(

Similar documents
COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

CAST RESIN DRY TRANSFORMER

AM SGB Sdn Bhd. Company Profile. Transformer First Class

TMC Transformers TMC

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

Dry-type Transformer. High Reliability Maintenance-free Environmentally Friendly

Cast resin transformers HARMONY TM

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

Basic Principles and Operation of Transformer

Liquid-Filled Transformers

K Factor Power Transformers

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

Convincing technology creates compact performance

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

siemens.com/transformers Convincing technology creates compact performance The GEAFOL Basic: the optimum foundation for power distribution

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

nical catalogue Tech

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

ELETTROMECCANICA. Since english OIL IMMERSED DISTRIBUTION TRANSFORMERS

OIL-IMMERSED ARC-SUPPRESSION COILS

Climatic, Environmental and Fire Behaviour (C2 E2 F1) Test of Cast Resin Transformer

The GEAFOL Neo: the optimum foundation for power distribution siemens.com/transformers

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Efacec work every day to anticipate solutions for a sustainable world in the new energy era.

TECHNICAL INFORMATION

Ritz Instrument Transformers GmbH. Welcome

SGB at a glance. One of the leading manufacturers. for transformers worldwide

T S 15KVA 1PH 240/480 Transformer

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

Description. Features and Benefits

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

Onsite Mobile AC High Voltage Test System

Energy Efficient Distribution Transformers

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

SECTION 16322B SUBSTATION TRANSFORMERS DRY-TYPE

Introduction. Centrado leading-edge transformer. Introduction

DESIGNED MANUFACTURED TESTED

Technical Performance LS Cast Resin Transformers 50kVA Through 15,000kVA Primary Voltage: 2.3kV Through 36kV Secondary Voltage: 120V Through 24kV

012: 2015 CEB SPECIFICATION GALVANIZED STEEL WIRE (EXCEPT SHIELDING WIRE FOR TOWER LINE APPLICATION)

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

TRAFTOR WINDINGS CHANGING THE RULES TOROIDAL INDUCTORS & TRANSFORMERS SOLUTIONS PROVIDER AND MANUFACTURER

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

.1 Provide dry type cast-resin 11kV/0.420kV transformers in accordance with the Contract Documents.

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

AC Voltage Test System with Transformer

INVESTIGATION OF CAST RESIN TRANSFORMER MANUFACTURING IN AM SGB SDN BHD VALLIAMMAI A/P S.PALANIAPPAN

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R

Particulate Control O&M Training. APC/PCUG Conference July 12-16, 2009 The Woodlands, TX

3-Phase Transformers. Author: Sergey Dubatov. belfuse.com/signal

MEDIUM VOLTAGE COMPACT STARTER TYPE KAE

Trasfor 3E Series. Reliable Answers to Your Questions. Made in Switzerland

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

Cast Resin Transformers

ULTRA-K Series 600K - he

Strip Tinning China & Asia. Strip Tinning Ltd UK. Listen, Research, Innovate, Design...

VIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs

Product Data Sheet 3252J/2H3PU

Powering Your Business

Arc Suppression Coils

ABB Power Products Service

TRAFO ELECTRIC P. LTD.

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

Transformers Contents Page

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS CT & PT GROUP C

VARIABLE FREQUENCY RESONANT TEST SYSTEM

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

1.5 kva Single Phase Transformer - 120V Primary Voltage - 277V Secondary Voltage - NEMA 3R

MAC-AFRIC USER S MANUAL MODEL: D.C.INVERTER WELDER 160/200 AMP

HOW TO SAFE GUARD THE TRANSFORMER..???

WATERFLUX 3000 Quick Start

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS. Engineered for Egypt

Copper Core & Coil Transformer

Siemens Transformer Technology Seminar Insulation & Thermal Design

MODERN POWER TRANSFORMER PRACTICE BIBLIOGRAPHY

Mobile Power Transformer Test Systm

INSTRUMENT TRANSFORMERS. Right Choice for Metering and Protection of Power. Electricfield

About us. Vision. To lead our field in innovation, quality and customer service.

Product Data Sheet RG160-28/18N/2TDPU-331

Oil tempered SiCrV-alloyed high tensile valve spring wire Only manudactured in China

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

Your safety first! This is the reason why our manual begins with the following guidelines:

Underground System Design TADP 547

PES & IAS NY Chapter And NY LMAG June 23 rd, 2015

Arqrn{r$frqreffiffi. il il. ffirffiil,ilkffi*&ffiffixiil{tt. l{epal Hydro & Electric L,imited. cent. tso Regd No.: ISO 9001:2008

Technical Questionnaire 9.101/6 Transformer Test System. Personal Data. Application. Test of. Delivery scope

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

Transcription:

(www.xatianhong.com)

