Analog Oscilloscope Selection Guide

Similar documents
SAFETY TERMS AND SYMBOLS

OSCILLOSCOPES. Oscilloscopes CS-5400 SERIES CS-5400/5450 FEATURES OUTLINE CS-5400

SAFETY TERMS AND SYMBOLS

PHUONGLAI.COM SAFETY TERMS AND SYMBOLS. 1. PRODUCT INTRODUCTION Description. 1-2.Feature...

OSCILLOSCOPES. Oscilloscopes CS-5300 SERIES RS-232C OPTION OPTION CS-5370P/5370/5350 FEATURES OUTLINE. Photo: CS-5370P

SAFETY TERMS AND SYMBOLS

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

DIGITAL STORAGE OSCILLOSCOPES

EC Declaration of Conformity

30MHz Dual Trace Oscilloscope

Performance Characteristics

Specifications for DS1000CA Series

NEW. ANALOG OSCILLOSCOPE Model KM MHz KM MHz TRIGGERING SYSTEM: ELECTRICAL SPECIFICATIONS : X-Y OPERATION: OTHERS :

BK PRECISION INSTRUCTION MANUAL. MODELS 2120B and 2125A. 30 MHz DUAL-TRACE OSCILLOSCOPES + PRECISION

Specifications. Specifications and Characteristics Specifications

Instruction Manual for AT7328/7340 Dual Channel Oscilloscope

KENWOOD OSCILLOSCOPES TEST & MEASURING INSTRUMENT

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Analog Oscilloscope Operation Manual

20MHz Dual Trace Oscilloscope MODEL: MC1

30 MHz Oscilloscope Scientech 801C

GOS-6xxG Family Dual Trace Oscilloscope

U1571A Ni-MH Battery Pack for U1600A Handheld Oscilloscopes

Divide. MHz models) waveform record

SS-7847A (470MHz) TS (1GHz)

U1604A Handheld Oscilloscopes, 40 MHz

Sirindhorn International Institute of Technology Thammasat University at Rangsit

Electric Circuit II Lab Manual Session #1

Operating Manual Ver 1.1

DSO 3000 Series Oscilloscope

TEST INSTRUMENT SAFETY WARNING

The specifications apply when the function generator is powered on for at least 30 minutes under 18 C~28 C.

Chapter 5 : Specifications

Department of Electrical and Computer Engineering. Laboratory Experiment 1. Function Generator and Oscilloscope

Oscilloscope. Analog Oscilloscope Operation Manual. 99 Washington Street Melrose, MA Phone Toll Free

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

Oscilloscope and Function Generators

Characteristics. Frequency (DG1022) Sine, Square, Ramp, Triangle, Pulse, Noise, Arb. ±50 ppm in 90 days ±100 ppm in 1year 18 C ~ 28 C.

Digital Storage Oscilloscopes Models 2540B, 2542B, 2540B-GEN, 2542B-GEN

Appendix A: Specifications

2-channel models. 4-channel models

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

DS 6000 Specifications

U1600 Series Handheld Digital Oscilloscopes

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Easy to Use Design.

N acquisitions, all channels simultaneously, N is selectable from 4, 16, 64, and 128 Inputs

EE 201 Function / Arbitrary Waveform Generator and Oscilloscope Tutorial

Data Sheet. Digital Storage Oscilloscope. Features & Benefits. Applications. Ease-of-Use Feature DSO5202BMT DSO5102BMT DSO5062BMT

Data Sheet. Function/Arbitrary Waveform Generator. SDG1000 Series DataSheet. Application fields: Edit arbitrary waveform

Specifications DG1022 & DG1022A

Digital Storage Oscilloscope

DS1000B Series Digital Oscilloscopes

DS1102E, DS1052E, DS1102D, DS1052D

MODEL POLYTECHNIC COLLEGE KARUNAGAPPALLY Ph: TENDER NOTICE

Dual Channel Function/Arbitrary Waveform Generators 4050B Series

Handheld Digital Storage Oscilloscopes 2510 Series

DG5000 Series Specifications

DS4000 Series Digital Oscilloscope

Dual Channel Function/Arbitrary Waveform Generators 4050 Series

Chapter 13 Specifications

XK-700 DELUXE DIGITAL / ANALOG TRAINER

Fluke 192/196/199. ScopeMeter. Users Manual

DDS Function Generator Selection Guide

CRO AIM:- To study the use of Cathode Ray Oscilloscope (CRO).

