Analysis of static and time-variable magnetic fields

Similar documents
Safety Evaluation Within a Magnetic Field Environment

Safety Evaluation Within a Magnetic Field Environment

Narda EMF drive test solution

Selective and broadband low frequency field analysis

For Isotropic Measurement of Magnetic and Electric Fields

Selective and broadband low frequency field analysis

Selective and broadband low frequency field analysis

Continuous, remote monitoring and logging of electromagnetic fields

Evaluation of exposure to pulsed magnetic fields by examining the variations in the spectrum and over time with ELT-400

Monitoring electric and magnetic fields

Selective and broadband high frequency field analysis

Monitoring electric and magnetic fields

Selective and broadband low frequency field analysis

Exposure Level Tester ELT-400

Safety in electromagnetic fields. EMF Directive 2013/35/EU

Monitoring electric and magnetic fields

Frequency selective monitoring and logging of environmental electromagnetic fields

Advanced Test Equipment Rentals ATEC (2832)

Low Frequency. Precision test equipment for safety in electric and magnetic fields

Narda DF Antennas - Datasheet. Datasheet

Continuous, remote monitoring and logging of electromagnetic fields

Parameters in Scope mode

Jammers. Interference and Direction Analyzer IDA 2. Application Note

Continuous, remote monitoring and logging of electromagnetic fields

Features of Spectrum Analysis mode

SRM When Safety Counts SRM SRM-3006 Selective Radiation Meter for electromagnetic fields up to 6 GHz

SignalShark - Preliminary Datasheet* Real-Time Handheld Analyzer

Selective measurement of high frequency electric and magnetic fields

Accredited calibration of field strength meters

Selective measurement of high frequency electric and magnetic fields

SRM: WHEN SAFETY COUNTS. SRM-3006: SELECTIVE RADIATION METER FOR ELECTROMAGNETIC FIELDS UP TO 6 GHz

NHT 3DL. The new landmark meter for electromagnetic safety. Percipere Aestimare et Inquirere

SRM-3006 Reliably measuring actual HF immissions

Selective measurement of high frequency electromagnetic

Selective measurement of high frequency electromagnetic

Making sure of a healthy environment. Narda EMF Monitors. Improving safety in electromagnetic fields

SignalShark. NSTS 1017-E0328B / SignalShark Datasheet Subject to change without notice

SignalShark Real-Time Remote Analyzer

Safety Test Solutions. SRM-3006 Selective Radiation Meter. Selective Radiation Meter

Capturing IQ data with NRA and IDA

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

Interference and Direction Analyzer

Nardalert S3 and RadMan / RadMan XT Personal Monitors. Personal Monitors Nardalert S3 and RadMan / RadMan XT

User s Manual PMM 8053B

MAGNETIC FIELD METER Operator s Manual

OPERATIONS MANUAL. narda MODEL 8513 INDUSTRIAL COMPLIANCE METER. for Electromagnetic Energy. Safety Test Solutions. P/N Rev B

SRM-3000 Selective Radiation Meter

MAGNETIC FIELD METER Operator s Manual

Dive deep into interference analysis. Interference Direction Analyzer

FREQUENCY-SELECTIVE, ISOTROPIC MEASUREMENT, EVALUATION, AND RECORDING OF HIGH FREQUENCY ELECTROMAGNETIC FIELDS

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2009

Handheld Gaussmeter Gaussmeter

thin and flexible probes factory calibration certificate with traceability High precision Analog output: DC 35 khz (depending on probe type)

Safety in high frequency electromagnetic fields

Dive deep into interference analysis. Interference Direction Analyzer

3D-magnetic field probes AS-U3D GEO-X for ±200 µt

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

Personal & Area Monitors

Advanced Test Equipment Rentals ATEC (2832)

GSP303D 3-Axis Digital Magnetic Field Transmitter

User s Manual EHP-50F

Field Probes Frequency range Level range

Measuring and monitoring with precision. NRA-RX Narda Remote Analyzer

ExpoM - ELF User Manual

OPERATIONS MANUAL. narda MODEL 8511 INDUSTRIAL COMPLIANCE METER. for Electromagnetic Energy. Safety Test Solutions. P/N Rev B

DF Antennas - Datasheet. Datasheet

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

CLIO Pocket is Audiomatica's new Electro-Acoustical Multi-Platform Personal measurement system.