Introduction to XATH Xi'an Tianhong Electric Co., Ltd. (XATH) is a solely state-owned enterprise, set up by China Shipbuilding Industry Corporation (CSIC). It is one of the largest manufacturers of power transmission and distribution equipments in China. With advanced technology and vast experiences in manufacturing of dry type and oil-immersed transformers, XATH is one of the China s leading in the design, production and selling of cast resin dry type transformers (voltage: 6kV-35kV, capacity: 30kVA-20000kVA), oilimmersed transformers (voltage: 6kV-150kV, capacity: 30kVA-50000kVA), explosion-proof transformers, prefabricated substations, high and low voltage power distribution cabinets. Other types of transformers for special use, extinction coils, grounding transformers and reactors are also produced accordingly to clients special requirements. XATH Main Office XATH Plant XATH production and facilities are certified to ISO9001:2000, ISO14001:2004, GB/T24001-2004, GB/T19001-2000, GB/T28001-2001, GB7251, IEC6076-11, (Full Routine, Type & Special Tests with KEMA), GB1094, JB/T10088 and CCC etc. Today, XATH products are sold in more than 30 provinces and exported to all over the world. XATH product are served in many international engineering projects and received satisfied feedback from the users on the quality, reliability and cost effectiveness. Production Line Finished Goods 1

XATH Cast Resin Transformer Going Green Termination Bars Assembly Section Testing Section XATH cast resin transformers have the highest standard of quality and reliability by using precision equipments and advanced state-ofthe-art technology. XATH Cast resin transformers are safe, nonflammable, fire resistance, pollution-free (no coolants required) and moisture-proof. They are unnecessary to be maintained. Installation is simple even can be fixed close to load centers. XATH Cast resin transformers have low energy running cost, low partial discharge, low noise level, high short time overload capacity, powerful heat-sinking capacity and when equipped with forced air fan, the temporary power may be increased up to 150% of the rated capacity. What is more, XATH Cast Resin Transformers HV and LV winding are both vacuum casted which guarantee optimum performance. In short XATH Cast Resin Transformers are safe and environmental friendly. Going green in line with the needs for the global sustainable development 2

The Core XATH transformers cores are constructed using high quality cold-rolled silicon steel sheet with advance cutting, lamination and assembly process. The sheets are cut in high precision and stacked by fine grades stepped construction and form 45 full oblique joint. This high precision step lap method reduces no-load losses and the idling current, ensuring great reduction of transformer noise level. Steel Coils The core will be than heat treated and surface treated with resin to ensure high humidity resistance and corrosion protection. Sheet Cutting Line Completed Core Core Assembly 3

resin casting by xath Construction of Cast resin composite material, namely Glass fiber reinforcement of windings is the master piece of the XATH Cast resin transformer. The composite material is perfectly blended to has high tensile strength and a coefficient of expansion close to that of copper. The material has good corrosion resistance, fire retarded and good resistance to temperature shocks. The cycle of polymerization is precisely controlled in vacuum chamber to guarantee no air intrusion. All XATH transformers LV and HV windings are both vacuum casted, which means guarantee free of voids. Cooling ducts are created to give efficient heat dissipation which guarantee high service life of transformer. low voltage windings Winding Process XATH transformers low voltage windings are constructed using insulated copper foil, laminated with DMD insulation papers. The connection between the copper foil and the terminal bars are made through precision Argon shield arc welding. The completed winding is impregnated at vacuum system at high temperature and form a smooth solid body of fiber glass reinforced epoxy. High voltage windings XATH transformers high voltage windings are constructed using enameled copper wire in double layer winding. The windings are wound with fiberglass on both sides on precision winding machine. Vacuum Chamber The completed winding is impregnated at vacuum system at high temperature and form a smooth solid body of fiber glass reinforced epoxy. XATH high voltage coils therefore guarantees resistance against sudden workload and ambient temperature changes. Completed LV Coils Completed HV Coils Completed HV Coils 4

enclosure (optional) The transformers can be protected with enclosure, either indoor or outdoor according to protection grade. The commonly used IP20 enclosure provides protection against the entrance of foreign objects with diameter greater than 12mm and only fit for indoor. Enclosure is made of either epoxy painted mild steel or aluminium alloy plates. Forced air ventilation system (optional) When temporary power increases are expected then forced air ventilation system is recommended. The ventilation kit is provided with an electrical panel to control the fan using temperature device. With this optional fixture, the power may be increased up to 150% of the rated capacity. Internal View (Alloy plates) Forced Air Fan In Enclosure Forced Air Fan temperature indication and control system The temperature automatic control system provide guarantee for long term, safe and reliable running of transformer. External View (Alloy plates) Temperature Control The system provide temperature presetting, recording, warning, tripping signal, starting and stopping the ventilation fans automatically. 5

quality comes first at xath XATH invest heavily in quality assurance program. Tests and routine inspections are carried out systematically and at random at all stages of production to ensure XATH transformers meet all standards and specifications even before the final assembly. The manufacture of XATH Cast resin transformer is certified in accordance with ISO9001 and ISO14001. XATH cast resin transformers are designed and produced in accordance with IEC 60076-11 standard. Testing In Progress Tx Loaded To Testing Section Testing Console Testing Equipments Testing Equipments 6

