S T T U S I N S T R U M E N T S

Similar documents
SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

Digital flow transmitter for continuous flow measurement

SEM210 SEM210X UNIVERSAL TEMPERATURE TRANSMITTER

Resistance thermometer Model TR30, compact design

CombiTemp TCR6 Standard RTD temperature sensor

SITRANS T measuring instruments for temperature

Digital conductivity transmitter

Infocal 9 Energy calculator

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

SonoMeter 31 Energy Meters

HART field temperature transmitter Models TIF50, TIF52, TIF62

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS

Resistance thermometer Model TR30, compact design

Digital flow ELEMENT transmitter for continuous flow measurement

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Isolators A3/1.

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

CONTA-ELECTRONICS. Converter Units

Resistance thermometer Model TR31, miniature design

Coriolis Massflowmeter

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

TMU. Coriolis Mass Flow Meter. for liquids and gas

Coriolis Massflowmeter

Miniature resistance thermometer Model TR33, thread-mounted

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement

UTM10 Series Ultrasonic Transit-time Flowmeters

Field indicator for current loops with HART communication Models DIH50, DIH52

PAD - Heavy Duty Differential Pressure Trasmitter

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Flow Measurement SITRANS F M

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

Resistance Thermometers Model Series TR7X0, Sheathed Design

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Level Measurement Continuous level measurement Radar transmitters

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Temperature Measurement

4-20mA, 0-10V and general process measuring bargraph displays

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

PR product range - links to order details and block diagrams

Valve Island with Electronic I/O

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Measurement and Instrumentation

Ultrasonic level meters ULM 70

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Digital inductive conductivity transmitter

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Level Measurement Continuous level measurement Radar transmitters

Temperature Transmitters - Head Mounted

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital flow ELEMENT transmitter for continuous flow measurement

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

INSERTION paddle wheel flowmeter for continuous flow measurement

Temperature transmitter itemp PCP DIN rail TMT 121

DIGITAL PANEL METERS. Overview of product range. Product selection guide. Info & advice. µdigi1 and µdigi2 ranges

mass flowmeter for compressed air

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

Coriolis Mass Flow Meter Model TM

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

The Rosemount 848T Wireless Temperature Transmitter

FAHM Co. Temperature Transmitter

Rosemount 148 Temperature Transmitter

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF UNDERGROUND SENSOR MANAGEMENT & DATA COMMUNICATIONS

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

In-Line Resistance Thermometers Model TR25

Temperature Transmitters - DIN Rail Mounted

Resistance thermometers for process technology

ph or ORP Transmitter

Electromagnetic Flow Transmitter

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

Temperature Sensor with Thread G1/4" FLEXadapt

Rosemount 3101, 3102, and 3105

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

ISOLATED 4-20 ma TRANSMITTERS

OPTIWAVE 1010 Technical Datasheet

TRONIC Digest. TRONIC Digest Pressure and Temperature Transmitters

Target disk flowmeter for liquids and gases

The transducer component converts the measured signal and displays the actual value.

Industrial Interface The Signal Conditioning People

Transcription:

S T T U S I N S T R U M E N T S

Welcome to the latest Status Instruments Product Guide Here at Status Instruments, we re very proud to say that we ve been making top-quality instrumentation for 30 years. We ve had some remarkable successes in that time, and we ve acquired a following of loyal customers who return to us year after year. They have come to appreciate our ongoing promise - that what goes into our products is inspiration, dedication and application - and what comes out is performance, reliability and value. Quality counts Quality has always been a priority for us at every level, and we currently operate a quality system approved to BS EN ISO9001:2008. Our products also comply with current EC directives and other national standards and regulations. How to use this Guide This latest edition of our Product Guide has a bold new look, with some design and layout revisions which make it easier to use - plus some important revisions to the product groupings. As in the previous edition, each colour-coded section shows what the range has to offer, and the products are then listed individually with their relevant specification details beneath. Ordering Please place your order directly with the distributor or agent who sent you this Guide - their details should be on the back cover. If you acquired this Guide independently, please contact Status Instruments directly, and we will be able to help you. Sales team: 44 (0) 1684 296818 Website: www.status.co.uk E-mail: sales@status.co.uk Signal Conditioning Isolators, Converters and Splitters Panel Meters Humidity Transmitters Field Mounted Process Displays Wireless Temperature Transmitters Rail-mounted Transmitters Loop-powered In-head Transmitters Loop-powered Temperature Sensors, Thermowells, Heads, Accessories, etc Pressure Transmitters 4 10 12 16 18 22 24 28 34 42 S T T U S I N S T R U M E N T S S T T U S I N S T R U M E N T S 2 3