DEPARTMENT OF THE ARMY TECHNICAL BULLETIN

Output Impedance. Duty Cycle Range. Buffer Size Resolution. PROTECTION Input Over Voltage. Output Short Circuit. TRIGGERING Sources.

Why Modern Servicing Requires Complete Waveform & Circuit Analyzing!

SHO800 Series Handheld Digital Oscilloscope

Agilent Technologies 3000 Series Oscilloscopes

Hantek2000 Series 3u1 Oscilloscope+DMM+AF generator

DIGITAL OSCILLOSCOPES & DIGITAL SCOPES

Combinational logic: Breadboard adders

Product Channels Bandwidth Sampling Rate Memory Resolution

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

Function/Arbitrary Waveform Generator

Analog Arts SL987 SL957 SL937 SL917 Product Specifications [1]

U1600 Series Handheld Digital Oscilloscopes

MINUTES OF PRE BID MEETING

EECE208 INTRO To ELECTRICAL ENG LAB. LAB 2. Instrumentation

Data Sheet. DG1000 series Dual-Channel Function/Arbitrary Waveform Generators. Product Overview. Main Features. Applications. Easy to Use Design

RIGOL Data Sheet. DG1000 Series Dual-Channel Function/Arbitrary Waveform Generator. Product Overview. Main Features. Applications. Easy to Use Design

Data Sheet. Function/Arbitrary Waveform Generator SDG1000 Series. SDG1000 Series DataSheet. Application fields: Edit arbitrary waveform

EENG-201 Experiment # 4: Function Generator, Oscilloscope

DG4000 Series Waveform Generators

Analog Arts SF990 SF880 SF830 Product Specifications

5MHz FUNCTION GENERATOR

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Laboratory equipments. Parameters of digital signals.

5MHz FUNCTION GENERATOR

Wider vertical range (500 uv/div~10 V/div), lower noise floor, better for small signal capturing. Built-in dual-channel 25 MHz source (MSO/DS2000A-S)

Agilent Technologies 3000 Series Oscilloscopes

PC Based Digital Oscilloscope

Analog Arts SG985 SG884 SG834 SG814 Product Specifications [1]

Oscilloscope Measurements

Agilent U2701A and U2702A USB Modular Oscilloscope. Data Sheet

DataSheet. SHS800 Series Handheld Digital Oscilloscope SHS820/SHS815/SHS810/SHS806. Application Domain

Exp. #2-6 : Measurement of the Characteristics of,, and Circuits by Using an Oscilloscope

Data Sheet. Function/Arbitrary Waveform Generator SDG1000 Series. SDG1000 Series DataSheet. Application fields: Edit arbitrary waveform

Data Sheet. Function/Arbitrary Waveform Generator. SDG1000 Series DataSheet. Application fields: Edit arbitrary waveform

LeCroy 9304A, 9304AM Digital Oscilloscopes 200 MHz Bandwidth, 100 MS/s. Main Features

Transcription:

Selection Guide Model TOS-2020CH TOS-2020CF TOS-2020CT TOS-2020 TOS-2020FG TOS-2100C TOS-2040CH TOS-2040CF TOS-2040CT TOS-2040 TOS-2040FG TOS-2050CH TOS-205CF TOS-2050CT TOS-2050 TOS-2050FG Max. bandwidth 20/40/50MHz 20/40/50MHz 20/40/50MHz 20/40/50MHz 20/40/50MHz 100MHz Attenuator switch Vertical encoder switch Vertical pulse switch Vertical sensitivity step 10 10 10 10 10 11 High vertical sensitivity 5mV/DIV 5mV/DIV 5mV/DIV 5mV/DIV 5mV/DIV 2mV/DIV Low vertical sensitivity 5V/DIV 5V/DIV 5V/DIV 5V/DIV 5V/DIV 5V/DIV Sweep encoder switch Sweep pulse switch Sweep time base step 20 20 20 20 20 22 Fastest sweep time 0.2us 0.2us 0.2us 0.2us 0.2us 50ns Slowest sweep time 0.5s 0.5s 0.5s 0.5s 0.5s 0.5s Dual sweep (Dual time base) Time base step auto-shift Trigger signal output CH1 signal output Z-axis input Trigger level lock Frequency counter Cursor readout Panel settings save & recall CRT illumination Delayed sweep Component test

