Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Data Sheet

Similar documents
Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Data Sheet

Level Plus. RefineME Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Level Plus. SoCLEAN Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Level Plus. CHAMBERED Data Sheet. Magnetostrictive Liquid Level Transmitters with Temposonics Technology

Temposonics. Magnetostrictive Linear Position Sensors. ET Start/Stop Data Sheet. High operating temperature Compact sensor housing ATEX certified

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Temposonics. Magnetostrictive Linear Position Sensors. ER IO-Link Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EH IO-Link Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL IO-Link Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Start / Stop Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology

Temposonics. Magnetostrictive Linear Position Sensors. EH Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. RT4 SSI Data Sheet. Redundant SSI output High temperature rod IP68 ingress protection

Temposonics. Magnetostrictive Linear Position Sensors. EP2 Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. GB Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ER SSI Data Sheet

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. TH SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series Flexible MH Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

I am the new generation. Temposonics. Magnetostrictive Linear Position Sensors. R-Series V RP Profinet RT & IRT Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ER IO-Link Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP / EL Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP2 IO-Link Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ER Start / Stop Data Sheet

I am the new generation. Temposonics. Magnetostrictive Linear Position Sensors. R-Series V RH Profinet RT & IRT Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP2 Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ER SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. TH SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP2 CANopen Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. EP2 SSI Data Sheet

Magnetostrictive Level Transmitter

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX, IECEx)

HAWK Magnetostrictive Level Transmitter (CSA/FM, ATEX)

Temposonics. Magnetostrictive Linear Position Sensors. DATA SHEET A-Series Linear Encoder. The Measurable Difference

OBSOLETE A. For 24-hour Technical Assistance Call

Temposonics GENERATION THE NEW I AM. Magnetostrictive Linear Position Sensors. R-Series V RH EtherNet/IP Data Sheet

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Liquid Level Sensors. M-Series Magnetostrictive Sensors

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series MS Analog/Digital Data Sheet NOW WITH DIGITAL OUTPUT AVAILABLE!

Liquid Level Transmitter Model MC420 Analog Output

Level Plus Liquid-Level Sensors With Temposonics Technology

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable)

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

AT200 External Mount Magnetostrictive Level Transmitter

Temposonics. Magnetostrictive Position Sensors. G-Series Linear Position Sensor Analog and Digital Pulse Outputs. Product Specification E

Temposonics. E-Series Model ER. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. Analog and Start/Stop Outputs.

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products

MS Connector: (Voltage or Current Output) Pin No. Extension Cable Function. Wire Color. MS Connector: (Start/Stop or PWM) Wire Color WIRING: + A

Magnetostrictive Level Transmitter

Temposonics LF & RF Summary

Level Measurement Continuous level measurement Radar transmitters

Level Plus Liquid-Level Sensors With Temposonics Technology

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Non-Submersible Industrial Pressure Transducer

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Coriolis Massflowmeter

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology

7250 Series HR Digital Stik

Temposonics. M-Series Analogue/PWM Tester. User s Manual. Absolute, Non-Contact Position Sensors. Document Part Number Revision B

Coriolis Massflowmeter

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

DREXELBROOK. IMPULSE Series Guided Wave Radar (TDR) for Total Level and Volumetric Measurements. Easy to install, Easy to use. Dependable performance

Coriolis Mass Flow Meter Model TM

D E S C R I P T I O N F E A T U R E S A P P L I C A T I O N S. The Enhanced Jupiter Magnetostrictive level transmitter

Process display RIA 261

DREXELBROOK. IMPULSE Series. Guided Wave Radar (TDR) Easy to install, Easy to use. Dependable performance. The New Impulse Guided Wave Radar

Rosemount 3101, 3102, and 3105

Accutech DP20. Wireless differential pressure field unit

OPTIFLUX 5000 Technical Datasheet

Submersible pressure sensor For oils and fuels Model LF-1

Servo Gauge 854 XTG. Global Experience. Locally Applied. Cut costs, not repeatability.