Signal Conditioning RTD options Resistance Potentiometer Thermocouple oltage Frequency Pulse Counter Load Cell See Datasheet for specific output combinations Isolation Output zero/span alignment to input User offset User linearisation Remote reset Loop power supply Sensor power supply Max/min display Communications Totalise Maths functions Width 1600T RTD, Thermocouple and Potentiometer Input. Active or Passive or voltage output. m (10 to 10,500) Ω (1 to 100) kω auto sense K, J, N, E, T, R, S, L, U, B, C(W5), D(W3), G(W) (-100 to 200) m outputs: (Active or Passive) or oltage or Bi-Polar oltage - Resistance / Potentiometer / m (-20 to 70) C Universal, (10 to 48) DC and (10 to 32) AC - Output - direct USB 17.5 mm ± 1600I Process Signal Conditioner with Active or Passive or voltage input and output. (-50 to 50) DC (-50 to 50) outputs: (Active or Passive) or oltage or Bi-Polar oltage User linearisation (-20 to 70) C Universal, (10 to 48) DC and (10 to 32) AC - Input and Output - direct USB Flow Formulae 17.5 mm ± 1600B Load Cell Input Signal Conditioner with Active or Passive or voltage output. - 4-wire outputs: (Active or Passive) or oltage or Bi-Polar oltage - Tare (-20 to 70) C Universal, (10 to 48) DC and (10 to 32) AC - Output - direct USB 17.5 mm 1600F Dual input, single output, Frequency Conditioner and Pulse Counter, with Active or Passive or voltage output, plus relay. 0.02 Hz to 50 khz outputs: (Active or Passive) or oltage or Bi-Polar oltage plus relay (-20 to 70) C Universal, (10 to 48) DC and (10 to 32) AC - Output - direct USB 17.5 mm 1620 RTD, Thermocouple, Passive input, 3-wire voltage output. K, J, N, E, T, R, S (-40 to 75) m (-10 to 25) Passive Fixed-range programmable outputs: oltage, 3-wire (-20 to 70) C (15 to 28) DC - direct USB 17.5 mm Signal Conditioning 4 5 Tare ± Frequency / Pulse Count Excitation ± m o

Signal Conditioning RTD options Resistance Potentiometer Thermocouple oltage Frequency Pulse Counter Load Cell See Datasheet for specific output combinations Isolation Output zero/span alignment to input User offset User linearisation Remote reset Loop power supply Sensor power supply Max/min display Communications Totalise Maths functions Width 1630 RTD, Thermocouple, Passive input, with 2 change-over relay outputs. m K, J, N, E, T, R, S (-20 to 70) C 24 DC - direct USB 17.5 mm (-40 to 75) m (-10 to 25) Passive Fixed outputs: 2 x (250 AC @ 1 A) change-over relay 1633 RTD, Potentiometer input, with 2 change-over relay outputs. (10 to 10,500) Ω (1 to 100) kω auto sense - relays Fixed outputs: 2 x (250 AC @ 1 A) change-over relay - Resistance / Potentiometer (-20 to 70) C Universal, (10 to 48) DC and (10 to 32) AC - direct USB 17.5 mm 1636 Loop-powered Alarm Unit, with 2 change-over relay outputs. (4 to 20) Passive Fixed outputs: 2 x (250 AC @ 1 A) change-over relay - relays (-20 to 70) C (4 to 20) Loop - direct USB 17.5 mm 1700 Universal Signal Conditioner with current or voltage, and 2 change-over relay outputs. (20 to 400) Ω > 1 kω K, J, N, E, T, R, S, L, U, B, C(W5), D(W3), G(W) ±200 m, ±1, ±10 ±25 (Active or Passive) outputs: (Active or Passive) or oltage plus 2 x (250 AC @ 1 A) change-over relays - push-button (-20 to 70) C Universal, (20 to 250) DC and (22 to 240) AC Input and output - direct USB 22 mm 1720 Dual channel Signal Conditioner/ Splitter with temperature inputs and Active or Passive or voltage outputs. K, J, N, E, T, R, S, L, U, B, C(W5), D(W3), G(W) outputs: (Active or Passive) oltage (-20 to 70) C Universal, (20 to 250) DC and (22 to 240) AC Output, both channels - direct USB 22 mm Signal Conditioning 6 7 m 1 2