Economic models TOS-2020CH/2040CH/2050CH TOS-2020CF/2040CF/2050CF: with built-in 6 digits frequency counter TOS-2020CT/2040CT/2050CT: with component test function Features Dual channel 20MHz/40MHz/50MHz 10 times sweep magnification TV synchronization; X-Y mode High illumination internal graticule CRT Japanese encoded switch, reliable and durable Fully sealed durable attenuation switch ALT triggering function, enabling simultaneous observation of two independent signals TOS-2020CH TOS-2020CF TOS-2020CT With built-in 6 digits frequency counter With component test function Specifications Model 20MHz 40MHz 50MHz Vertical system 5mV~5V/DIV, 10 steps in 1-2-5 sequence Accuracy 3% Vernier sensitivity Bandwidth DC (AC 10Hz)~20MHz DC (AC 10Hz)~40MHz DC (AC 10Hz)~50MHz AC coupling <10Hz (at 100kHz, 8DIV, frequency response -3dB) Rise time Approx. 17.5ns Approx. 8.75ns Approx. 7ns DC balance shift 5mV~5V/DIV: ±0.5DIV Vertical mode CH1, CH2, DUAL (ALT/CHOP), ADD, CH2 INV Chopping repetition frequency Approx. 250kHz Input coupling AC, GND, DC Max. Input voltage 400V peak-peak, AC frequency 1kHz Common mode rejection ratio >50:1 at 50kHz sine wave (set CH1 and CH2 at same sensitivity) CH2 INV BAL Balanced point variation 1DIV (referred to graticule center)

Horizontal system Sweep time Accuracy Vernier sweep time control Sweep magnification Position shift@x10mag Linearity Trigger mode Trigger level lock Trigger source Trigger coupling 0.2us~0.5s/DIV, 20 steps in 1-2-5 sequence ±3%, X10MAG: ±5% (20ns~50ns/DIV uncalibrated) X10 (fastest sweep time 20ns/DIV) 2DIV at CRT screen center ±5%, X10MAG: ±10% (0.2s~1us) AUTO, NORM, TV-V, TV-H Not provided Trigger slope + or - CH1, CH2, ALT, LINE, EXT AC: 20Hz to full bandwidth Frequency 20Hz~2MHz 2MHz~20MHz 20MHz~40MHz 40MHz~50MHz External trigger input X-Y mode X-axis bandwidth Phase error Calibration signal output Waveform Frequency CH1, CH2 1DIV 1.5DIV 2.5DIV 3DIV ALT 2DIV 3DIV EXT 200mV 800mV TV Sync pulse>1div (EXT: 1V) 400V (DC+AC peak), AC frequency 1kHz 5mV~5V/DIV±3% DC~500kHz (-3dB) 3 at DC~50kHz Positive-going square wave Approx. 1kHz Duty ratio <48:52 Output voltage 2Vpp±2% Approx. 1kΩ Frequency counter (only for TOS-2020CF, TOS-2040CF, TOS-2050CF) Display 6 digits LED Accuracy ±0.01% Component test (only for TOS-2020CT, TOS-2040CT, TOS-2050CT) Testing subject Testing voltage Testing frequency Testing current CRT Type Phosphor Accelerating voltage Trace rotation General Power source Accessories Dimension (WxHxD) Weight Resistor, Capacitor, Coil, Diode, Zener or simple combination of the components Approx. 9Vac pp 50/60Hz Approx. 0.6mA 6-inch rectangular with internal graticule, 8x10DIV (1DIV=1cm) P31 Approx. 2kV (20MHz); Approx. 12kV (40MHz) Adjustable at front panel AC110V/220V±10%, 50/60Hz, Max. 35VA Power cord x1, Operation manual x1, Probe x2 310x150x455mm Approx. 8kg