Submersible pressure sensor For water and wastewater Model LW-1

IP26 Series Current to Pneumatic Converter

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Submersible pressure sensor For superior applications Model LF-1

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

TIDALFLUX 2300 F Technical Datasheet

MEGGITT MOBREY LTD. MOBREY SQUING Vibrating fork liquid level switch. Product data sheet IP202

Coriolis Massflowmeter

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TMU. Coriolis Mass Flow Meter. for liquids and gas

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

Accutech GP10. Wireless gauge pressure field unit

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

K-BAND RADAR FOR LIQUIDS

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

VITO LT. Global Experience. Locally Applied. A dependable choice.

Flow Measurement SITRANS F M

Transcription:

Level Plus Magnetostrictive Liquid Level Transmitters with Temposonics Technology Tank SLAYER 3-IN-1 Measurement Inherent Accuracy ±1 mm API Temperature Corrected Volumes No Scheduled Maintenance or Recalibration Hazardous Area Certified

TEMPOSONICS TECHNOLOGY Temposonics Technology is the manner in which MTS applies the principles of magnetostriction to create a reliable position measurement system for use in industrial environments. Inside the sensor a torsional strain pulse is induced in a specially designed magnetostrictive waveguide by the momentary interaction of two magnetic fields. One field comes from a moving magnet, which passes along the outside of the transducer tube, and the other field is generated from a current pulse which is applied to the waveguide. The interaction between these two magnetic fields produces a strain pulse which travels at sonic speed along the sensor waveguide, until the pulse is detected at the head of the transducer. The position of the moving magnet is precisely determined by measuring the elapsed time between the application of the current pulse and the arrival of the strain pulse. As a result, MTS is able to create a reliable position measurement system that is capable of providing an accurate and repeatable measurement. Magnet field of current pulse Movable position magnet Mechanical strain pulse Strain (torsion) pulse converter Magnet field of position magnet Fig. 1: Time-based magnetostrictive position sensing principle Magnetostrictive sensing element (waveguide) Current interrogation pulse TANK SLAYER The Level Plus Tank Slayer liquid level transmitter satisfies the demand for an accurate and robust liquid-level sensor with unsurpassed flexibility to meet most process application conditions. The Tank Slayer transmitter provides 3-in-1 measurement using one process opening for product level, interface level, and temperature measurements. Once the transmitter is installed and calibrated there is no requirement for scheduled maintenance or recalibration. Set it and forget it! Features: 3-in-1 Measurement Product Interface Temperature No Scheduled Maintenance or Recalibration Inherent Accuracy ±1mm Integral Display Intrinsically Safe API Temperature Corrected Volumes Applications: Inventory Control Bulk Storage Custody Transfer Markets: Petroleum and Petrochemical LPG terminals Food and Beverage Standard FM 3610 Rating Class I, Div. 1, Groups A, B, C, and D T4 Class I, Zone 0/1, AEx ia IIC T4 Ta= -50 to 71 C: IP65 C22.2 No. 157 Class I, Div. 1, Groups A, B, C, and D T4 Class I, Zone 0/1, Ex ia IIC T4 Ta= -50 to 71 C: IP65 Fig. 2: Example of product and interface level measurement EN 60079-11:2012 FM14ATEX0068X II 1/2 G Ex ia IIC T4 Ta= -50 to 71 C: IP65 IEC 60079-11:2011 IECEx FMG 14.0032 II 1/2 G Ex ia IIC T4 Ga/Gb Ta= -50 to 71 C: IP65 I 2 I