Quality and safety management IEC 60076-11 Routine, Type & Special Test With KEMA Quality Management System Certificate ISO9001 Environmental Management System Certificate ISO14001 Occupational Health And Safety Management System Certificate 7

Structure of product (Optional) 8

Technical data/specifications Sc(b)9/10/11 Series 11kv class cast resin Dry Type Power transformers Dimensions Specifications Rated Voltage: 11kV Vector Group: Dyn11, YynO Low Voltage: 0.433kV Insulation Level: L175AC35/LIOAC5 Rated Power kva Type P 0 P k 75 P k 120 U k L PA Weight Length Width Height W W W % db(a) kg mm mm mm 800 1000 1250 1600 2000 2500 3000 SC(B) 9 1710 6420 7360 6 50 2520 1585 1000 1610 SC(B)10 1520 6070 6950 6 48 2600 1650 1100 1690 SC(B)11 1370 5770 6610 6 48 2850 1810 1000 1680 SC(B) 9 1980 7510 8600 6 50 2820 1630 1100 1700 SC(B)10 1760 7100 8130 6 48 3060 1710 1100 1780 SC(B)11 1600 6100 7730 6 48 3360 1880 1000 1800 SC(B) 9 2340 8960 10260 6 52 3460 1700 1100 1820 SC(B)10 2080 8460 9690 6 48 3640 1750 1100 1820 SC(B)11 1800 7500 9210 6 48 4010 1920 1100 1990 SC(B) 9 2750 10840 12400 6 53 4200 1850 1100 1810 SC(B)10 2440 10240 11730 6 48 4420 1840 1100 1810 SC(B)11 2200 8800 11140 6 48 4860 2050 1100 2050 SC(B) 9 3400 13360 15300 6 53 4770 2020 1360 1960 SC(B)10 3060 12620 14450 6 50 5200 2080 1360 1820 SC(B)11 2720 11800 13730 6 50 5340 2180 1360 2160 SC(B) 9 4000 15870 18180 6 54 5760 2080 1360 2080 SC(B)10 3600 14900 17170 6 50 5880 2170 1360 1970 SC(B)11 3200 13800 16310 6 50 6460 2300 1360 2270 SC(B) 9 4950 22950 26300 8 54 5600 2180 1900 2360 SC(B)10 4500 21000 24060 8 54 6480 2100 1400 2150 SC(B)11 4000 19900 22800 8 54 6850 2150 1400 2250 All given sound levels are max. values. P o: No-Load Loss P k 75 C: Load Loss at 75 C P k 120 C: Load Loss at 120 C U k: Impedance L PA: A-weight Sound Pressure Level in db NOTE: Technical data subject to change without prior notice. SC(B)9 Normal Loss SC(B) 10 Low Loss SC(B) 11 Super Low Loss 9

Technical data/specifications Sc(b)10 series 33kv class cast resin Dry Type Power transformers Dimensions Specifications Rated Voltage:33 kv Vector Group:Dyn11, YynO Low Voltage:0.433 kv Insulation Level:L170AC170/LIOAC5 Rated Power kva Type P 0 P k 75 P k 120 U k L PA Weight Length Width Height W W W % db(a) kg mm mm mm 800 SC(B)10 2390 8330 9550 6 48 3400 1870 1000 1690 1000 SC(B)10 2690 9550 10950 6 48 4110 1940 1000 1760 1250 SC(B)10 3140 11650 13350 6 49 5190 2070 1100 1930 1600 SC(B)10 3590 14180 16250 6 49 5790 2170 1100 2030 2000 SC(B)10 4240 16710 19150 6 50 7180 2380 1360 2430 2500 SC(B)10 4940 20030 22950 6 50 8790 2460 1360 2500 All given sound levels are max. values. P o: No-Load Loss P k 75 C: Load Loss at 75 C P k 120 C: Load Loss at 120 C U k: Impedance L PA: A-weight Sound Pressure Level in db NOTE: Technical data subject to change without prior notice. Rated Power of 3000kVA, 3500kVA & 4000kVA are available upon request. SC(B) 10 Low Loss 10

Green Asia Alliance Sdn. Bhd. (869408-H) 42, Jalan PJS 7/19, Bandar Sunway, 46150 Petaling Jaya, Selangor Darul Ehsan, Malaysia. Tel: +603-56312451/56310864 Fax: +603-56314639 Website: greenasia.com.my Email: enquiry@greenasia.com.my