Standard models TOS-2020/2040/2050 TOS-2020FG/2040FG/2050FG: with built-in 6 digits frequency counter Features Dual channel 20MHz/40MHz/50MHz High sensitivity 1mV/DIV 10 times sweep magnification TV synchronization; X-Y mode Z-axis modulation input; CH1 signal output High illumination internal graticule CRT Japanese encoded switch, reliable and durable Fully sealed durable attenuation switch ALT triggering function, enabling simultaneous observation of two independent signals Trigger level lock and auto synchronize function TOS-2020 TOS-2020FG Standard model With built-in 6 digits frequency counter Specifications Model 20MHz 40MHz 50MHz Vertical system 5mV~5V/DIV, 10 steps in 1-2-5 sequence Accuracy 3%; X5MAG: 5% Vernier sensitivity Bandwidth DC~20MHz (X5MAG: DC~7MHz) DC~40MHz (X5MAG: DC~15MHz) DC~50MHz (X5MAG: DC~15MHz) AC coupling <10Hz (at 100kHz, 8DIV, frequency response -3dB) Rise time Approx. 17.5ns (X5MAG: Approx. 50ns) Approx. 8.75ns (X5MAG: Approx. 25ns) Approx. 7ns (X5MAG: Approx. 23.3ns) DC balance shift 5mV~5V/DIV: ±0.5DIV Vertical mode CH1, CH2, DUAL (ALT/CHOP), ADD, CH2 INV Chopping repetition frequency Approx. 250kHz Input coupling AC, GND, DC Max. Input voltage 400V peak-peak, AC frequency 1kHz Common mode rejection ratio >50:1 at 50kHz sine wave (set CH1 and CH2 at same sensitivity) CH2 INV BAL Balanced point variation 1DIV (referred to graticule center)

Horizontal system Sweep time Accuracy Vernier sweep time control Sweep magnification Position shift@x10mag Linearity Trigger mode Trigger level lock Trigger source Trigger coupling 0.2us~0.5s/DIV, 20 steps in 1-2-5 sequence ±3%, X10MAG: ±5% (20ns~50ns/DIV uncalibrated) X10 (fastest sweep time 20ns/DIV) 2DIV at CRT screen center ±5%, X10MAG: ±10% (0.2s~1us) AUTO, NORM, TV-V, TV-H Provided Trigger slope + or - CH1, CH2, ALT, LINE, EXT AC: 20Hz to full bandwidth Frequency 20Hz~2MHz 2MHz~20MHz 20MHz~40MHz 40MHz~50MHz External trigger input X-Y mode X-axis bandwidth Phase error CH1 signal output Calibration signal output Waveform Frequency CH1, CH2 1DIV 1.5DIV 2.5DIV 3DIV ALT 2DIV 3DIV EXT 200mV 800mV TV Sync pulse>1div (EXT: 1V) 400V (DC+AC peak), AC frequency 1kHz 5mV~5V/DIV±3% DC~500kHz (-3dB) 3 at DC~50kHz At least 20 mv/div at 50Ω terminal, frequency at least 50Hz to 50MHz Positive-going square wave Approx. 1kHz Duty ratio <48:52 Output voltage Z-axis input Bandwidth 2Vpp±2% Approx. 1kΩ DC~2MHz 5Vpp Approx. 47kΩ 30V (DC+AC peak), AC frequency 1kHz Frequency counter (only for TOS-2020FG, TOS-2040FG, TOS-2050FG) Display 6 digits LED Accuracy ±0.01% CRT Type Phosphor Accelerating voltage Trace rotation General Power source Accessories Dimension (WxHxD) Weight 6-inch rectangular with internal graticule, 8x10DIV (1DIV=1cm) P31 Approx. 2kV (20MHz); Approx. 12kV (40MHz) Adjustable at front panel AC110V/220V±10%, 50/60Hz, Max. 35VA Power cord x1, Operation manual x1, Probe x2 310x150x455mm Approx. 8kg