Signal Conditioning RTD options Resistance Potentiometer Thermocouple oltage Frequency Pulse Counter Load Cell See Datasheet for specific output combinations Isolation Output zero/span alignment to input User offset User linearisation Remote reset Loop power supply Sensor power supply Max/min display Communications Totalise Maths functions Width 1750 DUAL CHANNEL Signal Conditioner/ Splitter with Active or Passive or voltage inputs and outputs. (-50 to 50) DC (-50 to 50) (Active or Passive) outputs: (Active or Passive) oltage (-20 to 70) C Universal, (20 to 250) DC and (22 to 240) AC Input & output, both channels - direct USB 22 mm 1 2 MED 2100 series SINGLE CHANNEL Universal Input Intelligent Signal Conditioner 50 Ω to 10 kω K, J, T, R, S, E, L, N, B ±100 m, ±1, ±10 (Active or Passive) Output options: (Active or Passive) plus: 2 x (48 AC @ 1 A) N/C relays or 2 x (48 AC @ 1 A) C/O relays or 4 x (48 AC @ 1 A) N/C relays or 2 Channel - Passive (-30 to 60) C 24 DC or or or (See output options, above) / push-button RS485 Modbus - optional custom download 35 mm MED 2200 series DUAL CHANNEL Universal Input Intelligent Signal Conditioner 50 Ω to 10 kω K, J, T, R, S, E, L, N, B ±100 m, ±1, ±10 (Active or Passive) Output options: (Active or Passive) plus: 2 x (48 AC @ 1 A) N/C relays or 2 x (48 AC @ 1 A) C/O relays or 4 x (48 AC @ 1 A) N/C relays or 2 Channel - Passive (-30 to 60) C 24 DC (See output options, above) RS485 Modbus - optional custom download 35 mm MED 2300 series SINGLE CHANNEL Frequency Input Intelligent Signal Conditioner 0.1 Hz to 20 khz Output options: (Active or Passive) plus: 2 x (48 AC @ 1 A) N/C relays or 2 x (48 AC @ 1 A) C/O relays or 4 x (48 AC @ 1 A) N/C relays or 2 Channel - Passive (-30 to 60) C 24 DC (See output options, above) / push-button RS485 Modbus - optional custom download 35 mm MED 2400 series DUAL CHANNEL Frequency Input Intelligent Signal Conditioner 0.1 Hz to 20 khz Output options: (Active or Passive) plus: 2 x (48 AC @ 1 A) N/C relays or 2 x (48 AC @ 1 A) C/O relays or 4 x (48 AC @ 1 A) N/C relays or 2 Channel - Passive (-30 to 60) C 24 DC (See output options, above) RS485 Modbus - optional custom download 35 mm Signal Conditioning 8 9 1 2 or or or m NAMUR TTL NPN PNP or or or m NAMUR TTL NPN PNP 1 2 or or or

Isolators, Converters & Splitters Type Range olt drop Maximum loop supply Isolation Maximum load Loop power supply temperature Width 1000 (4 to 20) Loop Isolator Input 5.0 DC typical load Input 35 DC (4 to 20) Passive (4 to 20) Output 500 Ω Input loop - passive (0 to 70) C 12.5 mm 1010 Provides isolated power for a transmitter, derived from a powered loop 2-wire (4 to 20) transmitter (4 to 20) Output 5.0 DC plus load Output 35 DC Output loop - passive (0 to 70) C 21 mm 1015 Converts DC voltage to an isolated (4 to 20) signal DC voltage Any between (-10 to 100) DC Output 30 DC Output loop - passive (0 to 70) C 12.5 mm Isolating current loop booster (4 to 20) Passive (4 to 20) Input and output 2.7 DC Input and output 35 DC Output 1200 Ω Both loops - passive (0 to 70) C 12.5 mm Isolating current loop splitter (4 to 20) Passive (4 to 20) (4 to 20) Active (4 to 20) Passive (4 to 20) Passive (4 to 20) Passive 2 x 2-wire (4 to 20) Passive 1020 1200 Input and outputs 5.0 DC Input and output 32 DC Outputs 1200 Ω All loops - passive (0 to 70) C 12.5 mm 1300 Cool operating 24 DC power supply AC (90 to 253) AC 24 DC @ 250 (0 to 50) C 21 mm 24DC Isolators, Converters & Splitters 10 11

Panel Meters S Thermocouple oltage Potentiometer Load Cell Frequency / Pulse Remote Digital Inputs See Datasheet for specific output combinations Isolation Display User Linearisation Loop Power Supply Sensor Excitation Max / Min Display Comms - RS485 Modbus Maths Functions 720 Loop-powered panel meter (48 x 24) mm panel mount (Passive) 4-digit LED process display 4-digit LED 10 mm (-10 to 60) C (4 to 20) loop 3410 / Thermocouple panel meter with output options (96 x 48) mm panel mount K, J, T, R, S, E, L, N. B 2 x relay (250 AC @ 5 A) POD (Active or Passive) POD RS485 Modbus option POD 4-digit LED 14.2 mm (-30 to 60) C (20 to 35) DC or (90 to 253) AC Output (option) Output (option) 3420 / voltage panel meter with output options (96 x 48) mm panel mount (Active or Passive) (0 to 1) (1 to 5) (0 to 10) DC 2 x relay (250 AC @ 5 A) POD (Active or Passive) POD RS485 Modbus option POD 4-digit LED 14.2 mm (-30 to 60) C (20 to 35) DC or (90 to 253) AC Input, output (option) Output (option) 3430 High-voltage / current true RMS panel meter with output options (96 x 48) mm panel mount or or or or or or or or or 550 6A ±6A AC / DC ±550 AC / DC 2 x relay (250 AC @ 5 A) POD (Active or Passive) POD RS485 Modbus option POD 4-digit LED 14.2 mm (-30 to 60) C (20 to 35) DC or (90 to 253) AC Output (option) Output (option) Panel Meters 12 13