TECHNICAL DATA Level Output Measured variable Output signal /Protocol Order length Inherent Accuracy Product level and interface level Modbus RTU, DDA Flexible hose: 1575 mm (62 in.) to 22000 mm (866 in.) ±1 mm (0.039 in.) Repeatability 0.001% F.S. or 0.381 mm (0.015 in.) * (any direction) Temperature Output Measured variable Temperature accuracy Electronics Input voltage Fail safe Reverse polarity protection Average and multipoint temperatures ±0.2 ºC (0.4 ºF) range -40 ºC (-40 ºF) to -20 ºC (-4 ºF)*, ±0.1 ºC (0.2 ºF) range -20 ºC (-4 ºF) to 70 ºC (158 ºF)*, ±0.15 ºC (0.3 ºF) range 70 ºC (158 ºF) to 100 ºC (212 ºF)*, ±0.5 ºC (0.9 ºF) range 100 ºC (212 ºF) to 105 ºC (221 ºF) 10.5 to 28 Vdc High, Full scale for digital Series diode EMC Stage 1: Line-to-ground surge suppression; IEC 61000-4-5, IEC 61326-3-2 Stage 2: Line-to-line and line-to-ground transient suppressors; IEC 61000-4-4, IEC 61326-3-2 Environmental Enclosure rating Humidity Operating temperatures Vessel pressure NEMA Type 4X, IP65 0 to 100% relative humidity, non-condensing Electronics: -40 C (-40 F) to 71 C (160 ºF) Sensing element: -40 C (-40 F) to 125 C (257 F) Temperature element: -40 C (-40 F) to 105 C (221 F) Flexible Hose: 260 psi (18 bar) Materials Wetted parts: 316L stainless steel Non-wetted parts: 316L stainless steel, Epoxy coated aluminum Field Installation Housing dimensions Mounting Flexible hose Wiring Connections Electrical Connections Single and Dual Cavity NEMA Type 4X Display Measured variables Single cavity: 145 mm (5.7 in.) W x by 127 mm (5 in.) D x 109 mm (4.3 in.) H Dual cavity: 117 mm (4.6 in.) W x by 127 mm (5 in.) D x 206 mm (8.1 in.) H Stainless steel single cavity: 178 mm (7.1 in.) W x by 135 mm (5.3 in.) D x 153 mm (6 in.) H NEMA Type 4X: 87 mm (3.4 in.) W x by 124 mm (4.9 in.) D x 132 mm (5.2 in.) H 1 in. Adjustable MNPT or BSPP fitting, Flange mount 4-wire shielded cable or twisted pair, Daniel Woodhead 6-pin male connector, 4570 mm (180 in.) integral cable with pigtail ¾ in. FNPT conduit opening, M20 for ATEX/IECEx version 1/2 in. FNPT conduit opening Product level, interface level and temperature * Whichever is greater Contact factory for longer lengths. Contact factory for specific temperature ranges. Contact factory for alternative materials. Order length equals the measurement range plus the inactive zone. I 3 I

TECHNICAL DRAWING 145 mm (5.7 in.) 114 mm (4.5 in.) FNPT or M20 152 mm (6.0 in.) 305 mm (12 in.) 1 in. MNPT or BSPP adjustable fitting Welded flange 1,575 mm (62 in.) to 22,000 mm (866 in.) TRANSMITTER INACTIVE ZONE REFERENCE Length Inactive Zone <7.6 m (25 ft.) 76 mm (3 in.) 7.6 m to 12.2 m (25 to 40 ft.) 97 mm (3.8 in.) 12.3 m to 20 m (26 to 72 ft.) 120 mm (4.7 in.) I 4 I

ORDER CODE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 L P T a b c d e f g h i j k l m n o p a Sensor model L P T Tank Slayer Level Transmitter b Output M Modbus D DDA c Housing type A NEMA housing w/cable B NEMA housing w/terminal C NEMA housing w/connector D Single cavity with display E Dual cavity with display L SS single cavity w/display d Electronics mounting 1 Standard e Sensor pipe M Flexible, 7/8 OD tube w/bottom fixing eye N Flexible, 7/8 OD tube w/bottom fixing weight P Flexible, 7/8 OD tube w/bottom fixing magnet S Flexible, 7/8 OD tube w/o bottom fixing hardware f Materials of construction (Wetted parts) 1 316L stainless steel Note: Contact factory for other materials g Process connection type 1 NPT adjustable 2 BSPP adjustable 6 150 lb. welded RF flange 7 300 lb. welded RF flange 8 600 lb. welded RF flange A PN16, DIN 2572 welded flange B PN40, DIN 2572 welded flange C PN64, DIN 2572 welded flange D PN100, DIN 2572 welded flange h Process connection size B 1 in. (DN25) D 2 in. (DN50) E 2 1/2 in. (DN65) F 3 in. (DN80) G 4 in. (DN100) H 5 in. (DN125) J 6 in. (DN150) X None i Number of DT s (Digital Thermometer) 0 None 1 One DT 5 5 DTs K Twelve DTs M Sixteen DTs j DT Placement F Evenly spaced per API C Custom X None k Notified body C CEC (FMC) E ATEX F NEC (FM) I IEC X None l Protection method I IS X No approval (Continued on next page) I 5 I

