement Press the Area/Volume button twice to enter Area Measurement mode. The icon will appear on the display to confirm you are in the correct mode. Press the On/Measure button to take the first measurement (length), press the On/Measure button again to take the second measurement (width), press the On/Measure button again to take the third measurement (height). Then the volume is automatically calculated and displayed in the summary line on the display. The previous measurement will not be shown. reedinstruments com 8

Indirect Measurement This is used to determine a distance using two auxiliary measurements. Press the Indirect Measurement button once, the icon will appear on the display. Aim at the highest point and press the On/Measure button to take the measurement. Holding the instrument as horizontal as possible press and hold the On/Measure button to trigger continuous measurement, the horizontal line is measured and shown in the summary and secondary lines. Three Point Measurement Press the Indirect Measurement button twice, the icon will appear on the display. Aim at the highest point (1) and press the On/Measure button to trigger the measurement. Holding the instrument as horizontal as possible press and hold the On/Measure button to trigger continuous measurement and sweep the laser up and down over the ideal target point (2), press the On/Measure button again to confirm the value. Aim at the lower point (3) and press the On/Measure button to trigger the measurement. The results are shown in the summary and secondary lines at the same time. reedinstruments com 9

Measurement Storage Press the Storage button to view the previous 20 records (measurements or calculated results). Use the + and buttons to navigate the records. Troubleshooting Code Cause Corrective measure 204 Calculation error Repeat procedure 208 Received signal too weak/ Use target plate measurement time too long/ Distance >50m 209 Received signal too strong Target too reflective (use target plate) 252 Temperature too high Cool down instrument 253 Temperature too low Warm up instrument 255 Hardware error Switch meter on/off several times* *If error persists contact REED Instruments at info@reedinstruments.com Care Do not immerse the instrument in water. Wipe off dirt with a damp, soft cloth. Do not use aggressive cleaning agents or solutions. Handle the instrument as you would a telescope or camera. Battery Replacement This instrument uses 2 AAA (1.5V) alkaline batteries. The batteries need to be replaced when the battery symbol flashes on the display. Remove the batteries before any long period of non-use to avoid the possibility of corrosion. Only use alkaline batteries. 1. Remove battery compartment cover. 2. Insert new batteries, respecting the correct polarity. 3. Close the battery compartment cover. reedinstruments com 10

Notes reedinstruments com 11

Notes reedinstruments com 12