Panel Meters S Thermocouple oltage Potentiometer Load Cell Frequency / Pulse Remote Digital Inputs See Datasheet for specific output combinations Isolation Display User Linearisation Loop Power Supply Sensor Excitation Max / Min Display Comms - RS485 Modbus Maths Functions 6-digit universal panel meter with output options (96 x 48) mm panel mount 3600U K, J, T, R, S, E, L, N. B (Active or Passive) ±100 m, ±1 DC, ±10 DC - with comms 2 x relay (250 AC @ 5 A) POD (Active or Passive) POD RS485 Modbus option (RJ45) 6-digit LED 14.2 mm (-30 to 60) C (20 to 35) DC or (90 to 253) AC Input, output (option) / Comms option Option - with comms 3600A 6-digit universal panel meter with rate / totaliser with output options (96 x 48) mm panel mount or or or or or or K, J, T, R, S, E, L, N. B (Active or Passive) ±100 m, ±1 DC, ±10 DC - with comms 2 x relay (250 AC @ 5 A) POD (Active or Passive) POD RS485 Modbus option (RJ45) 6-digit LED 14.2 mm (-30 to 60) C (20 to 35) DC or (90 to 253) AC Input, output (option) / Comms option Rate / Total Option - with comms 4500U Multi-colour 5-digit universal panel meter with load cell input with output options (96 x 48) mm panel mount K, J, T (Active or Passive) ±10 DC 2 x relay (250 AC @ 8 A) option 4 x relay (250 AC @ 5 A) option (Active) option RS485 Modbus option NPN / PNP logic option oltage option 5-digit LED. 14.2 mm multi-colour (-10 to 60) C (10.5 to 70) DC and (22 to 53) AC or (85 to 265) AC and (100 to 300) DC Input, output (option) - load cell / Comms option, and tare Option 4500F Multi-colour 5-digit panel meter with frequency / pulse counter input with output options (96 x 48) mm panel mount 2 x relay (250 AC @ 8 A) option 4 x relay (250 AC @ 5 A) option (Active) option RS485 Modbus option NPN / PNP logic option oltage option 5-digit LED 14.2 mm multi-colour (-10 to 60) C (10.5 to 70) DC and (22 to 53) AC or (85 to 265) AC and (100 to 300) DC Scaling Output (option) / Comms option Total / Counter Option Panel Meters 14 15 Tare or or and or or or Frequency / Pulse Count Excitation or or and or or or

Humidity transmitters BASE ACCURACY * Supply voltage (15 to 30) DC when display fitted. Please note: images are shown with optional display fitted. Temperature range Humidity (RH) Temperature Humidity (RH) Output channels Output choices: Temperature Plug-in sensor Cable length Display option Humidity Dewpoint ΔTd - difference between dewpoint temperature and temperature 161W/H SINGLE CHANNEL wall mount humidity transmitter (-30 to 100) C (10 to 90) % ±0.5 C ± 2% RH 1 x (4 to 20) Default (10 to 30) DC * (-30 to 85) C 161D/H SINGLE CHANNEL duct mount humidity transmitter % % % (-30 to 100) C (10 to 90) % ±0.5 C ± 2% RH 1 x (4 to 20) Default (10 to 30) DC * (-30 to 85) C 161R/H SINGLE CHANNEL remote mount humidity transmitter (-30 to 100) C (10 to 90) % ±0.5 C ± 2% RH 1 x (4 to 20) Default 2 m or 5 m (10 to 30) DC * (-30 to 85) C 162W/HP DUAL CHANNEL wall mount temperature / humidity transmitter (-30 to 100) C (10 to 90) % ±0.5 C ± 2% RH 2 x (4 to 20) Default Default (10 to 30) DC * (-30 to 85) C 162D/HP DUAL CHANNEL duct mount temperature / humidity transmitter % C % C % C (-30 to 100) C (10 to 90) % ±0.5 C ± 2% RH 2 x (4 to 20) Default Default (10 to 30) DC * (-30 to 85) C 162R/HP DUAL CHANNEL remote mount temperature / humidity transmitter (-30 to 100) C (10 to 90) % ±0.5 C ± 2% RH 2 x (4 to 20) Default Default 2 m or 5 m (10 to 30) DC * (-30 to 85) C Humidity transmitters 16 17