100MHz standard model with 10 sets panel settings storage TOS-2100C Features Dual channel 100MHz Time base auto-range Cursor readout with 7 measurements Panel lock function Buzzer alarm LED indicators TV synchronization; X-Y mode Z-axis modulation input; Trigger signal output Signal delay function, monitoring the leading edge Continuously adjustable screen illumination Delayed sweep 10 sets save & recall for panel settings Specifications Vertical system Accuracy 3% Vernier sensitivity Bandwidth (-3dB) AC coupling Rise time DC balance shift Vertical mode Chopping repetition frequency Input coupling Max. Input voltage Bandwidth limit Common mode rejection ratio Dynamic range CH2 INV BAL Signal delay Horizontal system Horizontal mode A (main) sweep time B (delay) sweep time 2mV~5V/DIV, 11 steps in 1-2-5 sequence Continuously variable to 1/2.5 or less of panel indicated value DC (AC 10Hz)~100MHz (2mV/DIV: DC~20MHz) <10Hz (at 100kHz, 8DIV, frequency response -3dB) Approx. 3.5ns (2mV/DIV: Approx. 17.5ns) 5mV~5V/DIV: ±0.5DIV CH1, CH2, DUAL (ALT/CHOP), ADD, CH2 INV Approx. 250kHz AC, GND, DC 400V peak-peak, AC frequency 1kHz 20MHz >50:1 at 50kHz sine wave (set CH1 and CH2 at same sensitivity) 5DIV at 100MHz Balanced point variation 1DIV (referred to graticule center) Leading edge can be monitored MAIN (A), ALT, DELAY (B) 50ns~0.5s/DIV, continuously variable (UNCAL) 50ns~50ms/DIV Accuracy ±3%, X10MAG: ±5% Sweep magnification Hold off time Delay time X10 (fastest sweep time 5ns/DIV) Variable 1us~5s Delay jitter Better than 1:20000 Alternate separation Trigger mode Trigger source Trigger coupling Variable Trigger slope + or - AUTO, NORM, TV-V, TV-H CH1, CH2, LINE, EXT AC, DC, HFR, LFR

Mode Auto Norm TV Frequency 10Hz~20MHz 20MHz~100MHz DC~20MHz 20MHz~100MHz Sync signal INT 0.35DIV 1.5DIV 0.35DIV 1.5DIV 1DIV EXT 50mVpp 150mVpp 50mVpp 150mVpp 200mVpp TV sync TV-V, TV-H Trigger level range INT: 4DIV or more, EXT: ±0.4V or more External trigger input 400V (DC+AC peak), AC frequency 1kHz X-Y operation Mode X-axis: selectable CH1, CH2, EXT ; Y-axis: selectable CH1, CH2, CH1 and CH 2mV~5V/DIV±3%; EXT: 0.1V/DIV ±5% X-axis bandwidth DC~500kHz (-3dB) Phase error 3 at DC~50kHz Trigger signal output Voltage Approx. 25mV/DIV into 50Ω terminal Frequency response DC~10MH Approx. 50Ω Calibration signal output Waveform Positive-going square wave Frequency Approx. 1kHz Duty ratio <48:52 Output voltage 2Vpp±2% Approx. 2kΩ Z-axis input Coupling DC Bandwidth DC~5MHz 5V or more 30V (DC+AC peak), AC frequency 1kHz Cursor readout Cursor measurement ΔV, ΔV%, ΔVdB, ΔT, 1/ΔT, ΔT%, Δθ Cursor resolution 1/25DIV Effective cursor range Vertical: ±3DIV; Horizontal: ±4DIV Panel setting Vertical: V/DIV (CH1, CH2), UNCAL, ALT/CHOP/ADD, INV, Probe factor, AC/DC/GND Horizontal: S/DIV (MTB, DTB), UNCAL, X10 MAG, delay time, HO Trigger: source, coupling, slope, level, TV-V, TV-H Others: X-Y, LOCK, Save/recall memory 0-9 Special function Time base auto-range, Panel lock, 10 sets save & recall for panel settings CRT Display 6-inch rectangular with internal graticule; 0%, 10%, 90% and 100% markers; 8x10DIV (1DIV=1cm) Phosphor P31 Accelerating voltage Approx. 16kV CRT illumination Continuously adjustable General Power source AC110V/220V±10%, 50/60Hz, Max. 65VA Accessories Power cord x1, Operation manual x1, Probe x2 Dimension (WxHxD) 310x150x455mm Weight Approx. 8kg Specifications are subject to change without prior notice.