F3A Magnetic Field Transducers

World-Class Accuracy & Measurement Range (40 Conventional Models)

Electromagnetic Field Measurement System

Digital Gauss/Tesla Meter

I1A Magnetic Field Transducers

Immission measurements in the vicinity of LTE base stations

Operation of Short Wave broadcast transmitting stations

2801 Multilock. Communications System Analyzer. Data Sheet. Boosting wireless efficiency

Magnetic Field Compensation System MR-3

MAGNETOSCOP Measurement of magnetic field strengths in the range 0.1 nanotesla to 1 millitesla

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

BENNING. CM7 Electrical Tester. Service Information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

User s Manual EHP-200 EHP-200A

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Advanced Test Equipment Rentals ATEC (2832) OPERATIONS MANUAL. narda Safety Test Solutions MODEL 8712

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

Manual Hand-held Gaussmeter BGM101

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

F1A Magnetic Field Transducers

Where Safety Matters, Use The Latest Technology

IOSH Webinar. Control of Electromagnetic Fields at work regulations 2016 Part 2 EMF exposure assessment 4 th May 2017 Julia Clark FSRP CMIOSH

MAGNETIC FIELD MEASURING

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

KMT - Kraus Messtechnik GmbH

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

ASONIK POLAND, PL Tuczno, str. Sloneczna 6. Tel./Fax. (061)

Analysis of magnetic and electromagnetic field emissions produced by a MRI device

Everything you always wanted to know... Safety in electric, magnetic and electromagnetic fields Basic facts

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Transcription:

Magnetometer HP-01 Analysis of static and time-variable magnetic fields Field exposure evaluation according to current standards and regulations such as Directive 2013/35/EU for workplaces Frequency-selective and wideband measurement of magnetic fields from 0 Hz to 1000 Hz Non-directional (isotropic) measurement with orthogonally arranged Hall sensors Extremely wide measurement range from 10 µt to 10 T (dynamic range 120 db) FFT spectrum analysis and time response display Narrow band filter for standard compliant measurement in the range 0 Hz to 1 Hz Optical interface for control by PC or NBM-550 (not yet supported) Magnetometer HP-01 NSTS 0517-E0332A 1 / 6 Subject to change without notice

APPLICATIONS The Magnetometer HP-01 is a device for measuring static magnetic fields and time-variable fields of frequencies up to 1000 Hz. Its main application is in the measurement of high static fields with the aim of ensuring the safety of personnel who have access to areas where such fields are present. The possible risks are due to indirect effects, such as the force exerted on ferromagnetic objects. As a consequence, hazards can result from flying objects (projectile effect), or from the force exerted on passive implants, or from functional impairments in active implants. These must be identified and avoided. Risks can also occur due to direct effects when the magnetic flux density is very high and movement of the body within the field results in stimulation of sensory cells or nerve cells. Exposure limit values are laid down in the ICNIRP Guidelines and in the European Directive 2013/35/EU among other regulations. The action levels depend on the source of the hazard, ranging from relatively low values (e.g. 0.5 mt for effects on active implants) up to very large values of several Tesla. Typical areas where high fields are present are: Magnetic resonance tomography (MRT) Magnetic resonance spectroscopy (MRS) Use and production of strong permanent magnets such as lifting magnets DC generators, particularly superconducting DC motors, e.g. in railroads Applications involving electric vehicles Large industrial magnetic stirrers Electrolysis used in the production of chlorine and aluminum Figure 1: Particularly high static magnetic fields are generated by magnetic resonance tomography (MRT) Figure 2: Static magnetic fields are also present in DC powered railroads NSTS 0517-E0332A 2 / 6 Subject to change without notice