Field Mounted Process Displays APPROALS Thermocouple oltage Linearisation/offset Display Max / min Battery life Enclosure Environmental rating EX ia 640P LCD battery-powered thermometer Sensor / surface mount Offset 4-digit LCD 8.5 mm (-10 to 70) C Battery 3.6 lithium 2 years typical ABS or Stainless Steel IP67 640XP ATEX-approved LCD battery-powered thermometer Sensor / surface mount Offset 4-digit LCD 8.5 mm (-10 to 50) C Battery 3.6 lithium 2 years typical ABS only IP67 LCD battery-powered thermocouple thermometer Sensor / surface mount K, J, T, R, S, E, L, N Offset 4-digit LCD 8.5 mm (-10 to 70) C Battery 3.6 lithium 2 years typical ABS or Stainless Steel 640XTC ATEX-approved LCD battery-powered thermocouple thermometer Sensor / surface mount K, J, T, R, S, E, L, N Offset 4-digit LCD 8.5 mm (-10 to 50) C Battery 3.6 lithium 18 19 640TC IP67 2 years typical ABS only IP67 Field Mounted Process Displays

Field Mounted Process Displays APPROALS Thermocouple oltage Linearisation/offset Display Max / min Battery life Enclosure Environmental rating EX ia 660 Large-digit LCD battery-powered thermometer Sensor / surface mount 4-digit LCD 20 mm (-10 to 50) C Battery 3.6 lithium 2 years typical Stainless steel 100 mm dia. IP65 Switch / links 700 (4 to 20) loop-powered LED process indicator Sensor / surface mount (4 to 20) loop (Passive) Both 4-digit LED 7 mm (-20 to 75) C (4 to 20) loop ABS or Stainless Steel IP67 ATEX-approved (4 to 20) looppowered LED process indicator Sensor / surface mount (4 to 20) loop (Passive) Both 4-digit LED 7 mm (-20 to 75) C (4 to 20) loop ABS only IP67 Head-mounted RTD, Thermocouple Transmitter with integrated display, configuration. Sensor / surface mount K, J, N, E, T, R, S 4-digit LED 7 mm (-40 to 85) C (15 to 30) DC ABS or Stainless Steel 20 21 700X 710 IP67 direct USB Field Mounted Process Displays

Wireless Temperature Transmitters RTD options Potentiometer Thermocouple oltage Custom linearisation User offset Communication Transmit / receive range Transmitter / receiver links Width WTX 700 Universal head-mounted wireless transmitter Sensor or surface-mount in SCH4, or sensor mount in SCH11 (shown). Up to 10 kω autosense J, K, T, L, U, E, N, S, R, B, C, D (0 to 50) m - set on receiver - set on receiver Measurement data on ISM band 868.4 MHz m 300 m line of sight Links to any number of receivers (-30 to 70) C Battery 3.6 lithium kit (see data sheet) WTR 900 / 04 Wireless receiver for up to 16 x WTX700 DIN rail mount From radio signal From radio signal From radio signal From radio signal From radio signal - potentiometer / m range 4 x current - Active / Passive or 4 voltage RS485 Modbus for up to 16 x WTX700 plus display 300 m line of sight Links up to 16 x WTX700 (-20 to 50) C (110 to 240) AC or (20 to 30) DC kit / push-button 22.5 mm WTR 900 / 22 Wireless receiver for up to 16 x WTX700 DIN rail mount From radio signal From radio signal From radio signal From radio signal From radio signal - potentiometer / m range 2 x current - Active / Passive or 2 voltage 2 off (250 AC @ 3A) C/O relay RS485 Modbus for up to 16 x WTX700 plus display 300 m line of sight Links up to 16 x WTX700 (-20 to 50) C (110 to 240) AC or (20 to 30) DC kit / push-button 22 23 or 22.5 mm or Wireless Temperature Transmitters

Rail-mounted, loop-powered APPROALS RTD options Potentiometer Thermocouple type oltage Isolation Custom linearisation Output zero / span alignment to input Width EX ia IEC Ex 213P SINGLE CHANNEL Transmitter - push-button configuration - 2, 3-wire - 2, 3-wire - to order - push-button (-40 to 85) C (10 to 30) DC 12.5 mm 213TC SINGLE CHANNEL Thermocouple Transmitter - push-button configuration K, J, N, E, T, R, S (-10 to 70) m - push-button (-40 to 85) C (10 to 30) DC 12.5 mm 1603P SINGLE CHANNEL Transmitter - configuration - 2, 3-wire (-20 to 70) C (11 to 30) DC 17.5 mm 1603TC SINGLE CHANNEL Thermocouple Transmitter - configuration K, J, N, E, T, R, S (-40 to 75) m (4 to 20) (4 to 20) (4 to 20) (4 to 20) 24 25 m m (-20 to 70) C (11 to 30) DC 17.5 mm Rail-mounted, loop-powered