ORDER CODE 1 2 3 4 5 6 7 8 9 10 11 L P T a b c d e f g h i 12 13 14 15 16 17 18 19 20 21 22 j k l m n o p m Gas group A Group A B Group B C Group C D Group D 1 IIA 2 IIB 3 IIC X None n Unit of measure M Metric - Millimeters U US customary - Inches o Length (no decimal spaces) X X X X X Flexible sensor pipe: 62 to 866 in. (code as 06200 to 86600 X X X X X Flexible sensor pipe: 1575 to 22000 mm (code as 01575 to 22000) p S Special Standard Product ORDERING NOTE Accessories such as floats, cables, and displays have to be ordered separately. All accessories are shown in the Accessories Catalog (551103). I 6 I

FREQUENTLY ORDERED ACCESSORIES Additional options available in our Accessories Catalog 551103 General Notes: 1. Be sure that the float specific gravity is at least 0.05 less than that of the measured liquid as a safety margin at ambient temperature. 2. For interface measurement: A minimum of 0.05 specific gravity differential is required between the upper and lower liquids. 3. When the magnet is not shown, the magnet is positioned at the center line of float. 4. Drawings contained in this document are for reference only. Contact the factory for engineering drawings. Long-gauge floats Pressure Temp. Magnet offset Specific gravity Material Part number 76 mm (3 in.) 88 mm (3.44 in.) C LMagnet 92 mm (3.6 in.) dia. 28 mm (1.1 in.) dia. 29.3 bar (425 psi) 149 C (300 ºF) Yes 0.54 SS 252961-2 0.65 Hastelloy-C 252961-4 0.93 SS 252962-2 0.93 Hastelloy-C 252962-4 Long-gauge floats Pressure Temp. Magnet offset Specific gravity Material Part number 127 mm (5.01 in.) 70 mm (2.76 in.) max. dia. 28 mm (1.1 in.) dia. 22.4 bar (325 psi) 149 C (300 ºF) No 0.66 SS 201232-2 0.70 Hastelloy-C 201232-4 Controlling design dimensions are always in metric units I 7 I

Document Part Number: 551688 Revision A (EN) 07/2015 LOCATIONS USA MTS Systems Corporation Sensors Division 3001 Sheldon Drive Cary, N.C. 27513, USA Tel. +1 919 677-0100 Fax +1 919 677-0200 info.us@mtssensors.com JAPAN MTS Sensors Technology Corp. 737 Aihara-machi, Machida-shi, Tokyo 194-0211, Japan Tel. + 81 42 775-3838 Fax + 81 42 775-5512 info.jp@mtssensors.com GERMANY MTS Sensor Technologie GmbH & Co. KG Auf dem Schüffel 9 58513 Lüdenscheid, Germany Tel. + 49 2351 9587-0 Fax + 49 2351 56491 info.de@mtssensors.com CHINA MTS Sensors Room 504, Huajing Commercial Center, No. 188, North Qinzhou Road 200233 Shanghai, China Tel. +86 21 6485 5800 Fax +86 21 6495 6329 info.cn@mtssensors.com LEGAL NOTICES MTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation in the United States; MTS SENSORS and the MTS SENSORS logo are trademarks of MTS Systems Corporation within the United States. These trademarks may be protected in other countries. All other trademarks are the property of their respective owners. Copyright 2015 MTS Systems Corporation. No license of any intellectual property rights is granted. MTS reserves the right to change the information within this document, change product designs, or withdraw products from availability for purchase without notice. Typographic and graphics errors or omissions are unintentional and subject to correction. Visit for the latest product information. Product change notification alerts are available through the MTS Product Change Management System; register at /PCMS. FRANCE MTS Systems SAS Zone EUROPARC Bâtiment EXA 16 16/18, rue Eugène Dupuis 94046 Creteil, France Tel. + 33 1 58 4390-28 Fax + 33 1 58 4390-03 info.fr@mtssensors.com ITALY MTS Systems Srl. Sensor Division Via Diaz,4 25050 Provaglio d Iseo (BS), Italy Tel. + 39 030 988 3819 Fax + 39 030 982 3359 info.it@mtssensors.com