FUNCTION The exposure level limits and action levels specified in guidelines and standards cover a wide range of values. This would usually mean that several different measurement probes would be needed in order to achieve the necessary measurement dynamic range. The HP-01 easily covers all these applications with its built in Hall effect sensors, which have an unusually wide overall dynamic range from 10 µt to more than 10 T. Additional measurement probes are not needed. The orthogonal arrangement of the sensors in the tip of the probe wand ensures that the three spatial axes are captured completely, guaranteeing an isotropic (non-directional) measurement. The sensors are located approximately 7 mm below the tip of the wand and are indicated by a clearly visible groove. The HP-01 is much more than just a magnetometer probe, however. It includes a very powerful FFT analyzer that allows signal analysis in both the time and the frequency domains. The fast signal processing allows detailed, highly accurate gap-free analysis of the frequency spectrum. The results can be displayed as a live spectrum, as a spectrogram versus time, or as a three-dimensional waterfall diagram. Figure 3: Connector side of HP-01 with tripod adapter attached The DC 1 Hz operating mode is a further special feature that is particularly suitable for standard-compliant measurements according to human safety standards. The limit values are usually specified for static fields and variable fields with frequencies of up to 1 Hz. A finite impulse response (FIR) filter used in the HP-01 captures just these frequency components. The measurement is made using a high sampling rate and delivers the corresponding wideband value for the 0 Hz to 1 Hz range, which is required in order to demonstrate compliance with the limit values. If required, more extensive analysis in the sub-hertz region can be performed from the time domain display of the instantaneous values. This would not be possible in this way from the FFT analysis. Figure 4: Main window with display of measurement parameters and numerical result The HP-01 is operated using the HP01-TS software supplied, which is compatible with all Microsoft Windows based PCs running Windows 7 or above. An optical cable with USB adapter links the measuring device to the PC. The measurement can therefore be controlled from a safe distance of up to 10 m. This can be extended to 50 m with cables, available as options. Figure 5: Time response display of a sine wave signal in the sub-hertz range in DC-1Hz operating mode NSTS 0517-E0332A 3 / 6 Subject to change without notice

MEASUREMENTS USING A PC The graphical user interface of the HP01-TS PC Software is arranged very clearly and is easy to use. The main window (Figure 4) is displayed when the program starts. The main settings such as measurement range and frequency range are made in this window. The display area continuously shows the numerical value of the magnetic flux density measurement result, separately for the three spatial axes if required. Click on the Zero button to trigger a zero adjustment that reduces measurement uncertainty to a minimum. For this, the probe tip is placed in the zero field chamber supplied, to exclude effects due to the earth s magnetic field or other fields. Three different modes enable selection of frequency ranges for static fields (DC to 1 Hz), or for any single frequency, or for band integration with settable frequency limits. In addition to the numerical display of the measurement value, the time response of the magnetic flux density can also be shown and evaluated graphically. The graph shows the time response of the RMS value for each of the three spatial axes and the isotropic total value. A constant sine wave signal appears as a continuous horizontal line. In DC - 1 Hz mode, the instantaneous value is shown instead of the RMS value, i.e. a sine wave signal is also shown as a sine wave (Figure 5). This means that even the frequency and amplitude of signal components below 1 Hz can be determined. Figure 6: FFT analysis with display of amplitude spectrum FFT analysis represents the spectral distribution of the signal as an amplitude spectrum (Figure 6). The spectrums are shown for the three separate axes as well as for the isotropic total value. The frequency range can be adapted in four stages by appropriate selection of the Span. Two markers are provided to simplify result evaluation. It is also possible to show the variation in the spectrum over time graphically, either as a spectrogram (Figure 7) or as a waterfall diagram (Figure 8). Figure 7: FFT analysis with spectrogram display Figure 8: FFT analysis with spectrum displayed as a waterfall diagram NSTS 0517-E0332A 4 / 6 Subject to change without notice