Rail-mounted, loop-powered APPROALS RTD options Potentiometer Thermocouple type oltage Isolation Custom linearisation Output zero / span alignment to input Width EX ia IEC Ex 1610 SINGLE CHANNEL Universal Transmitter, USB direct configuration - 2, 3-wire - push-button (-20 to 70) C (11 to 30) DC / direct USB 17.5 mm m K, J, N, E, T, R, S (-40 to 75) m (0 to 20) or (4 to 20) Passive 1801/2XR SINGLE OR DUAL CHANNEL RTD, Potentiometer, Resistance Transmitter - configuration. IS-approved. - 2, 3-wire - 2, 3-wire (1 to 100) kω auto sense - Resistance / Potentiometer (-20 to 70) C (10 to 30) DC 22 mm 1801/2XTC 1 1 2 2 SINGLE OR DUAL CHANNEL Thermocouple, Transmitter - configuration. IS-approved. K, J, N, E, T, R, S, L, U, B, C(W5), D(W3) G(W) - m (-20 to 70) C (10 to 30) DC 22 mm 315 SINGLE CHANNEL Universal Transmitter with HART Protocol - 2, 3, 4-wire Up to 100 kω with external resistor K, J, T, R, S, L, E, N, Custom (-10 to 85) m (4 to 20) (4 to 20) (4 to 20) (4 to 20) HART m (-20 to 70) C (10 to 40) DC / HART configurator 26 27 18.25 mm Rail-mounted, loop-powered

In-head, loop-powered APPROALS RTD options Resistance Potentiometer input Thermocouple type oltage Isolation Custom linearisation Output zero / span alignment to input User offset EX ia IEC Ex FM Sine ibration DN Standard Gost R 203P Transmitter - push-button configuration - 2, 3-wire, to order - to order - push-button (-40 to 85) C (10 to 30) DC 43 mm 203TC Thermocouple Transmitter, - push-button configuration m K, J, N, E, T, R, S (-10 to 70) mdc - push-button (-40 to 85) C (10 to 30) DC 43 mm 206P Transmitter - configuration - 2, 3-wire (-40 to 85) C (10 to 30) DC 43 mm 206TC Thermocouple Transmitter - configuration K, J, N, E, T, R, S (-10 to 70) mdc (-40 to 85) C (10 to 30) DC 43 mm HTR 200/1 Miniature head-mounted RTD, Potentiometer, Resistance Transmitter - configuration - 2, 3-wire - 2, 3-wire (10 to 10,500) Ω (1 to 100) kω auto sense (4 to 20) (4 to 20) (4 to 20) (4 to 20) (4 to 20) m - Resistance/Potentiometer (-40 to 85) C (10 to 30) DC 50 mm (excluding cable entry) In-head, loop-powered 28 29

In-head, loop-powered APPROALS RTD options Resistance Potentiometer input Thermocouple type oltage Isolation Custom linearisation Output zero / span alignment to input User offset EX ia IEC Ex FM Sine ibration DN Standard Gost R HTR 200/1 Miniature head-mounted RTD, Potentiometer, Resistance Transmitter - configuration with voltage output - 2, 3-wire - 2, 3-wire (10 to 10,500) Ω (1 to 100) kω auto sense 3-wire programmable voltage output - Resistance/Potentiometer (-40 to 85) C (10 to 30) DC 50 mm (excluding cable entry) o TTR 200 RTD, Potentiometer, Resistance Transmitter - configuration. - 2, 3-wire - 2, 3-wire (10 to 10,500) Ω (1 to 100) kω auto sense (4 to 20) - Resistance/Potentiometer (-40 to 85) C (10 to 30) DC 43 mm RTD, Potentiometer, Resistance Transmitter - configuration. IS-approved. - Resistance/Potentiometer See user manual (10 to 30) DC 43 mm TTC 200 Thermocouple, m Transmitter, configuration. TTC 200X Thermocouple, m Transmitter, configuration. IS-approved. In-head, loop-powered 30 31 TTR 200X - 2, 3-wire - 2, 3-wire (10 to 10,500) Ω (1 to 100) kω auto sense K, J, N, E, T, R, S, L, U, B, C(W5), D(W3), G(W) (-100 to 200) m - m (-40 to 85) C (10 to 30) DC 43 mm m K, J, N, E, T, R, S, L, U, B, C(W5), D(W3), G(W) (-100 to 200) m (4 to 20) (4 to 20) (4 to 20) - m See user manual (10 to 30) DC 43 mm m

In-head, loop-powered APPROALS RTD options Resistance Potentiometer input Thermocouple type oltage Isolation Custom linearisation Output zero / span alignment to input User offset Width / diameter EX ia IEC Ex FM Sine ibration DN Standard Gost R 210 RTD, Thermocouple, Potentiometer, m Transmitter, configuration. m - 2, 3-wire (1 to 100) kω auto sense K, J, N, E, T, R, S (-10 to 75) m (-40 to 85) C (10 to 30) DC 43 mm dia. 210X RTD, Thermocouple, Potentiometer, m Transmitter, configuration. IS-approved. m - 2, 3-wire (1 to 100) kω auto sense K, J, N, E, T, R, S (-10 to 75) m (-40 to 85) C (10 to 30) DC 43 mm dia. HART Protocol RTD, Thermocouple, Slidewire, m Transmitter, configuration. HART Protocol RTD, Thermocouple, Slidewire, m Transmitter, configuration. IS-approved. In-head, loop-powered 32 33 310 m (-40 to 85) C (10 to 40) DC / HART configurator 44 mm dia. - 2, 3 and 4-wire Up to 100 kω with external resistor K, J, T, R, S, E, L, N, Custom (-10 to 75) m 310X m (-40 to 85) C (10 to 40) DC / HART configurator 44 mm dia. - 2, 3 and 4-wire Up to 100 kω with external resistor K, J, T, R, S, E, L, N, Custom (-10 to 75) m (4 to 20) (4 to 20) (4 to 20) HART (4 to 20) HART

Temperature sensors (images not necessarily to scale) You tell us. An extensive range is shown here, but we can supply probes and sensors to almost any specification. Please contact our Sales Team for more details. The specification details opposite reflect popular choices, but we can supply products to suit almost any need. Please call to discuss your requirements. Sensing Process Extension Head Wire leads Temperature range Immersion lengths Style 1 Temperature sensor with fixed process connection. Immersion length (parallel ) Immersion length (tapered ) Extension length 6 mm dia. typical 1/2 BSP typical Typically 75 mm long x 12.7 mm dia. M24, 1/2 BSP or your choice PTFE 150 mm typical Head Extension Process Style 2 Temperature sensor for use with a compression gland. 6 mm dia. typical Immersion length M24, 1/2 BSP or your choice PTFE 150 mm typical Head Style 3 Temperature sensor with removable inset sensor. Immersion length (parallel ) Immersion length (tapered ) Extension length 7.9 mm dia. typical 1/2 BSP typical Typically 75 mm long x 12.7 mm dia. M24, 1/2 BSP or your choice PTFE 150 mm typical Inset Head Extension Process Style 4 Flying lead temperature sensor for use with a compression gland. 6 mm dia. typical Immersion length Cable length PTFE 1 m long typical Cable Style 5 Flying lead strap-on temperature probe for surface temperature measurement. 1/4 square typical Typically 19 mm long x 4 mm dia. length Extension Cable length length PTFE 1 m long typical Cable Extension Style 6 Temperature probe for energy management applications. Can only be used with SCH4 head. 6 mm dia. typical Immersion length PTFE 75 mm typical Temperature sensors Material Usually 316 stainless steel Usually 316 stainless steel Usually 316 stainless steel Usually 316 stainless steel Usually aluminium Usually 316 stainless steel 34 35

Temperature sensors (images not necessarily to scale) You tell us. An extensive range is shown here, but we can supply probes and sensors to almost any specification. Please contact our Sales Team for more details. The specification details opposite reflect popular choices, but we can supply products to suit almost any need. Please call to discuss your requirements. Sensing Process Extension Head Wire leads Temperature range Immersion lengths Style 7 Outdoor air temperature probe. Can only be used with SCH4 or SCH15 heads. length 12.7 mm dia. typical M16 only PTFE 75 mm typical Head Style 8 Flying lead temperature probe for use with Field Mounted Displays. 6 mm dia. typical length Cable length Usually M16 PTFE 1 m long typical Head Cable Style 9 Temperature probe for use with Field Mounted Displays. Allows the head display to be orientated. Extension length Immersion length (parallel ) Immersion length (tapered ) 6 mm dia. typical 1/2 BSP typical Typically 75 mm long x 12.7 mm dia. Usually M16 PTFE 150 mm typical Male running nut Extension Process Style 10 Temperature probe for screw fitting into an internal hygienic type process connection. Immersion length (parallel ) Extension length 6 mm dia. typical 3/4 BSP male, typical Typically 75 mm long x 12.7 mm dia. M24, 1/2 BSP or your choice PTFE 150 mm typical Extension Process / male running nut Style 11 Temperature probe for screw fitting into an external hygienic type process connection. Immersion length (parallel ) Extension length 6 mm dia. typical 3/4 BSP female, typical Typically 75 mm long x 12.7 mm dia. M24, 1/2 BSP or your choice PTFE 150 mm typical Head Extension Process / female running nut Style 12 Temperature probe for fitting to hygienic process connections such as IDF, RJT, or SMS. Immersion length (parallel ) Extension length 6 mm dia. typical To special order Typically 75 mm long x 12.7 mm dia. M24, 1/2 BSP or your choice PTFE 150 mm typical Head Extension Hygienic fitting Female running nut Temperature sensors Material Usually 316 stainless steel Usually 316 stainless steel Usually 316 stainless steel Usually 316 stainless steel Usually 316 stainless steel Usually 316 stainless steel 36 37