SPECIFICATIONS a HP-01 Magnetometer Frequency range Probe type Field sensor Measurement range b Overload Dynamic range (after zeroing) DC (0 Hz) to 1000 Hz Magnetic (B) field Triaxial orthogonal Hall effect devices (temperature compensated) Simultaneous triaxial acquisition Sensor area approx. 0.6 mm x 0.6 mm (10 T), approx. 0.15 mm x 0.15 mm (60 mt) Auto Range ±10 µt to ±10 T (units: mt, T, G, kg) 60 mt ±10 µt to ±60 mt (units: mt, G) 10 T ±0,010 T to ±10 T (units: T, kg) 20 T 120 db (Auto Range) 60 mt range 100 nt (Span 20 Hz and 30 Hz), 1 µt (Span 100 Hz and 1000 Hz) Resolution 10 T range 100 µt (Span 20 Hz and 30 Hz), 1 mt (Span 100 Hz and 1000 Hz) Displayed average noise level (DANL) c 10 µt Flatness of frequency response 0.5 db (typ.) Expanded measurement uncertainty d ±1 % Temperature response 0.05 %/ C typ. (@ 0 Hz referred to 23 C) Temperature and humidity meter Internal sensor, temperature: -20 C to + 55 C, humidity: 5 % to 95 % RH DC MODE Frequency range 0 Hz to 1 Hz Filter FIR filter, cut-off frequency 1.0 Hz (-3 db) Result display Numerical result display and time plot (instantaneous value vs. time) Reading update time 67 ms Result type Instantaneous value, maximum hold, averaging (linear) FFT MODE Spectrum analysis Real-time gapless e FFT SPAN (selectable) 20 Hz 30 Hz 100 Hz 1000 Hz Frequency range 0 20 Hz 0 30 Hz 0 100 Hz 0 1000 Hz Resolution 0.2 Hz 0.3 Hz 1 Hz 3 Hz RBW (-3 db) 0.8 Hz 1.2 Hz 4 Hz 10 Hz Spectrum (full Span), spectrogram, waterfall (3D) Result display Numerical broadband value with selectable cut-off frequencies, time plot (RMS vs. time) Single frequency and time plot (RMS) Reading update time < 350 ms Result type Actual value (RMS), maximum hold, averaging (RMS) OPERATION Measurement control and display Via PC (not included) and supplied software HP01-TS or via NBM-550 (this function is not yet available) Supported operating systems Microsoft Windows 7, 8/8.1, 10 Data interface Serial optical interface (115200 Baud) with optical converter to USB a Unless otherwise stated, these specifications apply for the reference condition: ambient temperature 23 C, relative air humidity 50 % b For each single axis. Positive and negative at static fields (DC) c After zeroing. DANL is frequency and SPAN depending. The specified performance is referred to 0 Hz and SPAN 20 Hz d At static fields (DC) e Overlapping for Span 20 Hz, 30 Hz and 100 Hz NSTS 0517-E0332A 5 / 6 Subject to change without notice

GENERAL SPECIFICATIONS Fastening thread 1/4-20UNC-2B (tripod thread on underside of device) Power supply Battery Li-Ion, rechargeable (3.7 V / 250 mah) Operating time 6 hours AC/DC charger 100 to 240 V AC / 47 to 63 Hz, 12 V / 1.5 A, fits all AC line connectors Charging time 2.5 hours (typ.) Temperature range Operating -20 C to +55 C Charging 0 C to +40 C Storage -30 C to +75 C Humidity range Operating 5 to 95 % relative humidity, non-condensing Size Basic unit Sensor stick: Ø 9 mm, L 143 mm; Main body: Ø 43 mm, L 57 mm; Overall length: 200 mm Carrying case 120 mm x 365 mm x 305 mm Weight Basic Unit: 100 g; Complete set with carrying case: 1.65 kg Recommended calibration interval 24 months Country of origin Italy ORDERING INFORMATION HP-01 Magnetometer HP-01 Magnetometer Set DC-1kHz Includes: - HP-01 Basic Unit - Zero Gauss Chamber - AC/DC Battery Charger - Cable, FO Duplex (1000 µm) RP-02, 10 m - Cable, FO Duplex (1000 µm) RP-02, 25 cm - O/E Converter USB, RP-02/USB - Conical Tripod Support - HP-01 / NBM Adapter - Software CDROM including User s Manual - Certificate of Calibration - Carrying Case Part number P/N 2405/101 OPTIONAL ACCESSORIES Tripod, Non-Conductive, 1.65 m with Carrying Bag 2244/90.31 Tripod Extension, 0.50 m, Non-Conductive 2244/90.45 Cable, FO Duplex (1000 µm) RP-02, 2 m 2260/91.02 Cable, FO Duplex (1000 µm) RP-02, 5 m 2260/91.09 Cable, FO Duplex (1000 µm) RP-02, 20 m 2260/91.03 Cable, FO Duplex (1000 µm) RP-02, 50 m 2260/91.04 Narda Safety Test Solutions GmbH Sandwiesenstrasse 7 72793 Pfullingen, Germany Phone: +49 7121 9732 0 Fax: +49 7121 9732 790 E-Mail: support.narda-de@l3t.com www.narda-sts.com Narda Safety Test Solutions 435 Moreland Road Hauppauge, NY 11788, USA Phone: +1 631 231-1700 Fax: +1 631 231-1711 E-Mail: nardasts@l3t.com www.narda-sts.us Narda Safety Test Solutions Srl Via Leonardo da Vinci, 21/23 20090 Segrate (Milano) - Italy Phone: +39 02 2699871 Fax: +39 02 26998700 E-mail: nardait.support@l3t.com www.narda-sts.it Names and Logo are registered trademarks of Narda Safety Test Solutions GmbH and L3 Communications Holdings, Inc. Trade names are trademarks of the owners. NSTS 0517-E0332A 6 / 6 Subject to change without notice