Thermowells & Pockets (images not necessarily to scale) You tell us. An extensive range is shown here, but we can supply thermowells and pockets to almost any specification. Please contact our Sales Team for more details. The specification details opposite reflect popular choices, but we can supply products to suit almost any need. Please call to discuss your requirements. Parallel sheath Tapered sheath Process Internal Compression fitting Immersion length Material Flange STW Style 1 Thermowell for use with temperature sensors styles 1 and 9. 7.9 mm dia. typical 3/4 BSP typical 1/2 BSP typical Usually 316 stainless steel Immersion length (parallel ) Immersion length (tapered ) Internal Process Bore diameter STW Style 2 Thermowell for use with temperature sensors styles 2, 4 and 6. Immersion length (parallel ) 7.9 mm dia. typical 1/2 BSPT typical 1/4 BSPT x 6 mm typical Usually 316 stainless steel / compression gland brass Immersion length (tapered ) Compression gland Process Bore diameter STW Style 3 Weld-in thermowell for styles 1 and 9 temperature probes, and styles 2, 4 and 6 with compression gland. 7.9 mm dia. typical 1/2 BSP typical Usually 316 stainless steel STW Style 4 Solid turned thermowell for use where higher mechanical strength is required. For use with styles 1 and 9. Head height 3/4 BSP typical 1/2 BSP typical Usually 316 stainless steel Immersion length (parallel ) Immersion length (tapered ) Internal Head Process Major dia. Minor dia. Bore diameter STW Style 5 Fabricated flanged thermowell, usually with adjustable extension and spring-loaded inset sensor. Immersion length Spigot length 7.9 mm dia. typical 1/2 BSP typical Usually 316 stainless steel Internal Flange Bore diameter STW Style 6 Solid turned (for high strength) flanged thermowell, usually with adjustable extension and spring-loaded inset sensor. Immersion length Spigot length 1/2 BSP typical Usually 316 stainless steel Internal Flange Major dia. Minor dia. Bore diameter Thermowells & Pockets 38 39 Immersion length Head height Internal Bore diameter

Heads, Accessories, etc Heads Display window when used with - Cable entry Sensor entry Protection Mounting Body entry styles Approvals Accessories Stocked versions Your spec Material Terminals SCH4 ABS plastic connection head / terminal box. 600 / 700 / 710 and 160 M16, M20, M24, 1/2 M16, M20, M24, 1/2 IP67 Head, wall, duct, pipe Base / side Side / side Side only Compression glands For use with 2 / 4 temperature sensors. 1/4 BSP or 1/2 BSP x 6 mm To order 316 stainless steel SCH11 Aluminium alloy connection head. M20 M24 IP67 Head Base / side - - CB4 / CB6 Connection blocks, for use where high temperatures are to be measured. In stock Ceramic 4 or 6 way SCH15 Stainless steel connection head for use with 600 / 710 600 / 700 / 710 M20 M16 IP67 Head - Side / side Side only Mounting kit SMK For mounting transmitters or connection blocks to heads fitted with style 3 sensors In stock SCH50 Exd ATEX explosion-proof aluminium alloy / stainless steel connection head. Loop indicator based on 700 M16, M20, M24, 1/2 M16, M20, M24, 1/2 IP67 Head, wall, duct, pipe Base / side Side / side Side only Exd flameproof head Mounting kit RMK /1G For mounting in head transmitters to DIN G rail In stock (images not necessarily to scale) Mounting kit RMK / 3T For mounting in head transmitters to DIN top hat rail In stock Sensor / transmitter Sensing element Measuring range typical Process Immersion lengths Material Accuracy Ouput STA 206 Cost-effective temperature sensor with built-in transmitter class A (-50 to 200) C 6 mm dia. 1/2 BSP to your spec 316 stainless steel 0.25% FRS (10 to 30) DC (4 to 20) Heads, Accessories, etc 40 41

Pressure transmitters PROCESS CONNECTION APPROALS Pressure Range 2-wire (4 to 20) loop-powered oltage output 1/4 BSP 1/4 NPT 1/2 BSP 1/2 BSP flush Other to order Open or closed ends Exia PTX 130/1/2 General purpose pressure transmitter General purpose pressure transmitter ATEX-approved general purpose pressure transmitter ATEX-approved general purpose submersible level transmitter Up to 700 Bar Below 1 Bar Up to 1000 Bar Up to 250m H 2 O (optional) PTX 130/3/4 (optional) PTX 19 PTX 20 Pressure transmitters 42 43

S T T U S I N S T R U M E N T S www.status.co.uk Every effort has been made to ensure the accuracy of the information contained in this Product Guide, but the company accepts no liability for any errors or omissions. Unless previously agreed in writing, all transactions are subject to our standard Terms and Conditions of sale, available on request or from our website, at www.status.co.uk 52-715-2170-05